Generator

Instruction
Manual
This manual has been designed to assist
qualified electricians to operate this
equipment safely and efficiently.

Only Authorised electricians may


operate this equipment

2
Daily Checks
These checks must be carried out before the generator is used

1 Engine oil level


2 Water level
3 Fuel level
4 Condition of drive belts
5 Condition of distribution points

Before starting the generator you must be aware of the following:

1 Position of the emergency stop switch.


2 What phase the generator is in (1 or 3 phase).
3 Operation of the control panel.
4 Loose or damaged cables.
5 Equipment is installed safely.
6 Hours left before service is due.

DO NOT USE
DAMAGED
EQUIPMENT OR
CABLES

3
4
5
Control Panel Messages

Gen-set operation state

Init Autotest during controller power on


Not ready Genset is not ready to start
Prestart Prestart sequence in process, Prestart output is closed
Cranking Engine is cranking
Pause Pause between start attempts
Starting Starting speed is reached and the Idle timer is running
Running Genset is running at nominal speed
Loaded Genset is running at nominal speed and GCB OPEN/CLOSE is closed
Stop Stop
Shutdown Shut-down alarm activated
Ready Genset is ready to run
Cooling Genset is cooling before stop
EmergMan Emergency Manual gen-set operation
AFterCool Engine aftercooling, CoolingPump output is closed

Electric state machine

MinStabTO Minimal Stabilization Timeout


MaxStabTO Maximal Stabilization Timeout
FwRet Brk Forward return break delay. Delay between GCB opening and MCB closing

List of possible alarms

Events specification Protection Information on binary output Description


type available (See list of Binary
outputs)
Oil Press Wrn WRN YES Oil pressure is smaller than Wrn Oil
press setpoint.
Oil Press Sd SD NO Oil pressure is smaller than Sd Oil
press setpoint.
Engine Temp Wrn WRN YES Water temperature is greater than Wrn
Water temp setpoint.
Engine Temp Sd SD NO Water temperature is greater than Sd
Water temp setpoint.
Fuel Level Wrn WRN YES Fuel level is smaller than Wrn Fuel
Level setpoint.
Fuel Level Sd SD NO Fuel level is smaller than Sd Fuel Level
setpoint.
Ubat WRN YES Battery voltage is out of limits given by
Batt overvolt and Batt undervolt
setpoints.
AnInIOM Wrn WRN YES Warning alarm configurable on the
input of IG-IOM/IGS-PTM.

6
Events specification Protection type Information on Description
binary output
available (See list
of Binary outputs)
AnInIOM Sd SD YES Shutdown alarm configurable on the
input of IG-IOM/IGS-PTM.
Binary input Configurable YES Configurable Warning/Shutdown alarms
on the inputs of IL-NT.
Battery flat SD YES If the controller switches off during
starting sequence due to bad battery
condition it doesn’t try to start again and
activates this protection.
Start failed SD YES Gen-set start failed.
ParamFail NONE NO Wrong checksum of parameters.
Happends typically after downloading
new firmware or changing of the
parameter. The controller stays in INIT
mode. Check all parameters, write at
least one new parameter.
Vgen <, > SD YES The generator voltage is out of limits
given by Gen <V and Gen >V setpoints.
Vgen unbl SD NO The generator voltage is unbalanced
more than the value of Volt unbal
setpoint.
Fgen <,> SD YES The generator frequency is out of limits
given by Gen >f and Gen <f setpoints.
Igen unbl SD NO The generator current is unbalanced.
Overload SD YES The load is greater than the value given
by Overload setpoint.
Overspeed SD YES The protection comes active if the speed
is greater than Overspeed setpoint.
Underspeed SD YES During starting of the engine when the
RPM reache the value of Starting RPM
setpoint the starter is switched off and
the speed of the engine can drop under
Start RPM again. Then the Underspeed
protection becomes active. Protection
evaluation starts 5 seconds after
reaching StartingRPM.
EmergencyStop SD NO If the input Emergency stop is opened
shutdown is immediately activated.
GCB fail SD NO Failure of generator circuit breaker.
PickupFault SD NO Failure of magnetic pick-up sensor for
speed measurement.
Stop fail SD YES Gen-set stop failed.
WrnServiceTime WRN NO The period for servicing is set by the
NextServTime setpoint. The protection
comes active if the running hours of the
engine reach this value.
ChrgAlternFail WRN YES Failure of alternator for charging the
battery.
SprinklActive WRN NO The protection is active if the output
Sprinkler is closed.
*Wrn RA15 fail WRN NO Warning alarm in case of lost connection
to IGL-RA15 module.
*Sd IOM fail SD NO Shutdown alarm in case of lost
connection to IG-IOM/IGS-PTM
Wrn ECU Alarm WRN NO ECU alarm list is not empty
Low BackupBatt WRN NO RTC backup battery is flat

7
Arri Lighting Distribution Box

Single Phase Operation- 160Kw

8
160Kw

9
200Kw

10
Generator Remote Monitoring

All generators can be remotely controlled and


monitored at our office in Uxbridge or ‘out in the field’
by our workshop staff.

This means when a generator is operating, we can


monitor the activity of the generator set and look at the
operating conditions whilst being operated.

The generator also records an operating history which


again can be viewed.

All the generators are capable of sending SMS


messages to warn us that a fault is occurring, these
messages are sent to:

 Transport Manager
 Generator Technician

For Technical assistance or to report a fault please


contact us on 01895 457200 or our ‘on call’ technician
on 07740 720828.

11
Remote Control
Main screen

This mirrors the main generator panel and shows the


basic operating parameters.

Breaker Status
Line Voltages
Line Amperes
Engine Speed
Generator Power Factor
Generator Kw being used
Engine Running Hours
Generator Loaded Running Hours
Battery Voltage
Engine Oil Pressure
Engine Temperature
Fuel Level
Alarm List
12
We can reset any Parameter or Set point within the set
if required.

Operators ARE NOT permitted to change the set from


single to three phase or vice versa.

Operators ARE NOT permitted to change any settings


within the control panel. Any damage caused, will be
charged to the production and could lead to the
operator not being permitted to use any equipment
belonging to Arri Lighting Rental in the future.

13
Risk Assessments

Detailed risk assessments must be carried out before


the generator and lighting rig is used; this is the
responsibility of the ‘Production Company’ as each
location will present different hazards.

These should be detailed and include the following


risks:

 Electric Shocks
 Generator Power Rating
 Power Supply
 Noise Pollution
 Distribution
 Safety Critical Measurements
 Cable Laying
 Radiation from Lamps
 Water Ingress
 Rigging
 Lighting Stands/Rigs
 Fire Risks – Heat from Lamps etc
 Emergency Procedures

The list above is a guide and not exhaustive. However


Health and Safety must be of paramount importance for
all concerned.

14
Generator Certificates

Electrical
All generators undergo a yearly comprehensive
electrical test.

This is to ensure the safe operation/wiring of the


generator set.

This test conforms to the following regulation:


BS7671 amended 2008

Noise
The generators have also undergone a ‘Noise Level
Test’ to ensure these meet minimum standards.

Low Voltage Directive


The generators are certificated to meet the
requirements laid down in the ‘Low Voltage Directive
73/23 / EEC’ and the ‘Electromagnetic Compatibility
Directive 89/336 / EEC’

Copies of the certificates can be supplied, please


contact our Transport Manager.

15
Arri Lighting Rental
4 Highbridge
Oxford Rd
Uxbridge
Middlesex
UB8 1LX

Tel: +44 (0) 1984 457221


Fax: +44 (0) 1984 457201

Sound Level Certificate


Vehicle:

Issue Date:
Expiry Date:

Engine Serial No: Generator Serial No:


Engine Type: Generator Type:

Testing device: Dawe Sound Meter D-1405E


Calibration Serial No: 12412534

This test is conducted in accordance with ISO 3746 (1995) for determination of sound
power levels of noise sources using sound pressure and a survey method using a
enveloping measurement surface over a reflecting plane.

The certified sound power is: ….. dBa @ 1m


….. dBa @ 3m
….. dBa @ 7m

Signed by:______________________________
Mr Keith Richens
Transport Manager

16
17
18
19