Professional Documents
Culture Documents
GIGA Beam
Long-term stable detection Stable Detection Even for Prevent false detection of light
in dusty environments Workpieces with Low Reflection from reflections of other objects
Through- Comparisons of incident light level Reflective Comparisons of incident light level
beam Stable detection in narrow locations
1403 325 150mm
1m
Previously: 60°*
10 3.5 Sensing distance : 150mm
times Sensing distance : 1m
HS Mode
times HS Mode
Sensing object :
93 Glossy black plastics
Built-in
Build-in Lens Workpiece
50mm
140 15°
Built-in Lens Previously* * models without Built-in Lens Previously* * models without * models without
E32-LT11R lenses. E32-LD11R lenses. lenses.
Approximately 10 times the light intensity of Approximately 3.5 times the light intensity of Aperture angle of 15° reduces false
conventional models. High power achieves conventional models. Differences in incident detection due to reflected light.
long-term stable detection. level increased providing stable detection for
black workpieces.
No lens
attachment Approximately
80mm
is required!
No Protrusion!
Built-in Lens
No need to select a fiber-lens combination Save time and money, a lens falling off and Comparison to Fiber Units without a Lens
with a Sensing Distance of 300 mm
or attach a lens to the fiber head. The lens getting mixed with the workpieces would
(Spots Overlapped in the Center)
does not protrude for tighter installation. require ordering a new one in most cases. * models without lenses.
Applications
Positioning Paper in Detection of Labels Detection of Narrow Detection of Electronic
Book Production through Label Backings Spaced Parts Components inside Devices
The high power provides stable The high power lets the light Aperture angle of 15° ensures Aperture angle of 15° ensures
detection even in environments penetrate the backing material stable detection even with stable detection of small
containing dust or debris. for stable label detection narrowly spaced workpieces. components.
2
Through-beam Fiber Units
Specifications
Type Sensing distance (mm) Optical axis
Bending Simple Fiber diameter
Appearance (mm) radius Smart Fiber Amplifier Units (minimum
Sensing Aperture Amplifier Units Models
(Advanced Models) E3X-HD
direction angle of cable (Simple Models) sensing
E3X-SD GIGA HS Other modes object)
R25 2,100
4,000
* ST : 4,000
* E32-LT11 2M
2,700 SHS: 1,080
Top-view 15° 15 2.3 dia.
(0.1 dia.)
M4
Flexible,
1,800
4,000
* ST : 3,500
E32-LT11R 2M
R1
2,300 SHS: 920
IP50
* The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note1. The mode of E3X-HD that is given under the sensing distances has the following mode names and response times:
GIGA: GIGA Power Mode (16 ms), HS: High-speed Mode (250 μs), ST: Standard Mode (1 ms), and SHS: Super-high-speed Mode (NPN output: 50 μs, PNP output: 55 μs)
Note 2. The values for the minimum sensing object are reference values that indicate values obtained in Standard Mode with the sensing distance and sensitivity set to the optimum values.
Dimensions (mm)
M4×0.7 (Trivalent chrome-plated zinc alloy)
E32-LT11 2M / E32-LT11R 2M
Lens (PMMA) Opposite side: 7, Thickness: 2.4 (Nickel-plated brass)
(Free Cut) Washers (Nickel-plated iron)
2.2 dia.
860 ST : 360
R25 190 E32-LD11 2M
23 250 SHS: 110
Top-view 15° (0.1 dia.)
M6
Flexible, 840 ST : 350
180 E32-LD11R 2M
R1
240 SHS: 100
IP50
Note1. The mode of E3X-HD that is given under the sensing distances has the following mode names and response times:
GIGA: GIGA Power Mode (16 ms), HS: High-speed Mode (250 μs), ST: Standard Mode (1 ms), and SHS: Super-high-speed Mode (NPN output: 50 μs, PNP output: 55 μs)
Note 2. The values for the minimum sensing object are reference values that indicate values obtained in Standard Mode with the sensing distance and sensitivity set to the optimum values.
Note 3. The sensing distances for Reflective Fiber Units are for white paper.
Point
3
Through-beam Fiber Units
Installation Information
Installation Cable Weight
Models Ambient Unbendable Emitter/receiver (packed state)
Tightening torque Bending radius Tensile strength Sheath material Core material (g)
temperature length differentiation
E32-LT11 2M R25 10
-40 to 70℃ 0.78N . m 29.4N Polyethylene Plastic None 40
E32-LT11R 2M R1 0
S
Pre-wired (2 m) E3X-HD11 2M E3X-HD41 2M
mart Fiber
Wire-saving
Standard E3X-HD6 E3X-HD8
connector
Communication E3X-CRT or
unit E3X-ECT E3X-HD0
Wire-saving Connectors
Type Appearance Number of conductors Model
Slave
Master
3 E3X-CN11 connector
connector
Master E3X-CN12
connector
Slave E3X-CN11
1 E3X-CN12
connector
There is no master/slave distinction for the Wire-saving
Amplifiers. Along with the Amplifier, purchase the
Communication Units Connectors that are required for the application.
The Master connector is for the first amplifier, and the
Method Appearance Applicable Units Model Slave connectors are for the second and any additional
Amplifiers.
CompoNet E3X-CRT
E3X-HD0
E3X-MDA0
E3X-DA0-S
EtherCat E3X-ECT
OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE OTHER OMRON LATIN AMERICA SALES
Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com 54.11.4783.5300
Omron Europe B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • Tel: +31 (0) 23 568 13 00 • Fax: +31 (0) 23 568 13 88 • www.industrial.omron.eu
E45I-E-01 Note: Specifications are subject to change. © 2012 Omron Electronics LLC Printed in U.S.A.