You are on page 1of 2

SZ12-17

12V 17Ah(20hr)
Overview
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by
separators and plates and thus immobilized. Should the battery be accidentally overcharged producing
hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure
build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and
usable in any position.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass sulfuric acid

General Features Battery Specification


Absorbent Glass Mat (AGM) technology for efficient gas Performance Characteristics
Nominal Voltage 12V
recombination of up to 99% and freedom from electrolyte
Number of cell 6
maintenance or water adding. Design Life 5 years
Not restricted for air transport-complies with IATA/ICAO Nominal Capacity 77℉(25℃)
Special Provision A67. 20 hour rate (0.85A, 10.5V) 17Ah
UL-recognized component. 10 hour rate (1.68A, 10.5V) 16.8Ah
Can be mounted in any orientation. 5 hour rate (3.09A, 10.5V) 15.45Ah
Computer designed lead, calcium tin alloy grid for high power 1 hour rate (11.8A, 9.6V) 11.8Ah
density. Internal Resistance

Long service life, float or cyclic Fully Charged battery 77°F(25°C) ≤14.0 mOhms
Self-Discharge
applications.
3% of capacity declined per month at 20℃(average)
Maintenance-free operation. Operating Temperature Range
Low self discharge. Discharge -20~60℃
Case and cover available in both standard and flame Charge -10~60℃
retardant ABS. Storage -20~60℃
Max. Discharge Current 77℉(25℃) 225A(5s)
Dimensions and Weight Short Circuit Current 850A
Length(mm / inch) 181/7.13 Charge Methods: Constant Voltage Charge 77℉(25℃)
Cycle use 14.5-14.9VPC
Width(mm / inch) 77/3.03
Maximum charging current 6.8A
Height(mm / inch) 167/6.57
Temperature compensation -30mV/℃
Total Height(mm / inch) 167/6.57
Standby use 13.6-13.8VPC
Approx. Weight(Kg / lbs) 5/11.0
Temperature compensation -20mV/℃
* Weight deviation: ± 3%
Discharge Constant Current (Amperes at 77oF25oC)
E n dP o i n t
5 mi n 10m i n 15m i n 30m i n 1h 3h 5h 10h 20h
Vo l ts / ce l l

1. 60V 64. 9 44. 1 34 19. 8 11. 8 4. 57 3. 09 1. 78 0. 89


1. 65V 62. 8 43 33. 3 19. 4 11. 6 4. 5 3. 03 1. 75 0. 88
1. 70V 60. 5 41. 9 32. 6 18. 9 11. 4 4. 42 2. 97 1. 72 0. 87
1. 75V 58 40. 7 31. 8 18. 4 11. 2 4. 35 2. 91 1. 68 0. 85
1. 80V 55. 3 39. 4 30. 9 17. 9 10. 9 4. 27 2. 84 1. 65 0. 84

o o
Discharge Constant Power (Watts at 77 F25 C)
E ndPoi nt
10min 15m i n 30m i n 45m i n 1h 2h 3h 5h
Vo l ts / ce l l

1. 60V 531 423 256 181 168 92. 6 66 45. 9


1. 65V 504 409 248 178 165 91. 1 65. 2 45. 7
1.7V 47 8 396 242 174 163 89. 4 64. 4 45. 3
1. 75V 453 382 234 169 158 87. 8 63. 7 45
1. 80V 423 369 226 166 153 86. 9 62. 5 44. 6

(Note)The above characteristics data are average values obtained


within three charge/discharge cycles not the mimimum values.All data
shall be changed without notice,Tec power reserves the right to
explain and update the information contained hereinto.

www.tec-energia.com
SZ12-17
12V 17Ah(20hr)

Discharge characteristic (25 C)


O

13.0

12.0

11.0
Voltage(v)

10.0 35
11.8
9.0

8.0

0
0 1 2 3 5 10 20 30 60 2 3 5 0 1 20 30
min h
Discharge time

Relationship between
Self-discharge characteristic
charging voltage and temperature
110

100
15.6
90
Capacity(%)

Cycl
Voltage(V)

15.0 e Us
e
80
14.4
70
Stan d
13.8 b y Us
e
60 o o o
C C C
13.2 50

40
-10 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
Ambient temperature( oC) Storage time: months

Cycle service life in relation to


Life characteristics of Standby use
120 depth of discharge
120

100
100
Capacity(%)

80
Capacity(%)

80

60 60
Testing conditions:floating voltage:2.27 to 2.30V Cell 100% D.O.D . 50% D.O.D . 30% Depth of discharge
ambient temperature: 25oC(77oF)
40 40

20 20

0 200 400 600 800 1000 1200 1400


0 1 2 3
Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


10
120

100
C
0 .0 5
Life(years)

0 .1 C
Capacity (%)

80
2.30V Cell 0.2 C
1 60
1 .0 C
40
2 .0 C
3 .0 C
20

0.1 0
10 20 30 40 50 60
-20 -10 0 10 20 30 40 50( o C)
o
Temperature( C) Temperature( oC)

www.tec-energia.com

You might also like