Symmetry Blue 933M,934M & 939M Wallplate/Keypad Reader Installation Leaflet

The Symmetry Blue Wallplate/Keypad Readers 933M,


933M-KP, 934M, 934M-KP, 939M and 939M-KP are
multi technology Card Readers.

All Reader variants will read card serial numbers from most
ISO 14443A smart cards which have a 4-byte UID (User
Identification), including smartMAX encoded MIFARE cards.
Supports SmartMAX on Desfire EV1/EV2.

In addition to the above:


The 933M and 933M-KP is also capable of reading ASK Prox.
The 934M, 934M-KP, 939M and 939M-KP will also read
Bluetooth via IOS and Android phones, with the 939M and
939M-KP readers also being capable of reading ASK and
FSK Prox modulation types.
All Reader variants use 20mA current loop communications to communicate with EN and M2150.

Note:
For additional information regarding the installation, configuration and proper use of this product:
Symmetry User Guide, P/N 9600-0429
?
EN-1DBC+ and EN-2DBC - Installation Guide, P/N 9600-0630
?
M2150 Access Control Design Guide, P/N 9600-0420
?
EN-DBU Installation Guide, P/N 9600-0660.
?

Package Contents
The package should be delivered free from visible damage and include the following contents:

Symmetry Blue 933M, 933M-KP, 934M, 934M-KP, 939M or 939M-KP Wallplate/Keypad Reader & backplate.
?
9600-0697 Symmetry Blue 933M 934M and 939M Reader Installation Leaflet (this document).
?
Install package 2 x Phillips #6 screws, 1 x #4-40 Phillips screw and 1 x T8 pin-in-torx.
?

If any of the items are missing or damaged please contact the supplier immediately.

1 Mount the Wall Plate and Attach Reader

1). Mount the backplate adjacent to Fig 1.


the opening edge of the door. 2 1 2
2). Using the Backplate as a guide Install Metal Wall Plate to Single Gang Box
connect the wall plate to the 1). Standard Single Gang Box Installation.
single gang box using #6 screws. 2). Alternatives for situations outside of a
Alternatively you can use the single gang box installation.
#4 screws in the four outer holes 2 2
for other installation requirements 1
(Fig1). Drywall installations will
require molly bolts. Fig 2.
3). Align the reader so that the tabs
of the base plate slide into the
slots on the wall plate and slide
the reader into position( Fig 2).
4). Install the #4-40 screw or (pin-
in-torx for extra security) at the
bottom of the reader (Fig 3). Fig 3.
2 Reader Connections

20mA Current Loop Controller


Reader
Red Power in Max Length to Controller
Black Ground
Shield Shield Ground Length AWG

Brown -
200' (60m) 22
Green Rx-

White Rx+ 300' (90m) 20


Yellow Tx-
500' (150m) 18
Blue Tx+

Twisted pairs
(Use Belden 9503) Connect shield at controller
end only.

3 Using / Testing the Reader


Power the reader, the red LEDs will light, followed by a beep. Present a valid credential to the reader and the
LEDs will turn green. The reader is now working correctly.
Cards can be presented in rapid succession; there is no need, for example, to wait for "GREEN LED’s" to
disappear before presenting another.
If the reader cannot read a card read. Check wiring for faults or replace reader.

LED Status Indicator


GREEN – The lock is released and you may open the door.
AMBER – ‘Enter your PIN’, If you make a mistake, The RED LED’s are momentarily displayed, followed by
Amber LEDs ‘s to prompt you to try again (for -KP variants only).
RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case,
present it again).

Installation tips:
Upon a power reset, the S900 Readers provide a reset sequence using the LED indicator and the beeper, to
provide information about the reader type and its communication mode. The first sequence (sequence A)
describes the credential technologies built into the reader:
A single red LED flash indicates Bluetooth credential support
?
A single green LED flash indicates 13.56 MHz credential support
?
A single amber LED flash indicates 125 kHz Prox credential support
?
Sequence A is followed by sequence B. Sequence B indicates the reader communication protocol:
One beep (with 3 x Green LED Flashes) indicate that the reader is in 20mA communication mode.
?

9600-0697 Symmetry Blue 933M, 933M-KP, 934M, 934M-KP, 939M Specifications


and 939M-KP Wallplate/Keypad Reader Installation Instructions, Issue Input voltage: 12Vdc.
1.0 17th May 2018. © AMAG Technology, 2018.
Input current: 190mA Max.
FCC Notice: This device complies with Part 15 of the FCC Rules. Operating temperature: -40 to 158°F (-40 to 70°C)
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept Operating humidity: 90%, non-condensing.
any interference received, including interference that may cause Configurable Card Read range: 4inch (100mm) to 10ft
undesired operation. (3Metres)
Any unauthorized modification to this device may void the authority of
G4S Technology for the user to operate it. All trademarks Approvals
acknowledged. EN302291, EN301489, EN300330, IP55.
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of this device.