You are on page 1of 3

DCC6262 Attchmnt # 2

Jun-19 Project : ROOF TRUSS DESIGN


NBW Element Design
: Bolted Member Subjected to Compression Load 24.50 kN
Design sheet : 1
REF CALCULATION OUTPUT

COMPRESSION LOAD MEMBER : F1-2 & F8-6

Ned = 24.5 kN
Fe = 430 N/mm²
Fy = 275 N/mm²
Lcr = 1.73 m

Nethercot Ned / fy = 0.89 cm²


< 89.1 mm²
24500 / 275

Try size 244.5 x 12 CHS (A = 87.7 cm² )

E= 210000 N / mm² Lcr = 1730 mm


I= 5940 cm⁴ A = 8770 mm²
d= 244.5 mm t = 12 mm

Material properties
EN 1993 -1-1
Table 3.1 Steel grade = S 275 (EN 10025-2) t < 40mm
Tab 2.1 Ɣ M0 '= 1.0 ɣ M1 '= 1.0
Ag = 8770 mm²

Table 6.2 Hollow section : hot finished :

S 275 Buckling Curve = a


Table 6.1 Imperfection factor, α = = 0.21
pg 57

Classification of Section

EN 1993-1-1 ɛ = √ ( 235 / fy ) = 0.92

Tab 5.2 d/t= 244.5 / 12 = 20.4


Sheet 3 50 ε² =50 x 0.85 = 42.7
pg 44
d/t < 50 ε² Class 1
20.4 42.7
DCC6262 Attchmnt # 2
Jun-19 Project : ROOF TRUSS DESIGN
NBW Element Design
: Bolted Member Subjected to Compression Load 24.50 kN
Design sheet : 2
REF CALCULATION OUTPUT

Design Compression Resistance Nc,Rd


EN 1993 -1-1
Cl 6.2.4
Eq 6.10

Eq 6.5 Nc,Rd = Afy / ƔM0 = 8770 x 275 / 1


= 2411750 N = 2412 kN

Ned < Nc,Rd Satisfied


24.5 2412

Design Buckling Resistance, Nb, Rd

Ncr = π² E I / Lcr²
= 9.86 x 210000 x 59400000
2992900
= 41093471.35 N
= 41093.47 kN

EN 1993-1-1
Cl λ¯ = √( 8770 x 275 / 41093471 )
6.3.1.2 = 0.2423

Φ = 0.5 [ 1 +1 + 0.21 ( 0.2423 - 0.2 ) +)'+( 0.05869 )]


= 0.534

χ = 1
0.534 +√ 0.284923 - 0.058689 )
= 0.99 < 1
DCC6262 Attchmnt # 2
Jun-19 Project : ROOF TRUSS DESIGN
NBW Element Design
: Bolted Member Subjected to Compression Load 24.50 kN
Design sheet : 3
REF CALCULATION OUTPUT

Nb, Rd= 0.99 x 8770 x 275


1
= 2389238 N
= 2389 kN

Ned < Nb, Rd Satisfied


24.5 2389

THE CHOSEN SECTION IS ACCEPTABLE


244.5 x 12