Professional Documents
Culture Documents
250000
Lynnwood Link Opens
(Anticipated)
200000
100000
0
2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026
Year
Lynnwood Link
• $2.8B Program
• Length: 8.5 miles
total. 4 mi. of
Aerial Guideway
• Start of Service:
2024
• 70,000 daily
riders by 2035
Images by Sound Transit
East Link
E340:
• $100M
• 1.1 miles
• 0.3 miles
Aerial
• 130th
Station
(At-Grade)
• $90M/mile
East Link Construction Cost
E320:
• $321M
Construction
Cost
• 2.4 miles total
• 1.1 miles
Aerial Image by Sound Transit
Aerial
$10,000 - $11,000 per LF Superstructure
14%
Guideway Drilled Shaft
22% 27%
Track Slab
19%
Column/Bent
Cap 16%
Other Precast
Girders 24%
Superstructure – Type Selection
East Link
Superstructure – Span Optimization
• NCHRP Research Report 851 – Proposed • UIC (International Union of Railways) 776-2R -
AASHTO LRFD Bridge Design Specifications Deflection Limits for Keep Vertical Acceleration < 0.1g
for Light Rail Transit Loads (2017)
Δ = L/1000
LLE
East Link
Δ = L/600
100ft 130ft 165ft
Superstructure – Rider Comfort
• At Passenger Level
UIC 776-2R Table 2: Indicative levels of comfort
Level of Comfort Vertical Vertical
2
Acceleration (m/s ) Acceleration (g)
Very Good 1.0 0.10g
Good 1.3 0.13g
Acceptable 2.0 0.20g
Superstructure – Limit Vibrational Amplification
Summary:
• Frequency criteria is controlling span length on Sound Transit projects
• Based on research by Sound Transit and HNTB|Jacobs, a deviation was
granted to decreased frequency requirement from 3.0 Hz down to 2.5 Hz
• Still concerns with frequencies < 2.5 Hz resonating with light rail vehicle
Looking back to a path forward
Column Design:
• Seismic Load Combinations (MDE and ODE) control
column and foundation size and strength
ODE Performance Goal: Fully Operational Column Cross Section at Base of Column
• 1% Column Drift
CU ODE
MDE Displacement Capacity per AASHTO SGS typically 0.002
Seismic Analysis and Demand
1.40
1.20
0.80
ST MDE (2500 yr)
0.60
ST ODE (150 yr)
0.40
0.20
0.00
0 1 2 3 4
Period, T (seconds)
• Drift limit control capacity for ODE Column Displacement Capacity and Demand vs Bent Height
8
tall columns
7
ODE Strain Limits Control 1% Drift Controls
Displacement (inch)
5
0.7
0.6
Bent Vp/DC
0.5
FBD - ODE LC Control
0.4
0.3
0.2
DBD - Strength LC Control
0.1
0.0
10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0
Bent Height (ft)
East Link
Segment D ODE Redesign
Take Aways:
East Link Quantity Comparisons
• Change takes time
• More engineering costs less than more
construction
• Displacement based design is being used for
Lynnwood Link Extension – 4 miles of Aerial
Guideway
Acknowledgements