Table of Contents
Page
1.0 Introduction 3
1.1 Definition 3
1.2 Purpose and Scope 3
1.3 Intended Users 4
1.4 Initial Assessment Objectives 4
3.0 Methodology 3
3.1 Energy Flow Diagrams 7
3.2 Steam and Power Diagram 11
3.3 Fuel Diagram 12
3.4 Energy Saving Housekeeping List 13
3.5 Energy Saving Generic Checklist 14
Page 2 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
1.0 Introduction
A vital contribution towards the success of the company wide energy conservation
policy comes through documenting the company best practices in methodology, tools
and applications in the field of energy conservation and distributing such knowledge
among our facilities. Hence, a consistent effort has been exerted in Saudi Aramco to
produce Best Practices to help Saudi Aramco plants achieve their energy conservation
targets and disseminate energy conservation knowledge. This particular Best Practice
document for initial energy assessment is a contribution towards this goal. It is
expected to draw the line in conducting energy assessments through a user-friendly
methodology.
The theme of this quick energy assessment methodology for energy efficiency
optimization is, “Big Picture First, Details Later”.
1.1 Definition
The term “Energy Assessment” refers to the methodology of collecting and analyzing
available energy utilities related data in order to establish the “big picture” of the
breakdown of energy consumption for a particular facility and identify component-
based-energy saving opportunities within the facility.
The purpose of this best practice document is to describe a methodology and introduce
short cut tools by which quick assessment for energy efficiency improvement can be
conducted faster, cheaper and better. Its scope include quick energy assessment
methodology in a step-by-step manner, simple models for data representation,
checklists for identifying areas for energy savings and short cut tools for creating and
evaluating process initiatives for energy saving for common use in Saudi Aramco
plants.
Page 3 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
This Best Practice manual is intended for use by the energy engineers working in
Saudi Aramco plants, who are responsible for efficient operation of their facility. This
particular document will enable them to conduct quick energy assessments
systematically.
The first priority in any plant initial energy assessment effort is to define the “quick hits”
for energy cost savings that can be achieved with little or no investment.
The best practice document does not only help plants energy groups conduct a quick
energy assessment for both short and long term energy savings opportunities but also
establish the procedures and checklists that can enable process engineers and
operators make intelligent choices on hour-to-hour basis.
Page 4 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
“Given an industrial facility that consists of several processes and utility plants, define;
at minimum deficiency in energy utility systems supply to the process; near-optimal
targets for energy consumption minimization, find a list of possible operational and
design modifications to achieve desired target(s) and conduct the engineered
solutions”
For simplicity and timely results, Decomposition Techniques will be used in lieu of the
time-consuming Mathematical Programming/Optimization Techniques.
The plant’s energy utility needs will be defined with reasonable level of flexibility and
the energy utility system; electricity, fuel, steam and other energy-related utilities will be
scrutinized one by one to find the near- optimal consumption of such utilities that
guarantee minimum deficiency in the utility supply to plant processes.
On the macro level the energy system components are generation, distribution and
utilization. The objective will be to minimize waste in energy fresh resources and
capital (de-bottlenecking) in these three components. This can be done via the
continuous upgrade of the efficiency of energy system components in generation,
distribution and utilization. However, the utilization component has a unique feature,
where its boundaries are not completely dictated by the process. Therefore the room of
improvement in this component is much wider than the others.
3.0 Methodology
There are four essential tasks that can be conducted by a small energy focus group of
three engineers:
Page 5 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
2. Define the criteria for focusing on potential areas of interest (when to be rigorous
and get to the second level of details)
3. Develop site energy/utility nominal design/normal operation models with the
appropriate level of details in a high level generic “path” diagrams for, power, fuel,
H2, steam, water, nitrogen and air. Preliminary purpose of these models will be to
understand what is going on in the energy utility system, locate the “energy
consumption elephants” (ECEs) in both process and utility plants and generate
insights for energy saving opportunities
4. Add more depth in the level of details of the energy utility model for each ECE
and/or other criterion of focus
5. Define the effect of disturbances and uncertainty on the energy utility system
models
a. Sources of disturbances
b. Site energy utility balance under disturbances
c. Nominal and dynamic targeting of energy utility systems
d. (Check that the “big picture” depicted for the process and the utility plants is
correct with enough degree of confidence before you proceed)
6. Target (order of magnitude targeting)
a. _ Identify main processing issues that affect utility utilization
b. _ Link utility-utility interactions
c. _ Integrate and qualitatively optimize site utilities (If we do not coordinate
between steam and fuel systems we may stop flaring steam but flaring
fuel) for energy utility saving
7. Integrate core processes among themselves and with utilities
8. Develop a comprehensive initiatives list via identifying and estimating energy
utility savings opportunities
a. Housekeeping list
b. Checklists (generic and process specific)
c. Waste energy recovery (pinch method and others)
d. In-process Modification (pinch method and others)
9. Champion a cross-fertilizing discussion among plant disciplines to prioritize,
screen the initiatives and writing a project sheet, for each initiative, including a
description of the opportunity and energy utility savings estimate
10. Develop “word” strategies for realizing savings from facility goals, analysis of the
results and the mapping of the opportunities onto the facility strategy (remember,
50% of something is better than 100% of nothing). Then report and present
results.
Page 6 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
3.1.1 Overview
Fuel
Energy Sources
Energy
Generation
Steam Energy
Electricity
Distribution
Energy
Buildings & Others Process
Utilization
Energy
Byproducts
The task now is to look for the “Elephants” in the energy-process system.
The graphs below will enable the Energy Engineer to find the “Elephants” to focus
his/her efforts and decide where to start and insist on accurate data collection to further
proceed with the analysis.
Money-based graphs will help quickly to pinpoint the areas of focus. Furthermore, the
BTU-based graphs will double check the pre-defined priority list, direct the study
towards the process reasons behind certain energy “elephant” and find more efficient
ways to satisfy the process target(s).
Page 7 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
$ 0.5 MM
$ 0.9 MM
Other users
Process
Purchase
$ 52.4 MM $ 0.8 MM Machine
$ 24.4 MM Drive
$ 21.5 MM $ 0.4 MM
Flare
$ 20.70 MM
Fuel $ 51.2 MM
furnaces
$ 73.1 MM
$ 0.0 MM
$ 0.3 MM
refrigeration
$ 16.9 MM $ 2.2 MM
power $ 18.4 MM
Motors
$ 19.1 MM
$ 0.40 MM Other users
Total Purchased $ 37.6 MM $ 0.0 MM
Export
Page 8 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Export
SA Fuel
Purchase Gas
Page 9 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
0.39 TBtu 1.8 TBtu -0.19 TBtu 5.46 TBtu 0.12 TBtu - 5.4 TBtu
0.5 TBtu 2.11 TBtu 5.77 TBtu
Boilers Boilers Boilers
Process steam Process steam Process Building steam
Building Building
cogen cogen cogen
Boiler Conventional
Conventional Boiler Boiler
Fuel Conventional Electricity
Electricity Fuel Fuel
Electricity
#N
Area #1 #N Area #1 Area #1 #N
Unit #1 #N
Unit #1 #N Unit #1 #N
Page 10 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Steam “big picture” shall exhibit at least steam sources, pressure levels, mass balance,
let down valves and turbines, main users and losses such as vents, let downs and
condensate. These information can be used as depicted in the way below to generate
ideas and opportunities for saving under the main theme of “Big picture first, and
details later.”
Steam Targets
103 t/h
Consider replacing turbines with motors Enhance the recovery of
Steam from condensate
6.28 MW
Reduce it via HP Process
operating at Proc. #2 Condensate
lower pressure
1 t/h
4 t/h
MP Boiler 68 t/h 0.0 t/h
chemicals
MP
Eliminate vent 27 t/h 13 t/h
Vent 30 t/h
MP Process
2 t/h Proc. #4 Condensate
Proc. #1 2 t/h
18 t/h
0.0 t/h Vent
40 t/h
Deaerator 1 t/h 0.0 t/h
30 t/h 0.0 t/h
BFW LP
49 t/h 7 t/h 4 t/h
Raw water Effluent 5 t/h LP Process
Make-up Treatment Plant Proc. #1 Proc. #3
Condensate
Process Condensate
Reduce and make use of boiler blow-down
Est. 50 % Returned
Page 11 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Fuel “big picture” shall exhibit at least fuel sources, pressure levels, mass balance, let
down valves and compressors and main users. Hydrogen composition should also be
considered to define the opportunities for recycles.
400 psig
380 psig
PSA
350 psig
180 psig
NG
52 psig
50 psig
boilers furnaces
15 psig
5 psig
Page 12 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
1. Establish steam trap auditing program to determine the number of traps (working,
leaking, blocking…etc.) and periodically check it and repair or replace the
defected ones
2. Condensate recovery (maintenance and operation)
3. Piping insulation (maintenance)
4. Shutting off equipment when not required (load management)
5. Minimize slow rolling of steam turbines
6. Boilers and furnaces tuning through better combustion control
7. Preventive maintenance of energy system components such as heat exchangers,
pumps, fans, compressors, turbines, furnaces, boilers (e.g., clean the fin fan tubes
of gas coolers)
8. Improved cooling water system (maintenance and operation)
9. Optimize air compressors operation
10. Optimize BFW pumps load allocation
11. Energy monitoring and indices/ energy management system
12. Shut down compressors at low feed rate (load management)
13. Steam trap management (consider self regulating electrical tracing)
14. Booster, shipper and condensate pumps load management
15. Compressors load management
16. Consider the use of Economizers and Pre-heater in the boilers
17. Compressed air leaks (maintenance)
18. Minimize boilers and water coolers blow downs
19. Utilize boiler blow-down
20. Turbines load management
21. Upgrade sluggish response control valves since the delay might result in extra
flaring
22. Enhance the efficiency of boilers and furnaces through tight control
23. Enhance boilers and furnaces insulation
24. Optimize the CHP system
Page 13 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Page 14 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
22. Boilers and furnaces efficiency enhancement through advanced process control,
on-line performance monitoring and optimization
23. Recover condensate
24. Thermal Heat and power integration (CHP)
25. Better control for dispersion steam to flare stacks
26. Optimize steam use in strippers
27. Minimize live steam utilization
28. Mechanical energy integration
29. Reduce natural gas consumption by understanding fuel gas sinks and constraints
30. Reduce fuel gas use with energy integration
31. Keep H2 separate from fuel gas system
32. Measure the composition of off-gas streams and recover C2 and C3+
33. Avoid unnecessary processing of off-gas
34. Avoid unnecessary processing of wastes and inert
35. Minimize the unnecessary production of off-gas
36. Use on-line monitoring and APC for furnaces and other control sensitive fuel users
37. Avoid unnecessary recycles
38. Avoid leaks in the pressure relieve valves to the fuel system
39. Adjust operating pressures and optimize process interaction
40. Clean and maintain pipelines and valves to minimize pressure drops
41. Clean and maintain Boiler tubes from deposits & scale for better operations
42. Treat and recycle blow down to force lower cycles of concentration in cooling
towers and boilers
43. Use lowest quality water
44. Maximize use of stripped sour water
45. Minimize generation of wastewater
46. Seek out and repair all hydrocarbon leaks
47. Eliminate direct water injection for cooling purposes
48. Eliminate live steam used for re-boiling and stripping where it is only used for BTU
value
49. Minimize or eliminate live steam consumption in sour water strippers by replacing
it with re-boilers
Page 15 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Revision Summary
28 December 2005 New Saudi Aramco Best Practice.
Page 16 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The basic Steam Mass Balance does not require high accuracy as long as the
developed model still makes sound engineering sense. (i.e., output is much higher than
input).
Common engineering sense shall be used to estimate what the unknowns. For
example condensate return, blow-down and flares can be defined after getting good
idea about main consumers.
98+5 t/h
98 t/h
HP Boiler
HP
68 t/h 21 t/h 8 t/h 0.0 t/h 0.0 t/h
Proc. #1
1 t/h
6.28 MW
HP Process
Proc. #2 Condensate
0.0 t/h
MP Boiler 68 t/h 0.0 t/h
chemicals
MP
27 t/h 9 t/h
Vent 30 t/h
MP Process
Proc. #4 Proc. #1 Condensate
2 t/h
18 t/h
0.0 t/h Vent
38 t/h 1 t/h
Deaerator 0.0 t/h
30 t/h 0.0 t/h
BFW LP
(42+5) t/h 7 t/h 4 t/h
Raw water Effluent 5 t/h LP Process
Make-up Treatment Plant Proc. #1
Proc. #3
Condensate
Process Condensate
Est. 50 % Returned
Page 17 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The purpose of this section is not to conduct a pinch study but to get some energy
targets regarding the utilities consumption for a desired plant area. This can be done
essentially via three methods, graphical, algebraic and using mathematical
programming/optimization. In this document the first two methods are going to be
explained.
Graphical Method:
Background:
Any heat exchanger can be represented as a hot stream that is cooled down by
another cold stream and/or cold utility and a cold stream that is heated up by a hot
stream and/or hot utility with a specified minimum temperature approach between the
hot and the cold called ∆Tmin.
The process exhibited below in the graph shows the situation when the two streams do
not have a chance of overlap that produce heat integration between the hot and the
cold.
Page 18 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Feed Product
H PROCESS C
120
T HOT UTILITY
100
80
60
40
20
0
0 10 20 30 40 50 60 H
COLD UTILITY
Page 19 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Moving the cold stream to the left on the enthalpy axis without changing its supply and
target temperatures till we have small vertical distance between the hot stream and the
cold stream we obtain some overlap between the two streams that result in heat
integration between the hot and the cold and less hot and cold utilities. As been
depicted in the graph below with shrinkage in the hot and cold lines span.
Feed Product
H PROCESS C
120
T HOT UTILITY
100
HEAT
80
RECOVERY
60
Pinch
(MAT)
40
20
H
COLD UTILITY
0 10 20 30 40 50 60
For demonstration, all hot streams will be represented in the process by one long hot
stream to be called “the hot composite curve”. Same thing be done for all cold streams
in the process.
Page 20 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The next step will be drawing the two composite curves/lines on the same page in
Temperature (T)-Enthalpy diagram with two conditions:
1- The cold composite curve should be completely below the hot composite curve,
and
2- The vertical distance between the two lines/curves in terms of temperature should
be greater than or equal to a selected minimum approach temperature called global
∆Tmin
The resulting graph is depicted below and known as thermal pinch diagram:
Opportunity for
heat recovery
Page 21 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Stream Type Supply Temperature (ºC) Target Temperature (ºC) FCp (kW/ ºC)
1-Hot 170 70 10
2-Hot 120 30 20
3-Cold 50 90 40
4-Cold 20 110 18
1- Draw the hot composite curve and the cold composite curve via developing the
following tables.
Note: The tables list all the hot and cold streams temperatures in an ascending order
with the cumulative enthalpy corresponding to the lowest hot temperature and
lowest cold temperature respectively equal to zero.
2- In every temperature interval the cumulative hot load is calculated using the
following formula:
3- In every temperature interval the cumulative cold load is calculated using the
following formula:
T0=30 H0=0.0
T1=70 H1=800
T2=120 H2=2300
T3=170 H3=2800
Page 22 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
T0=20 H0=0.0
T1=50 H1=540
T2=90 H2=2860
T3=110 H3=3220
30
20
Cold composite curve is not completely below the hot composite curve
Page 23 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
As we mentioned before the cold composite curve shall lie completely below the hot
composite curve and this can be done via dragging the cold composite curve to the
right on the enthalpy axis (H). This process shall stop at a vertical distance between
the cold and the hot composite curve for a temperature equal to the minimum
temperature approach selected earlier.
30
20
Qc=60 kW
Page 24 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Algebraic Method:
Information needed
Given a unit with a list of hot streams to be cooled and cold streams to be heated
Stream ID Type Flowrate*Average Specific heat (FCp) Supply temperature Target Temperature
1.1_ Draw two temperature scales one for the hot streams and another for the cold
streams
1.2_ Select reasonable minimum temperature approach between the hot streams and
the cold stream (for instance, 10ºC)
1.3_ Draw all the hot streams (in the table hot section) to be cooled according to the
hot steam scale as arrows that start at the supply temperatures and end at the
target temperatures
1.4_ Repeat step 1.3 for all cold streams in the cold section of the table
1.5_ Start at the highest temperature of any hot stream in the hot section and draw a
horizontal line that span along the two sections of the table, the hot and the cold.
1.6_ Draw horizontal lines again at the start and the end of any arrow representing the
hot streams in the hot section of the table
1.7_ Repeat step 1.6 for any arrow representing cold stream in the cold section (at the
start and the end of any arrow)
1.8_ Count the number of segments generated and number them starting at the
highest temperature (they are called temperature intervals)
1.9_ Make sure that each temperature interval has now temperature value on both the
hot temperature scale and cold temperature scale. The difference is the desired
minimum temperature approach (for instance the 10ºC used in this example)
Page 25 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Note: This structure means that within any temperature interval it is thermodynamically
feasible to transfer heat from the hot streams to cold streams. It is also feasible
to transfer heat from a hot stream in an interval “x” to any cold stream which lies
in an interval below.
∆ T minimum = 10 K
T* Interval
Hot Streams Cold Streams
T t
555 560 550
1 H1
515 520 510
2
385 390 380
375 3 H2 380 370
4 330 320
310
5 310 300 C2
305
6 C1
295 300 290
Hot Streams:H1; F1Cp1= 10 kW/K Cold Streams:C1; F1Cp1= 10 kW/K
H2; F2Cp2= 5 kW/K C2; F2Cp2= 5 kW/K
Page 26 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Note: The temperature symbol T* is interval inlet temperature used later on selecting
the suitable energy utility after calculating the targets using what is known as
grand composite curve.
To calculate T* we take the average interval inlet temperature of the hot and cold
temperature scale.
2.1 Determining individual heating loads and cooling capacities of all process streams
for all temperature intervals using this formula:
Example 1:
Example 2:
Page 27 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Then,
Example 3:
The flow specific heat of this cold stream is F1Cp1 = 119 kW/K
Then,
2.2 Obtain the collective loads (capacities) of the hot (cold) process streams.
These collective loads (capacities) are calculated by summing up the individual loads
of the hot process streams that pass through that interval and the collective cooling
capacity of the cold streams within the same interval.
Page 28 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
These calculations for the above problem are shown in the following tables:
Page 29 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
This diagram is constructed using the total hot loads and cooling capacities obtained in
the previous step for each temperature intervals.
The temperature intervals are drawn as “rectangular” with two inlets and two outlets.
The inlet from the left is the total hot load available in this interval (for instance,
1300 kW in case of interval # 2).
The inlet from above is the utility input load, in case of the first interval, or the input
from interval above in case of second, third,……,N intervals.
The output from the right is the total cooling capacity of this interval (for instance,
2470 kW in case of interval #2).
The output from the bottom is the difference between the total inputs and the cooling
capacity of the interval.
Page 30 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
“Top Input”
Hot Load From Process Source Cooling Capacity From Process Source
Heat Balance
Page 31 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Hot Load From Process Source Cooling Capacity From Process Source
Page 32 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
“Top Input”
Hot Load From Process Source Cooling Capacity From Process Source
“Bottom Output”
Heat Balance
Page 33 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Hot Load From Process Source Cooling Capacity From Process Source
Heat Balance
Top Input+ Left Input- Right Output = Bottom Output
- 760 + 1300 -2470 = -1930
Page 34 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Upon the completion of heat balance around each interval the following diagram will be
produced:
Note: During this step the input from Hot Utility to the first interval is equal to zero
0.0
0.0 1 760
- 760
1300 2 2470
- 1930
100 3 210
- 2040
750 4 1050
-2340
100 5 380
- 2620
50 0.0
6
- 2570
The maximum difference between the available hot loads and cooling capacities from
the heat balances of these intervals is – 2620 kW.
Page 35 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
This value will be the input (from the top of the first interval) and the same heat balance
calculation conducted above will be repeated to produce the balanced thermal
cascade diagram below.
0.0 1 760
1860
1300 2 2470
690
100 3 210
580
750 4 1050
280
100 5 380
Thermal Pinch
0.0
50 0.0
6
Minimum Q-cooling = 50 kW
With the completion of this step, now the minimum heating utility and minimum cooling
utility required are 2620 kW and 50 kW respectively.
These targets can give some idea about the potential of utility saving in the facility.
To get better idea in terms of utility types needed, diagram known as grand composite
curve shall be drawn to be used in defining kind of utilities needed and compare it with
the current facility needs from such utility. This step will help in capturing some
potential savings upon the heat integration of certain process area.
Page 36 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
This curve will be drawn between T* calculated before and the corresponding top heat
inputs to each interval.
555 2620 kW
1
T* (K) 515 1860 kW
2
385 690 kW
3
375 580 kW
4
310 280 kW
5
305 0.0 kW
Thermal Pinch
6
295 50 kW
Enthalpy ( kW)
Page 37 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Drawing these data as T* versus Enthalpy results in the following diagram that can be
used to define different levels of utilities that can be used to satisfy the process heating
utility requirement as shown below.
600
Hu3
Hu2
500
Hu1
400
300
Enthalpy ( kW)
200
700 1400 2100 2800
Page 38 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Upon maximizing heat recovery in the heat exchanger network, those heating duties
and cooling duties not serviced by heat recovery must be provided by external utilities.
The most common utility is steam. It is usually available at several levels. High
temperature heating duties require furnace flue gas or a hot oil circuit. Cold utilities
might be refrigeration, cooling water, air cooling, furnace air preheating, boiler feed
water preheating, or even steam generation at higher temperatures.
Although the composite curves can be used to set energy targets, they are not a
suitable tool for the selection of utilities. The grand composite curve drawn above is a
more appropriate tool for understanding the interface between the process and the
utility system. It is also as will be shown in later chapters a very useful tool in studying
of the interaction between heat-integrated reactors, separators and the rest of the
process.
The GCC is obtained via drawing the problem table cascade as we shown earlier.
The graph shown above is a typical GCC. It shows the heat flow through the process
against temperature. It should be noted that the temperature plotted here is the shifted
temperature T* and not the actual temperature. Hot streams are represented by
∆Tmin/2 colder and the cold streams ∆Tmin/2 hotter tan they are in the streams
problem definition. This method means that an allowance of ∆Tmin is already built into
the graph between the hot and the cold for both process and utility streams. The point
of “zero” heat flow in the GCC is the pinch point. The open “jaws” at the top and the
bottom represent QHmin and QCmin respectively.
The grand composite curve (GCC) provides convenient tool for setting the targets for
the multiple utility levels of heating utilities as illustrated above.
Page 39 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The graphs below further illustrate such capability for both heating and cooling utilities.
The above figure (a) shows a situation where HP steam is used for heating and
refrigeration is used for cooling the process. In order to reduce utilities cost,
intermediate utilities MP steam and cooling water (CW) are introduced. The second
graph (b) shows the targets for all the utilities. The target for the MP steam is set via
simply drawing a horizontal line at the MP steam temperature level starting from the
vertical axis until it touches the GCC. The remaining heat duty required is then satisfied
by the HP steam. This maximizes the MP steam consumption prior to the remaining
heating duty be fulfilled by the HP steam and therefore, minimizes the total utilities
cost. Similar logic is followed below the pinch to maximize the use of the cooling water
prior the use of the refrigeration.
Page 40 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The points where the MP steam and CW levels touch the GCC are called utility
pinches since these are caused by utility levels. The graph (C) below shows a different
possibility of utility levels where furnace heating is used instead of HP steam.
Considering that furnace heating is more expensive than MP steam, the use of the MP
steam is first maximized. In the temperature range above the MP steam level, the
heating duty has to be supplied by the furnace flue gas. The flue gas flowrate is set as
shown in graph via drawing a sloping line starting from the MP steam to theoretical
flame temperature Ttft.
If the process pinch temperature is above the flue gas corrosion temperature, the heat
available from the flue gas between the MP steam and pinch temperature can be used
for process heating. This will reduce the MP steam consumption.
In summary, the GCC is one of the basic tools used in pinch technology for the
selection of appropriate utility levels and for targeting for a given set of multiple utility
levels. The targeting involves setting appropriate loads for the various utility levels by
maximizing cheaper utility loads and minimizing the loads on expensive utilities.
Page 41 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
T-tft
(C)
T*
MP
CW
Refrigeration
Page 42 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Normally, Plant’s Operations have choices of many hot and cold utilities and the graph
below shows some of available options. Generally, it is recommended to use hot
utilities at the lowest possible temperature while generating it at the highest possible
temperature. And for the cold utilities it is recommended to use it at the highest
possible temperature and generate at the lowest possible temperature. These
recommendations are best addressed systematically using the grand composite curve.
Boiler House
And Power Plant
Fuel
Steam W
Turbines
Gas W
Turbines
BFW
Hot Oil preheat
Circuit
Heat W
Process Pump
Furnace
Cooling W
Towers
Refrigeration
Air preheat
Page 43 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The graph below shows that utility pinches are formed according to the number of
utilities used. Each time a utility is used a “utility pinch” is created. It also shows that
the GCC right noses sometimes known as “pockets” are areas of heat
integration/energy recovery. In other words it does not need any external utilities.
These right noses/pockets are caused by;
- Region of net heat availability above the pinch
- Region of net heat requirement below the pinch
Page 44 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
GCC curve can be used by engineers to select the best match between utility profile
and process needs profile. For instance, the steam system shown below needs to be
integrated with the process demands profile to minimize low pressure steam flaring and
high or medium pressures steam let downs. Besides it helps selecting steam header
pressure levels and loads.
HP Boiler
HP
Proc. #1
HP Process
Proc. #2 Condensate
MP Boiler
chemicals
MP
Vent
MP Process
Proc. #4 Condensate
Proc. #1
Vent
Deaerator
BFW LP
Raw water Effluent LP Process
Make-up Treatment Plant Proc. #1
Proc. #3
Condensate
Process Condensate
Page 45 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
T HP
MP
Process GCC
LP
BFW
CW
H
The superimposed steam system on the process grand composite curve shows that
while process heating needs can be achieved electricity can also be generated to
satisfy process demands and/or export the surplus to the grid.
Page 46 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The graph below shows how we can use the GCC not only to select utility type, load
but also to define the steam headers minimum pressure/temperature to minimize
driving force and save energy.
T Qh
HP
MP
LP
BFW
CW
Qc
H
Page 47 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Grand Composite Curve can also be utilized to select the load and return temperature
of hot oil circuits. The graph below shows that while in many cases the process pinch
can be our limiting point in defining the load (slop of the hot oil line) and the return
temperature of the heating oil. In some other cases the topology of the GCC is the
limiting point not the process pinch. This is also shown in the second graph below. This
practical guide to select the load and the target temperature of the hot oil circuits is
also applicable to furnaces as will be shown later in this chapter.
Process Pinch temperature is the Limiting temperature for the Hot oil return temperature
T*
T supply
Hot Oil
T return
Process CW
Pinch
Refrigeration
Page 48 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Process Pinch temperature is not the Limiting temperature for the Hot oil return temperature
But the topology of the GCC curve
T* T supply
Hot Oil
CP-min
T return
Process CW
Pinch
Refrigeration
Page 49 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Grand composite curve (GCC) can also be used to select the process refrigeration
levels and the synthesis of the multiple-cycles refrigeration systems as we did in the
steam system. The schematic graph below shows a simplified refrigeration system.
Condenser 25ºC
CW
Process -5ºC
0ºC
-40ºC
Process
-35ºC
-70ºC
Process
-65ºC
Work
Compressor
Page 50 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
The GCC as we mentioned before can be used to place the refrigeration levels as we
did with steam levels. The graph below shows how we can do that.
Tcw
- 5 ºC
- 40 ºC
- 70 ºC
Page 51 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
When a hot utility needs to be at a high temperature and/or provide high heat fluxes,
radiant heat transfer is used from combustion of fuel in furnace. Furnace designs vary
according to the function of the furnace, heating duty and type of fuel, and method of
introducing combustion air.
Outlet isentropic enthalpy can be obtained from steam tables knowing outlet isentropic
entropy and outlet temperature or pressure
Inlet entropy can be obtained from steam tables at inlet temperature and pressure
Outlet steam flow= Inlet steam flow (1- actual wetting factor)
Page 52 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Treject is the temperature at which heat is rejected to the cooling medium (water)
Tc is the temperature at which heat is taken into the refrigeration) cycle
Analysis on the exhaust from the boilers sometimes or most of the times in some
places reveals excess oxygen levels which result in unnecessary energy consumption.
This excess air defines a low efficiency on the combustion process. Portable or even
on-line flue gas analyzer can be used as a part of a rigorous boilers/furnaces
inspection program.
The optimum amount of O2 in the flue gas of a gas fired boiler is 2%, which
corresponds to 10% excess air. Controlling the combustion process could lead to at
least 2% fuel saving upon bringing the excess O2 from for instance 6% to 2%.
Cost saving $/year= Energy usage per year* % possible fuel savings* fuel cost
per unit of energy
Analysis on the exhaust from the boilers sometimes or most of the times in some
places reveals excess oxygen levels which result in unnecessary energy consumption.
This excess air defines a low efficiency on the combustion process. Portable or even
on-line flue gas analyzer can be used as a part of a rigorous boilers/furnaces
inspection program.
The optimum amount of O2 in the flue gas of an oil fired boiler is 4%. Controlling the
combustion process could lead to at least 1% fuel saving upon bringing the excess O2
from for instance 6% to 1%.
Page 53 of 54
Document Responsibility: Energy Systems Unit/ESD/CSD SABP-A-005
Issue date: 28 December 2005 Quick Energy Assessment Methodology
Next Update: 1 January 2009 for Energy Efficiency Optimization
Cost saving $/year= Energy usage per year* % possible fuel savings* fuel cost
per unit of energy
Energy saving in preheating boiler/furnace combustion air with stack’s waste heat:
If the intake air (air drawn from outside into the natural gas boiler) is at ambient outdoor
temperature unnecessary fuel will be consumed to heat up this combustion air. In order
to reduce fuel consumption, it is recommended to install recuperative air pre-heater on
the air intake of the boiler to preheat combustion air using heat which is exhausted
along with the combustion from the boiler.
Stack exhaust losses are part of all fuel-fired processes. They increase with the
exhaust temperature and the amount of excess air the exhaust contains. A high quality
air pre-heater could recover more than 40% of this waste heat. Therefore, the potential
savings from the installation of air pre-heater on the boiler is:
Note: The following attached pages are two curves and a table that can be used to
estimate the percentage of fuel savings.