You are on page 1of 19

All-In-One Site Management.

Delivered.

© AIO Systems 2015/2016, all rights reserved. The content used in this document is strictly confidential and the proprietary property of their
respective owners. Specifications are subject to change without notice. This information is reliable at the point of creation and may be subject to
change.
TELECOMMUNICATION NETWORKS ARE DEPENDED
ON A RELIABLE ENERGY SOURCE;

MOST OF BTS SITES ARE IN REMOTE LOCATIONS


WHERE GRID POWER IS UNRELIABLE AND
INTERMITTENT POWER;

24/7 POWER  GRID INSTABILLITIES = INCREASE


GENERATOR USE = HIGH OF FUEL COST;

SERVICE LEVEL AGREEMENTS DEPENDS HEAVILY ON


CONTINUOUS BTS OPERATION. “SITE DOWN”
SHOULD BE ELIMINATED;

TELECOM NETWORK IS IN THE DIRE NEED FOR COST


EFFECTIVE BACK-UP POWER;

All-In-One Site Management.


2 Delivered.
POWER SOURCES:
> Power Grid
> Generators (DG);
> Backup Battery Banks;
> Green Energy Resources – Solar or Wind;
POWER CONSUMPTION:
> DC Power Site Assets;
> Air Conditioners;

THE SITE’S GEOGRAPHIC LOCATION & ENVIRONMENT GREATLY INFLUENCE POWER CONSUMPTION

All-In-One Site Management.


3 Delivered.
WE TAKE INTO ACCOUNT:
> Cost of diesel;
> Remote site accessibility;
> Environmental parameters: temperature, humidity, etc.;
> Grid availability and stability;
> Battery monitoring & available charge;
> Alternative energy (Solar, Wind);
> Grid power tariff structure;
> Availability of electricity switching systems, and more …

All-In-One Site Management.


4 Delivered.
SOLAR
THE SYSTEM AUTOMATICALLY SELECTS THE MOST EFFICIENT POWER SOURCE

MODES:
• AUTOMATIC (24/7)
• MANUAL (SCHEDULED)

EXAMPLE-
MODE: AUTOMATIC
OPTIMAL POWER SOURCE
SELECTION: BATTERY POWER
DURING OFF-PEAK HOUR RATE:
> AIO’s Hybrid Solution Commands Battery
Bank Charging;
> Site Powered Mainly by Grid;

DURING PEAK HOUR RATE:


> AIO’s Hybrid Solution Automatically
Selects Optimal Energy Source AT THE
LOWEST RATE(Battery Bank / Renewable
Source / Utility);
> AIO’s Controller Logs Each Change in
Site’s Power Source;

THE SITE’S POWER IS GUARANTEED 24/7 AT THE LOWEST RATE


AVAILABLE POWER SOURCES: GRID, GENERATOR,
BATTERY BANK;
WHEN GRID IS AVAILABLE:
> AIO’s Hybrid Solution Commands Battery Bank Charging;
> Site Powered by Cheapest Power Source – Grid;
WHEN GRID IS UNAVAILABLE:
> If Battery Bank Charged Above Threshold, AIO’s Hybrid
Solution Automatically Switches to Battery Bank (Cheapest
Available Power Source);
> Once Reaching Threshold, and if Grid is still unavailable, AIOs
Hybrid Solution Automatically Switches to Generator;
> When Operating on Generator, AIO’s Hybrid Solution
Commands not to Charge Battery Bank
> AIO’s Controller Logs Each Change in Site’s Power Source;
AVAILABLE POWER SOURCES: SOLAR, GRID, GENERATOR, BATTERY BANK
AVAILABILITY OF SOLAR SOURCE:
> AIO’s Hybrid Solution Commands to Use Solar Energy as the Primary Source, Due to it being the
Cheapest available Power Source;
> AIO’s Hybrid Solution Commands to Battery Bank Charging from Renewable Energy Source;
> When the Solar Source can not Supply all the Energy requirements, or is Unavailable at all (i.e. at
night times), AIO’s Hybrid Solution will Command to use other Power Sources;
WHEN GRID IS AVAILABLE:
> AIO’s Hybrid Solution Commands to add Grid power, as Needed;
> AIO’s Hybrid Solution Commands Battery Bank Charging, as Needed;
WHEN GRID IS UNAVAILABLE:
> If Battery Bank charged Above Threshold, AIO’s Hybrid Solution Automatically Switches to Battery
Bank which is the Cheapest Available Power Source;
> Once Reaching Threshold, and if Renewable Energy is Insufficient and Grid is still Unavailable, AIO’s
Hybrid Solution automatically switches to Generator;
> When Operating on Generator, AIO’s Hybrid Solution Commands not to charge Battery Bank;
> AIO’s Controller Logs Each Change in Site’s Power Source;
ALL THE HYBRID ASPECTS ARE BEING MONITORED FOR OPTIMUM
PERFORMANCE:
> Batteries: V & Amps;
> Environment: Temp & Humidity;
> Generator status;
> DC system and shelter optimization;
OPTIMAL USAGE OF SOLAR, BATTERIES, AND
DIESEL GENERATORS;
EXTENDED BATTERY LIFE-TIME;
RESULTS IN REAL-TIME FOR ROI CALCULATION;
OPERATION OF 3RD PARTY DEVICES TO PRODUCE THE CHEAPEST
ALTERNATIVE POWER AND MAXIMIZE ENERGY EFFICIENCY;
AIO SOLAR SOLUTION PROVIDES GREAT COST SAVING ADVANTAGES AND IMPROVED RELIABILITY.

Utilizing solar energy to charge site batteries cuts


dramatically on generator hours as well as grid,
thus lowering sites energy bill.

The solution is professionally engineered and


documented, and Factory manufactured under QA
supervision, providing enhanced reliability

Reduced field installation time and


installer expertise
GRID AC FEED MANAGEMENT:
> Control (turn on/turn off) all AC consumers on site – A/C, DC Supply Systems, Heaters;
> Deliver A/C status and Running Hours;
> Optimal Tariff Consumption – Switching To Battery On High Tariff Hours;
DC CONSUMERS MANAGEMENT:
> Monitor All Battery Statuses – Charge, Current, Temperature;
> Perform Remote Battery Capacity Testing;
> Monitor Consumer Behavior and Load;
> Turn Off DC Consumers on Low Efficiency and Switch to Battery Power;
DC GENERATORS & FUEL MANAGEMENT:
> Full control of Diesel Generator;
> Multiple Vendor GenSet Interoperability;
> Turn On/ Off, Failure Report;
> Deliver A/C status and Running Hours;
DC POWER GENERATION - (SOLAR / WIND ENERGY):
> Monitor and Manage Alternative DC Power Sources;
FAST ROI – WITHIN 12-24 MONTHS OF DEVELOPMENT:
> Reducing total energy consumed on site and carbon footprint;
> Introduction of green energy elements to site and their management;
> Using TOU tariff systems to optimize energy consumption;
> Removal or limited usage of DG for the sites having grid power for 8 to 10 hours;
> Reducing DG Running, Maintenance and Automation faults and minimizing O&M / AMC
Expense;
> Fuel consumption reduction and related expenses – refueling, pilfering, leakage;
> Removal or limited usage of A/C by deploying Free Cooling Units at indoor Sites;
> Reducing the cost of energy by using cheaper grid power for charging batteries;
> Increasing efficiency of consumption related to DC equipment;
> Reducing no. of field technician visits and increasing the site coverage per technician;
> Generation of metering, source of energy reports and remove disputes among
stakeholders;
> Designed for statutory green environment and pollution control requirements;
CONTACT US: info@aiosystems.com
www.aiosystems.com