Professional Documents
Culture Documents
15,0 barg
H2 TO VENTLINE
35
SV Deo
H PI Deo H
34
34
PI
15,0 barg 15,0 barg
1108
XV1 H-A XV3 H-A HV2 H-A
PT Deo SV Da_H SV Db_H
2 PTZ
1107
TE H-U
DPT H-U HV_DPT_H-U HV1 H-A HV3 H-A
TT DPT
TE3 Deo 1160 582
TTZ 1
1103
TTZ PI
734 1160
35
34
1 XV12 7,0 barg
XV11
H2 TO USER
H_DEO 35
BPR H-U XV2 H-U NRV2 H-U BV H-U
2
DEOXO
F F
XV4 XV3
HV S2_H
6
S-2 S-2
MS_DEO
S-3 S-3 FO FO
6
S-4 S-4
XV1 XV2
TE HPS
C_DEO S-1 HX1_R S-1 HX2_R
TE
676
6
P165338A-GGS-1
H2 FROM GGS
FT AD_DEO
6
E FO FO E
BV_H
XV10 XV9
P165338A-N2P-1
N2 TO HPS
3
PI Da_H PI Db_H
NRV1 N
PI PI
1128 1138
TE Da In TE Db In
TT TT
1121 1131
TE3 Da_H TE3 Db_H
TTZ 1 TTZ 1
D 1123 1133 HAZARDOUS AREA: Zone 2, GAS GROUP IIC, TEMPERATURE CLASS T1 D
DRYER_A DRYER_B
TE4 Da_H TE4 Db_H
TT TT
TE1 Da_H 726 TE1 Db_H 727
TT TT
1124 1134
TE2 Da_H TE2 Db_H
TTZ TTZ
729 728
1 H DA_H 1
H DB_H
C C
P165338A-CH-1
CHILLED WATER OUT
304
TE Da Out TE Db Out
TT TT
1122 1132
P165338A-CH-1
CHILLED WATER IN
304
XV6 XV5
C_R
B B
05 06/06/2018 PFA RDA Add XV1 H-A
XV8 XV7
04 06/04/2018 DVR PFA For Construction
MS_R 03 19/03/2018 DVR
8 7 6 5 4 3 2 1