Electronic card – 5710

Parameter Settings
T-code Valid from serial number
483,484,657,658,793,794 709569-
Date Order number
2004-09-20 217166-040

1.5 Parameter Settings


• Connect the service key to the truck.
• The switch I is pressed at the same time as the ignition key is
switched on.
• Step using II, to move up and III, to move down to the parameter
you wish to change.
• Press switch I the display will flash.
• Change the value using the switches II/III.
• Press switch I to set the value, the display will stop flashing.
To change more parameters, step using the switches II/III to the
parameter to be changed and repeat from “Press switch I the display
will flash”.
NOTE!
Truck operating characteristics.
Changing the truck-specific parameters changes the truck’s opera-
ting characteristics.
Do not change any parameters unless you have the necessary com-
petence.

No. Parameter type Unit Min./max. Std. Comments


value
01 Steering sensitivity 1–6 3 1 = Several wheel turns
5 = Few wheel turns
6 = No progressivity
In steps of 1
02 Drive motor, max. % 10–100 100 Percentage of max. speed
speed In steps of 5
03 Drive motor, acceler- % 10–100 100 Percentage of max. speed
ation In steps of 5
04 Drive motor, speed % 0–100 20 Percentage of speed retardation
retardation 50 > 0 = no retardation
Note 1: In steps of 5
05 Drive motor, retarda- % 35–100 80 Percentage of max. retardation
tion when reversing In steps of 5
10 PIN code for driver 0000–3333 0000 0000 = PIN code not used.
selection > 0 = PIN code used.
11 Drive motor, speed % 10–100 100 Percentage of max. speed
reduction In steps of 1

1- 84 © BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Anders-
Electronic card – 5710
Parameter Settings
Valid from serial number T-code
709569- 483,484,657,658,793,794
Order number Date
217166-040 2004-09-20

No. Parameter type Unit Min./max. Std. Comments


value
12 Masts out/in move- % 10–100 80 Percentage of max. speed
ment, speed In steps of 5
13 Extra function 1 % 10–100 10
speed
14 Extra function 2 % 10–100 20 As a percentage of the maxi-
speed mum oil flow
In steps of 5
15 Engaging hydraulic % 0–100 100 0 = not connected
extra function 1, cur- > 0 = connected
rent limit In steps of 5
16 Engaging extra func- % 0–100 0 0 = not connected
tion 2, current limit > 0 = connected
In steps of 5
17 Lift height limitation m 0–13,5 13,5 0 = not connected
level 1 > 0 = connected
In steps of 0.05
18 Lift height limitation m 0–13,5 13,5 In steps of 0.05
level 2 Set greater or equal to L.h. limi-
tation 1.
19 Forks’ free lift height m 1,0–4,5 2,2 Top side of fork to floor when
See inner guide is at top.
table In steps of 0.01
20 Time indication 1–5 2 1 = ignition time (A)
2 = total movement time (b)
3 = drive motor time (c)
4 = pump motor time (d)
5 = service time (S)
21 Battery size 1–20 12 See table
See
table
23 Type of Mast 0/1 1 0 = Mast tilt
1 = fork tilt
24 Left foot-switch 1/0 1 0 = Activates buzzer
1 = Also cuts drive motor
25 Service interval h 0–2000 100 0 = No service counter
In steps of 50h
26 Tilt speed % 10-100 30 In steps of 5

© BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Andersson 1- 85
Electronic card – 5710
Parameter Settings
T-code Valid from serial number
483,484,657,658,793,794 709569-
Date Order number
2004-09-20 217166-040

No. Parameter type Unit Min./max. Std. Comments


value
27 Lift priority 0/1 1 0 = Fork lift prioritised
1 = Fork lift not prioritised
28 Indication signal 0/1 0 0:
202 Pump motor
208 Drive motor
1:
202 Driving in drive wheel direc-
tion
208 Driving in fork direction
29 Maximum lifting m 0-13,5 13,5 0 = not connected
height > 0 = connected
In steps of 0.05
38 Calibration of accel- 1 0 Set to 1 for calibration
eration/brake pedal See instructions
and reach carriage
39 Driver access 1–4 1 1 = no PIN code, open
2 = no PIN code, locked
3 = PIN code, open
4 = PIN code, locked
40 Time, years Years 0–99 In steps of 1
41 Time, days Days 1–31 In steps of 1
42 Time, months Months 1–12 In steps of 1

1.5.1 Parameter 1
The higher the number you program, the less number of turns of the
steering wheel required to turn the drive wheel. With a value of 6, steer-
ing is non-progressive, less sensitive at higher speeds.

1.5.2 Parameter 2
This parameter sets the maximum permitted driving speed.

1.5.3 Parameter 3
The lower the number you program, the longer the truck will require to
come up to maximum speed.

1- 86 © BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Anders-
Electronic card – 5710
Parameter Settings
Valid from serial number T-code
709569- 483,484,657,658,793,794
Order number Date
217166-040 2004-09-20

1.5.4 Parameter 4
This parameter determines the force at which the truck will stop when
you release the accelerator pedal.
Note 1: Driver 1 has 20%, drivers 2-10 have 50% as the default value.

1.5.5 Parameter 5
With this parameter, you determine the force at which the truck will stop
when you change directions and use the drive motor to stop the truck.

1.5.6 Parameter 10
Value 0000 means that three drivers are chosen. The table below
shows the combinations for the first six PIN codes. These values are
attained by stepping up and down with the switches I and II.

Value Driver number


0000 No PIN code. Max. three drivers used
1111 First PIN code when max. 10 drivers used
1112 Second PIN code when max. 10 drivers used
1113 Third PIN code when max. 10 drivers used
1121 Fourth PIN code when max. 10 drivers used
1122 Fifth PIN code when max. 10 drivers used
1123 Sixth PIN code when max. 10 drivers used
etc. etc.

1.5.7 Parameter 11
This parameter sets the maximum permitted driving speed when switch
S31 is activated.

1.5.8 Parameter 12
With this parameter you can adjust the speed of the mast’s in and out
movement.

1.5.9 Parameters 13 to 14
With this parameter you can adjust the oil flow for the two extra func-
tions.

© BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Andersson 1- 87
Electronic card – 5710
Parameter Settings
T-code Valid from serial number
483,484,657,658,793,794 709569-
Date Order number
2004-09-20 217166-040

1.5.10 Parameters 15 and 16


When these parameters are set to the value> 0, control of potentiome-
ters and valves for the two extra functions are activated. Function
requirements are also stated by the size of the value.

1.5.11 Parameters 17 and 18


Using these parameters you can set two different maximum lifting
heights when the truck is equipped with a height meter. Maximum
height number two must be identical or higher than height number 1.
The maximum lifting height is specified using parameter 29.
If there is no height meter, the parameter must be set to 0.

1.5.12 Parameter 19
Lift height Coarse setting
M 16 mast with integrated side shift
4400 1,42
4600 1,50
4800 1,56
5400 1,75
5700 1,85
6300 2,07
6750 2,22
7000 2,42
7500 2,56
8000 2,74
8500 2,93
9000 3,09
9500 3,19
10000
10500
10800

1.5.13 Parameter 20
This parameter specifies the time A-d or S that will be displayed when
the driver uses the truck.

1- 88 © BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Anders-
Electronic card – 5710
Parameter Settings
Valid from serial number T-code
709569- 483,484,657,658,793,794
Order number Date
217166-040 2004-09-20

1.5.14 Parameter 21
With this parameter you specify the battery the truck is equipped with.
You may also compensate for different ways of driving.
For setting the battery monitor’s break point, measure as set out below:
• Acid density for fully charged battery. To check battery quality.
• When battery indicator shows 80% discharge, min. acid density 1.14.
The acid density can vary depending on the battery type.

Value Function Battery (Ah)


1
2
3
4
5
6
7
8
9
10

11 Less discharge 900


12 730, 700, 580 CSM
13 More discharge 600
14

15 480, 450
16
17 360
18
19
20

WARNING !
Correct parameter setting.
Battery can be destroyed.
If the parameters are set to values higher than those recommended,
battery discharge will be excessive and the batteries destroyed.

© BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Andersson 1- 89
Electronic card – 5710
Parameter Settings
T-code Valid from serial number
483,484,657,658,793,794 709569-
Date Order number
2004-09-20 217166-040

1.5.15 Parameter 23
When the parameter is set to 1 this defines that a valve is fitted to the
fork plank and is used as a switching valve between two functions.
Direction is handled by the valve in the large valve assembly.

1.5.16 Parameter 24
Set the parameter to 1 and you can stop the truck with the drive motor
but you cannot continue to drive, if the safety pedal is not depressed.

1.5.17 Parameter 25
With this parameter, you specify the truck’s service interval. The buzzer
sounds and C029 is shown on the display when the service counter is
at zero. The counter will show the time that has passed since the truck
was last serviced.
If the previous service time is to be used, only the parameter is activa-
ted the time is not changed.

1.5.18 Parameter 26
This parameter is used to set the maximum speed for the mast tilting.

1.5.19 Parameter 27
When the parameter is set to 1 this removes the lift function’s priority,
i.e. the hydraulic function being used will continue irrespective of
whether the lift is activated.

1.5.20 Parameter 28
This parameter allows information on the outputs 202 and 208 to be
switched between two different functions. 0 is for TLS and 1 is used to
start the warning light/buzzer when the truck is driven, an intermediate
relay must be used.

1.5.21 Parameter 29
When the truck is equipped with a height meter, you can specify the
maximum lifting height using this parameter. No bypass is possible. For
other information, see parameter 17 and 18.

1- 90 © BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Anders-
Electronic card – 5710
Parameter Settings
Valid from serial number T-code
709569- 483,484,657,658,793,794
Order number Date
217166-040 2004-09-20

1.5.22 Parameter 38
• Set the parameter to 1.
• Turn the ignition on and off once.
The acceleration and braking potentiometers will now be calibrated.
NOTE!
Calibration error.
Incorrect calibration value.
Do not move the lever when calibration begins.
• Retract the reach carriage towards the inner stop, battery partition.
• Move the reach carriage out to the outer stop.
The reach cylinder’s end position and lowering distance are now cali-
brated. The reach carriage’s movement will run at a reduced speed dur-
ing calibration.

1.5.23 Parameter 39
Set the parameter to 1 or 2 if only three drivers/truck profiles are to be
programmed. If up to ten drivers/truck profiles are to be programmed,
set the value to 3 or 4. With up to ten drivers, the value must be pro-
grammed for each driver. See parameter 10.
Show/programming choices with parameter 39.

Parame- Key S17 switched on, then Switch I and key S17 switched on
ter switch I simultaneously
P39- Clock Parameter Driver Clock Parameter Driver
-1 U. CAN Reprgm. See See selected Not reprgm. Reprgm. Selected
reprgm.
-1 M. CAN Reprgm. See See selected Not reprgm. Reprgm. All reprgm.
-2 U. CAN Reprgm. See See selected Not reprgm. Not reprgm. See
selected
-2 M. CAN Reprgm. See See selected Not reprgm. Reprgm. All reprgm.
-3 U. CAN Reprgm. See See selected Not reprgm. Reprgm. Selected
reprgm.
-3 M. CAN Reprgm. See See selected Not reprgm. Reprgm. All reprgm.
-4 U. CAN Reprgm. See See selected Not reprgm. Not reprgm. See
selected
-4 M. CAN Reprgm. See See selected Not reprgm. Reprgm. All reprgm.

© BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Andersson 1- 91
Electronic card – 5710
Parameter Settings
T-code Valid from serial number
483,484,657,658,793,794 709569-
Date Order number
2004-09-20 217166-040

1.5.24 Parameters 40 to 42
With these parameters you can set the year, day and month for error
code logging.

1.5.25 Other parameters


Other parameters between 10 and 42 are shown on the display and can
be programmed, but the value does not modify the program . Others
have a fixed value and cannot be reprogrammed.

1.5.26 Installing a new card in the truck


The A5 card from BT Parts can be supplied in different configurations:

1. Ready programmed with complete numbers and default val-


ues entered.
= P/N for the card including program.
2. Not programmed at part number
= only P/N for the card.
When installing a new card, certain parameters must be reprogrammed
so that the truck can be safely operated.
For downloading new programs to the electronic card, the Truck Com
service program is used.
See the Truck Com user manual for a description of the procedure.
Potentiometer R1 on the electronic card must be adjusted as per
C-code 6000.

1- 92 © BT Europe AB Service Manual REFLEX RR M12, M14, M16Approved by: K-G Anders-