You are on page 1of 1

Client DNO Calculation:

Project Benennan-3 EPF By: ______


System Tanks Venting to Flare Checked: ______
Case T-1400 A Revised: 24-Mar-2018, 16:45

FROM: Tanks Depadding PCV Tanks Depadding PCV Verical Flare


TO: Depadding PCV Verical Flare Depadding PCV Verical Flare
Line Number

Inlet pressure bar(g) 0.150 0.098 0.300 0.244


Outlet pressure bar(g) 0.098 0.036 0.244 0.036
FLUID PROPERTIES Nm3/hr 412.0 100 % margin on flow rate
Phase Vapour Vapour Vapour Vapour
Normal flowrate kg/h 515 515 515 515
Flowmeter max flow kg/h
Temperature °C 40.0 40.0 40.0 40.0
Z 0.990 0.990 0.990 0.990
MW 28.00 28.00 28.00 28.00
Density kg/m³ 1.3 1.2 1.4 1.4
Viscosity cP 0.012 0.012 0.012 0.012
SIZING
Nom Pipe Size inch 4 4 3 3
Schedule (Typical) 40 40 40 40
Pipe ID inch 4.026 4.026 3.068 3.068
Velocity m/s 13.775 14.422 21.012 21.953
Pressure loss bar/100m 0.023 0.024 0.080 0.083
Mach No 0.038 0.042 0.059 0.063
PIPING DATA
Length m 2 250 2 250
Elbows 5 10 5
Straight tee
Branch tee
Gate / Ball valves 2 2
Swing check valves
Strainer
Reducer
Downstream pipe NB inch
Downstream pipe ID inch
Flow into pipe
Exit from pipe
Other vel. head
Total vel heads 1.800 49.616 2.004 63.148
Total Eq.length m 9.468 260.953 7.933 250.000
CONTROL VALVE
Control valve tag No PCV PCV
dP control valve bar 0.05 0.05
Liquid vapour pressure bar(a)
Liquid critical pressure bar(a)
Vapour Cp/Cv 1.4 1.4
Max Ratio CVcalc / CV inst 0.7 0.7
CV required 77 72
Preliminary valve 4" globe 3" globe
CV installed 195 110
CV calc / CV inst 0.396 0.659
FLOWMETER
Flowmeter tag No
Flowmeter type
FE meter max kg/h
FE meter range inch WG
FE d/D ratio
FE hole dia inch
FE dP @ normal flow bar
MISCELLANEOUS LOSSES
Equipment Item No
Equipment dP bar
Other - description
Other dP bar
Total frictional dP (exc. CV) bar 0.002 0.062 0.006 0.208
Static head pressure gain m
Static head bar

C:\Users\eu1324\Documents\BN3\[Depadding PCV outlet.xlsm]Single Phase (2) PAGE 1