2/10

Compact System PS900


48 V / 1000 A

Introducing the successor to our successful


600 Series, we have pleasure in presenting a
powerful new compact system, the PS900

The highlights at a glance: We don’t leave you out in the rain. We can give you
individual support through each project phase.
future-proof investment
outstanding price / performance ratio The service portfolio for our power supply systems
covers a wide range including:
compact and space-saving design
universally deployable
planning and projecting
expandable to 5000 A
product and project management
rapid installation
planning the logistic processes
convenient configuration
installation and putting into service
wide range of monitoring and control
routine inspection and troubleshooting service
facilities
operation
high reliability and availability
product training
outstanding service and maintenance
friendliness training on the job
extended AC and temperature range
extra battery connection facilities You too can profit from our
single-battery monitoring many years of experience!
battery test Our sales offices will be pleased to advise you.
3/10

The Compact System


PS900 is …….

a investment safeguard a strong communicator


You already have a system from an earlier series? As the system's "brain" and nerve centre, the
As your power requirement grows, the PS900 SPSC2000 controller communicates not only
can expand your existing systems and thus safe- with all the system's components but also with
guard your investment. the external control centre.

a global player Various communication facilities are available for


this purpose:
The system can be connected to any AC supply - modem
voltage worldwide. - Ethernet/LAN
- floating signals
a powerful space-saver
= cost-saver convenient to configure
The system cabinet conforms to ETS standard Configure the system to suit your needs, conven-
dimensions. One PS900 system cabinet can iently and reliably – directly at the control panel
house up to 10 rectifier modules GR90 100A on the controller or from a PC.
to cover a power requirement of up to 1000 A.
As the power requirement increases, the system of modular design for
can be expanded by paralleling up to 5 cabinets
to provide 5000 A.
flexible expansion
Up to 10 rectifiers and up to 10 load feeders
installed in a jiffy rated 250A / 80V can be quickly and easily fitted
or exchanged without interrupting operation.
The rectifiers are 19" plug-in modules of hot-plug
design. Installation couldn't be easier:
plug in – switch on – finished.

your guarantee for


uninterruptible power
System PS900 operates in the continuous float
mode. Up to 4 battery groups can be connected.
If the public AC supply fails, the batteries con-
tinue supplying the loads with DC power with no
break in operation.
4/10

Large
Medium
Small

Mini System PS900


6.1 kW – 305 kW

PS900
A PS900 supplies current from
PS900 100A up to a maximum of
1000A and can be connected to
Technical Data any AC power network world-
wide.
The system operates in the con-
tinuous float mode. If the AC
source fails, the batteries con-
tinue the supply to the loads
without interruption.

To protect the battery against


deep discharge and to discon-
nect the supply in an emergency,
the individual PS900 cabinet can
be optionally equipped with a
battery shutdown facility rated
Input 1200 A.
Input voltage range 3/N/PE AC 400 V (-27% ... +20%)
For the safety of operating per-
3/PE AC 230 V (-27% ... +20%)
sonnel, all live parts in the cabi-
1/PE AC 230 V (-27% ... +20%)
net are covered to meet the re-
Frequency range 47.5 Hz … 63.0 Hz quirements of IEC-60950. All
load and battery fuses are in-
Output
serted in touch-safe, heavy-duty
Nominal voltage 42.0 V ... 61.0 V disconnectors.
Output voltage per cabinet 6.1 kW … 61 kW
The GR90 100A rectifier modules
Loads: and the SPCS2000 controller
fuse switch disconnector type NH00 max. 10 x 250 A / 80 V DC communicate with each other
configuration on delivery 2 x 250 A / 80 V DC over the CAN bus.
Batteries:
fuse switch disconnector type NH00 max. 4 x 600 A AC Input
configuration on delivery 2 x 600 A
AC power distributors are avail-
General Data able in two variants: as a wall-
mounted distributor and as a
Temperature range 0…+50º C
cabinet distributor, the former
Noise level (normal operation) < 50 dBA with 5, the latter with 10 three-
Protective class I as per VDE 0106, Part 1 (IEC 536) phase circuits for connecting
and VBG 4 power supply cabinets.
The power distributors can be
Ingress protection IP 20 as per EN 60529 (IEC 529), optionally equipped with light-
IP00 in cable entry region ning and surge protection de-
Electromagn. compatibility (EMC) vices (SPD Type 1, Type 2).
emission EN 61000-6-3
immunity EN 61000-6-2
Electrical safety EN 60 950
5/10

PS900

Design
The basic frame of the PS900 is a strong but light-
weight steel construction with overall dimensions
according to the ETS 2200 mm height standard.
The system is particularly suitable for deployment in
confined spaces, e.g. in containers, for powering digi-
tal exchange equipment, mobile radio and similar
2200
applications.
mm

The cabinets are of modular and service-friendly de-


sign. One cabinet accommodates up to 10 rectifiers
GR90 100 A as 19" plug-in modules terminating at the
back of the cabinet via hot-plug connectors.
The cabinets are closed at the rear so that they can be
freely positioned in the room.
At the front the cabinets have no visible cabling, and
provide covers for batteries and loads so there is no
need for a door.
If required, they can be furnished with a lockable
door.

Mounted readily accessible at eye level is the central


controller SPSC2000.
The top section of the cabinet provides the space for
up to 10 load feeders type NH00.
600
The battery connecting unit can accommodate up to 4 600
mm
battery disconnectors each rated 600A. mm

Up to 5 cabinets PS900 can be connected in parallel


and can thus provide a total current of up to 5000 A.
Picture: This system is equipped with 10 rectifier modules
GR90 100A, the controller SPSC2000, 5 load fuses and four
battery fuses.
For clarity, the covers in the top and bottom sections of the
cabinet have been removed.

System Overview dimensions Weight Variant Ordering Number


H x W x D in mm
System cabinet PS900 without 2200 x 600 x 600 187 kg with 2 battery fuses S30050-G6361-X100
rectifiers mains 3/N/PE AC 400 V
with 2 battery fuses , S30050-G6361-X200
mains 3/PE AC 230 V
equipped ex work with
Controller SPSC2000 with 4 battery fuses and S30050-G6361-X300
and 2 load fuses shunts
mains 3/N/PE AC 400 V
Front door on request
GR90 100A 133 X 439 x 410 18 kg S31043-K1390-X
Controller SPSC2000 40 x 220 x 300 2.3 kg S30050-K6351-X101
NV900 300A 1000 x 800 x 300 87 kg S30050-G6032-X100
NV900 630A 2200 x 600 x 600 150 kg S30050-G6033-X100
6/10

Latest Technology Hot-Plug-in Design =


Combining switch-mode technology with the latest Easy Handling and Maintenance
components enables the rectifiers to achieve a The hot-plug-in connectivity makes the rectifier
high power density. As a result the rectifier is com- modules very easy to install / replace, allowing
pact and light while meeting the most exacting service-friendly handling without disrupting opera-
demands as to efficiency and electromagnetic tion.
compatibility (EMC). Once the module has been plugged and latched
Provision is made to ensure a sinusoidal AC input into the position provided, it is automatically ter-
current is drawn. minated and immediately ready for operation.
The DC output of the rectifiers is short-circuit- Each power module has its own built-in fan. The
proof. With high switching frequencies and opti- fan speed adapts automatically to the temperature
mized control loops the modules can respond fast and power. The fans are very easy to maintain as
to dynamic load changes while maintaining high- they are accessible from the front – all that is re-
est output voltage stability. quired is to remove the rectifier cover.
Active Power Factor Correction (PFC) eliminates
reaction on the AC source almost completely.
The reliable electrical isolation between the AC at Universally Deployable
the input and the DC at the output enables the The rectifier can operate from a wide range of AC
rectifier module to be used for powering TNV cir- voltages and is thus suitable for AC networks
cuits (telecommunication network voltage). worldwide.

Internal Redundancy =
Enhanced Reliability
Supply reliability has been further enhanced by
configuring the rectifier from three identical, inde-
pendently operating power modules.

GR90 100 A
19" Plug-in Module
7/10

GR90 100A
S31043-K1390-X

Input Latest Technology


Nominal voltage 3/N/PE AC 400 V (-27% ... +20%) Active current equalisation en-
3/PE AC 230 V (-27% ... +20%) sures that all the rectifiers in a
1/PE AC 230 V (-27% ... +20%) system (up to 50 units!) are uni-
formly loaded during operation.
Operating voltage range 167 V … 276 V
Extended operating voltage range Central Control
with power derating 90 V… 167 V
The rectifiers GR90 100A pro-
Frequency range 47.5 Hz … 63.0 Hz duce an output of 48 V DC and
Power factor > 0.99 are ready for immediate opera-
tion on the factory default set-
Output ting even without central con-
Nominal voltage 48.0 V trol. Normally, however, the rec-
Output power max. 6100 W tifier modules are employed in
conjunction with controller
Output current max. 100 A SPSC2000 to monitor and control
Setting range for output current 10…100 % (10…100 A) rectifier operation.
Rectifiers and controller commu-
≤ 1.8mV frequency weighted
nicate via a CAN-bus (Control
Psophometric noise (ITU-T A-filter)
Area Network).
Efficiency 0.91 Settings on the rectifier module
General Data are entered centrally from the
controller via the CAN-bus. The
Temperature range, operating -5°C…+70°C CAN-bus can also be used to up-
> +55°C with power derating date the firmware on the recti-
Noise level (normal operation) < 50 dBA fier.
I as per VDE 0106, Part 1 (IEC 536) and
Protective class VBG 4 Remote Monitoring
Ingress protection IP 20 as per EN 60529 If required, the rectifier can also
be monitored via the controller
Electrom. compatibility (EMC)
SPSC2000 from a remote control
emission EN 61000-6-3 / 3-2 / -3-3 centre.
immunity EN 61000-6-2
Dimensions (H x W x D) in mm 133 x 439 x 410
Weight 18 kg

Easy access to fans: The cover to


the rectifier modules is removable.
8/10

SPSC2000
Central Controller

As the central control and monitoring unit, the


SPSC2000 (Siemens Power Supply Controller) repre-
sents the "brain" of the power supply system and
provides the interface between man and system.

Local Remote

System configured Remote monitoring


and firmware updated Monitoring
Contact to control
conveniently per lap- the loads
centre optionally via
top via USB or RS232 modem, ETHERNETetc.

Via CAN bus: Monitoring the


Monitoring, peripheral devices.
Addressing, protecting and e.g. air-conditioning,
monitoring and testing of Diesel generator,
controlling of up to 50 batteries fire alarms, door contacts,
rectifiers GR90 100A
SPDs (surge protection
devices)
9/10

SPSC2000
Versatile and User-Friendly

The controller SPSC2000 The controller saves system


communicates with the recti- status information. The stored
fiers via a CAN bus data provide the basis for specific
monitors and controls up to statistics to enable retrospective
50 rectifiers on a standard analysis, but more importantly to
basis or individually facilitate forward planning and
early detection of possible risks.
monitors system voltage and
load sharing
Alarms and other status informa-
determines the power deliv- tion can be sent via different
ered to the load (average and paths operating at different
peak power, total energy) speeds to their destination –
monitors loads, batteries and whether it be a locally connected
peripheral units PC or a remote control centre –
determines the charging to suit the specific requirement.
voltage of the battery (also
on temperature-dependent The "Power Inspector" software
basis) enables personnel at a distant
saves data for statistical control centre to form a picture
analysis of the PS system's present status
and to initiate any action that
can be configured locally
may be necessary.
with and without service PC
can be optionally linked via These facilities turn the system
modem, ETHERNET/LAN etc. into an active communications
to a control centre. partner particularly for the ser-
vice staff, enabling them to re-
spond rapidly and efficiently to
operational requirements.

Put in a nutshell: By exploiting


the controller's capabilities, you
can

be confident that the system


will provide the maximum de-
gree of reliability
reduce operating costs,
make a rapid, targeted re-
sponse to any fault
plan efficiently on the basis of
specific analyses.

Last but not least –


our Service staff is always
there at your disposal.
How to contact us
Siemens AG
ICN– Power Supply Systems
Rudolf - Vogel - Bogen 5
D-81739 München

Mail address: D-81730 München

Tel.: (089) 722 – 2 58 38


Fax.: (089) 722 – 2 39 56
E-mail: powersupply@siemens.com
Intranet: http://intranet.icn.siemens.de/powersupply

Consolidate your success


with a
vigorous partnership

Siemens will dedicate its energy to


each stage of your project − from de-
velopment, project design, installa-
tion to service.

You benefit from our extensive ex-


perience in the fields of communica-
tions and power supply and from the
professionalism of a corporation that
spans the globe.

It takes the driving force of a stable


power supply to make sure your
communication networks keep really
humming.
© Siemens AG 2005 • COM •
All the time. Rudolf-Vogel-Bogen 5, D-81739 München

Order No: A30050-X6361-X-1k-76K6

The information provided in this brochure contains merely


general descriptions or characteristics of performance which
in case of actual use do not always apply as described or
which may change as a result of further development of the
products. An obligation to provide the respective characteris-
tics shall only exist if expressly agreed in the terms of con-
tract. Availability and technical specifications are subject to
change without notice.

You might also like