Project PHB KUALA TERENGGANU Calcs.

By

Location BANDAR KUALA TERENGGANU Checked

Date 10-MAR-2021 Page 10 of 16

References Calculations

9 .1 Verification on Anchor Bolt Tension Design


( M12 x 100 FBN II gvz @ C25 )

Steel Failure NRd,s = 29.7 kN

Anchor Design Resistance NORd,p = 17.6 kN

Influence of Conc Strength fbN = 1.0

Pull-out Failure NRd,p = NORd,p . fbN


= 17.6 kN

Conc Cone Failure NRd,c = NORd,c . fbN . fs1 . fc1


= 17.6 x 1 x 0.9 x 1
= 15.8 kN

Conc Splitting Failure NRd,sp = NORd,c,sta . fbN . fs1,sp . fc1,sp . fh


= 17.6 x 1 x 0.75 x 0.91 x 1.16
= 13.9 kN

Lowest Value NRd,s = 13.9 kN

From Pg. 09 of 16 Design Tension Force NtEd = 3.9 kN

NtEd
Verify
NRd,s
= 0.28 < 1.0 Acceptable

9 .2 Verification on Anchor Bolt Shear Design


( M12 x 100 FBN II gvz @ C25 )

Steel Failure VRd,s = 25 kN

VSd,s = 3.19
Shear Component of Load
Acting on Single Anchor at VSd,s
Steel Resistance = 0.13 < 1.0
V Rd,s
Pryout Failure VRd,cp = NRd,c,sta .K
K = 2.3 = 15.84 x 2.3
= 36.4 kN

V Sd,cp = 3.19
Shear Component of Load
Acting on Single Anchor at VSd,cp
Pryout Resistance = 0.09 < 1.0
V Rd,c

Edge Dist. Resistance VORd,c = 12.8 kN

Influence of Conc Strength fbV = 1.0

Influence of Load Direction fα,V = 1.0

Conc Cone Failure VRd,c = VORd,c . fbV . fα,V . fs1,V . fc2,V . fh,V . fm
= 12.8 x 1 x 1 x 0.77 x 0.91 x 1.16 x 1
= 10.4 kN

V Sd,c = 3.19
Shear Component of Load
Acting on Single Anchor at V Sd,c
Concrete Edge Resistance = 0.31 < 1.0
V Rd,c

VSd,s VSd,cp VSd,c VSd Decisive Design Proof in Shear -


; ; = 0.31 < 1.0
VRd,s V Rd,c V Rd,c VRd Highest Value

NtEd VSd
Tension + Shear
NRd,s + VRd
= 0.59 < 1.0 Acceptable