SERVICE BULLETIN LM2500-IND-164
4 December 2001
GE PROPRIETARY INFORMATION
I. PLANNING INFORMATION
A. Effectivity
LM2500+ gas generators, serial numbers 636-050, 636-051, and 636-101 through
636-106, are affected by this Service Bulletin.
LM2500+ gas turbines, serial numbers 559-101 through 559-110, 642-101 through
642-107, 642-109 through 642-135, and 642-137 through 642-144, are affected by
this Service Bulletin.
B. Reason
This Service Bulletin introduces an improved 2-cup fuel nozzle which has a modified
A-cup fuel circuit effective area requirements that reduce the ELBO flow from
14 percent to 9 percent of the overall A-ring fuel flow. The improved fuel nozzle
should reduce NOx emissions by 2-4 ppm at the uprated T48 limit of 1546° F
(841.1° C) at ambient temperatures of 10-120°F (-12.2 to 48.9°C).
OPTIONAL
Page 1 of 5
SERVICE BULLETIN LM2500-IND-164
4 December 2001
C. Description
This Service Bulletin provides instructions for replacing the 2-cup fuel nozzles.
D. Compliance
E. Manpower
F. Materials
The cost and delivery for this material will be quoted upon request or upon receipt of
purchase order submitted to the address below:
Page 2 of 5
G. Tooling
H. References
I. Previous Modifications
None.
J. Reidentification
Not applicable.
B. Install new fuel nozzles, PN L47197P06, per GEK 105048, WP 101 00.
A. Configuration Chart
B. Interchangeability
C. Parts Disposition
Page 3 of 5
Compliance with this Service Bulletin must be entered in local records. The attached
Service Bulletin Compliance Record form must be completed and returned to the
address indicated on the compliance form.
Page 4 of 5
MATERIAL INFORMATION
(ADDED, DELETED, OR REPLACED HARDWARE)
NOMENCLATURE PART NO. SERIAL NO. QTY NOMENCLATURE PART NO. SERIAL NO. QTY
Mail this form to: Strategic Power Systems, Inc. PHONE: (704) 544-5501
Piedmont Bldg. - Koger Center FAX: (704) 544-5505
Suite 308
11301 Carmel Commons Blvd.
Charlotte, NC 28226, USA
Comments:
Page 5 of 5