 30cm standard-C.

O
 150 cm maximum height is 2m
 12 in or 30 cm minimum (convenience outlet)
 14 ft. (Poste) minimum Height
 10-12 feet standard height with tolerance ENTRANCE CAP
 6 feet not less than PANEL BOARD (from the ground)
 6 feet from the panel board
 Estimation
 (EMT= 40+45=85cm=850mm=0.85m)
 Flexible Hose
 30(m) (4) + 30 (4) + 25 (4)
=120+120+100=340
=3,400mm=3.4m
 Wire #14 AWG-2.0mm² THW stranded for L.O
=25(6) +30(6) +30(8)
=25(6) +30(6) +30(8)
=150+180+240=570cm=5.7m
 Wire #12 AWE or 3.0mm² THW stranded for C.O
=30(2) +30(2) +25(8)
=60+60+200=320m=3.2m
 Incandescent bulb 40 watts
 10x10=100Ω reading
 Voltage=
 750 maximum reading
 10 minimum reading
 ACU=750-250 (dapat nakapatong ang selector)
 250-750=the needle should always on this reading
 215 volts reading of convenience outlet
 750-reading 0 to 10 red color
Means 0 to 1000v= 200vts
(bcv=.25v to 1000v)
1. What is the minimum size of wire service entrance conductor?
Ans: #8 AWG
2. What is the type of raceway or service entrance conduit is usually use?
Ans: RSC=rigid steel conduit

Kinds of Raceway
 RCS-rigid steel conduit
 IMC-immediate metallic conduit
 EMT-electric metallic tube
 PVC-
 Flexible
 USA Wire
 RED=HOT
 BLACK=O
 WHITE=NEUTRAL
 GRAY=GROUND
 GREEN=EQPT. GROUND
 3 Phase System
 PHASE A-RED
 PHASE B- WHITE
 PHASE C- BLUE

 PHIL. WIRE
 L1 & L2-BLACK
 GROUND-GRAY OR WHITE
 EQPT. GROUND-GREEN

 NEMA-3R=National Electrical Manufacturing Association


 PPE=Personal Protective Equipment
 Insulator= high resistance
 Conductor= low resistance
 Behind the voltage=inductive
 Leading the voltage=capasitive
 Floor plan 1/50=6m=3m
 Green Red Orange=523=52
 EMT Bending- Thin wall pipe bender
 RSC Bending- Thick wall pipe bender
 Every industry consume-kilo watt/hour
 Transformer=lower than
 Explosion proof-sa loob ng pagsabog walang maapektuhan na ibang parte
 Kilowatt= a unit of power which is equivalent to 1000w
 Insulator= material used to cover electric were which may be made from plastic
(low resistance)
 Metallic Conduit-metal raceway that was classified into four
 D=talk to the operator to inform the problems
 D=rubbing rod
 General purpose-Transmit shock to the user safety measure
 Objective prevatire- keep the machine in a good condition
 Personal PPE-P A&C
 Main reason-B overload
 Fuse problem
 Protective device- circuit breaker
 Rough edges-reamer
 Friction type- to protect rubber tape
 Metal conduit- reduce shock hazard
 What type of switch?-3 way control one lamp 2 location
 Utility company- certificate installation
 Overhead service conductors-service draft
 Always make sure the- defective tool may have tools that is safe
 Lighting height (actual size)-2.0meters
 The light supply are often-when dealing
 Kelan dapat gawin-when the_is not in use
 Ang modem kapag may sira
 Transformer-high or low voltage
 Before you can-read normal operation
 Maximum of conduit-40% allowance space
 Has the highest capacity-50mm² wire size
 Silver instead of copper – A cost
 Race way ½ bending-90²
 Ohm-infinity open circuit
 PEC-180VA
2 gang c.o-equivalent outlet
Lights-100 VA
 If you measure diameter you should use-c.wire gauge
 Where would be an input-primary widang 220&110//output=secondary widding
 Before installation-electrical wiring permit
 3000 VA-35%
 Insulation measurement instrument resistance-megger
 Wire has lower-resistance
 Lowest resistance- #4 wire
 Best insulator in electricity-mica(Seavely)
 Best conductor in electricity-silver
 General load for light-24 VA
 Electrical to mechanical- motor
 Proper position c,o box-horizontal
 Size of wire of feeder allowed by the PEC 2.0 or weather head-8.5 mm² minimum
 3 location=2.3 way & 4-way
 PPE-electrical plan
 AF=ampere frame
 Standard measure street used in title block-40 mm
 Means for AT-ampere trig
 Example of semi-conductor device- transistor/diode
 Best method in generating electricity- magnetism
 Electrical plan not content of electrical plan –raceway layout
Battery-chemical
Generator-magnetism/friction
 Parallel circuit =series-pressure
 In series circuit is constant!=current parallel circuit/voltage
 Circuit C. O (Planning)-20 AT
 40 AWG minimum 1 box standard=150meters////1 box flexible=100m
 Shortened wire measure_ ohm=0 ohms
 Unit commonly use in Stranded wire=mm²
 Unit commonly use in Solid wire=mm
 Minimum wire for Service wire=#10mm² minimum (lowest)
 Service entrance=3 #8mm² minimum wire (MERALCO)
 Service ground conductor=White/natural gray
 Equipment ground= green
 After finished inspection insulation PPE= Practical Test
 Used while in insulation practical=gloves
 Common unit capacitor=KVAR
 KVAR= Kilovolts Ampere Reactance
 Practical building wiring which is first and foremost important to be
considered=personal safety
 PPEC minimum Standard for C.O= #3.5 mm²
 Practical which is not essential of circuit=voltmeter & ammeter
 It is minimum standard for the inside box for repair= 6meters
 Atom which in number of electron beyond consider proper what is standard given
of electron= free electron
 It is the no. of electron copper= B 29
 Minimum height of service draft of a building= 10ft
 MERALCO to service entrance= 14ft
 PPE (when you worked 5 meters=safety belt or body harness high
 Ohm law=total resistance of 2 & 5 in parallels
Computation
(5Ω+5Ω)/2=2.5Ω
 What do you call the meter group= meter bank
 3 example raceway=EMT & PVC & IMT
 Importance of growth= Personal safety
 3 example of conductor= copper, silver, iron
 Method of maintenance= lubrication, cleaner, calibrator
 Explain the operation of pre-heated light lamp
 What is the difference pre-heated=have started//rapid starter= no starter
 What is the allowable voltage=1-3% voltage draft