Professional Documents
Culture Documents
Focused on outcomes
In the ever-changing world of healthcare, you face more challenging patients and more pressure
to deliver outcomes. The AVEA ® ventilator was designed with you in mind. Its comprehensive
array of clinical tools and advanced monitoring allow you to guide your patient through the
continuum of care simply and efficiently with a focus on improving outcomes.
Advancing patient care
The AVEA ventilator automates many of the routine tasks you
face every day, allowing you to focus on what’s most important—
your patient.
• Leak compensation
• Volumetric capnography—equipped with this option, the AVEA ventilator adds another key piece of information to provide improved monitoring of patient
condition. When tied with exclusive BiCore technology, this powerful tool provides the most comprehensive monitoring array of any ventilator available.
• Precision gas delivery system—supplies accurate tidal volumes from 2 mL to 2.5 L and was the first of its kind to automatically compensate for heliox gas delivery.
• On-board compressor—The optional on-board air compressor can meet your patient’s needs whether in the ICU or moving to CT scan. This powerful scroll
compressor can only be found on the AVEA ventilator and is capable of operating the ventilator for up to two hours on battery.*
• Communication—three different serial protocols can be selected from the utility screen to simplify integration with hospital information systems or remote
alarm monitoring.
• Advanced CO2 measurements • One of four automated assessment maneuvers • Measure the actual work imposed by the
endotracheal tube
• Traditional time-based capnography • Low-inflection point calculation
• Tracheal pressure monitoring
• Alveolar, anatomic and physiologic dead spaces • High-inflection point calculation
• Esophageal pressure monitoring
• Vd/Vt ratio, alveolar minute ventilation • Storage of four measurements for comparison
(superimposable) • Transpulmonary pressure monitoring
*
When equipped with optional external battery.
Reference
1 Gluck, E. H. et al. Medical effectiveness of esophageal balloon pressure measurement in weaning patients from mechanical ventilation. Cri Care Med, 1995.
2 Talmor, D., Ritz, R. et al. Mechanical ventilation guided by esophageal pressure in acute lung injury. NEJM, 2008.
WARNING: U.S. Federal Law restricts this device to sale by or on the order of a physician.
CareFusion
22745 Savi Ranch Parkway
Yorba Linda, CA 92887
800.231.2466 toll-free
714.283.2228 tel
714.283.8493 fax
© 2012 CareFusion Corporation or one of its subsidiaries. All rights reserved. AVEA and BiCore are trademarks or
registered trademarks of CareFusion Corporation or one of its subsidiaries. RC0105-01 L3140 Rev. D (0212/4000)
CareFusion
Yorba Linda, CA
carefusion.com