You are on page 1of 25

Part : 4 - AA 3

OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa


European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 1 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

MCS - LCB_II
List of Installation Parameters

Authorization Date D1: 27-Jun-1995

Running on PCB: GCA 21240 D1 - D3


GDA 21240 D1 - D3

Software Version: GAA 30082 BAC

Document Revision:

24 - May - 93 GAA 30082 AAA J. Schulte


- Original Document
03 - Dec - 93 GAA 30082 AAB A.Gerwing
- OTIS 2000 features add.
29 - Apr - 94 GAA 30082 AAC M. Hnida
- Triplex parameter added
02 - Jun - 94 GAA 30082 AAD M. Hnida
- Secure Access revised
16 - Jun - 94 GAA 30082 AAE J. Schulte
- BSM mode added
17 - Jan - 95 GAA 30082 BAA J. Schulte
- MCS220M, LSVF-W, ELD,
REM III added
06 - Jun - 95 GAA 30082 BAB A. Gerwing - not distributed
27 - Jun - 95 GAA 30082 BAC A.Gerwing - CPC-TYP, N+2,
ELD-MSG, ELD-DOOR

Copyright 1995, OTIS GmbH Berlin


No part of this document may be copied or reproduced in any form or by any means
without the prior written consent of OTIS GmbH.
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 2 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

System: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 TOP 2 Top position:


1 (1) 31
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 LOBBY 0 Lobby position:
0 (1) 31
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 BOTTOM 0 Bottom position:
0 (1) 30
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 CFT-P 255 Cafeteria Position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 OPERAT 1 Operation FCL/DCL/SAPB:
0 FCL
1 DCL
2 SAPB
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 EN-BSM 0 Enable BSM mode (for DCL: both Up- and Down Hall Calls at lobby):
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 CONFIG 0 General configuration:
0 ETO
1 NAO
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 PI 4 Type of serial Position Indicator:
0 7/16 Segment
1 Multil.
2 Australian Dot Matrix
3 Australian Dot Matrix with CUDL/CDDL
4 OTIS 2000: LCD and ELD
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
8 ELD-fOPG 20 front door movement time: opening
0 (0.1) 10.0 s
0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 ELD-fCLG 20 front door movement time: closing
0 (0.1) 10.0 s
0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 ELD-rOPG 20 rear door movement time: opening
0 (0.1) 10.0 s
0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 3 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

System (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

11 ELD-rCLG 20 rear door movement time: closing


0 (0.1) 10.0 s
0 = automatic (not yet implem.)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
12 ELD-LNG 5 set Language for ELD:
0 (1) 19
0 SwiGer, 1 SwiFRA, 2 SwiIta, 3 Fra, 4 Italy,
5 UK, 6 Spain, 7 Nether, 8 Ger, 9 Aus,
10 Sweden, 11 Luxem, 12 Belg, 13 Por, 14 Egy,
15 Denmar, 16 SthAfr, 17 Finlnd, 18 Ara, 19 Kuw
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
13 ELD-Sym1 0 Enable Non-Smoking symbol:
0 Disabled
1 symbol is displayed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
R) 14 ELD-DOOR 0 select type of door display:
R) 0: 1 COP for 1 door or
R) 2 COPs for 2 doors
1: only 1 COP for 2 doors
R)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
R) 15 ELD-MSG 0 enables customer messages:
R) 0: no customer messages are displayed by ELD
R) 1: customer messages are enabled (use SETUP-ELD
R) to define the texts)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 EN-SFR 0 Enable SFR (signal flicker):
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
17 LR-T 20 FAN (LR) time:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
18 EN-HLC 0 Enable Hall Lanterns on car calls:
0 Disabled
1 HLC
2 HL also during closing
3 HLC and during door closing
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
19 HDL-TY 0 Hall Direction Lantern Type of OTIS 2000 Hall Button Box:
0 Direction Indicator
1 Hall Lantern
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
20 HL-SET 0 Hall Lantern/Gong Setup:
0 HL/G at same pins
1 HL/G at 1 2/3 4
2 HL/G at 3 4/1 2
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 4 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Version: GAA 30082 BAC


System (continued):
No. Symbol Default Purpose and Range

21 CR-DIR 0 Correction Fast Run Preferred Direction:


0 Down
1 Up
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
22 EN-RR 0 Enable Reduced Run (RR):
0 Disabled
1 Enabled (short or medium run)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
23 DZCNT 1 Use DZ for SL counting (for Short Run):
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
24 EN-DZI 0 Enable DZI (Door Zone Indicator):
0 Disabled
1 Enabled (only if no Door ByPass)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
25 ERO-TYP 0 Define ERO type
0 without limit
R) 1 with limit at terminal landings (same as TCI-limit)
R) 2 ERO-input disabled (for LCB_II version D2)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
26 C-CHK 0 Enable C-Circuit Check:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
27 MD/AES 0 select use of MD input (P7:9, only MCS220M):
0 not connected
1 MD: DCS-input for Multi Door (manual plus autom. landing
R) doors)
R) 2 AES: ES-input if RSS or ESB is used
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
R) 28 CPC-TYP 0 select use of CPC outputs:
R) 0 car position contact
1 ’car here’ light
R)
2 french SSM
R) qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
R) 29 N+2 WIRE 0 enable 3 wire buttons:
R) 0 normal car and hall buttons
R) 1 3 wire car buttons
R) 1 3 wire hall buttons
1 3 wire car and hall buttons
R)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 5 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

OCSS: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 CPR-T 20 Car Call Preference:


0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 ARD-P 255 Automatic Return Device Position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 ARD-T 0 Set Delay for ARD (Automayic Return Device) mode:
0 (10) 2550 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 L-PARK 0 Lobby Park Option:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 CTL/PKS 0 Select CTL or PKS switch:
0 CTL switch is connected
1 PKS switch is connected
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 PKS-P 255 Parking Service Position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 PKS-TY 0 Parking Shutoff Type:
0 ETO
1 NAO
2 ETO with door open after shutdown
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 PKS-T 0 Parking Shutoff Time:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
8 PKS-DO 0 PKS default door:
0 Both doors will open at PKS-P
1 Only front door opens
2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 EN-SHB 0 Enable Separate Hall Buttons:
0 Normal HB-operation
1 Rear HB as Separate Riser
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 DCP-T 50 Time until DCP-mode (delayed car protection):
25 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
11 CTL-DO 0 CTL default door (car to any landing):
0 Both doors will open at CTL-P
1 Only front door opens
2 Only rear door opens
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 6 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

OCSS (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range


12 CTL-P 255 CTL (Car To Any Landing) position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
13 ANS 0 ANS (anti nuisance service):
0 Disabled
>0 Number of calls to trigger ANS
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
14 ATT 0 ATT (Attendant Service) type:
0 Start with DCB or RDCB
1 Start with ATTU or ATTD
2 NAO (USA)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
15 ISC 0 Independent Service:
0 Start on CCB
1 Start on DCB
2 Start on ISD/ISU
3 NAO (USA)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 CTL-TY 0 Select Car To Landing Type:
0 ETO
1 NAO
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
17 SPEECH 0 Speech Mode:
0 Floor message on CC only
1 Floor message also on HC
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
18 DOC 0 Door Reopen Count:
0 No limit
1 (1) 255 Number of allowed door reopenings
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
19 DS-CCB 0 Disable CCs behind moving car:
0 CCs behind allowed
1 CCs behind not allowed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
20 DS-DOB 0 Disable DOB button:
0 DOB/RDOB always enabled
1 DOB disabled if door closed
2 RDOB disabled if door closed
3 Both disabled if door closed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 7 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Group: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 GRP-NO 1 Car identifier in group:


1 (1) 3
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 GROUP 1 Number of cars in group:
1 (1) 3
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 CNL 1 Cars parking in Lobby:
1 (1) 3
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 MIT-ST 0 MIT (Moderate incomming traffic) Startdelay:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 MIT-T 0 MIT Time-Out:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 MIT-VD 0 MIT Variable Interval Dispatch:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 DUPK-P 255 Dual Up Peak Border Position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 DUPK-G 0 Dual Up Peak Group:
0 Car belongs to subgroup 1
1 Car belongs to subgroup 2
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
8 MOT-T 0 MOT (Moderate Outgoing traffic) Time-Out:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 EN-UCB 0 Enable Up Call Bypass:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 TFS-P 255 Transfer Floor Position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
11 PARK-1 255 Park Clock Position 1:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
12 PARK-2 255 Park Clock Position 2:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 8 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Group (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

13 PARK-3 255 Park Clock Position 3:


0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
14 PARK-4 255 Park Clock Position 4:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
15 PARK-5 255 Park Clock Position 5:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 PARK-6 255 Park Clock Position 6:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
17 PARK-7 255 Park Clock Position 7:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
18 PARK-8 255 Park Clock Position 8:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
19 EN-ZBS 0 Enable separate basement zone:
0 No free car parks in basement zone
1 A free car parks in basement zone
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 9 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Drive: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 DRIVE 1 Drive Type:


0 1-SP
1 2-SP, G-L XADO
2 G-S/D XADO
3 G-L with SL XADO
4 G-L with SL ADO
5 2-SP, G-L ADO
6 G-S/D ADO
7 SPEC60
8 G-D NAO XADO
9 G-D NAO ADO
10 MOT-VLV ADO
11 SOL-VLV ADO
12 MOT-VLV XADO
13 SOL-VLV XADO
14 LSVF ADO
15 LSVF XADO
16 LSVF-W ADO
17 LSVF-W XADO
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 C-TYPE 2 Controller Type:
0 MCS 310 (Europa 2000)
1 MCS 310 CA, HY (Cargo 2000)
2 MCS 120, MCS 220 (OTIS 2000)
3 MCS 220 M (OTIS 2000)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 1AT 5 1A Time:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 2AT 5 2A Time:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 DDP 32 DDP Time (fast run):
0 (1) 45 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 3P 32 3P Time (slow run):
0 (1) 45 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 SPEED 100 Speed (fast run mode):
25
40
63
100
160
175
250 cm/s
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 10 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Drive (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

7 EN-MPD 0 Enable Motor Protection Device:


0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
8 MPD-T 10 Motor Protection Device Time:
0 (1) 254 s
255 wait forever
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 HY-TYP 0 Hydro Drive Type for Hydro:
0 Star - Delta
1 Soft
2 Direct
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 L-T 10 Set Star/Soft Time for Hydro:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
11 UX-D 20 Set Star/Delta gap / add. Soft Time (L+UX) for Hydro:
0.06 (0.004) 0.2 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
12 UXT-D 0 Set delay between UX and UXT for Hydro: (contract option)
0 (0.1) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
13 EN-PLS 1 Enable PLS1 (Oil-Max-Pressure Limit Switch) for Hydro:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
14 EN-OTS 1 Enable OTS (Oil-Over Temperature Switch) for Hydro:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
15 ACD/UXT 0 Select ACD (Anti Creeping Device) or UXT output for Hydro:
0 ACD and UXT disabled
1 ACD enabled
2 UXT enabled (contract option)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 P-OFF-D 0 Set Power Off delay for LSVF-W
0, 255 Disabled
1 (1) 254 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
17 P-ON-D 10 Set Power On delay for LSVF-W
8 (1) 20 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 11 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Drive (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

18 EN-J 1 Enable 3-Phase Detection (J-Relay)


0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
19 J-T 1 Number of periods necessary to detect a fault
0 (1) 4
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
20 EN-BCD 1 Enable Brake Current Detection:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
21 BON-D 10 Delay of BCD (after lifted brake)
0 (0.1) 10 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
22 BFLT-T 15 Max. fault time of BCD
0 (0.1) 10 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
23 BOFF-D 15 Delay of BCD (after fallen brake)
0 (0.1) 10 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 12 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Doors: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 DOOR 2 Type of Doors:


0 FLH
1 9550T & ACG
2 9550T & TLD / DO_2000 (DC-relay)
3 OVL / MRDS
4 OVL & ACG
5 DO_2000 (DO-relay)
6 MCG
7 Kiekert / MLI & ACG
8 Kiekert / MLI & TLD/CLD
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 REAR 2 Type of Rear Doors:
0 FLH
1 9550T & ACG
2 9550T & TLD / DO_2000 (DC-relay)
3 OVL / MRDS
4 OVL & ACG
5 DO_2000 (DO-relay)
6 MCG
7 Kiekert / MLI & ACG
8 Kiekert / MLI & TLD/CLD
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 EN-DDO 0 Enable DDO (double door operation):
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 MIXDOR 0 Mixed Dooroperators:
0 Same operators front/rear
1 Different operators front/rear
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 DBP-TY 1 Type of Door Bypass circuit:
0 DBP operated (4-relay)
1 LVC operated (3-relay)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 SEL-CMR 0 select separate CM relay output (MCS220M)
0 (one door) CMR at RDC-output (P6:10)
1 (two doors) CMR at RSL (IO no. 785)
NOTE: only applicable for FLH, MCG, ACG
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 LDR 0 Limited Door Reversal:
0 Full DOB, full EDP, full LRD
1 Full DOB, limited EDP, full LRD
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 EN-PMO 0 Enable PMO (door time monitoring):
0 Disabled
1 Enabled
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 13 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Doors (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

8 EN-NDG 0 Enable NDG (nudging):


0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 NDG-T 20 Nudging Time:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 EN-CK 0 Enable Cancel Doortime with CCB:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
11 DW-DLY 10 Debouncing Time of Door Contact DW:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
12 DO-BEL 0 Open Door Bell Timer:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
13 MIN-C 20 Min Doortime Car:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
14 MAX-C 40 Max Doortime Car:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
15 MIN-H 40 Min Doortime Hall:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 MAX-H 60 Max Doortime Hall:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
17 DOR-T 0 Door reverse time:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
18 RDOR-T 0 Rear door reverse time:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
19 DTC-T 20 Door Close Protection Time:
10 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
20 DTO-T 20 Door Open Protection Time:
10 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
21 LOB-NT 40 Lobby Door Time:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
22 CFT-NT 40 Cafeteria Door Time:
0 (0.1) 25.5 s
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 14 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Doors (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

23 SPB-NT 0 Special DOB Door Time:


0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
24 DHB-T 120 DHB Doortime:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
25 WCO-T 0 Wild Car Door Time:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
26 SHO-T 0 Shabat Door Time:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
27 SHO-LT 0 Shabat Lobby Door Time:
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
28 DAR-T 60 MPD/Hydro Door Open Time:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
29 DXT-T 0 DXT Time (extended door time):
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 15 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Position Reference Version: GAA 30082 BAC

No. Symbol Default Purpose and Range


0 LV-MOD 2 Leveling Mode:
0 DZ-STP stop with DZ:
use DZ-DLY (in 4 ms units)
1 LV-STP stop with LVU/LVD:
for CA-MOD=0 (RLEV-2):
set LV-U-D, LV-D-D = 0
for CA-MOD=1 (RLEV-3):
use LVU-5D, LVD-5D (in 4 ms units)
2 DZ-STP stop with DZ, 1LV/2LV:
use LV-U-D, LV-D-D (in 4 ms units)
3 IP-STP stop with IPU, IPD: (for 1-Speed Drive)
use IPU-D, IPD-D (unit depends on
T-BASE)
4 UIS/DIS stop with UIS, DIS: (for Hydraulic Drive)
use LV-U-D for DIS (in 4 ms units)
use LV-D-D for UIS (in 4 ms units)
Note: auto-stop for
- Gamma S/D, Spec_60 and Dynalift on RUN signal (110V input)
- LSVF-W on RN (coded inputs)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 DZ-TYP 0 DZ coding:
0 DZ = 1LV
1 DZ = 1LV and 2LV
2 POSY operation (if neither RLV nor ADO)
to stop: DZ = 1LV and 2LV
after stop: DZ = 1LV or 2LV
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 DZ-DLY 0 Delay for DZ:
0 (0.004) 1 s (LV-MOD = 0)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 LV-U-D 12 Delay for DZ, 1LV/2LV (in up direction):
0 (0.004) 1 s (LV-MOD = 1, 2, 4)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 LV-D-D 12 Delay for DZ, 1LV/2LV (in down direction):
0 (0.004) 1 s (LV-MOD = 1, 2, 4)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 T-BASE 0 Timebase for IPU-D, IPD-D, 1LS-D and 2LS-D:
0 0.1 s
1 0.004 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 IPU-D 0 Delay for IPU:
0 (0.1) 25.5 s (T-BASE=0)
0 (0.004) 1 s (T-BASE=1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 IPD-D 0 Delay for IPD:
0 (0.1) 25.5 s (T-BASE=0)
0 (0.004) 1 s (T-BASE=1)
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 16 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Position Reference (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

8 1LS-D 0 Delay for 1LS:


0 (0.1) 25.5 s (T-BASE=0)
0 (0.004) 1 s (T-BASE=1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 2LS-D 0 Delay for 2LS:
0 (0.1) 25.5 s (T-BASE=0)
0 (0.004) 1 s (T-BASE=1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 EN-RLV 0 Enable RLV operation:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
11 RLV-TY 0 RLV - Type:
0 RLV Relevelling
1 DRLV Delayed Relevelling (using DIS1)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
12 RL-CNT 3 Limit of RLV steps:
0 (1) 255
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
13 RL-DIS 255 Set RLV time up (DIS lost):
0 (0.1) 25.5 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
14 RL-UIS 255 Set RLV time down (UIS lost):
0 (0.1) 25.5 s
0 (0.004) 1 s (hydraulic drive)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
15 RL-U-D 0 Set RLV delay up:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 RL-D-D 0 Set RLV delay down:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 17 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Cargo: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 CA-MOD 0 CARGO mode:


0 RLEV/RLEV-2
1 RLEV-3
2 Class-C2 (not authorized yet)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 LVU-5D 0 Delay for LV stop (UP 0.5 load):
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 LVD-5D 0 Delay for LV stop (DOWN 0.5 load):
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 BI-T 0 Class C2: time-out for Bolts In:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 BO-T 0 Class C2: time-out for Bolts Out:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 MVU-T 0 Class C2: time-out for Move Up:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 MVD-T 0 Class C2: time-out for Move Down:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 PLS4-T 0 Class C2: time-out for PLS4:
0 (0.004) 1 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 18 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Emergency: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 ES-TYP 0 Define ES-Type:


0 ESS connected
1 ESB connected (closed door will remain closed)
2 ESB connected (closed door will open)
R) 3 ES-input disabled (for LCB_II version GCA 21240 D2 / D3)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 EFO-P 255 EFO (emergency fireman operation) position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 EFO-DC 0 EFO with doors closed:
0 Disabled
1 (1) 255 s DC time
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 EFO-DO 0 EFO default door:
0 Both doors will open at EFO position
1 Only front door opens
2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 EFO-OP 0 EFO override option:
0 No override possible
1 XEFO input overrides EFO after arrival at return landing
2 After EFS no EFO is permitted if EFO or AEFO are still active
3 Functions 1 + 2 together
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 EFONDG Enable nudging speed for EFO
0 Door closes with full speed
1 Door closes with nudging speed
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 ASL-P 255 ASL (alternate service landing) position:
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 EFS-TY 0 Type of EFS (Emergency Fireman Service) (if EFK (ASL) connected):
0 EFO
1 EFS 1 (Aut.)
2 EFS 2 (Man.)
3 ANSI (USA)
4 British Standard
5 Swiss Standard
6 Australia
7 New Zealand
R) 8 EFS 2 (Man. with ESK)
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 19 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Emergency (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

8 EFS-DO 0 EFS default door:


0 Both doors will open position
1 Only front door opens
2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 EFS-RT 0 EFS return time (time EFK must be low to force car back to EFO landing if
EFK is switched on again while in EFS):
0-39 Function disabled
40-255 Time (in 100 ms units) EFK must be low
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
10 EN-BAK 0 Enable E2P-backup of EFO/EFS:
0 Disable backup
1 Enable backup
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
11 HDWPOS 0 Hardware position reference:
0 Disabled
1 One contact per floor
2 Binary coded contacts
3 Signal at every odd floor
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
12 EPO-P 255 EPO (emergency power operation) Position:
0 (1) 31 EPO A/C (position)
EPO E (hydro: bottom)
= 32 EPO B/D (next floor)
EPO F (hydro: next floor down)w
>32 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
13 EPO-DC 0 EPO with doors closed:
0 Disabled
1 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
14 EPO-DO 0 EPO default door:
0 Both doors will open at EPO position
1 Only front door opens
2 Only rear door opens
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
15 EPO-PR 0 EPO priority if EFO/EFS:
0 No prio for EPO
1 EPO has priority
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
16 EQO 0 Earthquake Operation Type:
0 California
1 New Zealand
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 20 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Emergency (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

17 EPS-TYP 0 Express Priority Service:


x0 automatic ISC
x1 return to normal
x2 automatic CHCS
0x immediate return
1x stop at next commitable
2x serve car calls en route
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
18 EHS-T 0 EHS time-out:
0 Disabled
1 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 21 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Security: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 EN-FPD 0 Enable FPD (fireproof doors):


0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 EN-IST 0 Enable IST (intermittent stop):
0 Disabled
1 In up direction only
2 In down direction only
3 In both directions
5 In up direction only, if ISTS active
6 In down direction only, if ISTS active
7 In both directions, if ISTS active
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 IST-P 255 Intermittent Stop Position:
0 (1) 31
>31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 EN-CRO 0 Enable CRO (card reader operation):
0 Disabled
1 Single contact reader
2 Australian Card Key sec type 2
3 Australian Card Key sec type 1
4 Multi contact reader
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 GCBTYP 0 General Control of Buttons type:
0 disabled
1 GCB_1
2 GCB_2
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 RIOT-P 255 RIOT Operation Position:
0 (1) 31
>31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 22 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Security (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

6 SACTYP 0 Secure Access Type:


1 SAC enabled, without ISC override
3 SAC enabled, with ISC override
5 SAC enabled, without ISC override, clear only if sec. enabled
7 SAC enabled, with ISC override, clear only if security enabled
else SAC disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 SAC-D1 255 Secure Access digit 1:
0 (1) 6
>6 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
8 SAC-D2 255 Secure Access digit 2:
0 (1) 6
>6 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 SAC-D3 255 Secure Access digit 3:
0 (1) 6
>6 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 23 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Test: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 TPOS 1 255 Test position 1 (automatic test run):


0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
1 TPOS 2 255 Test position 2 (automatic test run):
0 (1) 31
> 31 Disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
2 TDELAY 255 Test Delay for automatic test run:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
3 NoAdrChk 0 Disable safety check: address of TCI, 1LS and 2LS regarding to Std-IO-List
0 RSL safety check enabled
1 RSL safety check disabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
4 NoDW_Chk 0 Disable DW-check during NOR:
0 DW is checked when door open
1 No DW-check during NOR
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
5 DEBUG 0 Debug Parameter:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
6 DEBUG1 0 Debug Parameter 1:
0 (1) 255 s
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
7 EN-1CL 0 Enable Init_1CL: default position (Mot_VLV.):
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
8 EN-EVT 0 Enable storage of 10 events into E2PROM:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
9 EN-CRT 0 Enable contract handling: Operate up to 32 openings:
0 Disabled
1 Enabled
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 24 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

Index DOC, 6 EN-FPD, 21


DOOR, 12 EN-HLC, 3
DOR-T, 13 EN-IST, 21
A DO-BEL, 13 EN-J, 11
ACD/UXT, 10 DRIVE, 9 EN-MPD, 10
ANS, 6 DS-CCB, 6 EN-NDG, 13
ARD-P, 5 DS-DOB, 6 EN-OTS, 10
ARD-T, 5 DTC-T, 13 EN-PLS, 10
ASL-P, 18 DTO-T, 13 EN-PMO, 12
ATT, 6 DUPK-G, 7 EN-RLV, 16
DUPK-P, 7 EN-RR, 4
B DW-DLY, 13 EN-SFR, 3
DXT-T, 14 EN-SHB, 5
BFLT-T, 11 DZCNT, 4 EN-UCB, 7
BI-T, 17 DZ-DLY, 15 EN-ZBS, 8
BOFF-D, 11 DZ-TYP, 15 EN-1CL, 23
BON-D, 11
EPO-DC, 19
BOTTOM, 2
E EPO-DO, 19
BO-T, 17
EPO-P, 19
EFONDG, 18
EPO-PR, 19
C EFO-DC, 18
EPS-TYP, 20
EFO-DO, 18
CA-MOD, 17 EQO, 19
EFO-OP, 18
CFT-NT, 13 ERO-TYP, 4
EFO-P, 18
CFT-P, 2 ES-TYP, 18
EFS-DO, 19
CNL, 7 EFS-RT, 19
CONFIG, 2 EFS-TY, 18 G
CPC-TYP, 4 EHS-T, 20 GCBTYP, 21
CPR-T, 5 ELD-DOOR, 3 GROUP, 7
CR-DIR, 4 ELD-fCLG, 2 GRP-NO, 7
CTL-DO, 5 ELD-fOPG, 2
CTL-P, 6 ELD-LNG, 3
CTL-TY, 6 H
ELD-MSG, 3
CTL/PKS, 5 ELD-rCLG, 3 HDL-TY, 3
C-CHK, 4 ELD-rOPG, 2 HDWPOS, 19
C-TYPE, 9 ELD-Sym1, 3 HL-SET, 3
EN-BAK, 19 HY-TYP, 10
D EN-BCD, 11
DAR-T, 14 EN-BSM, 2 I
DBP-TY, 12 EN-CK, 13 IPD-D, 15
DCP-T, 5 EN-CRO, 21 IPU-D, 15
DDP, 9 EN-CRT, 23 ISC, 6
DEBUG, 23 EN-DDO, 12 IST-P, 21
DEBUG1, 23 EN-DZI, 4
DHB-T, 14 EN-EVT, 23
Part : 4 - AA 3
OTIS FIELD COMPONENT MANUAL No. : GCA 21240 D VIIIa
European and Transcontinental
Operations Vintage : 01 / 8
Software Data
PRODUCT Page : 25 / 25
ADMINISTRATION
MCS - LCB_II
List of Installation Parameters Date : 27-Jun-1995

J PARK-2, 7 TPOS1, 23
J-T, 11 PARK-3, 8 TPOS2, 23
PARK-4, 8 T-BASE, 15
PARK-5, 8
L PARK-6, 8
LDR, 12 U
PARK-7, 8
LOBBY, 2 PARK-8, 8 UXT-D, 10
LOB-NT, 13 PI, 2 UX-D, 10
LR-T, 3 PKS-DO, 5
LVD-5D, 17 PKS-P, 5 W
LVU-5D, 17 PKS-T, 5 WCO-T, 14
LV-D-D, 15 PKS-TY, 5
LV-MOD, 15 PLS4-T, 17
LV-U-D, 15 P-OFF-D, 10 1
L-PARK, 5 P-ON-D, 10 1AT, 9
L-T, 10 1LS-D, 16
R
M RDOR-T, 13 2
MAX-C, 13 REAR, 12 2AT, 9
MAX-H, 13 RIOT-P, 21 2LS-D, 16
MD/AES, 4 RLV-TY, 16
MIN-C, 13 RL-CNT, 16
MIN-H, 13 3
RL-DIS, 16
MIT-ST, 7 RL-D-D, 16 3P, 9
MIT-T, 7 RL-UIS, 16
MIT-VD, 7 RL-U-D, 16
MIXDOR, 12
MOT-T, 7
MPD-T, 10 S
MVD-T, 17 SACTYP, 22
MVU-T, 17 SAC-D1, 22
SAC-D2, 22
SAC-D3, 22
N SEL-CMR, 12
NDG-T, 13 SHO-LT, 14
NoAdrChk, 23 SHO-T, 14
NoDW_Chk, 23 SPB-NT, 14
SPEECH, 6
O SPEED, 9
OPERAT, 2
T
P TDELAY, 23
TFS-P, 7
PARK-1, 7
TOP, 2

You might also like