Professional Documents
Culture Documents
Weld Face
1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?
2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a None observed.
b 40-60mm.
c 1-30mm.
d 75-100mm.
e Accept.
f Reject.
3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 60-70mm.
b 20-30mm.
c None observed.
d 5-18mm.
e Accept.
f Reject.
4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?
a 50mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-1 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?
6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?
7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 70-90mm.
b 30-60mm.
c None observed.
d 91-100mm.
e Accept.
f Reject.
8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?
a 3 total.
b 4 total.
c None observed.
d 1 total.
e Accept.
f Reject.
9 Sharp areas of mechanical damage (excluding hard stamping and pop marks): Which
answer best matches your assessment of the total number of areas and would you
accept or reject your findings to the given acceptance levels.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-2 Copyright © TWI Ltd
Weld Root
10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?
a 2-3mm.
b 4-5mm.
c 0-1.
d Greater than 5mm.
e Accept.
f Reject.
11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
a 2-3mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.
12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 40-55mm.
b 25-35mm.
c None observed.
d 1-10mm.
e Accept.
f Reject.
13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 30-45mm.
b 1-15mm.
c None observed.
d 16-29mm.
e Accept.
f Reject.
14 Root concavity or shrinkage: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels.
a 31-39mm.
b 18-22mm.
c None observed.
d 40-60mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-3 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 40-60mm.
b 5-8mm.
c None observed.
d 2-4mm.
e Accept.
f Reject.
16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 10-17mm.
b 1-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.
17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the total
number of items and would you accept or reject your findings to the given
acceptance levels?
a 2 observed.
b 1 item observed.
c None observed.
d 3 or more items observed.
e Accept.
f Reject.
18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?
19 Burn-through in the root area: Which answer best matches your assessment of the
total number of areas and would you accept or reject your findings to the given
acceptance levels?
a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-4 Copyright © TWI Ltd
20 Angular distortion: Which answer best matches your assessment and would you
accept or reject your findings to the given acceptance levels (measure from the weld
centreline to the plate edge).
a 3-4mm.
b 5-6mm.
c None observed.
d 1-2mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-5 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-6 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-7 Copyright © TWI Ltd
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Plate Butt Weld 4
Weld Face
1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?
2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a None observed.
b 30-50mm.
c 1-25mm.
d 100-120mm.
e Accept.
f Reject.
3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 12-18mm.
b 8-10mm.
c None observed.
d 2-6mm.
e Accept.
f Reject.
4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?
a 10-20mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-8 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?
6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?
7 Lack of fusion: Which answer best matches your assessment of the total
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 30-39mm.
b 40-55mm.
c None observed.
d 5-10mm.
e Accept.
f Reject.
8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?
a 2.
b 3.
c None observed.
d 1.
e Accept.
f Reject.
9 Sharp areas of mechanical damage (excluding hard stamping and pop marks): Which
answer best matches your assessment of the total number of areas and would you
accept or reject your findings to the given acceptance levels.
a 4 areas.
b 1-2 areas.
c None observed.
d 3 areas.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-9 Copyright © TWI Ltd
Weld Root
10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?
a 0.5-1mm.
b 1.5-2mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.
11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
a 3-5mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.
12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 35-40mm.
b 20-25mm.
c None observed.
d 1-10mm.
e Accept.
f Reject.
13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 28-35mm.
b 1-10mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.
14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total length and would you accept or reject your findings to the
given acceptance levels.
a 31-39mm.
b 18-22mm.
c None observed.
d 40-75mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-10 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 15-30mm.
b 5-8mm.
c None observed.
d 40-50mm.
e Accept.
f Reject.
16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 10-17mm.
b 1-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.
17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total and would you accept or reject your findings to the given
acceptance levels?
18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?
19 Burn-through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?
a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-11 Copyright © TWI Ltd
20 With refrence to cluster porosity which answer best matches your assessment and
would you accept or reject your findings to the given acceptance levels.
a 20-30mm2.
b 31-40mm2.
c None observed.
d 12-18mm2.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-12 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-13 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-14 Copyright © TWI Ltd
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Plate Butt Weld 5
Weld Face
1 Excess weld metal height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a None observed.
b 16-29mm.
c 1-15mm.
d 40-50mm.
e Accept.
f Reject.
3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 60-70mm.
b 20-30mm.
c None observed.
d 5-12mm.
e Accept.
f Reject.
4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?
a 60-70mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-15 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?
a 1-15mm2.
b Greater than 100mm2.
c None observed.
d The area is between 70-90mm2.
e Accept.
f Reject.
6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?
7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 40-60mm.
b 20-39mm.
c None observed.
d 5-10mm.
e Accept.
f Reject.
8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?
a 3.
b 4.
c None observed.
d 1.
e Accept.
f Reject.
9 Sharp areas of mechanical damage (excluding hard stamping and pop marks):
Which answer best matches your assessment of the total number of areas and would
you accept or reject your findings to the given acceptance levels.
a 4.
b 1-2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-16 Copyright © TWI Ltd
Weld Root
10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?
a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.
11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
a 2-3mm.
b 0.5-1.5mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.
12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 30-40mm.
b 20-25mm.
c None observed.
d 1-10mm.
e Accept.
f Reject.
13 Lack of root fusion: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 28-40mm.
b 1-10mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.
14 Root concavity or shrinkage: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels.
a 31-39mm.
b 18-25mm.
c None observed.
d 40-75mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-17 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 15-30mm.
b 5-8mm.
c None observed.
d 1-2mm.
e Accept.
f Reject.
16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 10-17mm.
b 1-4mm.
c None observed.
d 5-8mm.
e Accept
f Reject.
17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the total
number of items and would you accept or reject your findings to the given
acceptance levels?
a 2 items observed.
b 1 item observed.
c None observed.
d 3 or more items observed.
e Accept.
f Reject.
18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?
19 Burn-through in the root area: Which answer best matches your assessment of the
total number of areas and would you accept or reject your findings to the given
acceptance levels?
a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-18 Copyright © TWI Ltd
20 Angular distortion: Which answer best matches your assessment and would you
accept or reject your findings to the given acceptance levels (measure from the weld
centreline to the plate edge).
a 2-4mm.
b 6-8mm.
c None observed.
d 0.5-1mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-19 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-20 Copyright © TWI Ltd
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-21 Copyright © TWI Ltd
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
Acceptance levels
Acceptance levels plate and pipe
Defect type macro only
number
Table
Lack of root Inadequate cross penetration of Lack of root fusion, not to exceed 50mm total
12 Not permitted
fusion (one) root face. continuous or accumulative.
WIS5-90516b
Appendix 2 – Plate Reports and Questions A2-22 Copyright © TWI Ltd
Practical Sessions Objective
Root
WELD FACE concavity Lack of root
2mm deep Fusion
FROM
A Undercut
B 23
Gas pore 10 24
Lack of sidewall smooth 20
7
FROM
12 50
THIS
8
Incomplete root
51 8 15 40 Arc
penetration
DATUM
3 Strike
Slag
DATUM
Centreline 24
inclusion
crack 1
EDGE
EDGE
A2-1
Appendix 3
Weld Face
1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?
2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a None observed.
b 65-80mm.
c 10-25mm.
d 100-120mm.
e Accept.
f Reject.
3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 60-70mm.
b 20-30mm.
c None observed.
d 5-12mm.
e Accept.
f Reject.
4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?
a 50mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-1 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?
a 0-5mm2.
b Greater than 100mm2.
c None observed.
d 70-90mm2.
e Accept.
f Reject.
6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?
7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 68-80mm.
b 45-60mm.
c None observed.
d 30-40mm.
e Accept.
f Reject.
8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?
a 3.
b 4.
c None observed.
d 1.
e Accept.
f Reject.
9 Sharp indications of mechanical damage (excluding hard stamping and pop marks):
Which answer best matches your assessment of the total number of areas and would
you accept or reject your findings to the given acceptance levels?
a More than 2.
b 1.
c None observed.
d 2.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-2 Copyright © TWI Ltd
Weld Root
10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?
a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.
11 Root penetration height (Highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
a 3-5mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.
12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 40-60mm.
b 20-35mm.
c None observed.
d 0-10mm.
e Accept.
f Reject.
13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 28-35mm.
b 0-15mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.
14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total length and would you accept or reject your findings to the
given acceptance levels.
a 31-39mm.
b 8-16mm.
c None observed.
d 40-60mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-3 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 15-30mm.
b 5-8mm.
c None observed.
d 0-2mm.
e Accept.
f Reject.
16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 10-17mm.
b 0-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.
17 Sharp areas of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total and would you accept or reject your findings to the given
acceptance levels?
18 Porosity in the weld root area: Which of the following answers best matches your
assessment of the accumulative total area and would you accept or reject your
findings to the given acceptance levels?
19 Burn through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?
a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-4 Copyright © TWI Ltd
20 Porosity: Which answer best matches your assessment and would you accept or
reject your findings to the given acceptance levels (measure from the weld centreline
to the plate edge)?
a 30-50mm2.
b 60-80mm2.
c None observed.
d 10-20mm2.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-5 Copyright © TWI Ltd
Visual Inspection Pipe Report
Weld face
A B C
Notes:
Excess weld metal height = Misalignment = Weld width = Toe blend =
C D A
Notes:
Excess weld metal height = Misalignment = Toe blend = Weld width =
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-6 Copyright © TWI Ltd
Pipe Root Face
A B C
Notes:
Excess penetration height = Toe blend =
C D A
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-7 Copyright © TWI Ltd
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Pipe Butt Weld 4
Weld Face
1 Maximum excess weld metal height (highest individual point measured): Which
answer best matches your assessment and would you accept or reject your findings
to the given acceptance levels?
2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a None observed.
b 80-100mm.
c 135-150mm.
d 110-130mm.
e Accept.
f Reject.
3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 60-70mm.
b 20-50mm.
c None observed.
d 2-6mm.
e Accept.
f Reject.
4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?
a 20-30mm in length.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-8 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?
a 35-45mm2.
b Greater than 55-80mm2.
c None observed.
d 20-30mm2.
e Accept.
f Reject.
6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?
7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 110-130mm.
b 95-105mm.
c None observed.
d 65-85mm.
e Accept.
f Reject.
8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?
a 2.
b 3.
c None observed.
d 1.
e Accept.
f Reject.
9 Sharp areas of mechanical damage (excluding hard stamping and pop marks): Which
answer best matches your assessment of the total number of areas and would you
accept or reject your findings to the given acceptance levels.
a 4.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-9 Copyright © TWI Ltd
Weld Root
10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?
a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject
11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
a 3-5mm.
b 1-2mm.
c None.
d Greater than 5mm.
e Accept.
f Reject.
12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 35-40mm.
b 20-25mm.
c None observed.
d 0-10mm.
e Accept.
f Reject.
13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 28-35mm.
b 0-10mm.
c None observed.
d 15-23mm.
e Accept.
f Reject.
14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total and would you accept or reject your findings to the given
acceptance levels?
a 8-12mm.
b 18-22mm.
c None observed.
d 20-40mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-10 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total l and would you accept or reject your findings to the given acceptance levels?
a 15-25mm.
b 35-45mm.
c None observed.
d 50-60mm.
e Accept.
f Reject.
16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 10-17mm.
b 0-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.
17 Sharp areas of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total number of items and would you accept or reject your findings to
the given acceptance levels?
a 2-3.
b 1 item.
c None observed.
d More than 4 items.
e Accept.
f Reject.
18 Porosity in the weld root area: Which answer best matches your assessment of the
accumulative total area and would you accept or reject your findings to the given
acceptance levels?
19 Burn through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?
a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-11 Copyright © TWI Ltd
20 Cluster porosity: Which answer best matches your assessment and would you accept
or reject your findings to the given acceptance levels. (measure from the weld
centreline to the plate edge)?
a 3-5mm2.
b 6-8mm2.
c None observed.
d 1-2mm2.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-12 Copyright © TWI Ltd
Visual Inspection Pipe Report
Weld face
A B C
Notes:
Excess weld metal height = Misalignment = Weld width = Toe blend =
C D A
Notes:
Excess weld metal height = Misalignment = Toe blend = Weld width =
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-13 Copyright © TWI Ltd
Pipe Root Face
A B C
Notes:
Excess penetration height = Toe blend =
C D A
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-14 Copyright © TWI Ltd
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
CSWIP 3.1 Training Questions for Pipe Butt Weld 5
Weld Face
1 Excess weld metal height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
2 Incomplete fill: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a None observed.
b 40-55mm.
c 30-40mm.
d 60-70mm.
e Accept.
f Reject.
3 Slag inclusions: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 60-70mm.
b 20-50mm.
c None observed.
d 5-12mm.
e Accept.
f Reject.
4 Undercut: Which answer best matches your assessment of the imperfection and
would you accept or reject your findings to the given acceptance levels?
a Smooth intermittent.
b Sharp but less than 1mm deep.
c None observed.
d Sharp but more than 1mm deep.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-15 Copyright © TWI Ltd
5 Porosity in the weld: Which answer best matches your assessment of the total
accumulative area and would you accept or reject your findings to the given
acceptance levels?
a 0-20mm2.
b Greater than 30-50mm2.
c None observed.
d 60-70mm2.
e Accept.
f Reject.
6 Cracks: Which answer best matches your assessment of the total accumulative
length and would you accept or reject your findings to the given acceptance levels?
7 Lack of fusion: Which answer best matches your assessment of the total
accumulative length and would you accept or reject your findings to the given
acceptance levels?
a 30-40mm.
b 45-55mm.
c None observed.
d 60-70mm.
e Accept.
f Reject.
8 Arc strikes: Which answer best matches your assessment of the total number and
would you accept or reject your findings to the given acceptance levels?
a 2.
b 4.
c None observed.
d 1.
e Accept.
f Reject.
9 Sharp indications of mechanical damage (excluding hard stamping and pop marks):
Which answer best matches your assessment of the total number of areas and would
you accept or reject your findings to the given acceptance levels?
a 4.
b 1-2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-16 Copyright © TWI Ltd
Weld Root
10 Misalignment: Which answer best matches your assessment of the maximum value
and would you accept or reject your findings to the given acceptance levels?
a 1-2mm.
b 3-4mm.
c None observed.
d Greater than 5mm.
e Accept.
f Reject.
11 Root penetration height (highest individual point measured): Which answer best
matches your assessment and would you accept or reject your findings to the given
acceptance levels?
a 3-5mm.
b 1-2mm.
c None .
d Greater than 5mm.
e Accept.
f Reject.
12 Lack of root penetration: Which answer best matches your assessment of the
accumulative total length and would you accept or reject your findings to the given
acceptance levels?
a 30-40mm.
b 21-29mm.
c None observed.
d 41-50mm.
e Accept.
f Reject.
13 Lack of root fusion: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 28-35mm.
b 0-10mm.
c None observed.
d 15-26mm.
e Accept.
f Reject.
14 Root concavity or root shrinkage: Which answer best matches your assessment of
the accumulative total and would you accept or reject your findings to the given
acceptance levels?
a 31-39mm.
b 18-22mm.
c None observed.
d 40-60mm.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-17 Copyright © TWI Ltd
15 Root undercut: Which answer best matches your assessment of the accumulative
total and would you accept or reject your findings to the given acceptance levels?
a 35-45mm.
b 20-30mm.
c None observed.
d 50-60mm.
e Accept.
f Reject.
16 Cracks in the root: Which answer best matches your assessment of the accumulative
total length and would you accept or reject your findings to the given acceptance
levels?
a 10-17mm.
b 0-4mm.
c None observed.
d 5-8mm.
e Accept.
f Reject.
17 Sharp indications of mechanical damage in the root area weld and parent material
(excluding hard stamping): Which answer best matches your assessment of the
accumulative total number of items and would you accept or reject your findings to
the given acceptance levels?
a 2-3.
b 1.
c None observed.
d 4-5.
e Accept.
f Reject.
18 Porosity in the weld root area: Which of the following answers best matches your
assessment of the accumulative total area and would you accept or reject your
findings to the given acceptance levels?
19 Burn through in the root area: Which answer best matches your assessment of the
accumulative total number of areas and would you accept or reject your findings to
the given acceptance levels?
a 1.
b 2.
c None observed.
d 3.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-18 Copyright © TWI Ltd
20 Cluster porosity: Which answer best matches your assessment and would you accept
or reject your findings to the given acceptance levels (measure from the weld
centreline to the plate edge)?
a 30-50mm2.
b 60-80mm2.
c None observed.
d 12-22mm2.
e Accept.
f Reject.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-19 Copyright © TWI Ltd
Visual Inspection Pipe Report
Weld face
A B C
Notes:
Excess weld metal height = Misalignment = Weld width = Toe blend =
C D A
Notes:
Excess weld metal height = Misalignment = Toe blend = Weld width =
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-20 Copyright © TWI Ltd
Pipe Root Face
A B C
Notes:
Excess penetration height = Toe blend =
C D A
Notes:
Excess penetration height = Toe blend =
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-21 Copyright © TWI Ltd
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
RETEST RETEST 10 YR 10 YR CANDIDATE TO FILL ALL BOXES INDICATED IN BLUE
1 2 3 4 5 6 7 INITIAL
1 2 INITIAL RETEST
WI 3.1 EXAM _
O O O O O O O O O O O O
INVIGILATOR NAME: INVIGILATOR SIGNATURE:
VERSION _
O O O O O O O
EXAM DATE: EVENT CODE
GENERAL THEORY TECHNOLOGY THEORY
A B C D A B C D A B C D CANDIDATE NAME: CANDIDATE SIGNATURE:
1 1 31
I agree with the terms and conditions of Tick Date of Birth
2 2 32 this examination Box D D M M Y Y
3 3 33 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
MACRO A
_ _
O O O O O O O O O O O O O O O O O O O O A B C D E F
4 4 34 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 1
5 5 35 _
O O O O O O O O O O _
O O O O O O O O O O
_
O O O O O O O O O O _
O O O O O O O O O O 2
6 6 36 _
O O O O O O O O O O _
O O O O O O O O O O
3
7 7 37 BOOKING REFERENCE OFFICE USE ONLY CANDIDATE NUMBER FOR OFFICE USE ONLY
4
8 8 38
5
9 9 39
PLATE PIPE 6
10 10 40 A B C D E F A B C D E F
7
11 11 41 1 1
8
12 12 42 2 2
9
13 13 43 3 3
10
14 14 44 4 4
11
15 15 45 5 5
12
16 16 46 6 6
17 17 47 7 7
MACRO B
18 18 48 8 8 A B C D E F
19 19 49 9 9 1
20 20 50 10 10 2
21 21 51 11 11 3
22 22 52 12 12 4
23 23 53 13 13 5
24 24 54 14 14 6
25 25 55 15 15 7
26 26 56 16 16 8
27 27 57 17 17 9
28 28 58 18 18 10
29 29 59 19 19 11
30 30 60 20 20 12
Table numbers
Acceptance levels
Defect type Acceptance levels plate and pipe macro only
Lack of root Inadequate cross penetration of Lack of root fusion, not to exceed 50mm total
12 Not permitted
fusion (one) root face. continuous or accumulative.
WIS5-90516b
Appendix 3 Pipe Reports and Questions A3-22 Copyright © TWI Ltd
Practical Sessions Objective
Root gap
dimension
HI-LO Single Purpose Welding Gauge
Internal
alignment
measurements and complete the thumb print A Lack of side B Arc Strike C
report sketch. 140
wall fusion
8 40
Under fill
12
98
A3-1
Pipe Inspection Examination Pipe Inspection Examination
PIPE ROOT FACE
1. Read the Questions and compare 2. Compare to acceptance standard.
A Lack of B C
root fusion Burn with your thumb print.
140 through
8 40 6
2 1 90 1 180 46 5
6
0 5 0
0
Lack of Undercut Excess Poor stop
root >1.0 mm penetration start
penetratio 5mm
n
NOTES:
Excess Penetration Height = Toe Blend =
Lack of
C D root fusion
A
38 8
3. Mark the answer in the OMR grid
in pencil and accept or reject
12 accordingly. When you are sure
0 120
about your answer mark the OMR
Smooth Undercut grid in BLACK PEN.
<1.0mm
Any Questions
?
Copyright © TWI Ltd
A3-2