Professional Documents
Culture Documents
1KHW002569BE System Test Report ETL600R4 Reichle
1KHW002569BE System Test Report ETL600R4 Reichle
Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© 2012 ABB
Project : …………………………..
Station : …………………………..
Link : …………………………..
Equipment N° : …………………………..
Direction : …………………………..
Rev. ind:
Type des. Part no.
No. of p.
Prep. Hans Benninger / PSND 2012-04-11 Doc.kind
Appr. M. Israel / PSND2 2012-06-26 Title System Test Report ETL600R4 17+
Resp.dept. PSNEX
Doc. no. Lang. Rev. ind. Page
REVISION
Rev. Page (p.) Description Date
ind. Chapter (c.) Dept./Init.
A c. B.2 Measurement at MCB 2012-05-15 / Be
B c. B.10.4 Default position changed to T20 2012-05-22 / Be
B.1 General
Left Right
B.2 Check power supply B5LD
B.5 Transmitter
E5TC E5TH
B.5.1 Programming of Tx RF filter
Refer to 1KHW002585 Mark if not programmed
1 [ ] [ ]D
Tuning Instructions for ETL600R4
Tx RF Filter on E5TH/C
Bandwidth = 4 kHz E5TH/E5TC Refer [ ] [ ]D
Bandwidth = 8 kHz E5TH/E5TC to [ ] [ ]D
Bandwidth = 16 kHz E5TH/E5TC document [ ] [ ]D
Bandwidth = 32 kHz E5TH/E5TC 1KHW002585 [ ] [ ]D
Center frequency E5TH/E5TC fTx=________ kHz
1
As the channel frequencies were not known at test time, the system was tested with temporarily inserted factory-owned
filter(s), programmed and tuned to a standard frequency and bandwidth.
E5TC E5TH
B.5.3 Tune Tx RF filter Mark if not configured: [ ]
2
Mark if not tuned : [ ] [ ]D
Dialog box 'Tune Tx RF filter' E5TH, E5TC Refer to doc. [ ] [ ]D
1KHW002585
B.6 Receiver
2
As the channel frequencies were not known at test time, the system was tested with temporarily inserted factory-owned
filter(s), programmed and tuned to a standard frequency and bandwidth.
Doc. no. Lang. Rev. ind. Page
B.7 Equalization
Ch 1 Ch 2 Ch 3
B.7.1 Measure frequency response Mark if not configured: [ ] [ ] [ ]
B.10.2 Outputs
Enforce action for relay 1 Terminal, Refer G4AI N02 N08 N14 N20
REL1 close/open (T…/17) – (T.../18) programming N24 N30 N36 N42 N48 N54 N60
Check LED REL1 LED REL1 ON [ ] [ ] [ ] [ ] [ ] [ ] [ ]
Enforce action for relay 2 Terminal, Refer G4AI N02 N08 N14 N20
REL2 close/open (T…/19) – (T.../20) programming N24 N30 N36 N42 N48 N54 N60
Check LED REL2 LED REL2 ON [ ] [ ] [ ] [ ] [ ] [ ] [ ]
TPE1 TPE2
Command A Mark if not configured: [ ] [ ]
Terminal: Refer HMI600
Tx command A (T20/1) – (T20/2) [ ] Mean value
(T…/...) – (T.../…) [ ]
T0 ms ________ ________
Rx command A (T20/9) – (T20/10) [ ]
(T…/...) – (T.../…) [ ]
TPE1 TPE2
Command B Mark if not configured: [ ] [ ]
Terminal: Refer HMI600
Tx command B (T20/3) – (T20/4) [ ] Mean value
(T…/...) – (T.../…) [ ] ms
T0 ________ ________
Rx command B (T20/11) – (T20/12) [ ]
(T…/...) – (T.../…) [ ]
TPE1 TPE2
Command C Mark if not configured: [ ] [ ]
Terminal: Refer HMI600
Tx command C (T20/5) – (T20/6) [ ] Mean value
(T…/...) – (T.../…) [ ] ms
T0 ________ ________
Rx command C (T20/13) – (T20/14) [ ]
(T…/...) – (T.../…) [ ]
TPE1 TPE2
Command D Mark if not configured: [ ] [ ]
Terminal: Refer HMI600
Tx command D (T20/7) – (T20/8) [ ] Mean value
(T…/...) – (T.../…) [ ] ms
T0 ________ ________
Rx command D (T20/15) – (T20/16) [ ]
(T…/...) – (T.../…) [ ]
Measure Output level. Feed into rem. equ. at Configured Output dBm N02 N08 N14
Feed 800 Hz with configured terminal 8a-8b level ±1 dB (600 ) N24 N30 N48
input level of remote Measure at terminal (Def.: -7.0 dBm) [ ] [ ] [ ]
subscriber (Def.: 0.0 dBm). 8a-8b
Test Ringer: Feed ringing Feed into rem. equ. at Subscriber must N02 N08 N14
voltage (25 VAC, 25 Hz, R = terminal 7a-7b ring N24 N30 N48
2.2 k) into remote PAX 2- [ ] [ ] [ ]
Wire
Measure Output level. Feed into rem. equ. at Configured Output dBm N02 N08 N14
Feed 800 Hz with configured terminal 7a-7b level ±1 dB (600 ) N24 N30 N48
input level of remote Measure at terminal (Def.: -7.0 dBm) [ ] [ ] [ ]
PAX.(Def.: 0.0 dBm) 8a-8b
Test Ringer: Activate at Remote equ. Subscriber must N02 N08 N14
Activate M-WIRE of remote at terminal 4a-4b ring N24 N30 N48
Pax 4-wire. [ ] [ ] [ ]
Measure Output level. Feed into rem. equ. at Configured Output dBm N02 N08 N14
Feed 800 Hz with configured terminal 1a-1b level ±1 dB (600 ) N24 N30 N48
input level of remote Measure at terminal (Def.: -7.0 dBm) [ ] [ ] [ ]
PAX.(Def.: -3.5 dBm) 8a-8b
Test E-Wire: Terminal 3a-3b E-Wire must toggle N02 N08 N14
Toggle hook of phone. N24 N30 N48
(Close and open at Remote [ ] [ ] [ ]
equ. at terminal 0a-0b)
Measure Output level. Feed into rem. equ. at Configured Output dBm N02 N08 N14
Feed 800 Hz with configured terminal 8a-8b level ±1 dB (600 ) N24 N30 N48
input level of remote Measure at terminal (Def.: -3.5 dBm) [ ] [ ] [ ]
subscriber.(Def.: 0.0 dBm) 2a-2b
PAX-BLOCKING normal Measure at terminal 5b-6a is open N02 N08 N14
5b-6a, 6a-6b 6a-6b is closed N24 N30 N48
[ ] [ ] [ ]
PAX-BLOCKING blocked Measure at terminal 5b-6a is closed N02 N08 N14
5b-6a, 6a-6b 6a-6b is open N24 N30 N48
Switch off remote equ., wait
about 30 sec. [ ] [ ] [ ]
B.11.11 Teleoperation AF1, if not Mark if not configured: N02 N08 N14 N20
used for telephony N24 N30 N42 N48 N54
[ ] [ ] [ ] [ ] [ ]
B.11.14 Teleoperation AF4 Mark if not configured: N02 N08 N14 N20
N24 N30 N42 N48 N54
[ ] [ ] [ ] [ ] [ ]
Fed input level, [dBm], Feed into rem. equ. at Expected Output Measured Output level at
@ 800 Hz at AF4-IN terminal 13a-13b level at AF4-OUT AF4-OUT
N02/N24: ___________±1 Measure at terminal N02/N24: ______±1 dBm N02/N24: ___________
14a-14b
N08/N30: ___________±1 N08/N30: ______±1 (600 ) N08/N30: ___________
O4CV#2: N_____
O4CV#3: N_____
O4CV#4: N_____
B.16 Documentation
CUSTOMER ACCEPTANCE
The acceptance form is completed by ABB and the customer representative once all equipment tests
detailed in this document have been performed successfully. Customer acceptance form is part of the
test report.
Date: ……………….……
Supervisor: _____________________________
FAT Witnessed
Date: _____________________________
Engineer: _____________________________
…………………………………………………..... _____________________________