No Equipment Desc

15 Flame scanner test lamp

16 Flame scanner test lamp


Air compressor 390
19
SCFM

20 Breathing apparatus
22 Torque wrench

Explosion proof camera /


23
handphone

Industrial electric portable vacuum


24
cleaner

25 Pipe Cold Cutter Manual

26 PWHT Equipment
28 Welding Engine

29 Portable welding machine


30 Lighting tower

31 Air compressor
32 Air dryer

33 Air blower
34 Personal gas detector

35 Area gas detector


Refractory gunning machine and mixer
36
set

37 Hydraulic power unit

38 Lapping machine
38 Generator set PR MR AGRU 75 KVA

39 Generator set MCHE 125 KVA


40 Generator set Blast Tent 125 KVA
LIST EQUIPMENT

Specification

1. Product reference: MSA TL105


2. Output Spectrum: Broadband emissions in UV, visible and IR spectra
3. Charging Time: 3.5 hours max.
4. Electrical Specification: 12 VDC 130 W max.
5. Charger input: 110-240VAC, 50/60 Hz@ 1.5A
6. Charger output: 24 VDC @ 2.1A
7. Classification:
o C lass I, Division 1 & 2, Groups C & D
o Ex tb IIIC T110°C Db o Ex d IIB + H2 T4 Gb
8. Operating Temperature range: 5°F to +122°F (-15°C to +50°C)
9 . Charging Temperature: 32°F to +104°F (0°C to +40°C)
10. Humidity 10-90% ±3% RH, non-condensing
11. Length: 13 inches (330 mm)
12. Diameter: 5 inches (127 mm)
13. Weight: 7.9 lbs (3.5 kg)
14. Approvals: CSA, ATEX, IECEx, CE Marking

1. Product reference: MSA TL105


2. Output Spectrum: Broadband emissions in UV, visible and IR spectra
3. Charging Time: 3.5 hours max.
4. Electrical Specification: 12 VDC 130 W max.
5. Charger input: 110-240VAC, 50/60 Hz@ 1.5A
6. Charger output: 24 VDC @ 2.1A
7. Classification:
o C lass I, Division 1 & 2, Groups C & D
o Ex tb IIIC T110°C Db o Ex d IIB + H2 T4 Gb
8. Operating Temperature range: 5°F to +122°F (-15°C to +50°C)
9 . Charging Temperature: 32°F to +104°F (0°C to +40°C)
10. Humidity 10-90% ±3% RH, non-condensing
11. Length: 13 inches (330 mm)
12. Diameter: 5 inches (127 mm)
13. Weight: 7.9 lbs (3.5 kg)
14. Approvals: CSA, ATEX, IECEx, CE Marking
1. Diesel engine driven complete with silent compartment and certified spark arrestor
2. Capacity 390 SCFM with discharge pressure up to 10 bars
3. Non-hazardous classification
4. Minimum IP56 complete with certificate
5. Complete with lifting frame and set as specified in COMPANY’s onshore CCU specifications
6. Complete with safety protection features (trip & alarm) such as over speed, low lube oil pressure, high engine temperat
low fuel level and Emergency Shutdown (ESD) push button
7. Complete indicators to monitor operating parameters such as flow rate, pressure, speed, lube oil pressure, engine
temperature, fuel level
8. Each compressor shall complete with air distribution package including feed air hoses (Min 3/4” + 15 rolls x 20 meters
roll), manifolds with quick connect and water traps (2 EA), hose whip check, fittings, connectors, pressure gauges, regu
with, etc.
9. Suitable and sufficient to operate minimum five (5) hydraulic bolt torquing/tensioning pumps
10. Drip pan
11. Grounding cables completed with clamps
12. Equipment’s fast moving spare part (filters, hydraulic hoses, water trap spares such as cartridge with using cartridge s
etc) & consumables for any contingencies
13. Emission gas compliance to environmental minister regulation no.13/2009

One (1) set of breathing apparatus EQUIPMENT supplied by CONTRACTOR shall consist of the followings:
1. One (1) air supply trolley unit (brand – Scott Safety) suitable for 2ea x Scott Safety air cylinder (cap. 6-7 liters 300 bars p
cylinder), fully adjustable cylinder bands, stainless steel tubular frames with wheels, handles, moulded hose reel drum
including anti-static airline hose (60 meters) complete with CEN couplings for up to 2-man use, valves, regulators and
suitable for Scott Safety Vision 3 positive pressure face mask supplied below
2. Four (4) carbon fibre fully wrapped aluminium composite cylinders (brand – Scott Safety) with capacity
6-7 liters 300 bars per cylinder, CE
specifications, CEN couplings, cylinder valves incorporating safety locking hand wheel.
3. Additional anti-static airline supply hose (60 meters) (brand – Scott Safety or equivalent) complete with male and fema
CEN couplings and suitable for Scott Safety Vision 3 positive pressure face masks supplied
4. One (1) Y-piece complete with CEN couplings (brand – Scott Safety)
5. Two (2) positive pressure face masks (brand – Scott Safety type Scott Vision 3) with 5-point fully adjustable neoprene
head harness, bayonet connection for demand valve
6. Two (2) FLITE airline apparatus (brand – Scott Safety type FLITE). Each apparatus shall include bandolier and hip
mounted cylinder harness (suitable for Scott Safety FLITE cylinder), 1ea x 2 liters 200 bars cylinder (brand – Scott Safet
FLITE), CE specifications, tempest automatic positive pressure demand valve, regulator, supply hose and pigtail with CE
couplings, suitable for Scott Safety Vision 3 positive pressure face mask
7. One (1) complete set of high-pressure stationary air compressor include a compatible cascade system and filling station
following specific details:
Charging Rate : > 680 l/min
Pressure : 225/330 bar with 2 selectable modes
Filling hose : 2x200 and 2x300 bar
Filling Valve : Include 4 (four) filling valves 200 & 300 bar (*) Motor : 3 (three) phase(s)
Electrical Power : 15 kW(400V-50/60Hz) connected with socket outlet type 3P+N 32A - electric cable minimum 5 meters
Sound level : Silent Mode < 75 dB(a)
1. Tohnichi/Proto/Elora/Stanley or equivalent
2. KAN certified
3. Square driver 3/8” with range 10-100 Nm (3 + 13)
4. Square driver 1/2” with range 20-100 Nm (3 + 13)
5. Square driver 1/2” with range 40-200 Nm (3 + 13)
6. Square driver 1/2” with range 50-250 Nm (3 + 13)
7. Square driver 1/2” with range 70-350 Nm (3 + 13)
8. Square driver 3/4” with range 60-300 Nm (3 + 13)
9. Square driver 3/4” with range 100-750 Nm (3 + 13)

i.safe IS540.1 or equivalent


2. Intrinsically safe for use in zone 1 / division 1
3. Ex ATEX certified
4. Protection class IP68
5. OS: Android 10 or higher
6. Support MS Teams application
7. Mandatory to be registered at KOMINFO
8. Support magnetic USB connector plug
9. Support using with dirty or wet work gloves touch screen
10. Support Outdoor Visibility
11. Minimum camera 8 MP auto focus rear

1. Numatic NTD750 or equivalent


2. Motor TwinFlo, 2 x 1060 W, 230V AC 50/60Hz
3. Airflow 98 L/sec, Suction 2400 mm H2O
4. Capacity 35 L, Cleaning Range 26.8 m
5. Complete with fittings and connector

1. Model: OCP-325 Neumatic and/or OCP-508 Neumatic or equivalent


2. Working range (ID-OD in inch): 6-12 and/or 14-20
3. Driven: Pneumatic
4. Air Supply: 0.6-0.8 Mps@1500-2000 L/min

PWHT Equipment complete with ceramic heating pads (18 ea)


1. Primary Input Supply Voltage & Current: 50kVA units : Three phase, 380V (75A), 415V (69A) or 440V (65A)
2. Frequency: 50/60Hz
3. Secondary Output Voltage: 65V a.c.
4. Transformer Coil: 50kVA unit : 50kVA Natural air cooled, class H
5. Thermocouple Input and Output: Type K (NiCr/NiAl)
6. Protection: Over temperature sensor in each winding and three phase MCCB with shunt trip
7. Design Standards: EMC: EN 61326: 1998, LVD: EN 61010-1: 2001
1. Diesel engine complete with certified spark arrestor type – brand Miller Big Blue 500X model or equivalent complete w
certified spark arrestor, adjustable ampere switch, drip pan and grounding
2. Minimum IP56 complete with certificate
3. Forklift pocket frame
4. The following set accessories shall be included:
a. Welding cables (100 meters) – outer rubber jacketed stranding cable, minimum AWG 3/0 or equivalent with minimum
0.423” bare conducted OD and suitable length
b. Cable connectors or splicers – fibre or neoprene insulators, suitable for AWG 3/0 or equivalent. Splicer for permanent
connector shall use cast Copper-Alloy with soldering, brazing or mechanically joining and use hard fibre insulator.
c. Cable lugs – cast Copper-Alloy suitable for AWG 3/0 and use hard fibre insulator
d. Cable ground clamps – Jackson double-lock model GC-4 suitable for AWG 3/0 or equivalent
e. Grounding cables – as per welding machine requirement
f. Electrode holders – medium size model Jackson AW-CX or equivalent and suitable for electrode size 0.24” and 300 A a
hard fibre insulator
g. Electrode holders for carbon gouging (CAC-G) – Jackson Jet- Arc II model general-purpose gun or equivalent
h. Oxygen and Acetylene regulators
i. TIG Holders 300 AMP complete with ceramic and tungsten electrode (dia.2.4mm) including hoses and cables
j. Flow meter complete with pressure gauge (4000 psi) for argon gas
k. Portable tang (ampere) meter
l. Electrode Oven – as per electrode manufacturer
m. Portable electrode oven – as per electrode manufacturer
5. Residual Current Circuit Breaker (RCCB)
6. Welding set accessories supplied above shall be suitable for safe operations of welding machines
7. Emission gas compliance to environmental minister regulation no.13/2009

1. ESAB Buddy Arc 400i series or equivalent


2. Portable inverter welding machine
3. Welding type – MMA/TIG
4. Input voltage – 400V, 3 phase, 50/60Hz
5. Input current – 20 – 28A
6. Output Load max – 400A
7. Use only electrical socket (male) connector model BP 360, 3P+E, current 63A, Vmax 500V, certified for Zone1/Zone2
EEx d IIC II2G, Manufacture Co.Si.Me
8. Dimensions – not exceed 600mm in each length, width, and height
9. Application class – S
10. Standards – IEC 60974-1 and IEC 60974-10
11. Residual Current Circuit Breaker (RCCB)
12. Welding set accessories supplied:
13. Welding cables (100 meters) including connectors/splicers, lugs
14. Grounding cables and clamps
15. Welding torches
16. Electrode holders
17. Portable tang (ampere) meters
1. Compact trailer mounted lighting unit type complete with wheel stoppers, certified lifting points, four (4) point
stabilization legs, certified spark arrestor
2. Diesel engine – non-hazardous type. Complete with certified spark arrestor
3. Four (4) metal Halide lamps at 1000-1500 watts per lamp
4. Extendable mast up to 9 meters
5. Rotatable lights for 360-degree coverage
6. Minimum IP56 complete with certificate
7. Grounding cables completed with clamps
8. Emission gas compliance to environmental minister regulation no.13/2009

1. Diesel engine driven complete with silent compartment and certified spark arrestor
2. Capacity 750 SCFM with discharge pressure up to 10 bars
3. Non-hazardous classification
4. Minimum IP56 complete with certificate
5. Complete with lifting frame and set as specified in COMPANY’s onshore CCU specifications
6. Complete with safety protection features (trip & alarm) such as over speed, low lube oil pressure, high engine
temperature, low fuel level and Emergency Shutdown (ESD) push button
7. Complete indicators to monitor operating parameters such as flow rate, pressure, speed, lube oil pressure, engine
temperature, fuel level
8. Each compressor shall complete with air distribution package including feed air hoses (Min 3/4” + 15 rolls x 20 me
each roll), manifolds with quick connect and water traps (2 EA), hose whip check, fittings, connectors, pressure gauges, reg
with, etc.
9. Suitable and sufficient to operate minimum five (5) hydraulic bolt torquing/tensioning pumps
10. Drip pan
11. Grounding cables completed with clamps
12. Equipment’s fast moving spare part (filters, hydraulic hoses, water trap spares such as cartridge with using cartridge sy
etc) & consumables for any contingencies
13. Emission gas compliance to environmental minister regulation no.13/2009
1. Portable air dryer for air outlet capacity min 800CFM and suitable for supporting 750 SCFM air compressor
2. Output air Dew Point -40 degC / 633 ppm
3. Complete set with 5 x 15 m hoses, adapter, whip-check, accessories with spark arrestor
4. Equipment’s fast moving spare part (filter cartridge and other consumables for any contingencies
5. Cable ground completed with clamps

1. Coppus RF-12 Reaction Fan Air Blower (Pneumatic air driven) or equivalent with Connection 3/4" Dixon Chicago Co
for air supply
2. Outlet flow of 2,100 to 5,100 cfm (3,566 to 8,665 m3/hr) at 80 psig air driven
3. Use for fresh air supply or fume exhaust
4. Low compressed air consumption
5. Spark-resistant, cast-aluminium housing and fan blade
6. Handle & support equipped at body
7. Each blower to be completed with:
- Air driven supply regulator
- ¾” Air supply hoses 5 x 20 m with Chicago Quick Coupling Connection
- Blow air duct with (5 x 20 m)
1. MSA Altair 5X with pump and probing or equivalent
2. MSA Altair 5X IR (Infra-Red) with pump and probing or equivalent
3. MSA Altair 4X or equivalent
4. Each type of gas detector shall be equipped with bump test station completed with consumable gas (mixed gas) for da
bump test during all TAR or Campaign duration
5. General specifications for all types above include:
a. Sensor gas readings:
• CH4 – Methane (IR %vol or non-IR %LEL)
• O2 – Oxygen (%vol)
• CO – Carbon Monoxide (ppm)
• H2S – Hydrogen Sulphide (ppm)
b. Explosion proof (EX) standards complete with certificates:
- IEC – Ex ia d IIC T4 Gb
- ATEX – Ex II 2G Ex ia IIC T4 Gb
- CSA – Class I Div 1 Groups ABCD T4, Class 1 Zone 1 Ex ia d IIC T4
- MED – (0038/YY) Modules B & E, A.1/3.30
CE
6. IP67 complete with certificates
7. Audible, visual, and vibrating alarm features
8. Rechargeable battery with running time > 14 hours
9. Charging unit complete with cable (100-240 VAC, 50-60 Hz
10. Calibrated complete with certificates

1. Oldham BM25 or Drager X-dock 5300/6300/6600 or equivalent


2. Equipped with bump test station completed with consumable gas
(mixed gas) for daily bump test during all TAR or Campaign duration
3. Sensor gas readings:
- CH4 – Methane (IR %vol or non-IR %LEL)
- O2 – Oxygen (%vol)
- CO – Carbon Monoxide (ppm)
- H2S – Hydrogen Sulphide (ppm)
4. Explosion proof (EX) standards complete with certificates:
- IEC – Ex ia d IIC T4 Gb
- ATEX – Ex II 2G Ex ia IIC T4 Gb
- CSA – Class I Div 1 Groups ABCD T4, Class 1 Zone 1 Ex ia d IIC T4
- MED – (0038/YY) Modules B & E, A. 1/3.30
- CE
5. IP67 complete with certificates
6. Audible, visual, and vibrating alarm features
7. Rechargeable battery with running time > 14 hours
8. Charging unit complete with cable (100-240 VAC, 50-60 Hz
9. Calibrated complete with certificates
1. Gunning machine pneumatic driven type – Aliva 246 or equivalent
2. Conveying output 0.4 – 3.2 m3/h
3. Maximum conveying distance 150 meters (horizontal) and 70 meters (vertical)
4. Refractory hose 40 meters / roll
5. Refractory mixer, air hose, drain separator (air / water separator tank), water ring, water hold, couplings, and othe
consumable items included
6. Cable ground completed with clamps

1. Electric driven motor, 10 horsepower, 3-phase, 380 V


2. Pump capacity 90-120 litters per minute
3. Maximum pressure 210 bars
4. HPU final connection – 1/2” BSPT
5. Suitable cable glands for non-armoured cables complete with lock nuts, earth tags, UP washers included
6. Power cables and junction box included. Requirements as follows:
7. Junction boxes complete with additional one (1) terminal block for neutral phase corresponding to existing power
connection (with neutral phase)
8. Termination inside junction box and motor terminal shall use cable lugs (ferrule, pin, or ring type)
9. Junction box to motor terminal – 0.6/1 kV Cu/PVC/PVC, 3C+E –
minimum size 6mm2 (RED, YELLOW, BLUE, GREEN).
10. Cable ground completed with clamps
11. Junction box to COMPANY’s socket outlet – 0.6/1 kV Cu/PVC/PVC,
4C+E – minimum size 6mm2 (RED, YELLOW, BLUE, GREEN)
12. Use only electrical socket (male) connector model BP 360, 3P+E, current 63A, Vmax 500V, certified for Zone1/Zone2
EEx d IIC II2G, Manufacture Co.Si.Me
13. 3P+N+E 32 Amp
14. Brand ITAL SMEA for hazardous area and weatherproof

1. Lapmaster or equivalent
2. Size up to 24 inch
3. Three conditioning rings with roller yoke and bearing assemblies to facilitate in-process plate flatness control
4. Abrasive feed system designed for water or oil-based lapping slurries
5. Automatic digital cycle timer
6. Electrical system voltages 100-240 VAC, 50-60 Hz
Detail Diesel Engine Generator specification shall refer to Doc No. 420-SPE-EL-5001. It shall be completed with 1 unit distri
panel with following specification:
- Industrial type, metal enclosed, sheet steel 2 mm, wall mounted, RAL 7032
- Operating Voltage 220V (1ph)/380V (3ph)
- Ingress Protection minimum IP55
- Cable entry shall be at the bottom side
- Dimension and capacity shall be advised by Vendor
- Incoming breaker shall be sufficient to accommodate Diesel Engine Generator maximum capacity
- Incoming cable size shall be provided by Vendor, cable size shall be able to accommodate maximum generator capacity a
accordance with incoming breaker size
- Outgoing breaker shall be as following:
a. 6 ea MCB 2P 16 Amp
b. 4 ea MCB 3P 63 Amp
- Outgoing feeder shall be completed with outdoor socket as following:
a. 6 ea wall mounting socket 220V, 2P+E, 16 Amp including electrical plug, min IP 55 for outdoor installation
b. 4 ea wall mounting socket 380V, 3P+E, 63 Amp including electrical plug, min IP 55 for outdoor installation

Detail Diesel Engine Generator specification shall refer to Doc No. 420-SPE-EL-5001. It shall be completed with 1 unit distri
panel with following specification:
- Industrial type, metal enclosed, sheet steel 2 mm, wall mounted, RAL 7032
- Operating Voltage 220V (1ph)/380V (3ph)
- Ingress Protection minimum IP55
- Cable entry shall be at the bottom side
- Dimension and capacity shall be advised by Vendor
- Incoming breaker shall be sufficient to accommodate Diesel Engine Generator maximum capacity
- Incoming cable size shall be provided by Vendor, cable size shall be able to accommodate maximum generator capacity a
accordance with incoming breaker size
- Outgoing breaker shall be as following:
a. 2 ea MCB 2P 16 Amp
b. 2 ea MCB 3P 63 Amp for Electrical Welding Lincoln Aspect TIG 375 & 1 spare
c. 2 ea MCB 2P 125 Amp for Electrical Welding Lincoln Precision TIG 375
- Outgoing feeder shall be completed with outdoor socket as following:
a. 2 ea wall mounting socket 220V, 2P+E, 16 Amp including electrical plug, min IP 55 for outdoor installation
b. 2 ea wall mounting socket 380V, 3P+E, 63 Amp including electrical plug, min IP 55 for outdoor installation
c. 2 ea wall mounting socket 220V, 2P+E, 125 Amp including electrical plug, min IP 55 for outdoor installation
Detail Diesel Engine Generator specification shall refer to Doc No. 420-SPE-EL-5001. It shall be completed with 1 unit distri
panel with following specification:
- Industrial type, metal enclosed, sheet steel 2 mm, wall mounted, RAL 7032
- Operating Voltage 220V (1ph)/380V (3ph)
- Ingress Protection minimum IP55
- Cable entry shall be at the bottom side
- Dimension and capacity shall be advised by Vendor
- Incoming breaker shall be sufficient to accommodate Diesel Engine Generator maximum capacity
- Incoming cable size shall be provided by Vendor, cable size shall be able to accommodate maximum generator capacity a
accordance with incoming breaker size
- Outgoing breaker shall be as following:
a. 8 ea MCB 2P 16 Amp
b. 8 ea MCB 3P 63 Amp
- Outgoing feeder shall be completed with outdoor socket as following:
a. 8 ea wall mounting socket 220V, 2P+E, 16 Amp including electrical plug, min IP 55 for outdoor installation
b. 8 ea wall mounting socket 380V, 3P+E, 63 Amp including electrical plug, min IP 55 for outdoor
installation
T

Inspection and Verification Requirements

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test
3. Documentation: manual books, manufacturing certificates, calibration
certificates, IP certificates, EX certificates

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test
3. Documentation: manual books, manufacturing certificates, calibration
certificates, IP certificates, EX certificates
1. Air compressor – function test and performance test for two (2)
hours
2. Hose package installed with fittings, connectors and manifolds –
100% successfully pressure tested (e.g hydrotest or pneumatic test)
3. Measuring devices (e.g. pressure gauges) – calibrated by reputable third-party
company/in-house accredited by National Accreditation Committee (KAN) or
equivalent
4. Pressure relief valves - calibrated
5. Indicators (as described above) – function test
6. Safety protection features (as described above) – trip test
7. ESD – function test
8. Primary Injection test for breaker
9. Documentation:
a. Manufacturing certificates, maintenance records b. Testing reports,
c. Manual books d. Spark arrestor
e. Primary Injection for MCCB
f. Calibration cert for instrumentation/ measuring device g. IP certificates
h. Lifting point/Frame or Lifting Gears must be accompanied lifting design
calculation; COC & TER (Thorough Examination Report) by LEEA third party
inspector & its company.

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test – overall breathing apparatus EQUIPEMENT system both using
airline from trolley unit and FLITE apparatus units. CONTRACTOR shall supply and
provide any materials and consumables required (e.g. gas test) for this purpose.
3. Hose and couplings – 100% successfully pressured testing
4. Documentation requirements:
a. Certificate of Conformity (COC) issued by manufacturing for air supply
trolley unit, hoses, couplings, Y-piece, cylinders, positive pressure face mask,
FLITE airline apparatus
b. Acceptance certificates issued by Disnaker for cylinders. CONTRACTOR shall
also comply to COMPANY’s procedure no. 900- PRC-HS-2232 “Compressed Gas
Cylinder Procedure”
1. Visual and dimensional checks (e.g., corrosion free, no structural damage)
2. Function test
3. Documentation – calibration report, manual books

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test
3. Documentation – EX ATEX certificate, manual books

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test
3. Documentation – manufacturing certificates, maintenance records, testing
reports, manual books

1. Visual and dimensional checks (e.g. corrosion free, no structural damage)


2. Function test
3. Documenation: manufacturing certificates, maintenance records, testing
reports, manual books.

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test
3. Documentation – calibration report, manual books
1. Visual and dimensional checks (e.g., corrosion free, no structural damage)
2. Function and/or performance test report.
3. Document verification. The following documentation shall be made
available:
a. Manufacturing certificates
b. Maintenance records
c. Calibration Certificate forinstrumentation / measuring device.
d. Testing reports
e. Spark arrestor and IP certificates
f. Emission gas test report
g. ATEX/Ex Certificate if Required.
h. Primary injection report for MCCB in panel If required.
i. Lifting point/Frame or Lifting Gears must be accompanied lifting design
calculation; COC & TER (Thorough Examination Report) by LEEA third party
inspector & its company.

1. Welding machine – performance test


2. Welding set accessories – function test
3. Residual Current Circuit Breaker (RCCB) – function test
4. Documentation
a. Manufacturing certificates, b. Maintenance records,
c. Primary injection for MCCB if required
d. Testing reports, e. Manual books
f. ATEX certificate if require
1. Lighting tower – performance test including tower extension and lamp
rotation
2. Lighting tower – illumination test
3. Documentation – manufacturing certificates, maintenance records, testing
reports, manual books and spark arrestor and IP certificates, Emission gas test
4. Indicators (as described above) – function test
5. Safety protection features (as described above) – trip test
6. ESD – function test
7. Primary Injection test for breaker
8. Lifting point/Frame or Lifting Gears must be accompanied lifting design
calculation; COC & TER (Thorough Examination Report) by LEEA third party
inspector & its company.

1. Air compressor – function test and performance test for two (2) hours
2. Hose package installed with fittings, connectors and manifolds – 100%
successfully pressure tested (e.g hydrotest or pneumatic test)
3. Measuring devices (e.g. pressure gauges) – calibrated by reputable third-party
company/in-house accredited by National Accreditation Committee (KAN) or
equivalent
4. Pressure relief valves - calibrated
5. Indicators (as described above) – function test
6. Safety protection features (as described above) – trip test
7. ESD – function test
8. Primary Injection test for breaker
9. Documentation:
a. Manufacturing certificates, maintenance records
b. Testing reports,
c. Manual books
d. Spark arrestor
e. Primary Injection for MCCB
f. Calibration cert for instrumentation/ measuring device
g. IP certificates
h. Lifting point/Frame or Lifting Gears must be accompanied lifting design
calculation; COC
& TER (Thorough Examination Report) by LEEA third party inspector & its
company.
1. Visual inspection
2. Function test and performance test for two (2) hours
3. Package installed with fittings, connectors and regulator – 100% successfully
pressure tested
4. Hose assembly, complete with fittings and connectors – 100% hydrotested
5. Documentation:
a. Manufacturing certificates, maintenance records
b. Testing reports,
c. Manual books
d. Spark arrestor certificate
f. Calibration cert for instrumentation/ measuring device
h. Lifting point/Frame or Lifting Gears must be accompanied lifting design
calculation; COC & TER (Thorough Examination Report) by LEEA third party
inspector & its company

1. Visual inspection
2. Function test and performance test for two (2) hours
3. Air Supply hose assembly, complete with fittings and
connectors – 100% hydrotested
4. Package installed with fittings, connectors and regulator – 100% successfully
pressure tested
5. Documentation:
a. Manufacturing certificates, b. Maintenance records,
c. Testing reports d. Manual books.
e. Calibration cert for instrumentation/ measuring device.
1. Visual inspection
2. Calibration test
3. Function test (bump test) – gas test to be provided by CONTRACTOR
4. Documentation – manual books, manufacturing certificates, calibration
certificates, IP certificates, EX certificates

1. Visual inspection
2. Calibration test
3. Function test (bump test) – gas test to be provided by CONTRACTOR
4. Documentation – manual books, manufacturing certificates, calibration
certificates, IP certificates, EX certificates
1. Function test with refractory materials
2. Hoses, fittings, connectors –
100% successfully hydrotested with complete unit assembled
3. ESD test.
4. Documentation
a. Manufacturing certificates,
b. Maintenance records,
c. Testing reports,
d. Manual books
e. Calibration for instrumentation/ measuring device if required

1. HPU set – function test


2. Hydraulic pump – function test
3. ESD Test
4. Hoses, fittings, connectors – 100% successfully hydrotested with
complete unit assembled
5. Documentation –
a. Manufacturing certificates,
b. Maintenance records,
c. Testing report d. Manual books
e. Calibration for instrumentation/ measuring
f. Atex/Ex Cert for JB if Required.
g. MCCB primary injection if required.

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function and/or performance test report
3. Measuring devices – calibrated by recognized third-party company/in- house
accredited by National Accredited Committee (KAN) or equivalent
4. Certificate of Conformity (CoC)
5. Maintenance logs
6. Testing reports
7. Calibration certificates
8. Manufacturing certificates
1. Visual and dimensional checks (e.g., corrosion free, no structural damage)
2. Function test and performance test
3. Documentation – manufacturing certificates, maintenance records, testing
reports, manual books, calibration certificates and spark arrestor manufacturing
certificates, IP and lifting frames certifications

1. Visual and dimensional checks (e.g., corrosion free, no structural damage)


2. Function test and performance test
3. Documentation – manufacturing certificates, maintenance records, testing
reports, manual books, calibration certificates and spark arrestor manufacturing
certificates, IP and lifting frames certifications
1. Visual and dimensional checks (e.g., corrosion free, no structural damage)
2. Function test and performance test
3. Documentation – manufacturing certificates, maintenance records, testing
reports, manual books, calibration certificates and spark arrestor manufacturing
certificates, IP and lifting frames certifications
Quantity UOM

1 ea

1 ea
1 ea

3 ea
See detail
each type

10 ea

2 ea

1 ea

4 ea
3 ea

10 ea
12 ea

4 ea
4 ea

45 ea
64 ea

41 ea
1 ea

1 ea

1 ea
2 ea

1 ea
1 ea