You are on page 1of 10

HVZ adhesive anchor

Features:
- foil capsule vs. glass
- flexibly to fit in irregular holes HVU-TZ capsule

- marking for identification after setting


- test reports: fire, dynamic (fatigue, shock), water
HAS-TZ, HAS-RTZ and
tightness
Material: HAS-HCR-TZ anchor rod

- urethane methacrylate resin – styrene free,


HVU-(E-)TZ: hardener,
quartz sand, foil tubes
- grade 8.8; EN ISO 20898-1; coating: DIN 50968- Close edge
HAS-(E-)TZ: Concrete Tensile zone distance/ Fatigue Shock
FE/Cu 3 Ni 10 spacing
HAS-(E-)RTZ: - stainless steel; A4-80; 1.4401; 14571; EN 10088
HAS-(E-)HCR-TZ: - stainless steel; 1.4529; 1.4547; EN 10088-3 A4 HCR
316 highMo

Corrosion High corrosion Hilti Anchor


Fire resistance
resistance resistance programme

Basic loading data (for a single anchor): HAS-(E-)TZ


All data on this page applies to For detailed design method, see pages 184 – 189.
x concrete: See table below.
x correct setting (See setting operations page 183)
x no edge distance and spacing influence
x steel failure

non-cracked concrete cracked concrete

Mean ultimate resistance Ru,m [kN]: concrete # C20/25


Anchor size  M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRu,m 38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9
Shear VRu,m 20.1 29.2 54.2 54.2 93.3 20.1 29.2 54.2 54.2 93.3

Characteristic resistance, Rk [kN]: concrete # C20/25


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRk 32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8
Shear VRk 18.0 27.0 51.0 51.0 88.0 18.0 27.0 51.0 51.0 88.0

Following values according to the:

Concrete Capacity Method

Design resistance, Rd [kN]: concrete fck,cube = 25 N/mm2


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRd 21.8 26.7 36.2 47.0 74.5 13.3 22.2 25. 8 33.5 53.2
Shear VRd 14.4 21.6 40.8 40.8 70.4 14.4 21.6 40.8 40.8 70.4

Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRec 15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0
Shear VRec 10.3 15.4 29.1 29.1 50.3 10.3 15.4 29.1 29.1 50.3

180 Issue 2005


HVZ adhesive anchor

Basic loading data (for a single anchor): HAS-(E-)RTZ


All data on this section applies to For detailed design method, see pages 184 – 189.
x concrete: See table below.
x correct setting (See setting operations page 183)
x no edge distance and spacing influence
x steel failure

non-cracked concrete cracked concrete

Mean ultimate resistance, Ru,m [kN]: concrete # C20/25


Anchor size  M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRu,m 38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9
Shear VRu,m 22.6 32.7 61.0 61.0 103.9 22.6 32.7 61.0 61.0 103.8

Characteristic resistance, Rk [kN]: concrete # C20/25


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRk 32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8
Shear VRk 20.0 30.0 56.0 56.0 98.0 20.0 30.0 56.0 56.0 98.0

Following values according to the:

Concrete Capacity Method 3


Design resistance, Rd [kN]: concrete fck,cube = 25 N/mm2

Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRd 21.8 26.7 36.2 47.0 74.5 13.3 22.2 25..8 33.5 53.2
Shear VRd 16.0 24.0 44.8 44.8 78.4 16.0 24.0 44.8 44.8 78.4

Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRec 15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0
Shear VRec 11.4 17.1 32.0 32.0 56.0 11.4 17.1 32.0 32.0 56.0

Basic loading data (for a single anchor): HAS-(E-)HCR-TZ


All data on this section applies to For detailed design method, see pages 184 – 189.
x concrete: See table below.
x correct setting (See setting operations page 183)
x no edge distance and edge influence
x steel failure

non-cracked concrete cracked concrete

Mean ultimate resistance, Ru,m [kN]: concrete # C20/25


Anchor size  M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRu,m 38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9
Shear VRu,m 25.1 36.4 61.0 61.0 105.8 25.1 36.4 61.0 61.0 105.8

Issue 2005 181


HVZ adhesive anchor

Characteristic resistance Rk [kN]: concrete # C20/25


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRk 32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8
Shear VRk 20.0 30.0 56.0 56.0 98.0 20.0 30.0 56.0 56.0 98.0

Following values according to the:

Concrete Capacity Method

Design resistance Rd [kN]: concrete fck,cube = 25 N/mm2


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRd 21.8 26.7 36.2 47.0 74.5 13.3 22.2 25..8 33.5 53.2
Shear VRd 16.0 24.0 44.8 44.8 78.4 16.0 24.0 44.8 44.8 78.4

Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2


Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile NRec 15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0
Shear VRec 11.4 17.1 32.0 32.0 56.0 11.4 17.1 32.0 32.0 56.0

Setting details
df
d0

HVZ ...

HAS-TZ HAS-E-TZ

hef t fix
h1
hmin

Anchor size M10x75 M12x95 M16x105 M16x125 M20x170


Foil capsule HVU-TZ M.. 10x90 12x110 16x125 20x190

Anchor rod HAS-(E-)TZ M.. 10x75/ tfix 12x95/ tfix 16x105/ tfix 16Lx125/tfix 20x170/ 40

d0 [mm] Drill bit diameter 12 14 18 25


h1 [mm] Hole depth 90 110 125 145 195
hmin [mm] Min. thickness of base material 150 190 210 250 340
25 / 50 / 100
tfix [mm] Max. fixture thickness 15 / 30 / 50 (and 40 for 30 / 60 / 100 40
HAS-RTZ)
Clearance hole rec. 12 14 18
df [mm] 22
(without bending verification) max. 13 15 19
Tightening HAS-TZ 40 50 90
Tinst [Nm] 100 150
Torque HAS-R/HCR-TZ 50 70
TE–CX 12/22 TE–CX 14/22 TE–C 18/32S TE–C 25/27S
Drill bit
TE-TX 12/32 TE-TX 14/32 TE-T 18/32 TE-T 25/32

182 Issue 2005


HVZ adhesive anchor

Base material temperature Min. time to wait before Curing time:


removing SCREWED-ON tcure
setting tool (not applicable for
TE-C HEX):
trel
20°C and higher 8 min. 20 min.
10°C to 20°C 20 min. 30 min.
0°C to 10°C 30 min. 1 hour
-5°C to 0°C 1 hour 5 hours
less than -5°C Please consult your Hilti technical service.

Installation equipment
A rotary hammer (TE5, TE6, TE15, TE-15C, TE-18M, TE35, TE55, TE76); max. setting speed of 850 r.p.m
(rotary hammering action); a drill bit, a blow out pump and a setting tool: TE-C HEX (M10-M16), TE-Y HEX
(M20);

Setting operations

1 2 3 HVU-TZ 4
TE-C HEX
® ® ®

Blow out dust and Drive in with rotary


3
Drill hole. Insert HVU-TZ capsule.
fragments. hammering action.

5 6 7 Tinst
trel
tcure

Allow rel time to pass Wait for curing Apply tightening torque.

Anchor geometry and mechanical properties

Marking of material and anchorage depth


for HAS-TZ: HVZ...
for HAS-RTZ: HVZ R...
for HAS-HCR: HVZ HCR...
dw
d

Sw
dk
dp

HVU-TZ M.. HVU-TZ M..


hef
lp l

Issue 2005 183


HVZ adhesive anchor

Anchor size M10 M12 M16x105 M16x125 M20


HVU-TZ capsule:
lp [mm] HVU-TZ foil capsule length 110 127 140 200
dp [mm] HVU-TZ foil capsule diameter 11.0 13.0 17.0 23.0
HAS-(E-)TZ/-RTZ/-HCR-TZ:
Stressed cross-sectional area
44.2 56.7 95.0 153.9
under tensile loading:
As [mm²]
Stressed cross-sectional area
58.0 84.3 157.0 245.0
under shear loading in thread:
HAS-TZ 8.8 800
Nominal tensile
fuk [N/mm²] HAS-RTZ 800
strength (point)
HAS-HCR-TZ 800
HAS-TZ 8.8 640
Nominal yield
fyk [N/mm²] HAS-RTZ 600
strength (point)
HAS-HCR-TZ 600
W [mm³] Section modulus 62.3 109.0 277.0 541
HAS-TZ 8.8
Design bending
MRd,s [Nm] HAS-RTZ and 38.4 68.8 181.6 415.2
resistance
HAS-HCR-TZ
d [mm] Shank diameter 10 12 16 20
dk [mm] Anchor end diameter 10.8 12.8 16.8 22.7
hef [mm] Actual anchorage depth 75 95 105 125 170
l [mm] Anchor length 124/139/159 158/183/233 181/211/251 201/231/271 269
Sw [mm] Width across flats 17 19 24 30
dw [mm] Washer outside diameter 20 24 30 37
1)
The design bending resistance of the anchor rod was calculated using MRd,s = MRk,s/JMs,b , where the partial safety factor JMs,b is 1.25.

Detailed design method - Hilti CC


(The Hilti CC-Method is a simplified Version of ETAG Annex C)

Caution: In view of the high loads transferable with HVZ, it must be verified by the user that the load on the
concrete structure including the loads introduced by the anchorage do not cause failure (e.g. cracking) of the
concrete structure.

TENSION
The tensile design resistance of a single anchor Nrec,c/s
is the lower of,
NRd,c : concrete cone/pull-out resistance s
c
NRd,s : steel resistance
h

184 Issue 2005


HVZ adhesive anchor

NRd,c: Concrete cone/pull-out resistance

o
NRd,c NRd,c ˜ fB,N ˜ f A,N ˜ fR,N

N0Rd,c : Concrete cone/pull-out design resistance


x Concrete compressive strength fck,cube(150) = 25 N/mm2
Anchor size M10 M12 M16 M16L M20
0 1)
N Rd,c [kN] in non-cracked concrete 21.8 26.7 36.2 47.0 74.5
0 1)
N Rd,c [kN] in cracked concrete 13.3 22.2 25.8 33.5 53.2
hef [mm] Actual anchorage depth 75 95 105 125 170
1) o o o
The design tensile resistance is calculated from the characteristic tensile resistance N Rk,c by N Rd,c= N Rk,c/JMc,N, where the partial
safety factor JMc,N is 1.5.

fB,N : Influence of concrete strength


Concrete strength Cylinder compressive Cube compressive
designation strength strength
(ENV 206) fck,cyl [N/mm²]
fB,N
fck,cube [N/mm²]
C20/25 20 25 1

3
C25/30 25 30 1.1
C30/37 30 37 1.22 fck,cube
C35/45 35 45 1.34 fB,N
C40/50 40 50 1.41
25
C45/55 45 55 1.48 Limits: 25 N/mm2 d fck,cube d 60 N/mm2
C50/60 50 60 1.55
Concrete cylinder: Concrete cube:
height 30cm, 15cm side length 15cm
diameter
Concrete test specimen geometry

fA,N: Influence of spacing


Spacing, Anchor size
s [mm] M10 M12 M16 M16L M20
50 0.61
60 0.63 0.60
65 0.64 0.61
70 0.66 0.62 0.61 0.59
75 0.67 0.63 0.62 0.60
80 0.68 0.64 0.63 0.61 0.58
85 0.69 0.65 0.63 0.61 0.58
90 0.70 0.66 0.64 0.62 0.59
100 0.72 0.68 0.66 0.63 0.60
120 0.77 0.71 0.69 0.66 0.62
135 0.80 0.74 0.71 0.68 0.63
140 0.81 0.75 0.72 0.69 0.64
160 0.86 0.78 0.75 0.71 0.66
180 0.90 0.82 0.79 0.74 0.68
200 0.94 0.85 0.82 0.77 0.70
220 1.00 0.89 0.85 0.79 0.72
240 0.92 0.88 0.82 0.74

Issue 2005 185


HVZ adhesive anchor

fA,N: Influence of spacing


Spacing, Anchor size
s [mm] M10 M12 M16 M16L M20
270 0.97 0.93 0.86 0.76
300 1.00 0.98 0.90 0.79
330 1.00 0.94 0.82
360 0.98 0.85
390 1.00 0.88
420 0.91
450 0.94
480 0.97
510 1.00

s
f A,N 0 .5  Limits: smin d s d scr,N
6h ef

Anchor size M10 M12 M16 M16L M20


smin [mm] 50 60 70 80
scr,N [mm] 225 285 315 375 510

fR,N: Influence of edge distance


Edge Anchor size

distance
, M10 M12 M16 M16L M20
c [mm]

50 0.58
60 0.65
65 0.68
70 0.72 0.62
75 0.75 0.64
80 0.78 0.67 0.49
85 0.82 0.70 0.65 0.59 0.50
90 0.85 0.72 0.68 0.61 0.51
95 0.88 0.75 0.70 0.63 0.53
100 0.92 0.78 0.73 0.65 0.54
105 0.95 0.80 0.75 0.67 0.56
110 0.98 0.83 0.77 0.69 0.57
115 1.00 0.86 0.80 0.71 0.59
125 0.91 0.85 0.75 0.62
135 0.96 0.89 0.79 0.65
145 1.00 0.94 0.83 0.68
155 1.00 0.87 0.71
165 0.91 0.74
175 0.95 0.76
185 1.00 0.79
205 0.85
230 0.93
255 1.00

c
fR,N 0.25  0.50 Limits: cmin d c d ccr,N
h ef

Anchor size M10 M12 M16 M16L M20


cmin [mm] 50 70 85 80
ccr,N [mm] 113 143 158 188 255

Note: If more than 3 edge distances are smaller than ccr,N, please contact your Hilti technical service.

186 Issue 2005


HVZ adhesive anchor

NRd,s : Steel design tensile resistance

Anchor size M10 M12 M16 M16L M20


1)
NRd,s [kN] 23.3 34.0 60.0 121.3
1)
The design value is calculated using NRd,s= NRk,s /JMs,N, where the partial safety factor, JMs,N , is 1.5.

NRd : System design tensile resistance

NRd = lower of NRd,c and NRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

Detailed design method – Hilti CC


(The Hilti CC-Method is a simplified Version of ETAG Annex C)
c2 >
1.5
c
V rec,c/s 3
s
c c2 >
1.5
c
SHEAR h>
1.5
c
The design shear resistance of a single
anchor is the lower of,
VRd,c : concrete edge resistance
VRd,s : steel resistance Note: If the conditions shown for h and c2 cannot be
observed, please contact your Hilti sales representative.

VRd,c : Concrete edge design resistance


The lowest concrete edge resistance must be calculated. All near edges must be checked, (not only the edge in
the direction of shear). The direction of shear is accounted by the factor fE,V.

0
VRd,c VRd,c ˜ f B,V ˜ f E,V ˜ f AR,V

V0Rd,c : Concrete edge design resistance


x Concrete compressive strength fck,cube(150) = 25 N/mm2
x at a minimum edge distance c min

Issue 2005 187


HVZ adhesive anchor

Anchor size M10 M12 M16 M16L M20


0 1)
V Rd,c [kN] non-cracked concrete 3.5 6.4 9.6 9.9 10.3
V0Rd,c1) [kN] cracked concrete 2.5 4.6 6.9 7.1 7.4
cmin [mm] min. edge distance 50 70 85 80
1)
The design value of the ultimate state in shear is calculated from the characteristic anchor shear resistance, V°Rk,c, divided by
V°Rd,c= V°Rk,c/JMc,V, where the partial safety factor, JMc,V, is 1.5.

fB,V : Influence of concrete strength


Concrete strength Cylinder compressive Cube compressive
designation strength strength
(ENV 206) fck,cyl [N/mm²]
fB,V
fck,cube [N/mm²]
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22 fck,cube
C35/45 35 45 1.34 fB,V
C40/50 40 50 1.41
25
C45/55 45 55 1.48 Limits: 25 N/mm2 d fck,cube d 60 N/mm2
C50/60 50 60 1.55
Concrete cylinder: Concrete cube:
height 30cm, 15cm side length 15cm
diameter
Concrete test specimen geometry

fE,V : Influence of shear load direction

Angle E [°] fE,V Formulae:


V ... applied shear force
0 to 55 1 fE,V 1 for 0° d E d 55°
60 1.1 1
E
70 1.2 fE,V for 55° < E d 90°
cos E  0.5 sin E
80 1.5
fE,V 2 for 90° < E d 180°
90 to 180 2

fAR,V : Influence of edge distance and spacing


Formula for single-anchor fastening
Influenced only by edge
c 2,1
c c s n-1
f AR,V
c min c min s3
results
tabulated s2
Formula for a two-anchor fastening valid s1
for s < 3c below c 2,2 c
3c  s c
f AR,V
6c min c min h >1,5 c

General formula for n-anchor fastening (edge plus n-1 spacing)


only valid where s1 to sn-1 are all < 3c and c2 > 1.5c Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load
3c  s1  s 2  ...  s n 1 c
f AR ,V ˜
3nc min c min

188 Issue 2005


HVZ adhesive anchor

fAR.V c/cmin
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single anchor with
edge influence 1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/cmin 1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 These results are for a two-. 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 Anchor fastening. 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 For fastening made with more 5.69 6.05 6.42 6.79 7.17
10.0 than 2 anchors, use the 6.21 6.58 6.95 7.33
10.5 general formulae for n 6.74 7.12 7.50
11.0 anchors. 7.28 7.67
11.5 7.83
12.0 8.00

3
VRd,s : Steel design shear resistance

Anchor size M10 M12 M16 M16L M20


VRd,s1)[kN] HAS-(E-)TZ 14.4 21.6 40.8 70.4

VRd,s1) [kN HAS-(E-)RTZ, HAS-(E-)HCR 16.0 24.0 44.8 78.4


1)
The design shear resistance is calculated using VRd,s= VRk,s/JMs,V. The values for the stressed
cross section As and the nominal tensile strength of steel, fuk, are given in the table „Anchor mechanical properties and geometry“. The
partial safety factor, JMs,V is 1.25.
VRd : System design shear resistance
VRd : System shear design resistance

VRd = lower of VRd,c and VRd,s

Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 “Examples”).

Issue 2005 189