DRINKING WATER SYSTEM COMPONENTS CERTIFIED FOR CANADA | UL Product iQ 15/01/20, 12(05 AM

FDNP7.MH26118 - DRINKING WATER SYSTEM


COMPONENTS CERTIFIED FOR CANADA
Drinking Water System Components Certified for Canada
See General Information for Drinking Water System Components Certified for Canada

CARBOLINE CO MH26118
350 HANLEY INDUSTRIAL CT
SAINT LOUIS, MO 63144-1510 USA

NSF/ANSI 61
Plant at: Green Bay, Wisconsin

Barrier Materials
Water Surface Area
Contact Water Contact to
Trade Dsg Temp (°C) Mtl Volume Ratio

Carboguard 61 (j) 23 Epoxy 29.0 sq cm/L

Carboguard 635 (i) 23 Epoxy 23.2 sq cm

Carboguard 635 (ii) 23 Epoxy 10.32 sq cm

Carboguard 635 VOC (ab) 23 - 23.2 sq.cm/L

Carboguard 692 (d) (e) 23 Epoxy 68 sq cm/L

Carboguard 891 (f) (g) 23 Epoxy 11.61 sq


cm/L

Carboguard 891 VOC (h) (y) 23 Epoxy 9.03 sq cm/L

Carboweld 17 FG (k) 23 Inorganic Zinc 48.39 sq


Primer cm/L

Carbozinc 621 PW (ac) 23 - 7.9 sq.cm/L

Carbozinc 8703 (v) 23 Inorganic Zinc 13.5 sq cm/L


Primer

Phenoline 341 (o) 23 Epoxy 98 sq cm/L

Phenoline Tank Shield (aa) 23 Epoxy 131.2


sq.cm/L

PLASITE 4500 (b) 23 Epoxy 393.7 sq


cm/L

https://iq.ulprospector.com/en/profile?e=33872 Page 1 of 5
DRINKING WATER SYSTEM COMPONENTS CERTIFIED FOR CANADA | UL Product iQ 15/01/20, 12(05 AM

Plasite 4500S - Light Blue, Red, White and Light 23 Epoxy 37 sq cm/L
Grey (a)

Plasite 4501 (o) 23 Epoxy 98 sq cm/L

Polyclad 767 (s) 23 Polyurethane 131.23 sq


cm/L

Polyclad 767 Fast-Set Plus (s) 23 Polyurethane 131.23 sq


cm/L

Polyclad 767 Slow-Set (s) 23 Polyurethane 131.23 sq


cm/L

Reactamine 760 (w) 23 Polyurethane 85.81 sq


cm/L

Reactamine 760 HB (x) 23 Polyurethane 112.5 sq


cm/L

Plant at: Lake Charles, Louisiana

Barrier Materials
Water Surface Area
Contact Water Contact to
Trade Dsg Temp (°C) Mtl Volume Ratio

Carboguard 61 (j) 23 Epoxy 29.0 sq cm/L

Carboguard 635 (i) 23 Epoxy 23.2 sq cm

Carboguard 635 (ii) 23 Epoxy 10.32 sq cm

Carboguard 691 (m) (n) 23 Epoxy 12 sq cm/L

Carboguard 692 (d) (e) 23 Epoxy 68 sq cm/L

Carboguard 891 (f) (g) 23 Epoxy 11.61 sq


cm/L

Carboguard 891 VOC (h) (y) 23 Epoxy 9.03 sq cm/L

Carboweld 9 WB (z) 23 Zinc Primer 48.4 sq cm

Carbozinc 621 PW (ac) 23 - 7.9 sq.cm/L

Carbozinc 8703 (v) 23 Inorganic Zinc 13.5 sq cm/L


Primer

Phenoline 341 (o) 23 Epoxy 98 sq cm/L

Phenoline Tank Shield (aa) 23 Epoxy 131.2


sq.cm/L

PLASITE 4500 (b) 23 Epoxy 393.7 sq


cm/L

https://iq.ulprospector.com/en/profile?e=33872 Page 2 of 5
DRINKING WATER SYSTEM COMPONENTS CERTIFIED FOR CANADA | UL Product iQ 15/01/20, 12(05 AM

Plasite 4500S - Light Blue, Red, White and Light 23 Epoxy 37 sq cm/L
Grey (a)

Plasite 4501 (o) 23 Epoxy 98 sq cm/L

Reactamine 760 (w) 23 Polyurethane 85.81 sq


cm/L

Reactamine 760 HB (x) 23 Polyurethane 112.5 sq


cm/L

(a) - For use with tanks greater than or equal to 1,000 gallons, pipes where the diameter is greater than or equal to 42 inches,
and valves, not exceeding a surface area to volume ratio of 37 cm2/L, only when Part A is mixed with Part B in a 4.0:1.0 parts by
volume ratio. Maximum Field Use Dry Film Thickness (mils) = 60; Thinner = None; Cure Time = 7 days at 75 deg F; Number of
Coats = 1; Application Method = Spray with brush or roll for touch-ups; Colors =Light Blue, Red, White and Light Gray. Certified
for use on new pipe. Note - see manufacturers instructions for additional product use information. This product was tested
without a primer or an additional topcoat. It is recommended that any primer or topcoat used should be certified to NSF/ANSI 61
by an ANSI accredited certifier.

(aa) - For use with tanks greater than or equal to 500 gallons, pipes where the diameter is greater than or equal to 12 inches,
valves and fittings of 4 inches and greater not exceeding a surface area to volume ratio of 131.2 sq. cm./L, only when Part A is
mixed with Part B in a 1.0:1.0 parts by volume ratio. Maximum Field Use Dry Film Thickness (mils) = 50; Thinner = None; Cure
Time = 4 days at 75 deg F; Number of Coats = 1-2; Application Method = Spray, brush or roll for touch-ups; Colors = White
(N800), Grey (N700) and Blue (N100). Note - see manufacturers instructions for additional product use information. This product
was tested without a primer or an additional topcoat. It is recommended that any primer or topcoat used should be certified to
NSF/ANSI 61 by an ANSI accredited certifier.

(ab) - For use with tanks greater than or equal to 4,000 gallons and valves in diameter 4" and greater not exceeding a surface
area to volume ratio of 23.2 cm2/L. Mix Ratio: For use only when Part A is mixed with Part B in a 4:1 parts by weight ratio;
Number of Coats: 1-2; Maximum Dry Film Thickness: 16 mils; Colors: 0200 Tan, 0700 Gray, 0800 White and 0100 Blue;
Application Method = Spray with brush or roll for touch-ups; Maximum Thinner: Thinner 76 at 10% by volume; Final Cure prior to
water immersion: 7 days @ 75F

(ac) - For use with tanks greater than or equal to 100,000 Gallons not exceeding a surface area to volume ratio of 7.9 cm2/L.
Number of coats = 1-2; Maximum dry film thickness= 8 mils; Minimum Cure Time= 24 hours (70-75 degF); Application Method =
Spray with brush or roll for touch-ups; Maximum Thinner: 10% Thinner #10. This product was tested without an additional
primer or topcoat. It is recommended that any primer or topcoat used should be certified to NSF/ANSI Standard 61 by an ANSI
accredited certifier.

(b) - For use with tanks greater than or equal to 5 gallons and pipes where the diameter is greater than or equal to 4 inch, not
exceeding a surface area to volume ratio of 393.7 cm2/L, only when Part A is mixed with Part B in a 4.0:1.0 parts by volume
ratio. Application Method: Plural Component Airless Spray; Number of coats=1; Maximum dry film thickness= 50 mils; Minimum
Cure Time=3 days; Application Temperature Part A = 110-140 deg F; Application Temperature Part B = 90-131 deg F; Certified
for use on new pipe; Note - see manufacturers instructions for additional product use information.This product was tested
without a primer or an additional topcoat. It is recommended that any primer or topcoat used should be certified to ANSI/NSF
Standard 61 by an ANSI accredited certifier. Product is Classified in the following colors: Light Grey, Tile Red, Blue, and White

(d) - Product is Classified in the following colors: Blue 0100, Off White 0800, Beige 0200, Red 0500, or Grey 0700

(e) - For use with tanks > or equal to 200 Gallons and pipes where the diameter is > or equal to 24 in, not exceeding a surface
area to volume ratio of 68 cm2/L, only when Part A is mixed with Part B in a 4.0:1.0 parts by volume ratio. Maximum
Thinner=10% Thinner #10 by Volume; Maximum Number of Coats=2; Maximum Dry Film Thickness=16 mils total and 8 mils per
coat; Minimum Recoat Time = 24 hrs at 75 deg F; Application Method = Spray with brush or roll for touch-ups; Minimum Cure
Time=7 days at 75 deg F. Applicationn Method = Spray (Touch-up and weld striping using a brush or roller is acceptable)
Certified for use on new pipe. Note - see manufacturers instructions for additional product use information. This product was
tested without a primer or an additional topcoat. It is recommended that any primer or topcoat used should be certified to
ANSI/NSF Standard 61 by an ANSI accredited certifier.

(f) - Product is Classified in the following colors: White 1898, Red 0500, Red B532, Gray 2713, Brown 3216, White S800, Gray
4753, Gray 0794, Black C900, Blue 4169, Blue 5141, Blue 1120, Blue 6115, White 8898, Lt. Tan 9668, Blue 6120.

https://iq.ulprospector.com/en/profile?e=33872 Page 3 of 5
DRINKING WATER SYSTEM COMPONENTS CERTIFIED FOR CANADA | UL Product iQ 15/01/20, 12(05 AM

(g) - For use with tanks greater than or equal to 30,000 gallons and valves greater than or equal to 4", not exceeding a surface
area to volume ratio of 11.61 cm2/L, only when Part A is mixed with Part B in a 1.0:1.0 parts by volume ratio. Application Method
= Spray with brush or roll for touch-ups. Maximum Thinner = 6% Thinner #2 by volume; Minimum cure time = 5 days after last
coat; Maximum Dry Film Thickness = 17 mils; Number of coats = 2-3; Note - See manufacturer`s use instructions for additional
product information. This product was tested without a primer or an additional topcoat. It is recommended that any primer or
topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.

(h) - For use with tanks greater than or equal to 50 gallons, valves, 1.5 in. diameter or greater and pipes where the diameter is
greater than or equal to 15", not exceeding a surface area to volume ratio of 108.4 cm2/L. Mix Ratio: For use only when Part A is
mixed with Part B in a 2:1 parts by volume ratio; Number of Coats: 2 - 3; Maximum Dry Film Thickness: 20 mils; Minimum Cure
Time = 14 days @75F; Colors: Light grey (0700), White (0800), Light blue (0100), Black (0900), Blue (6120), Gray (0794), and Tan
(0200); Application Method: Application Method = Spray with brush or roll for touch-ups; Maximum Thinner: Carboline Thinner
#2 or 225E, up to a maximum of 13 oz per gallon; Final Cure prior to water immersion: 14 days @ 75F. Note - see manufacturer's
instructions for additional product use information. This product was tested without an additional primer or topcoat. It is
recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.

(i) - For use with tanks greater than or equal to 4,000 gallons not exceeding a surface area to volume ratio of 23.2 cm2/L, only
when Part A is mixed with Part B in a 4.0:1.0 parts by volume ratio. Number of coats= 1 - 2 coats; Application Method = Spray
with brush or roll for touch-ups; Maximum dry film thickness= 12 mils; Thinner= Thinner 10 at 5% by volume. Cure Time=7 days.
Colors = Beige (0200), Gray (0700), White (0800), Blue (1120), Black (0900), and Red (B532). Note - see manufacturer's
instructions for additional product use information. This product was tested without an additional primer or topcoat. It is
recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.

(ii) - For use with tanks greater than or equal to 50,000 gallons not exceeding a surface area to volume ratio of 10.32 cm2/L, only
when Part A is mixed with Part B in a 4.0:1.0 parts by volume ratio. Number of coats= 3; Application Method = Spray with brush
or roll for touch-ups; Maximum dry film thickness= 18 mils; Thinner= Thinner 38 at 8% by volume. Cure Time between coats = 2
hours; Final Cure =7 days. Note - see manufacturer s instructions for additional product use information. This product was tested
without an additional primer or topcoat. It is recommended that any primer or topcoat used should be certified to NSF/ANSI
Standard 61 by an ANSI accredited certifier.

(j) - For use with tanks greater than or equal to 2,000 gallons, pipe diameter of 54" or greater and valves 4" or greater, not
exceeding a surface area to volume ratio of 29.0 cm2/L, only when Part A is mixed with Part B in a 1.0:1.0 parts by volume ratio.
Number of coats= 2 - 3 coats; Application Method = Spray with brush or roll for touch-ups Maximum dry film thickness= 20 mils;
Thinner= Thinner #2 at 13 oz/gal or 10%. Cure Time= 7 days. Colors: Beige (3216), White (S800), Blue (4169), or Gray (0794)
Note - see manufacturer's instructions for additional product use information. This product was tested without an additional
primer or topcoat. It is recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI
accredited certifier.

(k) - For use with tanks greater than or equal to 500 gallons, not exceeding a surface area to volume ratio of 48.39 sq cm/L.
Colors: Red and Grey; Mix Ratio: 1.65 Part A to 3.35 Part B by volume; Maximum Dry Film Thickness: 1 mil; Number of Coats: 1;
Minimum Cure Time: 8 days at 75 deg F; Application Method = Spray with brush or roll for touch-ups; Thinner: Thinner #21 up to
4.5% by volume; This product is certified for use on new pipe. Note - see manufacturers instructions for additional product use
information. This product was tested without an additional primer or topcoat. It is recommended that any primer or topcoat used
should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.

(m) - Product is Classified in the following colors:0700 Grey, 0200 Beige, 0500 Red, 0100 Blue, and Black

(n) - For use with tanks greater than or equal to 30,000 gallons and valves 4" or greater not exceeding a surface area to volume
ratio of 12 cm2/L, only when Part A is mixed with Part B in a 1.0:4.0 parts by volume ratio. Maximum Thinner=12.5% Thinner #2
by Volume; Application Method = Spray with brush or roll for touch-ups. Number of coats= 1-2; Maximum Dry Film Thickness =
20 mils (single coat), 30 mils (two coats); Minimum Cure Time = 7 days. Note - see manufacturers instructions for additional
product use information. This product was tested without a primer or an additional topcoat. It is recommended that any primer
or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.

(o) - May be one of the following colors: Blue 0100, Off White 0800, Grey 0700, or Dark Grey J700; For use with tanks greater
than or equal to 75 gallons, and pipes where the diameter is greater than or equal to 16 inches, and valves 1.75" or greater, not
exceeding a surface area to volume ratio of 98 cm2/L, only when Part A is mixed with Part B in a 4.0:1.0 parts by volume ratio.
Number of coats=1-2; Maximum dry film thickness= 30 mils (one coat) or 60 mils (two coats); Application Method = Spray with
brush or roll for touch-ups; Minimum Recoat Time = 24 hrs at 75 deg F; Minimum Cure Time=7 days at 75 deg F. Certified for
use on new pipe. Note - see manufacturers instructions for additional product use information. This product was tested without a
primer or an additional topcoat. It is recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61
by an ANSI accredited certifier.

https://iq.ulprospector.com/en/profile?e=33872 Page 4 of 5
DRINKING WATER SYSTEM COMPONENTS CERTIFIED FOR CANADA | UL Product iQ 15/01/20, 12(05 AM

(s) - Product is Classified in the following colors: Green 0300, Grey 0700, Blue 0100. For use with pipes where the diameter is
greater than or equal to 12 inch, with tanks greater than or equal to 1000 gallons, and valves 12 inches or larger and not
exceeding a surface area to volume ratio of 131.23 cm2/L. For use only when Part A is mixed with Part B in a 1.0:1.0 parts by
volume ratio; Number of coats=1; Maximum dry film thickness= 120 mils; Minimum Cure Time=48 hours (75 F). Application
Method = Spray with brush or roll for touch-ups. Thinner is not to be used with this coating. Note - see manufacturers
instructions for additional product use information. This product was tested without an additional primer or topcoat. It is
recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.
Certified for use on new pipe.

(v) - For use with tanks greater than or equal to 20,000 Gallons and pipes where the diameter is greater than or equal to 118
inches not exceeding a surface area to volume ratio of 13.5 cm2/L, only when Carbozinc 8703 Base is mixed with Zinc Filler
Type 3 as a complete kit. Number of coats = 1; Maximum dry film thickness= 2 mils; Minimum Cure Time= 2 weeks (70-75 F);
Application Method = Spray with brush or roll for touch-ups; Maximum Thinner: 20% Thinner #33 or Thinner #21. This product
was tested without an additional primer or topcoat. It is recommended that any primer or topcoat used should be certified to
ANSI/NSF Standard 61 by an ANSI accredited certifier.

(w) - Product is Classified in the following colors: Light Tan (0200 Brown), Blue (P100 Blue), Grey (0700 Grey) and Beige (S200).
For use with tanks greater than or equal to 100 gallons, and for use with pipes where the diameter is greater than or equal to 20",
not exceeding a surface area to volume ratio of 85.81 cm2/L. For use only when Part A is mixed with Part B in a 2:1 parts by
volume ratio; Number of Coats = 1-2; Maximum Dry Film Thickness = 125 mils; Minimum Cure Time = 4 hours (61°F). Application
Method = Spray with brush or roll for touch-ups. Thinner is not to be used with this coating. Note - see manufacturer's
instructions for additional product use information. This product was tested without an additional primer or topcoat. It is
recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited certifier.
Certified to be returned to service after the 4 hour cure time. Certified to rehabilitate existing pipe. Certified for use on pipe
intended for immediate return to service.

(x) - Product is Classified in the following color: Light Tan (0200). For use with tanks greater than or equal to 50 gallons, and for
use with pipes where the diameter is greater than or equal to 14", not exceeding a surface area to volume ratio of 112.5 cm2/L.
For use only when Part A is mixed with Part B in a 2:1 parts by volume ratio; Number of Coats = 1 - 2; Maximum Dry Film
Thickness = 300 mils; Minimum Cure Time = 4 hours (59°F) . Application Method = Spray with brush or roll for touch-ups.
Thinner is not to be used with this coating. Note - see manufacturer's instructions for additional product use information. This
product was tested without an additional primer or topcoat. It is recommended that any primer or topcoat used should be
certified to ANSI/NSF Standard 61 by an ANSI accredited certifier. Certified to be returned to service after the 4 hour cure time.
Certified to rehabilitate existing pipe. Certified for use on pipe intended for immediate return to service.

(y) - For use with tanks greater than or equal to 70,000 gallons not exceeding a surface area to volume ratio of 9.03 cm2/L. Mix
Ratio: For use only when Part A is mixed with Part B in a 2:1 parts by volume ratio; Number of Coats: 2 - 3; Maximum Dry Film
Thickness: 20 mils; Minimum Cure Time = 7 days @75F; Colors: Light grey (0700), White (0800), Light blue (0100), Black (0900),
Blue (6120), Gray (0794), and Tan (0200) ; Application Method = Spray with brush or roll for touch-ups; Maximum Thinner:
Carboline Thinner #2 or 225E, up to a maximum of 13 oz per gallon; Final Cure prior to water immersion: 7 days @ 75F. Note -
see manufacturer's instructions for additional product use information. This product was tested without an additional primer or
topcoat. It is recommended that any primer or topcoat used should be certified to ANSI/NSF Standard 61 by an ANSI accredited
certifier.

(z) - For use with tanks greater than or equal to 500 gallons not exceeding a surface area to volume ratio of 48.4 cm2/L. Mix
Ratio: For use only when Part A is mixed with Part B in a 100:121.7 parts by weight ratio; Number of Coats: 1; Maximum Dry
Film Thickness: 1.25 mils; Minimum Cure Time = 7 days @75F; Colors: gray; Application Method = Spray with brush or roll for
touch-ups; Maximum Thinner: N/A; Final Cure prior to water immersion: 7 days @ 75F.

Last Updated on 2019-11-14

The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.
The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their
entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from
the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the
reprinted material must include a copyright notice in the following format: "© 2020 UL LLC"

https://iq.ulprospector.com/en/profile?e=33872 Page 5 of 5