You are on page 1of 1

BASIC LOAD CASE:

Load Case Description


1 Dead
2 Empty
3 Operating In the Vendor Drawing Wet weight is given
4 Test I'm Considering Operating and Hydro weight same as Wet Weight
5 Wind
6 Empty Seismic
7 Operating Seismic

16.2 ALLOWABLE LOAD COMBINATION:

Allowable
Load Comb
Empty Operating
Dead Empty Operating Test Wind
Seismic Seismic

1 1 1
2 1 1
3 1 1
4 1 1 0.6
5 0.9 0.9 0.6
6 1 1 0.15
7 1 1 0.7
8 0.9 0.9 0.7

16.3 ULTIMATE LOAD COMBINATION:

Empty Operating
Ultimate Dead Empty Operating Test Wind
Seismic Seismic
Load Comb
1 1.4 1.4
2 1.4 1.4
3 1.4 1.4
4 1.2 1.2 1
5 0.9 0.9 1
6 1.2 1.2 0.25
7 0.9 0.9 1
8 1.2 1.2 1

WIND LOADS:
Risk Catgeory III
Exposure Catgeory C
Basic Wind Speed 153mph
With 3Sec Gust wind speed at 10 m
Exposure Coefficient,Kzt = 1
Directionality Factor,Kd = 0.95

SEISMIC LOADS:
Risk Catgeory III
Importance Factor 1.25
Seismic acceleration factor for short period , Ss : 0.065g
Seismic acceleration factor for one second , S1 : 0.021g
Design Short Special Response Acceleration SDS : 0.069g
Design Long Special Response Acceleration SD1 : 0.034g

Pile Type
Minimum 36" Diameter Straight drilled Shaft