SIMATIC WinCC Open Architecture


Multilevel Wind SCADA Center V1.0

© Siemens AG 2014 All rights reserved. siemens.com/answers


Multilevel Wind SCADA Center
Table of content

• The idea behind the MWSC V1.0 3


• How you can use the MWSC V1.0 5
• What is inside the MWSC V1.0 9
• Configurations of the MWSC V1.0 19

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
SIMATIC WinCC Open Architecture, Multilevel Wind SCADA Center

The idea behind the MWSC V1.0

© Siemens AG 2014 All rights reserved. siemens.com/answers


The idea behind the MWSC V1.0

Basic system + 2 years of engineering Application


SIMATIC Multilevel
WinCC OA Wind
V3.12 SC AD A
Center

ØEngineering tool for SCADA


ØSCADA runtime system for MWSC V1.0
ØPlatform independent MWSC_CENTER_LIB_v1_0 MWSC_TURBINE_LIB_v1_0

ØIEC61850 client Control center library


Turbine library
Both libraries contain:
ØWinCC OA VIDEO
ü Mature panels – for a user friendly handling
ü Sophisticated scripts – gives access to a wide
© Siemens AG 2014 All rights reserved. range of functionality
2014-07-01 Petar Anic / VMM Wind
SIMATIC WinCC Open Architecture, Multilevel Wind SCADA Center

How you can use the MWSC V1.0

© Siemens AG 2014 All rights reserved. siemens.com/answers


Possible architectures supported by MWSC V1.0

Variation 1a Variation 1b Variation 1c Variation 1b:


Control room server is
CONTROL ROOM
SERVER connected to the turbine
Central Central Central
Control Control
room C Control PLCs via WinCC OA
room
control control control
room
level level level driver communication.
level level level
No server on the turbine
Multiple parks can be
connected
PARK SERVER
Standard driver

C Standard driver
communication Variation 1a:
Windpark
Park
communication Park
Windpark Park
Windpark Park server is connected
level level level
level level level to the turbine PLCs via
WinCC OA driver
communication.
No server on the turbine
T
Variation 1c:
Turbine
Turbine server is
Turbine
Turbine Turbine
Turbine Turbine
level level
level level
level
Driver
connected to the turbine
level
PLC via WinCC OA driver
communication
PLC

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Possible architectures supported by MWSC V1.0

Variation 2a Variation 2b Variation 2c Variation 2b:


Control room server is
CONTROL ROOM CONTROL ROOM
SERVER SERVER connected to the turbine
Central Central Central
Control
room
Control
room C Control
room C servers via integrated
control control control
level
level
level
level
level
level
WinCC OA Dist
communication
Multiple parks can be
PARK SERVER
connected
WinCC OA TCP/IP
PARK SERVER
WinCC OA TCP/IP communication
Variation 2a:
C Park communication
Park
Windpark Windpark Park
Windpark Park server is connected
level level
level level
level level to the turbine server via
WinCC OA TCP / IP
communication integrated WinCC OA
Dist communication
Variation 2c:
T T T Turbine server is
connected to the turbine
Turbine PLC via WinCC OA driver
Turbine
Turbine Turbine Turbine
Turbine
level level
level level communication
level Driver Driver
level Driver
Control room server and
park server do have a
parallel communication
PLC PLC PLC to each turbine server via
integrated WinCC OA
© Siemens AG 2014 All rights reserved. Dist communication
2014-07-01 Petar Anic / VMM Wind
How you can use the MWSC V1.0

M u l t i l e v e l W i n d S C A D A C e n t e r

Control room / Turbine


Windpark
C T
Variation 1: one part of the library is used (either C or T) Variation 2: both parts of the library are used (C and T)

Control room
C C C
level

Park level C C C

Turbine level T T T T

Variation 1a Variation 1b Variation 1c Variation 2a Variation 2b Variation 2c


© Siemens AG 2014 All rights reserved.
2014-07-01 Petar Anic / VMM Wind
SIMATIC WinCC Open Architecture, Multilevel Wind SCADA Center

What is inside the MWSC V1.0

© Siemens AG 2014 All rights reserved. siemens.com/answers


Multilevel Wind SCADA Center – Control center modules

PARK MODULE
C
MAPS MODULE CCTV MODULE

Control center library

ALARM MODULE
DETAIL MODULE TREND MODULE

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Park module

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Maps Module

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – CCTV module

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Detail module

CCTV MODULE

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Trend module

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Alarm module

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Control center Drag & Drop functionality

PARK DETAIL
MODULE MODULE

MAPS TREND
MODULE MODULE

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA Center – Turbine modules

CCTV MODULE
T

Turbine library

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
SIMATIC WinCC Open Architecture, Multilevel Wind SCADA Center

Configurations of the MWSC V1.0

© Siemens AG 2014 All rights reserved. siemens.com/answers


Assumptions

Technical assumptions:
Based on our experience the following number of tags/IO´s seems to be sufficient:
Total: max. 3,500 tags per turbine

Performance assumptions:
• 15 turbines per park
• The analog values are read every second

Total values per turbine:


Analogue values: 360 (230 analogue values + 130 counters)
Status / fault information: 1,570 (530 alerts, 2 x 230 warnings, 2 x 230 alerts, 120 DO)
Total IO amount: 3,500

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Proposed WinCC OA configurations – Variation 1a

Variation 1a WinCC OA license Possible Required MWSC library:


configuration: Options/Add-Ons:
Central
Control
room
control
level
level

PARK SERVER
• 1 WinCC OA server • Redundant park server

Park
Windpark
Standard driver
communication
53,000 I/O’ s configuration C
level • 6 WinCC OA UI client • Web Client(s)
level
• 1 Driver: (e.g.) • External database (Oracle)
• IEC61400 Control center library
• OPC
• S7
• Modbus
• …

Turbine
Turbine
level
level

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Proposed WinCC OA configurations – Variation 1b

Variation 1b WinCC OA license Possible Required MWSC library:


configuration: Options/Add-Ons:
CONTROL ROOM
SERVER
Central
Control
• 1 WinCC OA server • Redundant park server
room
control 53,000 I/O’ s configuration
level
level • 6 WinCC OA UI client • Web Client(s) C
• 1 Driver: (e.g.) • External database (Oracle)
• IEC61400 Control center library
Standard driver • OPC
communication
• S7
Park
Windpark • Modbus
level
level • …

Turbine
Turbine
level
level

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Proposed WinCC OA configurations – Variation 1c

Variation 1c WinCC OA license Possible Required MWSC library:


configuration: Options/Add-Ons:
Central
Control
control
room
level
level

Park
Windpark
level
level

• 1 WinCC OA server • Redundant park server


3,500 I/O’s configuration
• 1 WinCC OA UI client • Ultralight Client
Turbine
Turbine • Dist • External database (Oracle)
level
level Driver
• 1 Driver: (e.g.)
• IEC61400
T
• OPC
PLC • S7 Turbine library
• Modbus
• …
© Siemens AG 2014 All rights reserved.
2014-07-01 Petar Anic / VMM Wind
Proposed WinCC OA configurations – Variation 2a

Variation 2a WinCC OA license Possible Required MWSC library:


configuration: Options/Add-Ons:
Central
Control
room
Assumption:
control
level 80% of the turbine information will be
level
forwarded/used (=42,000 I/O’s)
subject to vary depending on project

PARK SERVER • 1 WinCC OA server • Redundant park server


42,000 I/O’s configuration Control center library
Park
Windpark
level • 6 WinCC OA UI client • Web Client(s)
level
WinCC OA TCP / IP
• Dist • External database (Oracle)
communication C

• 1 WinCC OA server • Redundant park server T


3,500 I/O’s configuration
• 1 WinCC OA UI client • Ultralight Client
Turbine
Turbine • Dist • External database (Oracle)
level
level Driver • 1 Driver: (e.g.) Turbine library
• IEC61400
• OPC
PLC • S7
• Modbus
• …
© Siemens AG 2014 All rights reserved.
2014-07-01 Petar Anic / VMM Wind
Proposed WinCC OA configurations – Variation 2b

Variation 2b WinCC OA license Possible Required MWSC library:


configuration: Options/Add-Ons:
CONTROL ROOM

Central
Control
SERVER
• 1 WinCC OA server • Redundant park server
room
control 16,000 I/O’s configuration
level
level • 6 WinCC OA UI client • Web Client(s) C
• Dist • External database (Oracle)
Control center library

WinCC OA TCP/IP
Park communication
Windpark
level
level
30% of the turbine information will be
forwarded / used (=157,500 I/O’s)
subject to vary depending on
project
• 1 WinCC OA server • Redundant park server
3,500 I/O’s configuration
• 1 WinCC OA UI client • Ultralight Client
Turbine
Turbine
level
level
Driver
• Dist
• 1 Driver: (e.g.)
• External database (Oracle)
T
• IEC61400
• OPC
PLC • S7 Turbine library
• Modbus
• …
© Siemens AG 2014 All rights reserved.
2014-07-01 Petar Anic / VMM Wind
Proposed WinCC OA configurations – Variation 2c

Variation 2c WinCC OA license Possible Required MWSC library:


configuration: Options/Add-Ons:
CONTROL ROOM

Central
Control
SERVER
• 1 WinCC OA server • Redundant park server C
room
control
level
16,000 I/O’s configuration
level • 6 WinCC OA UI client • Web Client(s) Control center library
• Dist • External database (Oracle) 30% of the turbine information will be
forwarded / used (=15,750 I/O’s)
PARK SERVER
WinCC OA TCP/IP • 1 WinCC OA server • Redundant park server subject to vary depending on project
communication
42,000 I/O’s configuration
Park
Windpark
• 6 WinCC OA UI client • Web Client(s)
level
level
• Dist • External database (Oracle)
C
Control center library
80% of the turbine information will be
• 1 WinCC OA server • Redundant park server forwarded/used (=42,000 I/O’s)
3,500 I/O’s configuration subject to vary depending on project
• 1 WinCC OA UI client • Ultralight Client
Turbine
Turbine • Dist • External database (Oracle)
level
level Driver • 1 Driver: (e.g.)
• IEC61400 T
• OPC
PLC • S7
• Modbus Turbine library
Control room server and park server do have
• … parallel communication to each turbine server.
© Siemens AG 2014 All rights reserved.
2014-07-01 Petar Anic / VMM Wind
Security information

Siemens provides products and solutions with industrial security functions that support the secure
operation of plants, solutions, machines, equipment and/or networks. They are important
components in a holistic industrial security concept. With this in mind, Siemens’ products and
solutions undergo continuous development. Siemens recommends strongly that you regularly
check for product updates.

For the secure operation of Siemens products and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept) and integrate each component into a holistic,
state-of-the-art industrial security concept. Third-party products that may be in use should also
be considered. For more information about industrial security, visit
http://www.siemens.com/industrialsecurity.

To stay informed about product updates as they occur, sign up for a product-specific newsletter.
For more information, visit http://support.automation.siemens.com.

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind
Multilevel Wind SCADA center information center

Petar Anic
WinCC OA Wind Technical Specialist
I IA AS SW ETM
Marktstrasse 3
7000 Eisenstadt, Austria
Phone: +43 (2682) 741 62747
Fax: +43 (2682) 741 52555
Mobile: +43 (664) 80117 62747
E-mail:
petar.anic@siemens.com

www.etm.at

© Siemens AG 2014 All rights reserved.


2014-07-01 Petar Anic / VMM Wind

You might also like