Corrosive Applications
• Concrete Exposed to • Electromagnetic
De-Icing Salts Applications
Bridge decks, Median barriers, MRI rooms in hospitals
Approach slabs, Parking structures, Airport radio & compass calibration pads
Railroad crossings, Salt storage Concrete near high voltage cables,
facilities tranformers and substations
600
500
Stress (MPa)
400
300
100
0
0 0.005 0.01 0.015 0.02 0.025
Strain
Bond Stress
Bond of GFRP to concrete is controlled by friction due to surface
roughness of the GFRP rods and mechanical interlock of the GFRP rod
against the concrete.
Aslan 100
FIBERGLASS REBAR
Potential durability versus traditional steel reinforcement is one of the
chief benefits of GFRP Rebar. However, being a relatively new material
for use as a concrete reinforcement, decades of performance data are
not available.
Fortunately, research from the ISIS network in Canada which involved
extracting GFRP bars from several bridges and structures across
Canada that have been in service from between 5 to 8 years reveals Microscopy photo of Hughes
NO DEGRAEDATION of the GFRP bars. (Durability of GFRP Reinforced Brothers Rebar - 60 X
Concrete from Field Demonstration Structures – M. Onofrei University of
Manitoba, May 2005). This performance matches that of GFRP dowel
bars that had been extracted from service in Ohio after 20 years.
Creep
When subjected to a constant load, all structural materials, including
steel, may fail suddenly after a period of time, a phenomenon known
as creep rupture. Creep tests conducted in Germany by Bundelmann
& Rostasy in 1993, indicate that if sustained stresses are limited to Microscopy photo of Hughes
less than 60% of short term strength, creep rupture does not occur in Brothers Rebar - 240 X
GFRP rods. For this reason, GFRP rebars are not suitable for use as
prestressing tendons. In addition, other environmental factors such as
moisture can affect creep rupture performance.
Based on proposed ACI 440 design guidelines, it is recommend-
ed that the sustained tensile stress not exceed 20% of minimum
ultimate tensile stress. For a summary of the recommended design
guidelines, refer to 440.1R-06 or your controlling national guide.
Some bent shapes are made using
3
Design Considerations
A direct substitution between of GFRP rebar rather than a and crack width serviceability
Aslan 100
FIBERGLASS REBAR
GFRP and steel rebar is not maxiumum. If a member fails, the requirements will provide
possible due to various differences concrete will be the weak link and additional warning of failure prior
in the mechanical properties of will crush in compression. The to compression failure of concrete.
the two materials. In traditional crushing concrete will serve as In many
steel reinforced concrete design, the warning of failure and there instances,
a maximum amount of steel will still be ample reserve tensile deflection
reinforcing has been specified so capacity in the GFRP reinforcing. and crack
that the steel is the weak link in Another major difference is width will
a structure. When weakened, the that serviceability will be more control
steel rebars stretch or yield and a of a design limitation in GFRP design.
give a warning of pending failure reinforced members than in
of the concrete member. steel reinforced members. Due
When using GFRP Rebars, ACI to it's lower modulus of elasticity,
committee 440's design guidelines deflection and crack width will
recommend a minimum amount affect the design. Deflection
Handling and • GFRP rebar has a very low tested based on a random
statistical sampling, with a
Placement specific gravity and will tend
to "float" in concrete during minimum of 5 samples per
• When necessary, cutting of
vibration. Care should be production lot.
GFRP rebars should be done
exercised to adequately secure • Certification of conformance
with a masonry or diamond
GFRP in formwork using chairs, is available for any given
blade, grinder or fine blade
plastic coated wire ties or nylon production lot.
saw. A dust mask is suggested
zip ties. • In addition, quality assurance
when cutting the bars. It is
tests are routinely performed to
recommended that work gloves Lap Splice Length determine:
be worn when handling and Glass content (i.e. impregnation ASTM
placing GFRP rebars. Given by 440.1R-06. D2584)
Quality Assurance
Die wicking (checking for voids ASTM
• Sealing of cut ends is not D5117)
necessary since any possible • To provide for lot or production Barcol hardness ASTM D2583
Cross sectional area ACI 440-K
wicking will not ingress more run traceability, each lot is color
Mass uptake in water ASTM D4475
than a small amount into the end coded. Interlaminear shear or shear in flexure
of a rod. • Individual rebars are tensile ASTM D4475
Tensile modulus and strain per ASTM
Masonry Strengthening
D7205.