8 7 6 5 4 3 2 1

H H

GGS ATEX: Zone 2, IIC, T1


P165338A-GGS-1 2600
-Cold insulated- L204 WATER FEED
3
RC_H

2610 P165338A-N2P-1
L202 N2 PANEL VENT
6

2593 P165338A-GGS-1 2603 P165338A-GGS-1


WATER FEED L204 -Cold insulated- L202 GGS TO HYD VENT
3 35
RC_O STACK
XV2 F-O
P165338A-GGS-1 2597 2598 P165338A-GGS-1
G GGS TO OXY VENT L201 L202 GLS TO HYD VENT
G
35 35
STACK STACK

3
P165338A-GGS-1 2602 XV2 F-H 2609
GLS TO OXY VENT L201 L202 HYDROGEN VENT
35 35
STACK STACK

FO FO

3
OXYGEN VENT L201 L204 L204 L204 HYDROGEN VENT
39 3 3 3 3 3 3 39
STACK STACK
A4 XV F_O-A XV F-O NRV F-O NRV F-H XV F-H XV F_H-A A58

3
F F

3
XV F-WL_H

L202
-Cold insulated- L203

L201
2781 P165338A-CH-1
DEMIN WATER
COOLING IN

3
A37
P165338A-DWS-1 2791 P165338A-CH-1 2784
E DEMIN WATER TO L201 DEMIN WATER
E
BREAKTANK COOLING OUT
A1 A36

LS BT_H LL
LS 22
06

L203

L203
-Cold insulated-
-Cold insulated-

-Cold insulated-
WL_O WL_H
D D
BT_H C F_H

L203
301
LT BT_H L203
301
LT
03 PT F_H
L201 PT
02
BV WL_O-D BV WL_H-D

M
74

3
C L203 L203
C

BV1 BT_H-D BV2 BT_H-D


F F_H P F_H

LS DT0
LS
DT0 07

GGS SKID: NO ATEX

B B
04 6/04/2018 DVR For Construction
03 19/03/2018 DVR
02 31/01/2018 DVR RDA For Construction
01 23/01/2018 DVR HCE

Rev. Date Drawn By Chk'd By Description Adjustments


Customer Project Drawn By

Ebner Pakistan P165338 DVR


Unit Checked By
A
HySTAT Date
A Description 6/04/2018 A
P&ID Gas Generation System System Rev.
Recovery & Feed Skid GGS 04
P165338A-GGS-2
All rights reserved. This drawing and the information contained therein is confidential and the sole and exclusive property of
Hydrogenics Corporation. No use of, or disclosure of, this drawing and the information contained therein shall be made without the
prior written permission of Hydrogenics Corporation. All authorized reproductions of this drawing shall bear this notice.

8 7 6 5 4 3 2 1