You are on page 1of 3

ETABS 2016 16.1.

0 License #*1DQ43FYAJFWHCLM

Connection Design: C740-BP


Units: kip-in
Story: CUBIERTA BAJA
Design Code: AISC 360-10

W = 685,8 mm

S2 = 535,4 mm
H = 660,4 mm

S1 = 560,8 mm

Column Base Plate Connection

Summary of results

Design Check Type D/C Ratio Result Reference


1 Concrete bearing strength 0,018 Passed
2 Base plate thickness 0,226 Passed

Material Properties
Column HP18X204 STEEL F y = 50 ksi F u = 65 ksi
Base Plate STEEL F y = 50 ksi F u = 65 ksi

Geometric Properties
Column HP18X204 t w = 1,13 in d = 18,3 in t f = 1,13 in b f = 18,1 in

Bolts, Plate & Weld


Anchor rod Diameter = 0,98425 in Head/Nut type = Square Material = ASTM F1554 Grade36
Base Plate Width = 27 in Height = 26 in Thickness = 0,98425 in

Pedestal
Dimensions Width = 30,94 in Height = 29,94 in

Design Calculations

MODELO ESTACION SERVICIO ZONA


6 CON VIENTO 45X45 DIAGONALES Page 1 of 3 15/06/2017
ORGANIZADAS.EDB
ETABS 2016 16.1.0 License #*1DQ43FYAJFWHCLM

Design calculations of base plate for combined moment and compression

Design Provision = LRFD

Load Combination = ENVOLV

Pu = - 23,31092 kips, Mu = - 0,05598 kip - in

Base plate area

N = Max [ Nmin , ( d + 2x3 in ) , [ d + 2 ( L eh + c ) ] ]

N = Max [ 9,84 , ( 18,3 + 2x3 in ) , [ 18,3 + 2 ( 2,46 + 1,48 ) ] ] N = 27 in

B = Max [ Bmin , ( b f + 2x3 in ) , { b f + 2 ( L ev + c ) }]

B = Max [ 9,84 , ( 18,1 + 2x3 in ) , [ 18,1 + 2 ( 2,46 + 1,48 ) ] ] B = 26 in

S1 = N - 2 L eh S1 =27 -2 ( 2,46 ) S1 =22,08 in

S2 = B - 2 L ev S2 =26 -2 ( 2,46 ) S2 =21,08 in

Base plate dimension ( B inch x N inch ) = 26 x 27

A1 = B · N A1 = 26 · 27 A1 = 702 in 2

A2 = ( B + 2a ) ( N + 2b ) A2 = ( 26 + 2 · 1,97 ) ( 27 + 2 · 1,97 ) A2 = 926,16 in 2

e and e crit

Mu 0,05598
e= e= e = 0,0024 in
Pu 23,31

A2
f p ( max ) = ϕ 0.85 fc ' Min ( 2, A1 )
926,16
f p ( max ) = 0,65 · 0.85 · 2,99 Min ( 2, 702 ) f p ( max ) = 1,9 ksi

kips
q max = f p ( max ) B q max = 1,9 · 26 q max = 49,28
in

N Pu 27 23,31
e crit = - e crit = - e crit = 13,26 in
2 2 q max 2 2 · 49,28

e is less than e crit, design the base plate with small moment

Concrete bearing strength

Y = N - 2e Y = 27 - 2 · 0,0024 Y = 27 in

Pu 23,31 kips
q= q= q = 0,86352
Y 27 in

q is less than q max

q 0,86352
D / C Ratio = D / C Ratio = D / C Ratio = 0,01752
q max 49,28

MODELO ESTACION SERVICIO ZONA


6 CON VIENTO 45X45 DIAGONALES Page 2 of 3 15/06/2017
ORGANIZADAS.EDB
ETABS 2016 16.1.0 License #*1DQ43FYAJFWHCLM

D / C Ratio is less than 1, concrete is safe in bearing

Base plate thickness

At bearing interface

N - 0.95d 27 - 0.95 ( 18,3 )


m= m= m = 4,81 in
2 2

B - 0.8 b f 26 - 0.8 ( 18,1 )


n= n= n = 5,76 in
2 2

Pu 23,31
fp = fp = f p = 0,03321 ksi
B·Y 26 · 27

Y is greater than max ( m,n ) so

fp
t p1 (min ) = 1.5 max ( m,n )
Fy

0,03321
t p1 (min ) = 1.5 max ( 4,81,5,76 ) t p1 (min ) = 0,22268 in
50

t p ( min ) 0,22268
D / C Ratio = D / C Ratio = D / C Ratio = 0,22624
t 0,98425

The required thickness for base plate is 0,22268 inch

MODELO ESTACION SERVICIO ZONA


6 CON VIENTO 45X45 DIAGONALES Page 3 of 3 15/06/2017
ORGANIZADAS.EDB