You are on page 1of 3

LPG CYLINDER FILLING PLANT MACHINES UTILITY REUIREMENTS

1. CHAIN CONVEYORS.
 Made of a galvanized steel frame.
 CC600 cast iron chain is used.
 Electricity - Cable glands of each explosion proof electrical motor.
 Conveyor - Including all conveyor legs and concrete plug.

2. ROLLER CONVEYOR.
 Made of a galvanized steel frame.
 Galvanized steel rollers 50(diameter).
 Thickness 3 mm.
 Axes 12(diameter) (18 roller per meter).
 Each roller is equipped with balls bearings.
 Conveyor legs are included when it is not embedded to the concrete.

3. TARE WEIGHT ENCODING SYSTEM.

Consumptions.
 Air : 6,2 N liters / cylinder *4
 Electricity : 12V, 100mA max. (According To power supply 85-264VAC, 47-440HZ)

4. TANGEANTIAL PNEUMATIC ADMISSION.

Consumptions.
 Air : 0,04Nm3/cylinders with air pressure set at 6bars.
 Air : Quick drain valve of the air regulator - Ø1/2".

5. CAROUSEL SYSTEM

Consumptions.
 Air : Depends of the filling machines numbers used
 LPG : Depends of the filling machines numbers used
 Electricity 400Vac : 1,1kW.
 Electricity 230Vac : Maximum 0,8kW.
Limit of supply.
 Air : Male connection Ø1" – Gas type
 LPG : Counter flange – Ø3" ANSI 300
 Electricity 400Vac : Cable gland of the driving unit.
 Electricity 230Vac : Cable gland of the power supply.
6. ELECTRONIC FILLING SCALE ON CAROUSEL

Consumptions.
 Electricity : 12V, 100mA max. According to power supply 85264VAC,47-440HZ
 Air : 0.015Nm3 maximum per filling cycle.
Limits of supply.
 Air : Isolating valve - Ø1/4".
 Electricity : Electrical plug.
 LPG : Isolating valve Ø1/2".

7. ELECTRONIC CHECK SCALE.

Consumptions.
 Air : 7 Normal liters / cylinder with air pressure set at 6bars.
 Electricity : 12V, 100mA max. According to SIRAGA power supply 85264VAC, 47-
440HZ.
Limit of supply.
 Air : See technical description of Power Supply Panel.
 Electricity : See technical description of Power Supply Panel.

8. ELECTRONIC RESETTING CHECK SCALE.

Consumptions.
 Electricity : 12V, 100mA max. According to SIRAGA power supply 85264VAC,47
440HZ
 Air : 0.005Nm maximum per filling cycle.
Limit of supply.
 Air : See the power supply panel
 Electricity :See the power supply panel
 LPG :2 LPG flexible pipe, l=1.2 m, with isolating valve Ø ½" NPT

9. CONTROLLING UNIT.

Limit of consumptions.
 Air : Quick drain valve of the air regulator - Ø1/2".
 Electricity : Cable gland of the electrical power transformer.
Utilities.
 Air : See the description of the filling machine.
 Electricity : 0, 3 kW – 230 Vac (50 Hz).
10. AUTOMATIC VALVE LEAK + ORING DETECTOR.

Consumptions.
 Air : 0,015 Nm3 / cylinder with air pressure set at 6bars.
 Electricity : 230V, 50Hz.....: 0, 3 kW.
Limit of supply
 Air : Quick drain valve of the air regulator - Ø1/2".
 Electricity : Cable gland of power supply.

11. AUTOMATIC THERMO-SHRINKABLE SLEEVES MACHINE 1 HEAD.

Limit of supply.
 Air : Quick drain valve of the air regulator - Ø1/2".
 Elec : Cable gland of the electrical explosion proof control panel.
Consumptions.
 Air : 2, 4 Normal liters / cylinder with air pressure set at 6bars.
 Elec : 6,18Kw.

12. LPG PRESSURE REGULATING SKID

Limit of supply
 LPG inlet. : Counter-flanges Ø 3” PN40 RF.
 LPG return line. : Counter-flanges Ø 2" PN40 RF.
 LPG outlet : Counter-flanges Ø 3" PN40 RF.
 Radiography : 10%.

13. MANUAL ORING LEAK TESTER DUAL HEADS

Limit of supply
 Compressed air : quick drain valve for the air regulator -Ø1/2"
Standard performances.
 Leak sensitivity : 0.5 g of LPG
Special requirements.
 Installation : on conveyor
 Conveyor : chain conveyor (level=+480mm)
 Cylinder stop unit : 2