You are on page 1of 7

ISOLATED FOOTING DESIGN (ACI-318)

Project :=
Engr := Uzair Ahmed

E-mail := engr.uzair2014@gmail.com
Design Code := ACI-318

can change these values


Units: US Customary

INPUT DATA :=
Column size (c1 x c2) = 24 x 12
fc' = 4000 psi
fy = 60000 psi

BC = 5.00 Ksf
Bottom R/F cover = 3.00 in

Service Ultimate SERVICE = 1.0 D + 1.0 SDL + 1.0 L


P (kip) = 385 558.25

Hx (kip) = 0 0
Hy (kip) = 0 0

Mx (k-ft) = 0 0
My (k-ft) = 0 0

Footing Design :=

Thickness - h Length - L Bredth - B Area Req. Area - A


(in) (ft) (ft) (ft2) (ft2)
24 13 9.25 77.00 120.25

Dimensions are ok
ex = (My + Hx h) / P = 0.00 in ey = (Mx + Hy h) / P =

Provided e = 0 in Provided e =
Column will not move Column will not move
Concentric Footing

d= 20.75 in

a= 66 in
b= 49.5 in
bo 1 = 44.75 in
bo 2 = 32.75 in
Punching Perimeter, bo = 155 in

Punching Area, Ao = 1465.56 in2

Bearing Pressure Check :=

Mx' = Mx + Hy h = 0.0 k-ft


My' = My + Hx h = 0.0 k-ft

q1 = P/A + 6 Mx' / L B^2 + 6 My' / B L^2 = 3.20 ksf


q2 = P/A - 6 Mx' / L B^2 + 6 My' / B L^2 = 3.20 ksf

q3 = P/A - 6 Mx' / L B^2 - 6 My' / B L^2 = 3.20 ksf


q4 = P/A + 6 Mx' / L B^2 - 6 My' / B L^2 = 3.20 ksf

Safe in Bearing Pressure

qu = Pu/A = 4.64 ksf

Punching Area Shear Area


Punching Check :=
Vu = Pu - qu * Ao = 511.00 kip

ΦVc = Φ4√ (fc′)bod = 610.24 kip


Adequate in Punching

Beam Shear Check :=


X-DIR

Vu = qu{L/2+ex-c1/2-d}B = 161.93 kip


ΦVd = Φ2√ (fc′)B d = 218.51 kip
Adequate in Shear Capacity

Reinforcement :=

Minimum Shrinkage R/F ratio = For fy < 60ksi 0.0020 Ag


For fy ≥ 60 ksi Greater of (0.0018*60000/fy) Ag or 0.0014 Ag

Direction Mu (k-ft) Ru (ksi) e As = e b d (in2)


X-Dir 70.2 0.1631 0.0028 0.6938

Y-Dir 39.5 0.0917 0.0016 0.3860

Bar # 4

Summary :=
Footing Type = Concentric Footing ex =
Footing Dimension = 13 x 9.25
Footing R/F =

Long Bar := # 4
Short Bar := # 4
= 1.0 D + 1.0 SDL + 1.0 L

Lever Arm - X Lever Arm - Y


(ft) (ft)
5.50 4.13
+ Hy h) / P = 0 in +ve e means column Bottom or Left movement

0 in -ve e means column Top or Right movement


will not move
Y-DIR

Vu = qu{B/2+ey-c2/2-d}L = 144.59 kip


ΦVc = Φ2√ (fc′)L d = 307.09 kip
Adequate in Shear Capacity

ACI 318R-14
Ag or 0.0014 Ag Table 8.6.1.1

e - min As - min (in2) As - use (in2)


0.0018 0.5184 0.6938

0.0018 0.5184 0.5184

No Ecentricity ey = No Ecentricity
x 2

@ 3 in c/c
@ 4 in c/c
or Left movement

ght movement

You might also like