7 Fom Plug-In Card FOR O9500R User'S Manual
7 Fom Plug-In Card FOR O9500R User'S Manual
FOR O9500R
USER'S MANUAL
LIST OF TABLES
Table 2-1 LED Indication.....................................................................................................................................6
LIST OF FIGURES
Figure 2-1 7FOM Panel View .............................................................................................................................3
Figure 2-2 SFP module and Optical Cable....................................................................................................4
Figure 2-4 FOM port with SFP module ..........................................................................................................4
Figure 2-5 FOM port with SPF module and optical cable ...........................................................................5
Figure 3-1 Menu Tree .......................................................................................................................................7
Figure 5-1 7 FOM Loopback Diagram..........................................................................................................35
D Bitte führen Sie das Gerät am Ende seiner Lewbensdauer den zue Verfügung stehended
Rückgabeund Sammelsystemen zu.
GB At the end of the product's useful life, please dispose of it at appropriate collection points
provided in your country
F Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage approprié.
ES Para preservar el medio ambiente, al final dela vida útil de su producto, depositelo en los
laguares destinado aello de acuerdo con la legislación vigente.
P No final de vida útil do producto, por favor coloque no ponto de recolha apropriado.
I I Onde tutelare l'ambiente, non buttate l'apparecchio trai i normali rifiuti al termine della sua
vita utile, ma portatelo presso i punti DI RACCOLTA specifici per questi rifiuti previsti dalla
normativa vigente.
NL Wij raden u aan het apparant aan het einde van zijn nuttige levensduur, niet bij hey gewone
huisafval te deponeren, maar op de dearvoor bestemde adressen.
DK Når produktet er udtjent, bor det børtskaffes via de sæ rlige indsamlingssteder i landet.
N Ved slutten av produktets levetid bør det avhendes på en kommunal miljøstasjon eller
leveres til en elektroforhandler.
S Lämna vänligen in produkten på lämplig återvinningsstation när den är förbrukad.
FIN Hävitä tuote käytöiän päättyessä viemällä se asianmukaiseen keräyspisteeseen.
PL Gdy produkt nie nadaje sie juz do dalszego uzytku, nalezy zostawic go w jednym ze
specjalnych punktów zajmujacych sie zbiórka zuzytych producktów w wybranych
miejscach na terenie kraju.
CZ Po skončení jeho životnosti odložte prosím výrobek na přislušném sbĕrném místé
zřízeném dle předpisů ve vaší zemi.
SK Po skončení jeho životnosti odovzdajte prosím zariadenie na príslušnom zbernom mieste
podía platných miestnych predpisov a noriem.
SLO Ko se izdelku izteče življenska doba, ga odnesite na ustrezno zbirno mesto oziroma ga
odvrzite v skladu z veljavnimi predpisi.
GR Στο Тέλος тης λειτουργικής Ζωής του προϊόντος παρακαλώ
1 Product Description
The Loop-O9500R 7 FOM card is a high-speed module that can connect with the AM3440 series and
O9310-E1 using Loop proprietary FOM (Fiber Optical Modulator) interface. Each card has 7 FOM
interfaces. Each FOM interface supports up to 4 E1 aggregate channels. The 7 FOM card is E1 mode
configurable and supports Tributary Line 1+1 Protection. When protection enabled with 1+1, the
O9500R can support up to 14 ports of FOM.
1.1. Application
1
Chapter 1 Product Description
1.2. Specification
Optical Fiber Interface Characteristics (please refer to SFP optical module brochure for detail)
Diagnostics Test
Optical Fiber Local and remote loopbacks
E1 Link Local and remote loopback, send test pattern
2
Chapter 2 Installation
2 Installation
The following list indicates a site selection guideline. Users need to follow this guideline to select a
proper installation site.
z Location of the Rack should be part of the central office equipment layout design. Considerations
should be given to entrance cable routing and -48 Vdc power.
z The installation site should have -48 Vdc power. An optional AC/DC power converter can be
used. Use only with Class 2 power source, -48 Vdc, 100 watts.
3
Chapter 2 Installation
All electrical connections are on the backplane. The electrical connections are made when the card is
firmly seated into a tributary slot in the Loop-O9500 chassis. 7 FOM cards are hot swappable.
4
Chapter 2 Installation
Then, plug the optical cable into the SFP module. The LED light will turn from red to green. The optical
installation is now complete.
Figure 2-4 FOM port with SPF module and optical cable
5
Chapter 2 Installation
The following table lists the 7-FOM port LED function, color, and indications.
6
Chapter 3 Terminal Operation
3 Terminal Operation
3.1 Menu Tree
7
Chapter 3 Terminal Operation
You must register your 7FOM cards with the O9500R device.
[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration
[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default
Press N> Unit Registration from the Controller Menu. The Unit Registration screen will appear.
Select the command “Card Registration” and press the Enter key.
8
Chapter 3 Terminal Operation
Use the Tab key to scroll in the Tributary slot that your 7 FOM card is plugged into. Press the Enter
key.
Command : Card Registration
Unit : Trib-1
The model of card will appear. Move the cursor to the Registered Model field and select the protection
type. “NP”= Not Protected. “PRTD”=Protected.
In the sample screen below, we choose 7FOM-PRTD:
Press the Enter key. A registration prompt will appear as the registration takes place.
Registration......SUCCESS!
9
Chapter 3 Terminal Operation
If you have other cards to register do it now. Each plug-in interface card must be registered separately.
Card De-registration:
To de-register a card, please activate the command “Card Un-registration”. The setup procedure is
similar to that of “Card registration”.
10
Chapter 3 Terminal Operation
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
I -> SFP Information L -> File Transfer
Q -> Currently-Active Alarm Summary N -> SNCP/UPSR APS Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance G -> Loopback & Diagnostics Setup
D -> FOM ALS/APSD Display H -> FOM ALS/APSD Setup
K -> Diagnostics Display
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
11
Chapter 4 System Display
4 System Display
¾ Command Path: Unit Menu> (C) Config Display > (A) Trace Message & EPSL Display
¾ Function:
Key in the FOM port and E1 channel number, and press Enter.
Unit 1 7FOM === Trace Message & EPSL Display === 15:01:06 06/18/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~4, BACKSPACE to edit
FOM Port : 1
E1 Channel: 1
The current status of the trace message and EPSL will show on the screen:
Unit 1 7FOM === Trace Message & EPSL Display === 15:01:06 06/18/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~4, BACKSPACE to edit
FOM Port : 1
E1 Channel: 1
<< ESC key to return to previous menu, SPACE bar to refresh >>
12
Chapter 4 System Display
¾ Command Path: Unit Menu> (C) Config Display > (B) Customer Information Display
¾ Function:
The screen shows the name and contact information of the customer for each port.
Unit 1 7FOM === Customer Information Display === 15:13:51 06/18/2010
<< ESC key to return to previous menu, SPACE bar to refresh >>
¾ Command Path: Unit Menu> (C) Config Display > (C) TPSG Protection Mode Display
¾ Function: The screen shows the current TPSG protection type and mode.
Unit 1 7FOM === TPSG Protection Mode Display === 15:33:13 06/18/2010
<< ESC key to return to previous menu, SPACE bar to refresh >>
13
Chapter 4 System Display
¾ Command Path: Unit Menu> (C) Config Display > (D) TPSG Protection Switch Display
¾ Function: The screen shows the working line side (left, right) for each of the FOM port.
Unit 1 7FOM === TPSG Protection Switch Display === 15:40:34 06/18/2010
<< ESC key to return to previous menu, SPACE bar to refresh >>
PORT#6
14
Chapter 4 System Display
FOM Port: 1
FOM Port: 1
<< ESC key to return to previous menu, SPACE bar to refresh >>
15
Chapter 4 System Display
16
Chapter 4 System Display
¾ Command Path: Unit Menu> (A) Current Alarm Status > (A) SDH/SONET Alarm Status
¾ Function: Display the SDH/SONET alarm for Each FOM port and E1 channel.
First, Key in the FOM port and E1 channel number. Then, press Enter:
Unit 1 7FOM === SDH/SONET Alarm Status === 16:34:32 06/18/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit
FOM Port : 1
E1 Channel: 1
Type Status
-------- --------
TU-LOP Clear
TU-AIS Active
LP-UNEQ ABS
LP-PLM Clear
LP-TIM Clear
LP-RDI-P Clear
LP-RDI-S Clear
LP-RDI-C Clear
LP-REI ABS
LP-BIP ABS
<< ESC key to return to previous menu, SPACE bar to refresh >>
17
Chapter 4 System Display
¾ Command Path: Unit Menu> (A) Current Alarm Status > (B) E1 Alarm Status
¾ Function: Display the E1 alarm for Each FOM port and E1 channel.
First, Key in the FOM port and E1 channel number. Then, press Enter. The E1 alarm status will show
on the screen.
Unit 1 7FOM === E1 Alarm Status === 18:50:49 08/12/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit
FOM Port : 1
E1 Channel: 1
Type Status
-------- --------
AIS Active
<< ESC key to return to previous menu, SPACE bar to refresh >>
¾ Command Path: Unit Menu> (A) Current Alarm Status > (C) FOM Alarm Status
¾ Function: Display the FOM alarm for Each FOM port.
First, Key in the FOM port number. Then, press Enter. The FOM alarm status will show on the screen.
Unit 1 7FOM === FOM Alarm Status === 16:41:16 06/18/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit
FOM Port: 1
Type Status
-------- --------
LOS Active
LOF ABS
RAI Clear
UAS ABS
<< ESC key to return to previous menu, SPACE bar to refresh >>
18
Chapter 4 System Display
¾ Command Path: Unit Menu> (A) Current Alarm Status > (D) FOM Status
¾ Function: Display the FOM alarm for Each FOM port.
First, Key in the FOM port number. Then, press Enter. The status of the local and remote FOM
interface will show on the screen. The remote interface can be a FOM card on O9500R, a FOM card
on AM3440, O9310 FOM with CPU, and O9310 FOM without CPU. Sample screens are shown as
below.
With Remote O9500 FOM card:
Unit 1 7FOM === FOM Status === 10:47:15 07/29/2010
FOM Port: 3
==== Local FOM Interface Status ==== ==== Remote FOM Interface Status ====
Interface Type: 7FOM Interface Type: 7FOM
LOF : NO LOF : NO
Framing error : 0 Framing error : 0
Checksum error: 0 Checksum error: 0
<< ESC key to return to previous menu, SPACE bar to refresh >>
FOM Port: 1
==== Local FOM Interface Status ==== ==== Remote FOM Interface Status ====
Interface Type: 7FOM Interface Type: MUX FOM
LOF : NO LOF : NO
Framing error : 0 Framing error : 0
Checksum error: 0 Checksum error: 0
<< ESC key to return to previous menu, SPACE bar to refresh >>
19
Chapter 4 System Display
FOM Port: 1
==== Local FOM Interface Status ==== ==== Remote FOM Interface Status ====
Interface Type: 7FOM Interface Type: CPE FOM without CPU
LOF : NO LOF : NO
Framing error : 18 Framing error : 0
Checksum error: 0 Checksum error: 0
<< ESC key to return to previous menu, SPACE bar to refresh >>
FOM Port: 1
==== Local FOM Interface Status ==== ==== Remote FOM Interface Status ====
Interface Type: 7FOM Interface Type: CPE FOM with CPU
LOF : NO LOF : NO
Framing error : 0 Framing error : 0
Checksum error: 0 Checksum error: 0
<< ESC key to return to previous menu, SPACE bar to refresh >>
20
Chapter 4 System Display
In the Unit Performance section, you can view the 7FOM card performance under two categories:
SDH/SONET performance and FOM performance. Each category contains 15-Min/01-Hour,
15-Min/24-Hour, and 01-Day/07-Day performance report.
¾ SDH/SONET Performance Report:
Below is the sample display procedure of SDH/SONET performance:
1. Select the performance type you need. Here, we select (1) 15-Min/01-Hour Performance Report.
2. Key in the FOM port number and the E1 channel for display:
Unit 1 7FOM === 15-Min/01-Hour Performance Report === 18:15:02 06/18/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit
FOM Port : 1
E1 Channel: 1
4. For 15-Min/24-Hour Performance Report, you’ll also have to select the parameter type: UAS, BES,
SES, EB, BBE, ES
Parameter : UAS
5. The performance report for the current, 1st, 2nd, 3rd and 4th nearest time interval of each parameter
will show on the screen as below:
Unit 1 7FOM === 15-Min/01-Hour Performance Report === 18:16:37 06/18/2010
21
Chapter 4 System Display
FOM Port: 1
4. For 15-Min/24-Hour Performance Report, you’ll also have to select the parameter type: UAS, BES,
SES, CV, ES
Parameter : UAS
5. The performance report for the current, 1st, 2nd, 3rd and 4th nearest time interval of each parameter
will show on the screen as below:
Unit 1 7FOM === 15-Min/01-Hour Performance Report === 18:28:42 06/18/2010
LINE PORT#1
-- Valid Seconds in Current 15-Min Interval : 828 seconds
<< ESC key to return to previous menu, SPACE bar to refresh >>
22
Chapter 4 System Display
¾ Command Path: Unit Menu> (K) Diagnostics Display > (A) FOM Loopback Display
¾ Function: Display local and remote loopback status for Each FOM port.
Unit 1 7FOM === FOM Loopback Display === 18:43:50 06/18/2010
<< ESC key to return to previous menu, SPACE bar to refresh >>
23
Chapter 4 System Display
¾ Command Path: Unit Menu> (K) Diagnostics Display > (B) E1 Diagnostics Display
¾ Function: Display the E1 Diagnostics report for each channel
Unit 1 7FOM === E1 Diagnostics Display === 18:59:12 08/12/2010
Port- Loopback Port- Loopback
Chan Local/Remote Test Pattern Chan Local/Remote Test Pattern
---- ------------- ------------------- ---- ------------- -------------------
1-1 OFF/OFF <No Test Pattern> 5-1 OFF/OFF <No Test Pattern>
1-2 OFF/OFF <No Test Pattern> 5-2 To FOM/OFF <No Test Pattern>
1-3 OFF/OFF <No Test Pattern> 5-3 OFF/OFF <No Test Pattern>
1-4 OFF/OFF <No Test Pattern> 5-4 OFF/OFF <No Test Pattern>
24
Chapter 5 System Setup
5 System Setup
¾ Command Path: Unit Menu > (S) Config Setup > (A) Trace Message & EPSL Setup
¾ Configuration:
¾ How to Set up
Key-in the FOM port and E1 channel number. Press Enter. Then, set up the trace message and TX PSL
and EPSL configuration you need.
Unit 1 7FOM === Trace Message & EPSL Setup === 15:22:47 06/21/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port : 1
E1 Channel: 1
25
Chapter 5 System Setup
¾ Command Path: Unit Menu > (S) Config Setup > (B) Customer Information Setup
¾ How to Set up:
Key-in the customer information for each port, then, press Enter to save the configuration.
Unit 1 7FOM === Customer Information Setup === 16:11:18 06/21/2010
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort
¾ Command Path: Unit Menu > (S) Config Setup > (C) TPSG Protection Mode Setup
¾ Configuration:
Field Setting Option Default
TPSG Protection Type Line 1+1 Line 1+1
TPSG Protection Mode Revertive, Non-revertive Non-revertive
26
Chapter 5 System Setup
¾ Command Path: Unit Menu > (S) Config Setup > (D) TPSG Protection Switch Setup
¾ Configuration:
Field Setting Option Default
FOM port #1~7 Left, right Left
¾ How to Set up:
Select the working line side for each port. Then, press Enter to save the configuration.
Unit 1 7FOM === TPSG Protection Switch Setup === 17:24:49 06/21/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
27
Chapter 5 System Setup
¾ Command Path:
Unit Menu > (M) Unit Alarm Setup > (A) SDH/SONET Alarm Mask and Relay Setup
¾ How to Set up:
Select the working line side for each port. Then, press Enter to save the configuration.
Unit 1 7FOM === SDH/SONET Alarm Mask & Relay Setup ==10:19:09 06/22/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port : 1
E1 Channel: 1
Unit 1 7FOM === SDH/SONET Alarm Mask & Relay Setup ==10:19:09 06/22/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port : 1
E1 Channel: 1
28
Chapter 5 System Setup
¾ Command Path:
Unit Menu > (M) Unit Alarm Setup > (B) E1 Alarm Mask and Relay Setup
¾ How to Set up:
Select the FOM port and E1 channel number. Then, press ENTER.
Unit 1 7FOM === E1 Alarm Mask & Relay Setup === 11:23:27 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port : 1
E1 Channel: 1
Select Enable or Disable for the AIS alarm and alarm relay. Then, press ENTER to confirm with the
setting.
Unit 1 7FOM === E1 Alarm Mask & Relay Setup === 11:23:27 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port : 1
E1 Channel: 1
¾ Command Path:
Unit Menu > (M) Unit Alarm Setup > (C) FOM Alarm Mask and Relay Setup
¾ How to Set up:
Select the FOM port number. Then, press ENTER.
Unit 1 7FOM === FOM Alarm Mask & Relay Setup === 14:48:53 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port: 1
Select Enable or Disable for the LOS, LOF, RAI and UAS alarm and alarm relay. Then, press ENTER
to confirm with the setting.
Unit 1 7FOM === FOM Alarm Mask & Relay Setup === 14:48:53 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port: 1
29
Chapter 5 System Setup
¾ Command Path:
Unit Menu > (M) Unit Alarm Setup > (C) Alarm Severity Setup
¾ How to Set up:
Select the severity level “major, minor, inform, critical” for each alarm. Then, press ENTER to
confirm with the setting.
Unit 1 7FOM === Alarm Severity Setup === 15:24:46 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
¾ Command Path:
Unit Menu > (M) Unit Alarm Setup > (D) Insert AIS Alarm Setup
¾ How to Set up:
You can insert LO-UNEQ, LP-TIM or LP-PLM to AIS alarm. Select “Enable” or “Disable” for each
option, then, press ENTER to confirm with the setting.
Unit 1 7FOM === Insert AIS Alarm Setup === 15:50:24 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Type Alarm
-------------- --------
LP-UNEQ to AIS ENABLE
LP-TIM to AIS ENABLE
LP-PLM to AIS ENABLE
30
Chapter 5 System Setup
¾ Command Path:
Unit Menu > (L) File Transfer > (A) Unit Download Firmware
¾ How to Set up:
Key in the TFTP server IP and firmware file name. Press ENTER to download the firmware.
Unit 1 7FOM === Unit Download Firmware === 16:29:00 06/23/2010
ARROW KEYS: CURSOR MOVE, Please Input: nnn.nnn.nnn.nnn, BACKSPACE to edit
<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>
¾ Command Path:
Unit Menu > (L) File Transfer > (B) Copy Firmware to Standby Unit
¾ How to Set up:
On the screen, a prompt will ask if you are sure to copy firmware to standby unit. Press “Y” to confirm.
Copy firmware to standby unit - are you sure ?
31
Chapter 5 System Setup
¾ Command Path:
Unit Menu > (N) SNCP/UPSR APS Setup
The SNCP/UPSR APS Setup screen will appear. Press A or B.
Unit 2 7FOM === SNCP/UPSR APS Setup === 18:01:44 09/02/2011
<< Press ESC key to return to Main Menu or enter a command >>
Command Path: Unit Menu > (N) SNCP/UPSR APS Setup > (A) SNCP/UPSR APS Command
¾ How to Set up:
Select the FOM port, E1 channel number, and Command. Then, press ENTER to save the new
setting.
Unit 2 7FOM === SNCP/UPSR APS Command === 18:01:53 09/02/2011
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port : 1
Channel : 01
Command : Clear
Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary
E1 Channel 1 to 4
Command CLEAR,
32
CHAPTER 5 System Setup
Command Path: Unit Menu > (N) SNCP/UPSR APS Setup > (B) SNCP/UPSR Revertive Setup
¾ How to Set up:
Select the FOM port, E1 channel number, and Command. Then, press ENTER to save the new
setting.
Unit 2 7FOM === SNCP/UPSR Revertive Setup === 18:02:09 09/02/2011
ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit
Select path ==>
Port : 1_
Channel : 1
E1 Channel 1 to 4
33
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (R) Performance Setup/Clear > (A) Clear Performance Data
¾ How to Set up:
Press “A” from the Performance Setup/Clear menu. A prompt will appear as below.
You can choose to clear performance of all ports, or individual port (port1~port7).
After selection, press ENTER to confirm with your setting.
>> Use TAB key to select port, and ENTER key to clear performance: All Ports
¾ Command Path:
Unit Menu > (R) Performance Setup/Clear > (B) Performance Threshold Setup
¾ Configuration:
Field Setting Options Default
TCA Alarm Enable, Disable Disable
Severity Inform, Major, Minor, Critical Inform
¾ How to Set up:
Disable or enable each monitor point, and select the severity level you need. Then, press ENTER to
save the configuration.
Unit 1 7FOM === Performance Threshold Setup === 17:10:25 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
34
CHAPTER 5 System Setup
The O9500R 7 FOM card is able to connect to remote devices such as O9500R, AM3440 or O9310
with a remote 7FOM card. The system supports FOM loopback and E1 loopback for self-testing.
FOM Loopback:
The outgoing optical signal is looped back through the optical line. All its channels are looped back to
the receiver path. This loopback test is activated by the test command.
E1 Loopback:
The incoming E1 signal is loopback to the outgoing E1 signal, or vise versa. This loopback is used to
isolate the local equipment from a troubled E1 signal. E1 loopback test can be activated from the
terminal.
35
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (G) Loopback & Diagnostics Setup > (A) FOM Loopback Setup
¾ Configuration:
Field Setting Options Default
Port-1 ~ Port-7 OFF, LOC, LLB OFF
¾ How to Set up:
Select the loopback type (LOC= local loopback, LLB= line loopback) for each port. Then, press
ENTER to save the configuration.
Unit 2 7FOM === FOM Loopback Setup === 15:44:29 06/29/2010
ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT
36
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (G) Loopback & Diagnostics Setup > (B) FOM Remote Loopback Setup
¾ Configuration:
Field Setting Options Default
Port-1 ~ Port-7 OFF, LLB OFF
¾ How to Set up:
Select the loopback type (LOC= local loopback, LLB= line loopback) for each port on the remote FOM
card. Then, press ENTER to save the configuration.
Unit 2 7FOM === FOM Remote Loopback Setup === 16:07:37 06/29/2010
ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT
37
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (G) Loopback & Diagnostics Setup > (C) E1 Loopback Setup
¾ Configuration:
Field Setting Options Default
Port-1 ~ Port-7: Channel 1~4 OFF, TO BP, TO FOM OFF
¾ How to Set up:
Select the loopback direction for E1 channel 1~4 of each port. Then, press ENTER to save the
configuration.
Unit 2 7FOM === E1 Loopback Setup === 10:42:40 07/29/2010
ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT
PORT-1 PORT-5
CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM
CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM
PORT-2 PORT-6
CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM
CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM
PORT-3 PORT-7
CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM
CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM
PORT-4
CHANNEL-1: *OFF To BP To FOM (To BP = To Backplane)
CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM
38
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (G) Loopback & Diagnostics Setup > (D) E1 remote Loopback Setup
¾ Configuration:
Field Setting Options Default
Port-1 ~ Port-7: Channel 1~4 OFF, To BP, To FOM OFF
¾ How to Set up:
Select the loopback direction for E1 channel 1~4 of each port at the remote site. Then, press ENTER
to save the configuration.
Unit 2 7FOM === E1 Remote Loopback Setup === 10:43:28 07/29/2010
ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT
PORT-1 PORT-5
CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM
CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM
PORT-2 PORT-6
CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM
CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM
PORT-3 PORT-7
CHANNEL-1: *OFF To BP To FOM CHANNEL-1: *OFF To BP To FOM
CHANNEL-2: *OFF To BP To FOM CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM CHANNEL-4: *OFF To BP To FOM
PORT-4
CHANNEL-1: *OFF To BP To FOM (To BP = To Backplane)
CHANNEL-2: *OFF To BP To FOM
CHANNEL-3: *OFF To BP To FOM
CHANNEL-4: *OFF To BP To FOM
39
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (G) Loopback & Diagnostics Setup > (E) E1 Diagnostics Setup
¾ Configuration:
Field Setting Options Default
FOM Port 1~7 1
E1 Channel 1~4 1
Direction FOM side, System Side FOM side
15-1 ^20-1
Test Pattern 2^ ,2 , OFF OFF
¾ How to Set up:
First, select the target FOM port and E1 channel number. Then, press ENTER.
Unit 2 7FOM === E1 Diagnostics Setup === 16:15:44 06/29/2010
ARROW KEYS: CURSOR MOVE, Please Input: 1~7, BACKSPACE to edit
FOM Port : 1
E1 Channel : 1
Choose the direction and enable the test pattern. Then, press ENTER to save the configuration.
Unit 2 7FOM === E1 Diagnostics Setup === 16:15:44 06/29/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
FOM Port : 1
E1 Channel : 1
Direction : FOM side
Test Pattern: OFF
40
CHAPTER 5 System Setup
¾ Command Path:
Unit Menu > (H) FOM ALS/APSD Setup
¾ Configuration:
Field Setting Options Default
ALS Enable ON, OFF OFF
Pulse repetition time for 60~300 300
automatic restart (sec)
FOM P1~P7 Power Down ON, OFF OFF
FOM P1~P7 Manual Restart Start, OFF OFF
¾ How to Set up:
ALS Enable-
The 7 FOM card supports ALS (Auto Laser Shutdown) function. When ALS enable is set as “OFF”, the
laser function will remain active even if the optical line is disconnected (LOS alarm).
If you wish to disable the ALS function, select “ON” for ALS enable. The laser function will then shut
(shuts/will shut) down when an optical line is disconnected. After the optical line is re-connected, the
laser function will not restart automatically. To restart the laser function, you have to choose “START”
for FOM port (P1~P7) manual restart. You can also key in the automatic restart time you wish in the
“Pulse repetition time for automatic restart” section.
Power Down-
If you wish to disable the laser function for a particular FOM port with a connected optical line, select
“ON” for FOM port (P1~P7) power down. The port will then stop sending Tx.
Unit 1 7FOM === FOM ALS/APSD Setup === 19:16:44 06/23/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
41