Professional Documents
Culture Documents
: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 1 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
1 55
Date:DRAFT0
MCS – TCBC
Service Tool Manual
2 55
Table of Contents
Date:DRAFT0
1 Introduction ......................................................................................3
2 Tree Structure ..................................................................................4
2.1 Key Overview ...................................................................................................... 5
2.2 Short Keys ........................................................................................................... 6
3 Menu Functions of the Service Tool ...............................................7
3.1 Status Functions ................................................................................................. 7
3.1.1 Status Function Display M - 1 - 1 - … ................................................................... 8
3.1.2 Status Calls Menu S8 / M - 1 - 1 - 1 ................................................................... 9
3.1.3 Status Inputs Menu S7 / M - 1 - 1 - 2 ................................................................. 10
3.1.4 Status Outputs Menu M - 1 - 1 - 3 ...................................................................... 11
3.1.5 Status Group Menu M - 1 - 1 - 4 ......................................................................... 12
3.1.6 Status ICSS Menu M - 1 - 1 - 5 ........................................................................... 13
3.1.7 Status Command Menu M - 1 - 1 - 6................................................................... 14
3.1.8 Status Drive Menu (TCBC only) M - 1 - 1 - 7 ...................................................... 16
3.2 Test Functions................................................................................................... 18
3.2.1 Test Events Menu S6 / M - 1 - 2 - 1 ................................................................... 19
3.2.2 Test Diagnostics Menu M - 1 - 2 - 2 .................................................................... 21
3.2.3 Test Part-No Menu M - 1 - 2 - 3 .......................................................................... 23
3.2.4 Test RSL Menu M - 1 - 2 - 4 ............................................................................... 24
3.2.5 Test Selftest Menu M - 1 - 2 - 5 .......................................................................... 25
3.3 Setup Functions ................................................................................................ 27
3.3.1 Setup Install Menu S4 / M - 1 - 3 - 1 .................................................................. 28
3.3.2 Setup RSL Menu S5 / M - 1 - 3 - 2 .................................................................... 29
3.3.3 Setup Allowed Mask Menu M - 1 - 3 - 3 .............................................................. 31
3.3.4 Setup Position Indicator Menu M - 1 - 3 - 4 ........................................................ 37
3.3.5 Setup DCS-Run Menu M - 1 - 3 - 5..................................................................... 38
3.3.6 Setup ELD Menu M - 1 - 3 - 6 ............................................................................. 41
3.4 Tools Functions ................................................................................................ 47
3.4.1 Search IO M - 2 - 1 ............................................................................................. 48
3.4.2 Erase IO M - 2 - 2 ............................................................................................... 49
3.4.3 Setup Inst M - 2 - 3 ............................................................................................. 50
3.4.4 Setup Door M - 2 - 4 .......................................................................................... 51
3.4.5 Show History M - 2 - 5 ........................................................................................ 52
3.4.6 Smart Button Program M - 2 - 6 .......................................................................... 53
3.4.7 Smart Button Test M - 2 - 7 ................................................................................ 54
3.4.8 Operate Memory M - 2 - 9 .................................................................................. 55
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 3 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
3 55
Date:DRAFT0
1 Introduction
The Service Tool is a pocket terminal that lets you control all elevator functions:
Monitoring of software states, system inputs and outputs and system messages
Setup of installation parameters
Use of software tools.
The access of each function is controlled by the Menu System which allows convenient
work with the Service Tool.
The Service Tool Manual describes the Menu System and the single Service Tool functions.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 4 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
4 55
Date:DRAFT0
2 Tree Structure
All Service Tool functions are organized under the Tree-Structure.
It is divided in a SYSTEM path, where you have access to the main Service Tool functions
STATUS (system monitoring)
TEST (system test functions)
SETUP (setup of system environment)
and in a TOOL path.
The TOOLS path contains the Service Tool functions which supports installation and
maintenance of the elevator.
M Main Menu
1 2
F System Menu Tools
1 2 3
S Status Menu Test Menu Setup Menu
Note:
(*) M117 TCBC only
M1334 not in LCB2 earlier than CAA
M25 TCB only
M26 LCB2 only
M27 LCB2 only
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 5 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
5 55
Date:DRAFT0
2.1 Key Overview
The Menu System allows you to access the single Service Tool functions if you choose the
right path through the Tree Structure by pressing the corresponding key (number 1,2,...8).
If there is only one number to choose, you can call the function also with the key ENTER.
The ">" character indicates that you can toggle between the different menus using the
GOON or GOBACK.
If you want to jump back to one of the three Main Level of the architecture (MONITOR,
FUNCTION or SET) you can press the Main Level keys M , F or S.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 6 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
6 55
Date:DRAFT0
2.2 Short Keys
The Short Keys provide direct access to certain , often used Service Too functions, elimi-
nating the need to step through the menu structure.
The Service Tool functions Input, Calls, Install, RSL and Events are assigned to the
Standard Short Keys S4 (Shift 4), S5 (Shift 5), S6 (Shift 6), S7 (Shift 7), S8 (Shift 8).
Short Key S9 (Shift 9) is a free programmable key to store any position of the Tree –
Structure as a sixth Short Key. Once you have stored S9 (by pressing S9 at the desired
position) you can reset it only on level M (Main – Menu).
Example
press keys description
M - 1 -1 - 3 use M113 to view system outputs
S9 Program S9 as Shortkey for M-1-1-3
S7 View system inputs
S8 Enter calls
S9 Use S9 to view system outputs
S7 View system inputs
M – S9 Reset S9
7 55
Date:DRAFT0
3 Menu Functions of the Service Tool
The following chapters describe the functions of the Service Tool. Differences between
LCB2, HCB, TCB and TCBC are clearly marked.
8 55
Date:DRAFT0
3.1.1 Status Function Display M-1-1-…
The first row of the Service Tool display is identical for all Status Functions:
9 55
Date:DRAFT0
3.1.2 Status Calls Menu S8 / M-1-1-1
With this function you can view the general status of the system and enter calls.
Description of display:
10 55
Date:DRAFT0
3.1.3 Status Inputs Menu S7 /M-1-1-2
This function displays system inputs.
The inputs are arranged in pages, each page containing four inputs. Active inputs are dis-
played in upper case letters, inactive inputs are displayed in lower case letters. See docu-
ment Reference List for a list of available inputs.
Only those inputs are displayed which are currently used by the software, that means thath
the list of inputs is rearranged every time an installation parameter is changed. The com-
plete list is shown if the parameter DISP-ALL=1 is programmed.
UP / DOWN display a brief description of the input page in the first row.
11 55
Date:DRAFT0
3.1.4 Status Outputs Menu M-1-1-3
This function displays system outputs.
The outputs are arranged in pages, each page containing four outputs. Active outputs are
displayed in upper case letters, inactive outputs are displayed in lower case letters. See
document Reference List for a list of available outputs.
TCBC
Only those outputs are displayed which are currently used by the software, that means that
the list of outputs is rearranged every time an installation parameter is changed. The com-
plete list is shown if the parameter DISP-ALL=1 is programmed.
TCBC
UP / DOWN display the selected drive type in the first row of the display.
TCBC
UP / DOWN display a brief description of the output page in the first row.
TCBC
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 12 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
12 55
Date:DRAFT0
3.1.5 Status Group Menu M-1-1-4
This function displays the status of all cars in the group.
The first line always displays the status of the own car, while the second line displays the
status of one of the other cars in the same group.
If no group communication is active (i.e. not installed or broken link), then the following dis-
play is shown:
GOON / GOBACK select the car in the second line of the display
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 13 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
13 55
Date:DRAFT0
3.1.6 Status ICSS Menu M-1-1-5
This function displays whether ICSS controllers (for EMS) are detected in the group.
ICSS IS ONLINE
ICSS2 IS OFFLINE
14 55
Date:DRAFT0
3.1.7 Status Command Menu M-1-1-6
This function shows the Door- and Motion-Commands which are generated by the Opera-
tional Control part of the Software.
Description of display:
15 55
Description of the commands:
Date:DRAFT0
Type Display Description
Door Commands OPEN open door
DEEN deenergize door (TCI, DTO, DTC, ESB)
CLD1 close door; no DOB, no LRD, no EDP
CLD2 close door; full DOB, full LRD, full EDP
CLD3 close door; full DOB, full LRD, lim EDP
CLD4 close door; full DOB, lim LRD, lim EDP
CLD5 close door; full DOB, no LRD, no EDP
CLD6 close door; full DOB, no LRD, lim EDP
CLD7 close door; lim DOB, no LRD, lim EDP
CLD8 close door; lim DOB, no LRD, no EDP
CLD9 close door; full SGS, nothing else
Abbreviations:
DOB = Door Open Button
LRD = Light Ray Device
PP = Passenger Protection
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 16 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
16 55
Date:DRAFT0
3.1.8 Status Drive Menu (TCBC only) M-1-1-7
TCBC
Displays the status and commands of the drive subsystem.
Description of display:
Display description values
1 Running Drive Status see table below
A01u NOR FR ][][
Drv: Running .
1
or
1 Tci Drive Command Corr Correction Run into specified
A01u INS IN ][][ direction
Cmd: Tci up . Resc Rescue Run to next floor into
1 2 specified direction
Tci Inspection Run (TCI) into speci-
fied direction
Ero Inspection Run (ERO) into spec-
ified direction
2 up specified direction up move up
down move down
stop don't move
1 at05 Actual Target Top…Bottom
A01u NOR FR ][][ (final destination)
at05mt05nc02af01 2 mt05 Motion Target Top…Bottom
1 2 3 4 (Accepted Target
from Drive)
3 nc02 Next Commitable Top…Bottom
Floor
4 af01 Actual Floor Top…Bottom
TCBC
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 17 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
17 55
TCBC
Description of the Drive Status: Date:DRAFT0
TCBC
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 18 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
18 55
Date:DRAFT0
3.2 Test Functions
These functions provides access to the diagnostic functions of the system and allow to test
some basic functionalities.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 19 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
19 55
Date:DRAFT0
3.2.1 Test Events Menu S6 /M-1-2-1
View all events which has been stored since last PowerOn.
Normally all events are cleared when the power is switched off. Set parameter EN-EVT=1
to store max. 10 events into E2Prom.
View Events
Description of display:
20 55
Erase Events
You can either erase all events which are stored in the system or erase aDate:DRAFT0
single event.
Erase EVENTS ?
n=0 y=2 > .
Erase EVENTS ?
done! .
21 55
Date:DRAFT0
3.2.2 Test Diagnostics Menu M-1-2-2
This menu displays the diagnostic values which have been stored in the E2Prom. These
values are memorized even if the power is switched off.
01 DIAG ACT-T .
000:00:00:01 .
View Diagnostics
Description of display:
3 03 days 0-30
4 04 hours 0-24
5 05 minutes 00-59
1 03 DIAG UP-CNT number and text of diagnos- see Service Tool
1 tic value Reference List for a
01 DIAG UP-CNT . list of existing diag-
000000023 . nostic values
2 2 000000023 counter
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 22 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
22 55
Erase Diagnostics
You can either erase all values which are stored in the system or erase aDate:DRAFT0
single value.
Erase DIAGN. ?
n=0 y=2 > .
Erase DIAGN. ?
done! .
23 55
Date:DRAFT0
3.2.3 Test Part-No Menu M-1-2-3
Displays the Software Configuration Numbers (SCN) of the software.
No. GAA30081AAA.
28-Aug-01 11:32
1 Unit-Number
EE=47AG2375 . 1 47AG2375
.
1 1 47CE2375 Unit-Number
EE=47CE2375 .
.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 24 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
24 55
Date:DRAFT0
3.2.4 Test RSL Menu M-1-2-4
Test the functionality of Remote Stations by address.
ADR> .
.
0 … 9 enter an RS address
Description of display:
Note that the elevator software cannot update the RSL I/Os as long as long as this menu is
selected!
For security reasons, some I/Os (e.g. DO-5 outputs ST1-ST3) cannot be changed by this
menu.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 25 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
25 55
Date:DRAFT0
3.2.5 Test Selftest Menu M-1-2-5
Performs a selftest of the software.
PR ? EE ? RA ?
RS ? .
A blinking '?' indicates that the corresponding test is running. After completion of the test,
the display shows '+' or '-', respectively.
TCBC
GOON / GOBACK cancel the actually running test and start the next test
display the next/previous RS-error status
TCBC
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 26 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
26 55
Description of display:
Date:DRAFT0
Display description values
1 PR x EPROM test ? the test has not yet been completed
1 2 3 + the checksum of the EPROM is correct
PR x EE - RA + - the EPROM is corrupted
RS05Ar000. replace the EPROM!
4 5 6 x the test has been skipped (TCBC only)
2 EE - E2Prom test ? the test has not yet been completed
+ the content of the E2Prom (parame-
ters, I/Os, diagnostic values) has not
been changed since the last selftest
- Any value in the E2Prom has been
changed since last selftest
Do this test once again. If you don't
get a '+' now, replace the E2Prom.
x the test has been skipped (TCBC only)
3 RA + RAM test ? the test has not yet been completed
+ the RAM is ok
- the RAM is corrupted
replace board
x the test has been skipped (TCBC only)
4 RS05 RS test 04-63
This RS has a problem as described be-
low
5 Ar Remote Station is Ar Available in Setup, but physically not
A – Available responding
a – not available check address configuration of RS
R – Responding check wiring and connection
r – not responding replace RS
aR Not available in Setup, but physically
responding
check I/O-setup
find misconfigured RS
AR Available in Setup, and also respond-
ing; Parity Error detected
There are multiple RS with the
same address in the system
6 000 Parity Error Coun- 000-999
ter
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 27 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
27 55
Date:DRAFT0
3.3 Setup Functions
These functions allow to adapt the system to the needs of the jobsite. All values which are
changed by these functions are stored into E2Prom.
The E2P-Selftest (M1-2-5) will display '-' if any value has been changed since the last selft-
est.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 28 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
28 55
Date:DRAFT0
3.3.1 Setup Install Menu S4 /M-1-3-1
Description of display:
Note:
A new DCS run is required if TOP or BOTTOM is changed.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 29 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
29 55
Date:DRAFT0
3.3.2 Setup RSL Menu S5 /M-1-3-2
View and setup RSL addresses.
The addresses can only be changed if the car is not moving.
IO I AD P AD P
> .
UP / DOWN go to the next/previous I/O number which is different from "0 00-0"
Note that you have to enter the address again if you want to change the Invert-
Bit.
Description of display:
30 55
Date:DRAFT0
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 31 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
31 55
Date:DRAFT0
3.3.3 Setup Allowed Mask Menu M-1-3-3
This function is used to setup the Floor Table masks. Four different Allowed Masks are
available:
32 55
Key Handling for all Allowed Masks
Date:DRAFT0
The following keys can be used in all Allowed Masks:
33 55
Date:DRAFT0
3.3.3.1 Enable Mask M-1-3-3-1
Description of display:
TCBC
For TCBC the R-Bit is not necessary. The handling of Short Landings is completely done by
the Drive.
TCBC
LCB2, TCB
Drivetypes with learnrun (OVF20, OVFWW) require the setting of the R-Bit only in 1LS and
2LS.
LCB2, TCB
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 34 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
34 55
Date:DRAFT0
3.3.3.2 Cut Call Mask M-1-3-3-2
Description of display:
35 55
Date:DRAFT0
3.3.3.3 Card Reader Mask M-1-3-3-3
LCB2
The description for this mask is only valid for LCB2 software versions since GAA30082CAA
LCB2
Description of display:
36 55
Date:DRAFT0
3.3.3.4 SHO and WCO Masks M-1-3-3-4
LCB2
The description for this mask is only valid for LCB2 software versions since GAA30082CAA
LCB2
This mask is used to setup the Shabat Operation and Wild Car Operation.
The following functions can be set for each floor, separately for SHO and WCO:
Select at which floor the car will stop
Select which door will be opened
Description of display:
37 55
Date:DRAFT0
3.3.4 Setup Position Indicator Menu M-1-3-4
This menu defines the display of the Position Indicator at each floor.
Pos.Ind. new
at: L 00 =10 > .
0 … 9 enter a code number to program the Position Indicator (see list below)
Description of display:
Description of codes:
38 55
Date:DRAFT0
3.3.5 Setup DCS-Run Menu M-1-3-5
The Door Check Sequence (DCS) - Function is a safety feature for MCS controllers. It in-
sures that all hoistway door contacts are installed correctly and will open the safety chain
when a door opens.
Until the Door Check Sequence is finished successfully it is only possible to move the car in
inspection mode. Normal runs are disabled.
to start DCS .
press ENTER .
The following error messages can be displayed before the DCS run is started:
DCS Start Error: The car is in 1LS, but not in the doorzone.
Leave 1LS! . Leave 1LS or move into DZ.
39 55
Description of display:
Date:DRAFT0
Display description values
1 - moving direction - not moving
12 3 4 5 u moving up
-00 DW:clsd <>][ d moving down
open front door. 2 00 floor position ** unknown position
6 00-31 current floor number
3 DW:clsd status of DW input and DW:clsd landing door is closed
DS contact dw:opnd landing door is opened
4 <> front door state ][ fully closed
<> opening
[] fully opened
>< closing
5 ][ rear door state ][ fully closed
<> opening
[] fully opened
>< closing
6 open action open front door
front open rear door
door check DW input
close front door
close rear door
moving to bottom
up to next floor
error text see table below
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 40 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
40 55
The following error messages can be displayed during the DCS run:
Date:DRAFT0
Error Message Reason
Front Door Error landing door contact is not opened while front car door is opened
Rear Door Error landing door contact is not opened while rear car door is opened
aborted by ENTER The key ENTER has been pressed; DCS is aborted.
DW not closed car door is closed but landing door contact is open
Door opening Err door could not be opened within 20 seconds
Position Error The calculated position is higher than TOP.
Door closing Err door could not be closed within 20 seconds
SE is missing! safety chain is closed but SE is low.
41 55
Date:DRAFT0
3.3.6 Setup ELD Menu M-1-3-6
The ELD – function is used to define the ”Customer Message” of the OTIS 2000-ELD
(CPI-11).
For each floor the Customer Message can be
displayed (Floor-Mode)
modified (Edit-Mode and Default-Mode)
or stored into EEPROM (Store-Mode).
Overview
1
M -1 -3 -6
5
CLEAR send Customer Messages to ELD
Floor-Display
2
ENTER CLEAR
OFF
Edit-Display Default-Display
CLEAR
ENTER
3 OFF
ENTER CLEAR
Store-Display
4
ENTER
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 42 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
42 55
Floor-Display:
The following keys can be used: Date:DRAFT0
CLEAR All messages will be sent to the ELD if you have been in the Store-Display.
Floor-Display:
Description of display:
43 55
Edit-Display:
The following keys can be used: Date:DRAFT0
UP / DOWN Change the cursor position within the customer message. The selected position
is marked by a blinking "?".
GOON / GOBACK Change the Selected character. The range of available characters is defined by
the active Edit-Mode.
Edit-Mode "mov":
Move the displayed Customer Message to the left or right. This is an easy way
to center the message on the ELD.
1 … 9 Skip through the character set using the selected step width (Key-No.)
0 … F Edit-Mode "HEX":
Input 2-digit-HEX-code to enter a new character
CLEAR Back to the Floor-Display. The current Customer Message will be buffered so
that you can change the Edit-Mode without loosing your changes.
Edit-Display:
Description of display:
44 55
Store-Display:
The following keys can be used: Date:DRAFT0
Store-Display:
Description of display:
45 55
Default-Display:
The following keys can be used: Date:DRAFT0
0 … 9 Two digits input to select the Default Message by entering the List-No.
ENTER Transition back to Edit-Display. The desired Default Message will be buffered.
Default-Display:
Description of display:
46 55
List of Default Messages
Date:DRAFT0
No. ENG GER ITA
0 LOBBY ERDGESCHOSS TERRANO
1 BASEMENT KELLER SOTTERRANEO
2 PENTHOUSE DACHTERASSE ATTICO
3 FLOOR ETAGE PIANO
4 RECEPTION EMPFANG RICEZIONE
5 EXIT AUSGANG USCITA
6 GARAGE TIEFGARAGE POSTEGGIO
7 SECRETARY SEKTRETARIAT SEGRETERIA
8 RESTAURANT RESTAURANT RISTORANTE
9 CAFETERIA KAFFEESTUBE CAFFETERIA
10 GARAGE PARKHAUS POSTEGGIO
11 POOL SCHWIMMHALLE PISCINA
12 SAUNA SAUNA SAUNA
13 DOCTOR ARZT DOTTORE
14 0 123 456 789 0 123 456 789 0 123 456 789
15 : . () <> / -, & ’ : . () <> / - , & ‘ : . () <> / - , & ‘
16 ABCD EFGH IJKL ABCD EFGH IJKL ABCD EFGH IJKL
17 MNOP QRST UVWXYZ MNOP QRST UVWXYZ MNOP QRST UVWXYZ
18 Ä Á Å Ç Ø Ö Æ Ä Á Å Ç Ø Ö Æ Ä Á Å Ç Ø Ö Æ
19 empty string
HEX-CODE Table
ASCII HEX ASCII HEX ASCII HEX ASCII HEX ASCII HEX
Blank 20 0 30 A 41 N 4E Ä 80
& 26 1 31 B 42 O 4F Á 81
( 28 2 32 C 43 P 50 Å 82
) 29 3 33 D 44 Q 51 Ç 83
, 2C 4 34 E 45 R 52 A- 84
- 2D 5 35 F 46 S 53 -E 85
. 2E 6 36 G 47 T 54 Ø 86
/ 2F 7 37 H 48 U 55 Ö 87
: 2A 8 38 I 49 V 56
< 3C 9 39 J 4A W 57
> 3E K 4B X 58
L 4C Y 59
M 4D Z 5A
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 47 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
47 55
Date:DRAFT0
3.4 Tools Functions
These are a couple of functions for additional diagnostic.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 48 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
48 55
Date:DRAFT0
3.4.1 Search IO M-2-1
This functions finds all I/O-Numbers which are programmed to a specific RSL address.
Description of display:
Display description values
1 ? status indicator ? waiting for input (ENTER)
1 ! searching
Search-IO ? 2 04 Address to be
Adr: 04 / Pin: 1 searched for
2 3 3 1 Pin/Bit to be
searched for
1 1 ? status indicator ? waiting for input (ENTER
Search-IO ? ! searching
>04 1< IO: 0001 2 04 1 Addess and Pin to be 04 1 … 63 4
2 3 searched for
3 0001 I/O-number which is 0000 - 9999
programmed for this
Address/Pin
49 55
Date:DRAFT0
3.4.2 Erase IO M-2-2
This function completely erases the I/O-Setup in the E2PROM.
Erase IO_Part.
n=0 y=1 / Enter.
1 Erase IO_Part. 0 & ENTER leave menu; the setup will not be erased
n=0 y=1 / Enter.
2 Erase IO_Part. 0 & ENTER leave menu; the setup will not be erased
n=0 y=2 / Enter.
After calling this function all RemoteStation-Adresses will have been deleted and all I/Os
will be inactive:
50 55
Date:DRAFT0
3.4.3 Setup Inst M-2-3
This function completely erases the Installation Parameter Setup in the E2PROM.
Description of display:
Setup Install ?
n=0 y=1 / Enter.
1 Erase IO_Part. 0 & ENTER leave menu; the setup will not be erased
n=0 y=1 / Enter.
2 Erase IO_Part. 0 & ENTER leave menu; the setup will not be erased
n=0 y=2 / Enter.
After calling this function all parameters have been set to the Default-value as indicated in
the List of Installation Parameters.
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 51 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
51 55
Date:DRAFT0
3.4.4 Setup Door M-2-4
LCB2, TCB, HCB
This function allows you to change from predefined Door Operators (DOOR=0-10) to Ge-
neric Door Operator (DOOR=11) without programming each parameter separately.
Description of display:
display keys description
Enter a doortype as listed in the List of Installation Pa-
1 Which door type? 0 … 9 rameters for parameter DOOR.
front > .
ENTER confirm
ENTER confirm
Now you can setup DOOR=11 (or REAR=11) without changing the behaviour of the soft-
ware.
LCB2, TCB, HCB
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 52 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
52 55
Date:DRAFT0
3.4.5 Show History M-2-5
TCB
With this menu you can store the commands of the coded interface between TCB and OVF-
WW, so that you can view them later.
You can start and stop the storage with the Service Tool. Note that the storage will stop
automatically when the memory is full.
Engineering only.
Description of display:
display keys description
1 press ENTER to. ENTER The storage will begin when you press ENTER.
start storage.
2 Storage running. ENTER All commands of the coded interface are stored until the
ENTER to stop . buffer is full or ENTER is pressed again
3 Buffer is full!. ENTER Buffer is full. No more commands can be stored. Press
ENTER to cont.. ENTER to view the commands which have been stored.
The first line displays the state of some inputs, while the
4 01: DFC ip DZ . GOON / second line displays the status on the coded interface
lr DR rn SC lns. (either from TCB or from MCB)
GOBACK
or
02: DFC ip DZ . One entry is stored whenever one of the signals is
(WT ) . changing. Use GOON/GOBACk to view the
next/previous entry.
TCB
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 53 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
53 55
Date:DRAFT0
3.4.6 Smart Button Program M-2-6
LCB2
This menu is used to program a single Smart Button. Make sure that the elevator is
switched to ERO and a new unprogrammed Smart Button is connected to the RSL.
Description of display:
4 Press Button for press the press the Smart Button for at least 3 seconds to program
min 3 Seconds . Smart Button the address into the Button.
LCB2
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 54 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
54 55
Date:DRAFT0
3.4.7 Smart Button Test M-2-7
LCB2
With this menu a single unprogrammed Smart Button can be tested. Make sure that the
elevator is switched to ERO and a new unprogrammed Smart Button is connected to the
RSL.
The display shows the state of the input and the output of the Button:
SB TEST AT ADR 4
IN:off OUT:off.
Different from the normal TTL handling the output is toggled each time the Smart Button is
pressed (press to switch TTL on, press again to switch TTL off).
LCB2
No.: GAA26800KA IV a_FC1
Field Component Manual
OTIS SCN: GAA30081AAB
Rev.: V1.1
Service Tool User’s Guide
Engineering Center Page: 55 / 55
Berlin MCS – TCBC
Date: 18-Jan-02
Service Tool Manual
: ???-Sep-2001
55 55
Date:DRAFT0
3.4.8 Operate Memory M-2-9
This menu allows to access the memory addresses of the board.