1. CHAIN CONVEYORS.
Made of a galvanized steel frame.
CC600 cast iron chain is used.
Electricity - Cable glands of each explosion proof electrical motor.
Conveyor - Including all conveyor legs and concrete plug.
2. ROLLER CONVEYOR.
Made of a galvanized steel frame.
Galvanized steel rollers 50(diameter).
Thickness 3 mm.
Axes 12(diameter) (18 roller per meter).
Each roller is equipped with balls bearings.
Conveyor legs are included when it is not embedded to the concrete.
Consumptions.
Air : 6,2 N liters / cylinder *4
Electricity : 12V, 100mA max. (According To power supply 85-264VAC, 47-440HZ)
Consumptions.
Air : 0,04Nm3/cylinders with air pressure set at 6bars.
Air : Quick drain valve of the air regulator - Ø1/2".
5. CAROUSEL SYSTEM
Consumptions.
Air : Depends of the filling machines numbers used
LPG : Depends of the filling machines numbers used
Electricity 400Vac : 1,1kW.
Electricity 230Vac : Maximum 0,8kW.
Limit of supply.
Air : Male connection Ø1" – Gas type
LPG : Counter flange – Ø3" ANSI 300
Electricity 400Vac : Cable gland of the driving unit.
Electricity 230Vac : Cable gland of the power supply.
6. ELECTRONIC FILLING SCALE ON CAROUSEL
Consumptions.
Electricity : 12V, 100mA max. According to power supply 85264VAC,47-440HZ
Air : 0.015Nm3 maximum per filling cycle.
Limits of supply.
Air : Isolating valve - Ø1/4".
Electricity : Electrical plug.
LPG : Isolating valve Ø1/2".
Consumptions.
Air : 7 Normal liters / cylinder with air pressure set at 6bars.
Electricity : 12V, 100mA max. According to SIRAGA power supply 85264VAC, 47-
440HZ.
Limit of supply.
Air : See technical description of Power Supply Panel.
Electricity : See technical description of Power Supply Panel.
Consumptions.
Electricity : 12V, 100mA max. According to SIRAGA power supply 85264VAC,47
440HZ
Air : 0.005Nm maximum per filling cycle.
Limit of supply.
Air : See the power supply panel
Electricity :See the power supply panel
LPG :2 LPG flexible pipe, l=1.2 m, with isolating valve Ø ½" NPT
9. CONTROLLING UNIT.
Limit of consumptions.
Air : Quick drain valve of the air regulator - Ø1/2".
Electricity : Cable gland of the electrical power transformer.
Utilities.
Air : See the description of the filling machine.
Electricity : 0, 3 kW – 230 Vac (50 Hz).
10. AUTOMATIC VALVE LEAK + ORING DETECTOR.
Consumptions.
Air : 0,015 Nm3 / cylinder with air pressure set at 6bars.
Electricity : 230V, 50Hz.....: 0, 3 kW.
Limit of supply
Air : Quick drain valve of the air regulator - Ø1/2".
Electricity : Cable gland of power supply.
Limit of supply.
Air : Quick drain valve of the air regulator - Ø1/2".
Elec : Cable gland of the electrical explosion proof control panel.
Consumptions.
Air : 2, 4 Normal liters / cylinder with air pressure set at 6bars.
Elec : 6,18Kw.
Limit of supply
LPG inlet. : Counter-flanges Ø 3” PN40 RF.
LPG return line. : Counter-flanges Ø 2" PN40 RF.
LPG outlet : Counter-flanges Ø 3" PN40 RF.
Radiography : 10%.
Limit of supply
Compressed air : quick drain valve for the air regulator -Ø1/2"
Standard performances.
Leak sensitivity : 0.5 g of LPG
Special requirements.
Installation : on conveyor
Conveyor : chain conveyor (level=+480mm)
Cylinder stop unit : 2