Shutdown SIS
Previous Screen
Systems Operation
PL1000E Communication ECM
Media Number -RENR8091-03 Publication Date -01/09/2007 Date Updated -06/09/2007
i02808691
The following instructions cover both the setup requirements for the PL1000E Communication ECM and the single
Personal Computer (PC) that will connect to it. The PC instructions are different for the specific operating system
used.
Illustration 1 g01415005
PL1000E configuration
Configuring a PL1000E Communication Module to Work on a Non-DHCP network
Perform the following steps in order to configure a PL1000E Communication Module to work on a network that
does not have Dynamic Host Configuration Protocol(DHCP).
1. Connect a computer with Caterpillar Electronic Technician (Cat ET) or Caterpillar Communications Tool Kit
to a PL1000E Communication ECM either by using a "Comm Adapter II" or the "ECA Service Port (serial
port 3)" on the PL1000E.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 2 of 11
Illustration 2 g01401042
3. Once Cat ET is started and the selected device is the PL1000E, click on the "Configuration Screen" or press
the F5 key.
Illustration 3 g01401047
4. Once the configuration screen loads, change the Dynamic Host Configuration Protocol (DHCP) Enable Status
to disabled by highlighting it and clicking "Change".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 3 of 11
Illustration 4 g01178247
Illustration 5 g01401149
7. Highlight the Network Default Gateway Internet Protocol (IPv4) Address entry and click "Change".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 4 of 11
Illustration 6 g01401274
8. Enter the address of the default gateway, if applicable, in the form of "1.0.0.0" and click "OK".
Illustration 7 g01401150
10. Highlight the "Internet Protocol (IPv4) Network Mask" entry and click "Change".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 5 of 11
Illustration 8 g01401283
11. Enter the "Subnet" mask value of "255.255.255.0" and click "OK".
Illustration 9 g01401291
13. Highlight the "Internet Protocol (IPv4) Address"" entry and click "Change".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 6 of 11
Illustration 10 g01401295
14. Enter the IP address in the form "192.168.159.201" and click "OK".
16. In order to make the PL1000E changes effective, turn the key switch to the OFF position, then turn the key
switch back to the ON position. The PL1000E is ready for direct connect use.
Perform the following steps in order to configure a Windows based PC that is not on a network to access the
PL1000E.
Note: A crossover ethernet cable is required in order to directly connect the network adapter port (RJ-45) of
the PC to the network adapter port of the PL1000E without the use of a hub or switch.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 7 of 11
Illustration 11 g01404022
Illustration 12 g01404026
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 8 of 11
Illustration 13 g01404032
7. Click "OK".
Illustration 14 g01404035
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 9 of 11
Illustration 15 g01404038
11. In the Local Area Connection Status window click "Properties" (14).
Illustration 16 g01404040
12. In the box that is titled "This connection uses the following items:", scroll down the screen and then select
"Internet Protocol (TCP/IP)" (15). Refer to Illustration 17.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 10 of 11
Note: There is a possibility that an ethernet adapter card has not installed on a Windows based PC that is not
networked. If an ethernet adapter card has not installed, then the item, "Internet Protocol (TCP/IP)", will not
appear in the list. In order to proceed with this type of connection, an ethernet adapter card must be installed
or a different PC that is equipped with an ethernet adapter must be used.
Illustration 17 g01404064
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 29/01/2008
Media Search - RENR8091 - PL1000E Communication ECM Page 11 of 11
Illustration 18 g01404041
17. Enter the IP address in the form "192.168.159.10". Enter the "Subnet" mask as "255.255.255.0".
19. Click "OK" on the Local Area Connection Properties window in order to close the window.