OPERATING INSTRUCTIONS

194/1543-LZA 701 6003 Uen F


Copyright

© Ericsson AB 2011–2014. All rights reserved. No part of this document may be


reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use
of this document.

Trademark List

All trademarks mentioned herein are the property of their respective owners.
These are shown in the document Trademark Information.

194/1543-LZA 701 6003 Uen F | 2014-04-22


Contents

Contents

1 Overview 1
1.1 Description 1
1.2 Prerequisites 3

2 Procedure 4
2.1 Analyzing Alarm 4
2.2 Actions for Wrongly Connected Cable 4
2.3 Actions for Configuration Correction 4
2.4 Actions for EcPort 4

194/1543-LZA 701 6003 Uen F | 2014-04-22


InconsistentConfiguration

194/1543-LZA 701 6003 Uen F | 2014-04-22


Overview

1 Overview

This instruction concerns alarm handling.

1.1 Description
The alarm is a primary alarm. The alarm is issued by the DeviceGroup,
DigitalCable, and EcPort Managed Objects (MOs).

The possible alarm causes and fault locations are explained in Table 1.

Table 1 Alarm Causes

194/1543-LZA 701 6003 Uen F | 2014-04-22 1


InconsistentConfiguration

Table 1 Alarm Causes


Alarm Description Fault Reas Fault Impact
Caus on Locat
e ion
The software on
radio units in Devic
Antenna Integrated eGrou The AIR unit is degraded or failed.
Radio (AIR) unit is p MO
incompatible.
When the Increased
CC Support for DUW
Devic
feature is enabled,
eGrou
this alarm is issued
p MO
in the case when
(Digital The traffic on the affected DUW board
two Baseband (BB)
Unit is down.
pools are configured
Inter
on one Digital Unit
face
WCDMA (DUW) that
(DUI))
does not support
(1)
multiple BB pools.
DU reported a
physical radio
equipment port
Digit
connection that does The traffic in the affected sector is
alCab
not correspond to down.
le MO
the configured radio
equipment port for a
CONF sector.
IGUR The consequence can differ
ATIO depending on which parent MO the
Hardware
N_OR EcPort MO belongs to.
and conf
_CUS
iguration • EcPort MO with parent HwUnit
TOMI
mismatch. MO:
ZING
_ERR The RBS can be unable to
OR communicate with or control the
hardware unit. The HW unit can still
work in an autonomous mode, which
results in a reduced performance. It
depends on the type of HW unit if
the performance is reduced.
The hubPosition
attribute either does • EcPort MO with parent
not contain a proper ExternalNode MO:
EcPor Climate control in the cabinet
value or the value t MO
of the attribute is cannot be adapted to Secondary
already assigned to Node HW Unit needs. HW unit
another EcPort MO. can also be overheated. The HW
unit can provide reduced service or
performance but there is no risk of
HW unit damage.
• EcPort MO with parent
2 PlugInUnit MO:
194/1543-LZA 701 6003 Uen F | 2014-04-22
Climate control in the cabinet
cannot be adapted to Secondary
Node HW Unit needs. HW unit
Overview

Table 1 Alarm Causes


(1) Refer to the WCDMA RAN Increased Cell Carrier Support for DUW for information on the DUW supporting
multiple BB pools.

1.2 Prerequisites
This section provides information on the documents, tools and conditions that
apply to the procedure.

1.2.1 Documents

Before starting this procedure, ensure to that you have read the following
documents:

• System Safety Information

• Antenna and RF Connections

• Element Manager

• Installing RBS

• Modifying Configurations

1.2.2 Tools
No tools are required.

1.2.3 Conditions
Before starting this procedure, ensure that the following conditions are met:

• A work order, or this instruction referenced from another instruction is


available.

• The alarm is acknowledged in the RBS Element Manager (EM) alarm list.

• Access to other documentation referenced within this instruction is


available.

• Access to the site is secured if required for on-site activities.

• Access to the RBS EM is established.

• The alarm is not automatically cleared by the system.

194/1543-LZA 701 6003 Uen F | 2014-04-22 3


InconsistentConfiguration

2 Procedure

This section describes the procedure to follow when the alarm is issued.

2.1 Analyzing Alarm


To clear the alarm, the following solutions are available:

• Check if the AIR is degraded or failed, contact the next level of maintenance
support.

• Check if the cable stated in the alarm is connected to the correct port,
see Section 2.2 on page 4.

• Check if the configuration is correct and complies with the cable


connections or the DUWs, see Section 2.3 on page 4.

• Check if the hubposition is given a proper value, see Section 2.4 on


page 4.

2.2 Actions for Wrongly Connected Cable


To correct the wrongly connected cable, do the following:

1. Reconnect the cable stated in the alarm and use the correct port.

2. Confirm that the alarm is cleared. If the alarm remains, see Section 2.3
on page 4.

2.3 Actions for Configuration Correction


To modify the configuration, do the following:

1. Create an XML input file, unless a prepared XML file already exists.

2. Run the Modify RBS Equipment Configuration application with the XML
input file as instructed in Modifying Configurations.

Note: This action affects cells and causes traffic disturbance.

3. Confirm that the alarm is cleared. If the alarm remains, contact the next
level of maintenance support.

2.4 Actions for EcPort


To clear the alarm, do the following:

4 194/1543-LZA 701 6003 Uen F | 2014-04-22


Procedure

1. Check if the hubposition is given a proper value, that is, the value is
set to the port to which the hardware unit is connected in the hub. The
hubposition value is not configured for any other EcPort MO.

2. Check that the alarm is cleared.

3. If the alarm remains, contact the next level of maintenance support.