Appendix 2

Plate Reports and Questions


CSWIP 3.1 Training Questions for Plate Butt Weld 3

Answers to be indicated on the Candidate Answer Template.

Weld Face

1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?

a Equal to or less than 0mm.


b 1-4mm.
c 5-6mm.
d 7-8mm.
e Accept.
f Reject.

2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a None observed.
b 40-60mm.
c 1-30mm.
d 75-100mm.
e Accept.
f Reject.

3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 60-70mm.
b 20-30mm.
c None observed.
d 5-18mm.
e Accept.
f Reject.

4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?

a 50mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-1 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?

a The area is between 15-25mm2.


b The area is greater than 100mm2.
c None observed.
d The area is between 70-90mm2.
e Accept.
f Reject.

6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?

a 2-3mm transverse crack.


b 15mm longitudinal crack.
c None observed.
d 9-14mm longitudinal crack.
e Accept.
f Reject.

7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 70-90mm.
b 30-60mm.
c None observed.
d 91-100mm.
e Accept.
f Reject.

8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?

a 3 total.
b 4 total.
c None observed.
d 1 total.
e Accept.
f Reject.

9 Sharp areas of mechanical damage (excluding hard stamping and pop marks): Which
answer best matches your assessment of the total number of areas and would you
accept or reject your findings to the given acceptance levels.

a More than 2 areas.


b 1 area.
c None observed.
d 2 areas.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-2 Copyright © TWI Ltd
Weld Root

10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?

a 2-3mm.
b 4-5mm.
c 0-1.
d Greater than 5mm.
e Accept.
f Reject.

11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a 2-3mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.

12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 40-55mm.
b 25-35mm.
c None observed.
d 1-10mm.
e Accept.
f Reject.

13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 30-45mm.
b 1-15mm.
c None observed.
d 16-29mm.
e Accept.
f Reject.

14 Root concavity or shrinkage: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels.

a 31-39mm.
b 18-22mm.
c None observed.
d 40-60mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-3 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 40-60mm.
b 5-8mm.
c None observed.
d 2-4mm.
e Accept.
f Reject.

16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 10-17mm.
b 1-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.

17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the total
number of items and would you accept or reject your findings to the given
acceptance levels?

a 2 observed.
b 1 item observed.
c None observed.
d 3 or more items observed.
e Accept.
f Reject.

18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?

a Individual pore diameter between 1-2mm.


b Individual pore diameter between 2-3mm.
c None observed.
d Individual pore diameter greater than 3mm.
e Accept.
f Reject.

19 Burn-through in the root area: Which answer best matches your assessment of the
total number of areas and would you accept or reject your findings to the given
acceptance levels?

a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-4 Copyright © TWI Ltd
20 Angular distortion: Which answer best matches your assessment and would you
accept or reject your findings to the given acceptance levels (measure from the weld
centreline to the plate edge).

a 3-4mm.
b 5-6mm.
c None observed.
d 1-2mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-5 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-6 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-7 Copyright © TWI Ltd
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Plate Butt Weld 4

Answers to be indicated on the Candidate Answer Template.

Weld Face

1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?

a Equal to or less than 0mm.


b 1-4mm.
c 5-6mm.
d 7-8mm.
e Accept.
f Reject.

2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a None observed.
b 30-50mm.
c 1-25mm.
d 100-120mm.
e Accept.
f Reject.

3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 12-18mm.
b 8-10mm.
c None observed.
d 2-6mm.
e Accept.
f Reject.

4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?

a 10-20mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-8 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?

a The area is between 0.5-5mm2.


b The pore is greater than 45-60mm2.
c None observed.
d The pore is between 20-30mm2.
e Accept.
f Reject.

6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?

a 2-3mm transverse crack.


b 15mm longitudinal crack.
c None observed.
d 9-14mm longitudinal crack.
e Accept.
f Reject.

7 Lack of fusion: Which answer best matches your assessment of the total
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 30-39mm.
b 40-55mm.
c None observed.
d 5-10mm.
e Accept.
f Reject.

8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?

a 2.
b 3.
c None observed.
d 1.
e Accept.
f Reject.

9 Sharp areas of mechanical damage (excluding hard stamping and pop marks): Which
answer best matches your assessment of the total number of areas and would you
accept or reject your findings to the given acceptance levels.

a 4 areas.
b 1-2 areas.
c None observed.
d 3 areas.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-9 Copyright © TWI Ltd
Weld Root

10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?

a 0.5-1mm.
b 1.5-2mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.

11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a 3-5mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.

12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 35-40mm.
b 20-25mm.
c None observed.
d 1-10mm.
e Accept.
f Reject.

13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 28-35mm.
b 1-10mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.

14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total length and would you accept or reject your findings to the
given acceptance levels.

a 31-39mm.
b 18-22mm.
c None observed.
d 40-75mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-10 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 15-30mm.
b 5-8mm.
c None observed.
d 40-50mm.
e Accept.
f Reject.

16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 10-17mm.
b 1-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.

17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total and would you accept or reject your findings to the given
acceptance levels?

a 2-3 items observed.


b 1 item observed.
c None observed.
d 4 or more items observed.
e Accept.
f Reject.

18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?

a Individual pore diameter between 1-2mm.


b Individual pore diameter between 2-3mm.
c None observed.
d Individual pore diameter greater than 3mm.
e Accept.
f Reject.

19 Burn-through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?

a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-11 Copyright © TWI Ltd
20 With refrence to cluster porosity which answer best matches your assessment and
would you accept or reject your findings to the given acceptance levels.

a 20-30mm2.
b 31-40mm2.
c None observed.
d 12-18mm2.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-12 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-13 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-14 Copyright © TWI Ltd
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Plate Butt Weld 5

Answers to be indicated on the Candidate Answer Template.

Weld Face

1 Excess weld metal height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a Equal to or less than 0mm.


b 1-4mm.
c 5-6mm.
d 7-8mm.
e Accept.
f Reject.

2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a None observed.
b 16-29mm.
c 1-15mm.
d 40-50mm.
e Accept.
f Reject.

3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 60-70mm.
b 20-30mm.
c None observed.
d 5-12mm.
e Accept.
f Reject.

4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?

a 60-70mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-15 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?

a 1-15mm2.
b Greater than 100mm2.
c None observed.
d The area is between 70-90mm2.
e Accept.
f Reject.

6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?

a 2-3mm transverse crack.


b 15mm longitudinal crack.
c None observed.
d 9-14mm longitudinal crack.
e Accept.
f Reject.

7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 40-60mm.
b 20-39mm.
c None observed.
d 5-10mm.
e Accept.
f Reject.

8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?

a 3.
b 4.
c None observed.
d 1.
e Accept.
f Reject.

9 Sharp areas of mechanical damage (excluding hard stamping and pop marks):
Which answer best matches your assessment of the total number of areas and would
you accept or reject your findings to the given acceptance levels.

a 4.
b 1-2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-16 Copyright © TWI Ltd
Weld Root

10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?

a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.

11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a 2-3mm.
b 0.5-1.5mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.

12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 30-40mm.
b 20-25mm.
c None observed.
d 1-10mm.
e Accept.
f Reject.

13 Lack of root fusion: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 28-40mm.
b 1-10mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.

14 Root concavity or shrinkage: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels.

a 31-39mm.
b 18-25mm.
c None observed.
d 40-75mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-17 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 15-30mm.
b 5-8mm.
c None observed.
d 1-2mm.
e Accept.
f Reject.

16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 10-17mm.
b 1-4mm.
c None observed.
d 5-8mm.
e Accept
f Reject.

17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the total
number of items and would you accept or reject your findings to the given
acceptance levels?

a 2 items observed.
b 1 item observed.
c None observed.
d 3 or more items observed.
e Accept.
f Reject.

18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?

a Individual pore diameter between 1-2mm.


b Individual pore diameter between 0-0.5mm.
c None observed.
d Individual pore diameter greater than 3mm.
e Accept.
f Reject.

19 Burn-through in the root area: Which answer best matches your assessment of the
total number of areas and would you accept or reject your findings to the given
acceptance levels?

a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-18 Copyright © TWI Ltd
20 Angular distortion: Which answer best matches your assessment and would you
accept or reject your findings to the given acceptance levels (measure from the weld
centreline to the plate edge).

a 2-4mm.
b 6-8mm.
c None observed.
d 0.5-1mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-19 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-20 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-21 Copyright © TWI Ltd
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
Acceptance levels
Acceptance levels plate and pipe
Defect type macro only
number
Table

Remarks Maximum allowance Remarks

At no point shall the excess weld


metal fall below the outside Excess weld metal will not exceed H = 2mm
Excess weld
1 surface of the parent material. in any area on the parent material, showing As for plate and pipe
metal
All weld runs shall blend smooth transition at weld toes.
smoothly.
Slag inclusions are defined as
non-metallic inclusions trapped The length of the slag inclusion shall not
Slag/silica Slag and silica not
2 in the weld metal or between exceed 50mm continuous or intermittent.
inclusions permitted
the weld metal and the parent Accumulative totals shall not exceed 50mm
material.
No sharp indications Smooth blend required.
Undercut is defined as a grove
The length of any undercut shall not exceed
melted into the parent metal,
50mm continuous or intermittent. No sharp indications
3 Undercut at the toes of the weld excess
Accumulative totals shall not exceed 50mm. Smooth blend required
metal, root or adjacent weld
Max D = 1mm for the cap weld metal.
metal.
Root undercut not permitted.
Trapped gas, in weld metal, Individual pores ≤ 1.5 max.
Cluster porosity not
Porosity or elongated, individual pores, Cluster porosity maximum 502mm total area.
4 permitted. Individual
Gas Cavities cluster porosity, piping or Elongated, piping or wormholes
pores acceptable.
wormhole porosity. 15mm max. L continuous or intermittent.

Cracks or Transverse, longitudinal, star or


5 Not permitted Not permitted
Laminations crater cracks.

Incomplete fusion between Surface breaking lack of side wall fusion,


Lack of fusion the weld metal and base lack of inter-run fusion continuous or
6 Laps material, incomplete fusion intermittent not to exceed 15mm. Not permitted
Cold lap between weld metal. Accumulative totals not to exceed 15mm
(lack of inter-run fusion) over a 300mm length of weld.
Damage to the parent material
or weld metal, from an
unintentional touch down of the
7 Arc strikes Not permitted Not permitted
electrode or arcing from poor
connections in the welding
circuit.
No stray tack welds permitted
Damage to the parent material
Parent material must be smoothly blended
Mechanical or weld metal, internal or
8 General corrosion permitted. Max. D = Not permitted
damage external resulting from
1.5mm.
any activities.
Only 1 location allowed
Mismatch between the
9 Misalignment Max H = 1.5mm As for plate and pipe
welded or unwelded joint.

Excess weld metal, above the


10 Penetration base material in the root of the Max H ≤ 3mm As for plate and pipe
joint.
The absence of weld metal in
Lack of root
11 the root area, two root faces Not permitted Not permitted
penetration
showing.

Lack of root Inadequate cross penetration of Lack of root fusion, not to exceed 50mm total
12 Not permitted
fusion (one) root face. continuous or accumulative.

Excessive penetration, collapse


13 Burn through Not permitted Not permitted
of the weld root
Angular Distortion due to weld
14 5mm max. Plate only Accept
distortion contraction
Weld metal below the surface of 50mm maximum length
15 Root concavity Accept
both parent metals 3mm maximum depth

WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-22 Copyright © TWI Ltd
Practical Sessions Objective

When these presentation have been completed


you will have a greater understanding of the
examination requirement and how to identify
and plot weld defects around real life welds and
the classroom specimens on which you will be
Practical Plate Inspection examined.

Copyright © TWI Ltd Copyright © TWI Ltd

Example of Weld Face Example of Plate Root


EXAMPLE PLATE REPORT
Candidates Name……………………………….. Specification……………………………..
MEASURE

Candidates signature…………………………… Welding process………………………..


A B
Welding Position………………………..
MEASURE

Root
WELD FACE concavity Lack of root
2mm deep Fusion
FROM

A Undercut
B 23
Gas pore 10 24
Lack of sidewall smooth 20
7
FROM

fusion 1.5 Ø 1.5 max


87 230 236 30
22
THIS

12 50
THIS

8
Incomplete root
51 8 15 40 Arc
penetration
DATUM

3 Strike
Slag
DATUM

Centreline 24
inclusion
crack 1
EDGE
EDGE

NOTES: Penetration Height = Toe Blend = Weld Width =


NOTES: Excess Weld Metal = Linear Misalignment = Toe Blend = Weld Width =

Copyright © TWI Ltd Copyright © TWI Ltd

Plate Inspection Examination

2. Compare to acceptance standard.

1. Read the Questions and compare


Any Questions
with your thumb print.

3. Mark the answer in the OMR grid


in pencil and accept or reject
accordingly. When you are sure
about your answer mark the OMR
grid in BLACK PEN.
?
Copyright © TWI Ltd Copyright © TWI Ltd

A2-1
Appendix 3

Pipe Reports and Questions


CSWIP 3.1 Training Questions for Pipe Butt Weld 3

Answers to be indicated on the Candidate Answer Template.

Weld Face

1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?

a Equal to or less than 0mm.


b 1-4mm.
c 4-5mm.
d 7-8mm.
e Accept.
f Reject.

2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a None observed.
b 65-80mm.
c 10-25mm.
d 100-120mm.
e Accept.
f Reject.

3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 60-70mm.
b 20-30mm.
c None observed.
d 5-12mm.
e Accept.
f Reject.

4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?

a 50mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-1 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?

a 0-5mm2.
b Greater than 100mm2.
c None observed.
d 70-90mm2.
e Accept.
f Reject.

6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?

a 2-3mm transverse crack.


b 15mm longitudinal crack.
c None observed.
d 9-14mm longitudinal crack.
e Accept.
f Reject.

7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 68-80mm.
b 45-60mm.
c None observed.
d 30-40mm.
e Accept.
f Reject.

8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?

a 3.
b 4.
c None observed.
d 1.
e Accept.
f Reject.

9 Sharp indications of mechanical damage (excluding hard stamping and pop marks):
Which answer best matches your assessment of the total number of areas and would
you accept or reject your findings to the given acceptance levels?

a More than 2.
b 1.
c None observed.
d 2.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-2 Copyright © TWI Ltd
Weld Root

10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?

a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.

11 Root penetration height (Highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a 3-5mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.

12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 40-60mm.
b 20-35mm.
c None observed.
d 0-10mm.
e Accept.
f Reject.

13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 28-35mm.
b 0-15mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.

14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total length and would you accept or reject your findings to the
given acceptance levels.

a 31-39mm.
b 8-16mm.
c None observed.
d 40-60mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-3 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 15-30mm.
b 5-8mm.
c None observed.
d 0-2mm.
e Accept.
f Reject.

16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 10-17mm.
b 0-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.

17 Sharp areas of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total and would you accept or reject your findings to the given
acceptance levels?

a 2-3 items observed.


b 1 item observed.
c None observed.
d 4-5 items observed.
e Accept.
f Reject.

18 Porosity in the weld root area: Which of the following answers best matches your
assessment of the accumulative total area and would you accept or reject your
findings to the given acceptance levels?

a Individual pore diameter between 1-2mm.


b Individual pore diameter between 2-3mm.
c None observed.
d Individual pore diameter greater than 3mm.
e Accept.
f Reject.

19 Burn through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?

a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-4 Copyright © TWI Ltd
20 Porosity: Which answer best matches your assessment and would you accept or
reject your findings to the given acceptance levels (measure from the weld centreline
to the plate edge)?

a 30-50mm2.
b 60-80mm2.
c None observed.
d 10-20mm2.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-5 Copyright © TWI Ltd
Visual Inspection Pipe Report

Name [Block capitals]

Signature Pipe Ident#

Code/Specification used Welding Process Joint type

Welding position OutsideØ and Thickness Date

Weld face

A B C

Notes:
Excess weld metal height = Misalignment = Weld width = Toe blend =

C D A

Notes:
Excess weld metal height = Misalignment = Toe blend = Weld width =

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-6 Copyright © TWI Ltd
Pipe Root Face

A B C

Notes:
Excess penetration height = Toe blend =

C D A

Notes: Visual Inspection Pipe Report


Excess penetration height = Toe blend =

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-7 Copyright © TWI Ltd
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Pipe Butt Weld 4

Answers to be indicated on the Candidate Answer Template.

Weld Face

1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?

a Equal to or less than 0mm.


b 3-4mm.
c 5-6mm.
d 7-8mm.
e Accept.
f Reject.

2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a None observed.
b 80-100mm.
c 135-150mm.
d 110-130mm.
e Accept.
f Reject.

3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 60-70mm.
b 20-50mm.
c None observed.
d 2-6mm.
e Accept.
f Reject.

4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?

a 20-30mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-8 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?

a 35-45mm2.
b Greater than 55-80mm2.
c None observed.
d 20-30mm2.
e Accept.
f Reject.

6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?

a 2-3mm transverse crack.


b 15mm longitudinal crack.
c None observed.
d 9-14mm longitudinal crack.
e Accept.
f Reject.

7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 110-130mm.
b 95-105mm.
c None observed.
d 65-85mm.
e Accept.
f Reject.

8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?

a 2.
b 3.
c None observed.
d 1.
e Accept.
f Reject.

9 Sharp areas of mechanical damage (excluding hard stamping and pop marks): Which
answer best matches your assessment of the total number of areas and would you
accept or reject your findings to the given acceptance levels.

a 4.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-9 Copyright © TWI Ltd
Weld Root

10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?

a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject

11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a 3-5mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.

12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 35-40mm.
b 20-25mm.
c None observed.
d 0-10mm.
e Accept.
f Reject.

13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 28-35mm.
b 0-10mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.

14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total and would you accept or reject your findings to the given
acceptance levels?

a 8-12mm.
b 18-22mm.
c None observed.
d 20-40mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-10 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total l and would you accept or reject your findings to the given acceptance levels?

a 15-25mm.
b 35-45mm.
c None observed.
d 50-60mm.
e Accept.
f Reject.

16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 10-17mm.
b 0-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.

17 Sharp areas of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total number of items and would you accept or reject your findings to
the given acceptance levels?

a 2-3.
b 1 item.
c None observed.
d More than 4 items.
e Accept.
f Reject.

18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?

a Individual pore diameter between 1-2mm.


b Individual pore diameter between 2-3mm.
c None observed.
d Individual pore diameter greater than 3mm.
e Accept.
f Reject.

19 Burn through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?

a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-11 Copyright © TWI Ltd
20 Cluster porosity: Which answer best matches your assessment and would you accept
or reject your findings to the given acceptance levels. (measure from the weld
centreline to the plate edge)?

a 3-5mm2.
b 6-8mm2.
c None observed.
d 1-2mm2.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-12 Copyright © TWI Ltd
Visual Inspection Pipe Report

Name [Block capitals]

Signature Pipe Ident#

Code/Specification used Welding Process Joint type

Welding position OutsideØ and Thickness Date

Weld face

A B C

Notes:
Excess weld metal height = Misalignment = Weld width = Toe blend =

C D A

Notes:
Excess weld metal height = Misalignment = Toe blend = Weld width =

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-13 Copyright © TWI Ltd
Pipe Root Face

A B C

Notes:
Excess penetration height = Toe blend =

C D A

Notes: Visual Inspection Pipe Report


Excess penetration height = Toe blend =

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-14 Copyright © TWI Ltd
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Pipe Butt Weld 5

Answers to be indicated on the Candidate Answer Template

Weld Face

1 Excess weld metal height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a Equal to or less than 0mm.


b 3-4mm.
c 5-6mm.
d 7-8mm.
e Accept.
f Reject.

2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a None observed.
b 40-55mm.
c 30-40mm.
d 60-70mm.
e Accept.
f Reject.

3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 60-70mm.
b 20-50mm.
c None observed.
d 5-12mm.
e Accept.
f Reject.

4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?

a Smooth intermittent.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-15 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?

a 0-20mm2.
b Greater than 30-50mm2.
c None observed.
d 60-70mm2.
e Accept.
f Reject.

6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?

a 2-3mm transverse crack.


b 15mm longitudinal crack.
c None observed.
d 9-14mm longitudinal crack.
e Accept.
f Reject.

7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?

a 30-40mm.
b 45-55mm.
c None observed.
d 60-70mm.
e Accept.
f Reject.

8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?

a 2.
b 4.
c None observed.
d 1.
e Accept.
f Reject.

9 Sharp indications of mechanical damage (excluding hard stamping and pop marks):
Which answer best matches your assessment of the total number of areas and would
you accept or reject your findings to the given acceptance levels?

a 4.
b 1-2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-16 Copyright © TWI Ltd
Weld Root

10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?

a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.

11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?

a 3-5mm.
b 1-2mm.
c None .
d Greater than 5mm.
e Accept.
f Reject.

12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?

a 30-40mm.
b 21-29mm.
c None observed.
d 41-50mm.
e Accept.
f Reject.

13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 28-35mm.
b 0-10mm.
c None observed.
d 15-26mm.
e Accept.
f Reject.

14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total and would you accept or reject your findings to the given
acceptance levels?

a 31-39mm.
b 18-22mm.
c None observed.
d 40-60mm.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-17 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total and would you accept or reject your findings to the given acceptance levels?

a 35-45mm.
b 20-30mm.
c None observed.
d 50-60mm.
e Accept.
f Reject.

16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?

a 10-17mm.
b 0-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.

17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total number of items and would you accept or reject your findings to
the given acceptance levels?

a 2-3.
b 1.
c None observed.
d 4-5.
e Accept.
f Reject.

18 Porosity in the weld root area: Which of the following answers best matches your
assessment of the accumulative total area and would you accept or reject your
findings to the given acceptance levels?

a Individual pore diameter between 1-2mm.


b Individual pore diameter between 2-3mm.
c None observed.
d Individual pore diameter greater than 3mm.
e Accept.
f Reject.

19 Burn through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?

a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-18 Copyright © TWI Ltd
20 Cluster porosity: Which answer best matches your assessment and would you accept
or reject your findings to the given acceptance levels (measure from the weld
centreline to the plate edge)?

a 30-50mm2.
b 60-80mm2.
c None observed.
d 12-22mm2.
e Accept.
f Reject.

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-19 Copyright © TWI Ltd
Visual Inspection Pipe Report

Name [Block capitals]

Signature Pipe Ident#

Code/Specification used Welding Process Joint type

Welding position OutsideØ and Thickness Date

Weld face

A B C

Notes:
Excess weld metal height = Misalignment = Weld width = Toe blend =

C D A

Notes:
Excess weld metal height = Misalignment = Toe blend = Weld width =

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-20 Copyright © TWI Ltd
Pipe Root Face

A B C

Notes:
Excess penetration height = Toe blend =

C D A

Notes:
Excess penetration height = Toe blend =

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-21 Copyright © TWI Ltd
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST  RETEST  10 YR  10 YR  CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:

1 1 31
I agree with the terms and conditions of  Tick  Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
Table numbers

Acceptance levels
Defect type Acceptance levels plate and pipe macro only

Remarks Maximum allowance Remarks

At no point shall the excess


weld metal fall below the Excess weld metal will not exceed H = 2mm
Excess weld As for plate and
1 outside surface of the parent in any area on the parent material, showing
metal pipe
material. All weld runs shall smooth transition at weld toes.
blend smoothly.
Slag inclusions are defined as
non-metallic inclusions trapped The length of the slag inclusion shall not
Slag/silica Slag and silica not
2 in the weld metal or between exceed 50mm continuous or intermittent.
inclusions permitted
the weld metal and the parent Accumulative totals shall not exceed 50mm
material.
No sharp indications Smooth blend required.
Undercut is defined as a grove
The length of any undercut shall not exceed No sharp
melted into the parent metal,
50mm continuous or intermittent. indications
3 Undercut at the toes of the weld excess
Accumulative totals shall not exceed 50mm. Smooth blend
metal, root or adjacent weld
Max D = 1mm for the cap weld metal. required
metal.
Root undercut not permitted.
Trapped gas, in weld metal, Individual pores ≤ 1.5 max. Cluster porosity not
Porosity or elongated, individual pores, Cluster porosity maximum 502mm total area. permitted.
4
Gas Cavities cluster porosity, piping or Elongated, piping or wormholes Individual pores
wormhole porosity. 15mm max. L continuous or intermittent. acceptable.

Cracks or Transverse, longitudinal, star or


5 Not permitted Not permitted
Laminations crater cracks.

Incomplete fusion between Surface breaking lack of side wall fusion,


Lack of fusion the weld metal and base lack of inter-run fusion continuous or
6 Laps material, incomplete fusion intermittent not to exceed 15mm. Not permitted
Cold lap between weld metal. Accumulative totals not to exceed 15mm
(lack of inter-run fusion) over a 300mm length of weld.
Damage to the parent material
or weld metal, from an
unintentional touchdown of the
7 Arc strikes Not permitted Not permitted
electrode or arcing from poor
connections in the welding
circuit.
Damage to the parent material No stray tack welds permitted
Mechanical or weld metal, internal or Parent material must be smoothly blended
8 Not permitted
damage external resulting from General corrosion permitted. Max. D =
any activities. 1.5mm. Only 1 location allowed
Mismatch between the As for plate and
9 Misalignment Max H = 1.5mm
welded or unwelded joint. pipe

Excess weld metal, above the


As for plate and
10 Penetration base material in the root of the Max H ≤ 3mm
pipe
joint.

The absence of weld metal in


Lack of root
11 the root area, two root faces Not permitted Not permitted
penetration
showing.

Lack of root Inadequate cross penetration of Lack of root fusion, not to exceed 50mm total
12 Not permitted
fusion (one) root face. continuous or accumulative.

Excessive penetration, collapse


13 Burn through Not permitted Not permitted
of the weld root

Angular Distortion due to weld


14 5mm max. Plate only Accept
distortion contraction
Weld metal below the surface of 50mm maximum length
15 Root concavity Accept
both parent metals 3mm maximum depth

WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-22 Copyright © TWI Ltd
Practical Sessions Objective

When these presentation have been completed


you will have a greater understanding of the
examination requirement and how to identify
and plot weld defects around real life welds and
the classroom specimens on which you will be
Practical Pipe Inspection examined.

Copyright © TWI Ltd Copyright © TWI Ltd

Pipe Inspection Hi-Low and Root Gap Measurements


1

Root gap
dimension
HI-LO Single Purpose Welding Gauge

Internal
alignment

Copyright © TWI Ltd Copyright © TWI Ltd

Pipe Inspection Examination


Pipe Inspection Examination Pipe Inspection Examination
EXAMPLE PIPE REPORT

 After you have observed an imperfection and


Name: [Block capitals] ….............................. Signature: ……………….
Date…………………….
Code/Specification used: …………………… Welding process: ……………… Joint type: …………….
determined its type, you must be able to take Welding position: …………………. Outside Dia & thickness ……………
WELD FACE
Date ……………………

measurements and complete the thumb print A Lack of side B Arc Strike C
report sketch. 140
wall fusion
8 40
Under fill
12
98

 The first thumb print report sketch should be in


90 10 180 60 5
the form of a repair map of the weld. (ie all 20 15 46
Slag
observations are Identified sized and located). Lack of side Undercut Under fill
inclusion
wall fusion >1.0 mm
NOTES:
Excess Weld Metal Height = Misalignment = Weld Width = Toe Blend =
 The thumb print report sketch used in CSWIP Lack of side wall fusion
Arc Strike
C D A
exam will look like the following example. Slag / incomplete fill
12 15 3 8 2
0 8 5

 The thumb print is to used in conjunction with


the multiple choice questions during the
examination .
NOTES:
Excess Weld Metal Height = Misalignment = Weld Width = Toe Blend =

Copyright © TWI Ltd Copyright © TWI Ltd

A3-1
Pipe Inspection Examination Pipe Inspection Examination
PIPE ROOT FACE
1. Read the Questions and compare 2. Compare to acceptance standard.
A Lack of B C
root fusion Burn with your thumb print.
140 through
8 40 6

2 1 90 1 180 46 5
6
0 5 0
0
Lack of Undercut Excess Poor stop
root >1.0 mm penetration start
penetratio 5mm
n
NOTES:
Excess Penetration Height = Toe Blend =
Lack of
C D root fusion
A
38 8
3. Mark the answer in the OMR grid
in pencil and accept or reject
12 accordingly. When you are sure
0 120
about your answer mark the OMR
Smooth Undercut grid in BLACK PEN.
<1.0mm

NOTES: Excess Penetration Height = Toe Blend =

Copyright © TWI Ltd Copyright © TWI Ltd

Any Questions

?
Copyright © TWI Ltd

A3-2