JV OF SHIRISH PATEL & ASSOCIATES CONSULTANTS PVT
LIMITED & INDUS CONSULTRANS PVT LTD.
CLIENT YFC PROJECT PVT LTD. CLIENT DMRC
CHECK LIST FOR SUBSTRUCTURE DESIGN (VIADUCT)
Document No 30.TA.VDT.DCL108 Date 5/8/2020
Contract Package - DC-04 (PHASE-IV ) Revision R2
Pier no. P92
Status/
SI.No. Description Checked Not Checked
Remarks
A Check for Levels
1 Rail top level shall be as per GAD √
2 Piercap top level √
3 Ground / Road Level as per GAD √
4 Pile cap top level √
5 Founding level as per GIR √
6 HFL & Scour Level √ Not Applicable
B Check for Geotechnical Requirements
1 Check for Vertical capacity of pile √
2 Check for Lateral capacity of pile √
3 Check for uplift √
4 Check for Pile Spacing √
5 Check for Overturning & Sliding for open foundation √ Not Applicable
6 Check for Bearing capacity of soil (for Open foundation) √ Not Applicable
7 Check for Contact area of open foundation √ Not Applicable
C Loads and load Factors
1 Dead load of Superstructure √
2 Superimposed dead load calculation √
3 Load of pier, pier cap , pedestal and seismic arrester √
4 Load of pile cap, protection barrier and earth above pile cap √
5 Live load including braking/tractive and centrifugal √
6 Bearing friction / Shear Rating √
7 Temperature including linear & gradient √ Not Applicable
8 LWR/Rail break load √
9 Prestress, creep & shrinkage, Relaxation, Friction& slip and elastic shortening √ Not Applicable
10 Differential shrinkage √ Not Applicable
11 Earth pressure & Live load surcharge √
12 Water current & Buoyancy √ Not Applicable
13 Seismic load √
14 Wind Load √
15 Vehicle collision load. √
16 Load factors √
17 Load Combination √
D Check for Analysis
1 Section Properties √
2 Boundary Conditions √
3 Verification of Soil Stiffness (Static and Dynamic) √
4 Model for time period analysis in seismic combination -Staad Model √
5 Foundation Analysis - River theory √
6 Static Analysis of Structure. √
7 Differential Settlement analysis √ NotApplicable
8 Dynamic analysis of structure (Response spectrum Analysis) √
9 RSI - LWR load considered as per Tender value √
E Check for Foundation design
1 of 2
Status/
SI.No. Description Checked Not Checked
Remarks
(i) Pile
1 Shear check in pile √
2 Check for Ultimate capacity of Pile (M/Mu) √
3 SLS Check of Pile (Crack width & Stresses) √
4 Check for Curtailment check. √
5 Check for Cover, Minimum & Maximum reinforcement & its spacing √
(ii) Pile Cap
1 Check for Minimum depth √
2 Pile Cap- Check for analysis- Bending theory √
3 Shear check in pile cap √
4 Check for Ultimate capacity of Pile cap (M/Mu) √
5 SLS Check of Pile Cap (Crack width & Stresses) √
6 Check for Punching shear √
7 Check for Cover, Minimum & Maximum reinforcement & its spacing √
(iii) Open Foundation design
1 Check for one way Shear √ Not Applicable
2 Check for Ultimate capacity (M/Mu) √ Not Applicable
3 SLS Check (Crack width & Stresses) √ Not Applicable
4 Check for Punching shear √ Not Applicable
5 Check for Cover, Minimum & Maximum reinforcement & its spacing √ Not Applicable
F Column/Pier/Abutment
(i) RCC Pier
1 Check for Slenderness √
2 Check for Ultimate capacity of Pier (M/Mu) √
3 SLS check (Crack width & Stresses) √
4 Ductile Detailing Check √
5 Shear Check √
6 Check for Cover, Minimum & Maximum reinforcement & its spacing √
G Reinforcement detailing
1 Cover Check √
2 Spacing Check √
3 Lap Length / Development / Anchorage Length √
4 Curtailment Length √
5 "L" Bent √
6 No L bent in pile at bottom √
7 Any Special Notes √
H Applicable Drawing number
1 Pile reinfoceme nt - 30.TA.VDT.4004
2 Pilecap Concrete profile - 30.TA.VDT.5001
3 Pilecap Reniforcement detail - 30.TA.VDT.5204
4 Pier Reniforcement detail - 30.TA.VDT.6004
5 General Arrangement drawing - 30.TA.VDT.3004
Checked By Reviewed By Approved By
PositionDesign Engineer Team Leader Project Leader
Name UMAR ARIF DEEPAK
Signature
Date 5/8/2020 5/8/2020 5/8/2020
2 of 2