TECHNICAL PARTICULAR AND GUARANTEE STEP-UP TRANSFORMERS150/15 kV 300& 100 MVA ['no. | DESCRIPTION UNIT SPECIFIED 1 GENERAL 11 | Standards lec 12 | Factory to be stated by bidder 4.3 | Type and design number to be stated by bidder 14 | Installation on site Outdoor 1.8 | Service conditions : a. Maximum altitude meter 1000 b. Maximum temperature of °c 40 ambient air and cooling medium c. Average monthly air *c 20 temperature d. Average annual ambient °c 30 temperature 1.6 | Installation environment pollution a. Dust pollution rate heavy b. Seismic disturbance 8 0.25 6. Acid pollution Refer to site condition 2 RATING AND PERFORMANCE 24 | Number of phase per unit 3 22 | Number of winding per phase 2 2.3 | Phase sequence from LV side (left R-S-T to right) ‘STANDARDISAS! SPESIFIKASI TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 41 NO. 24 25 26 27 28 29 2.40 241 DESCRIPTION UNIT ‘SPECIFIED | Vector group YN4i or YNd41 (Refer to existing) Reted power (S:) For HV & LV winding = Stage 1 (100% Sr) MvA 300 100 ~ Stage 2 (80% Sr) uva NA ~ Stage 3 (60% Sr) vA 240 60 Highest voltage (Um) for equipment a. HV winding kv 170 b. LV winding kv 175 Rated voltage (Ur) a, HV winding wv 187.5 b. LV winding kv 5 Highest voltage (Um) for neutral point a, HV winding kv 100 b. LV winding kv NA Neutral connection for HV winding solidly grounded “Tapping of HV winding (minimum) a. Number of steps 5 b, Number of taps. 6 (010 +5) c. Numbering of tap positions 106 4. Tapping factor (Ud/Ur) % 3,33 ‘Short-circult impedance (at 75 raied power) a. At principal tap % 12.5 b. At maximum tap % tobe stated by bidder . At minimum tap % to be stated by bidder —— STANDARDISASI SPESIFIKASI TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 42 a No. DESCRIPTION UNIT SPECIFIED a 242 | Voltage drop (or rise) as % of i] rated voltage at ful oad, At power factor 1 & 76 °C ry At principal tap % to be stated by bidder oe |B. Atmaximum tap % to be stated by bidder pas | & Atminimum tap % to be stated by bidder uv At power factor 0.8 & 75 °C : Z a. At principal tap % tobe stated by bidder j b. At maximum tap % to be stated by bidder ©. At minimum tap % to be stated by bidder ud 2.43 | Percent reactance drop at full cy load, power factor1&75°C | a a.At principal tap | % to be stated by bidder b. At maximum tap % to be stated by biddor } ©. At minimum tap % to be stated by bidder ] 2.14 | Percent resistance drop at full load, power factor 1 & 75°C } a At principal tap % to be stated by bidder J | b.Atmaximum tap % to be stated by bidder ©. At minimum tap % to be stated by bidder : 245 | Rated current , a. HV winding A 1099,7 358 b. LV winding A 11547 3849 uJ 2.48 | Lightning impulse withstand voltage: : a, HV winding | ow 750 ! b. LV winding KV 95 u 247 ‘Switching impulse withstand voltage: ; a. HV winding wv NA, ad LV winding Kv NA | STANDARDISAS! SPESIFIKASI TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 43 NO. DESCRIPTION UNIT SPECIFIED 2.48 | Power frequency withstand voltage: HV winding «wv 325 b. LV winding kv 38 2.19 | ‘Symmetrical short-circuit, withstand current (2 seconds) a. HV terminals kA 50 ». LV terminals ka, 50 2.20 | Minimum efficiency (at 75 °C, 50 Hz, continuous rated power, at principal tap) ‘8, power factor 1 % 99,80 . power factor 0,8 % 99,70 221 | Highest efficiency and its load point = Stage 1 (100% $1) % ( point 2.19.4) at... % | ~ Stage 2 (60% Sr) % © point 2.19.2) at... % = Stage 3 (60% Sr) % © point 2.19.4) at... % 222 | Maximum nodoad current at principal tap : a. For rated voltage %In 02 », For 105 % of rated voltage %In to be stated by bidder ©. For 110 % of rated voltage In to be stated by bidder 2.23 | Maximum no-load loss at 50 Hz, at | kW 90 30 rated volage & principal iap 2.24 | Maximum load loss at continuous fated power (75 °C, 50H2, power | factor 1) | 2.At principal ap, excluding fan kw 510 170 loss b. At minimum tap Kw to be stated by bidder At maximum tap kw tobe stated by bidder . Power for cooling fans kw 8 2 ©. Power for cooling pumps kW NA STANDARDISASI SPESIFIKAS! TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 44 J No. DESCRIPTION UNIT ‘SPECIFIED 2.25 | Hot spot factor 13 2.26 | Maximum temperature rise (refer to point 4.5 d) a. Average winding kK 55 |b. Top ail kK 50 | «. Hot spot K 68 227 | Maximum winding hot spot temperature (refer to point 1.5 d) a. Emergency overioad c 120 '. Continous loading °c 98 228 | Sound pressure level at nominal output ~ Stage 1 (100% S1), measuring 4B 66 distance 2m ~ Stage 2 (60% Sr), measuring ee NA distance 2m ~ Stage 3 (60% St), measuring eB 62 | distance 0,3 m 3 CORE 34 Core Materials (IEC 60404) a. Stee! Sheet material Grain Oriented Hi-8 silicon steel, Laser or Non Laser steel b. Name of factory of sheet steel | ‘AK Steal / POSCO Stee! / Nippon Stes! / Thyssenkrupp Steet! JFE ©. Thickness. mm 023/027 32 | Minimum Magnetic polarization for | Testa 1,85 H= 800 Am 3.3 | Maximum specific core loss at 1.7 | Wattag 0.95 | Testa, 50 Hz 34 | Maximum flux density Continuous rated power Testa 47 ». Worst emergency condition Tesla 1.88 35 | Minimum weight of core | ton to be stated by bidder STANDARDISASI SPESIFIKAS] TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 45 ia NO. DESCRIPTION UNIT ‘SPECIFIED - 4 | winoies is 41 | Conductor | ad 2. Conductor material high purity copper ». Conductor manufacturer I = HV winding ASTA/ Metrod ! Essex / Shenyang = LV winding ASTA/ Metrod / Essex / Shenyang } ¢. Minimum total conductor weight | tobe stated by bidder including insuiaton . di. Winding configuration = HV winding helical = LV winding dlse/ helical | 2. Wining insulation ~ HV winding to bo stated by bidder = LV winding tobe stated by bidder , 42 | Insulation paper os 2. Insulation material thermally upgraded kraft paper ®. Insulation paper manufacturer Weidman / Munksjé / Pucoro ¢. Class of insulation (Class A) 4. Minimum degree of 900 | polimerization after Oven process 43 | — Unitormigraded design of winding : insulation : a HV winding graded : ». LV winging uniform 44 | Winding Arrangement tobe stated by bidder | 45 | Maximum current densty | i a. HV winding Alm? 25 : ». LV winding | ave 28 , 48 | Phase connections: | a. HV winding star b. LV winding dots a STANDARDISAS! SPESIFIKAS! TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 46 No. DESCRIPTION UNIT ‘SPECIFIED 4.7 | Connection of tap changer HV windings at the neutral side 4.8 | Tap changer type De-energized Tap Changing 5 TAP CHANGER 5A Design instank mounted 52 | Type to be stated by bidder 6 on, et Main tank and on load tap changer : Uninhibited Certified Nepthanic cil type Base 62 | — Oilmanufacturer Nynas Libra / Shell $2 - ZU1/ Total Isovottine I 63 | Corrosive sulphur Non-corrosive (IEC 60296) 64 | Oilpreservation system - Rubber Bag + Maintenance free dehydrating breather ‘a. Rubber bag manufacturer Pronal / Fujikara / Musthane b, Dehydrated breather MR - MTraB /Comem manufacturer 85 | Volume of Oil (min) ki tobe stated by bidder 7 ‘TERMINATIONS 7 Termination for phases : anv oil to air bushing / oil to SF6 bushing / oil fo oil bushing bly oil to air bushing / cio oil bushing 72 | Termination for HV and LV bushings neutrals, Sa nSNEEIE DEIN RPDF ncaa oan STANDARDISASI SPESIFIKAS! TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 47 + No. DESCRIPTION UNIT SPECIFIED 73 | HVand LV bushings HV Ww a. Name of Manufacturer & Type HSP7ABB- | HSP7ABB- Micafl/ABB/ | Micafil/ ABB Alstom INGK ! HSP 1 Knobel / Comem/ Cedespe / ‘Aistom b. Insulator Porcelain Porcelain . Type of insulation Resin Condenser or Impregnated | non-condenser Paper 4. Internal conductor: tobe stated by | tobe stated by bidder bidder = Type tobe stated by | tobe stated by bidder bidder - Cross section mm* | tobe stated by | tobe stated by iddor bidder ~ Outer terminal Cylindrical stud, | Cylindrical stud with clamp ~ Material of outer terminal Copper Copper ~ Connection details Drawlead | tobe stated by bidder = Bottom contact Yes Yes - Material of bottom contact Cooper Copper ©. Highest voltage (Um, rms. wv 170 178 values) £. Rated curent Amin 1600 tobe stated by bidder 4g. Rated short-circuit current (2 KA 50 25 seconds) fh. Dry impuise withstand voltage KV 750 95 1. Switching impulse withstand kv NA NA volage |. Power-frequency test voltage 1 wv 325 38 ‘min wet (rms. values) k. Maximum dielectric dissipation % 05 NA factor (fan delta) at power frequency | Completed with test tap yes NA a STANDARDISASI SPESIFIKASI TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 48. NO. DESCRIPTION UNIT SPECIFIED 7.5 | — Bushing current transformer HV Ww a. Core 1 NA WA b. Core 2 NA NA ©. Core 3 NA NA Core 4 NA NA 77 | Neutral bushings HV | ~ Manufacturer and type FSP ABB ~ Micafl ABB - Highest voltage KV 728 8 COOLING SYSTEI | a4 Cooling method a Stage 1 (100% Sr) ‘DAF b, Stage 2 (80% Sr) ONAF ©. Stage 3 (60% Sr) ‘ONAN 82 | — Radiator mounting con tank / separate bank 83 | — Radiator height tobe stated by bidder 84 | Number of group of radiator tobe stated by bidder 85 | Number of radiator per group pes to be stated by bidder 86 | Radiator and tube bundle rust hot dip galvanized (min 40m) and protection painting 87 | Number of group of cooling fan to be stated by bidder 8.8 | Number of cooling fan per group pos to be stated by bidder 8.9 | Cooling fan motor . Nominal vottage (1ph. / 3 ph.) v 280 / 400 b, Nominal power of each motor kVA tobe stated by bidder ssa en EPRI peoe enema eee STANDARDISAS! SPESIFIKASI TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 49 1 no. | DESCRIPTION UNIT ‘SPECIFIED 8.40 | Life of cooting fan (operating hour) | hour to be stated by bidder 8.11. | Number of cooling pump NA 8.42 | Cooling pump motor NA. a. Nominal voltage (1ph. /3 ph.) v NAL b, Nominal power of each motor kVA NA «©. Operation hour counter NA 9 MAIN TANK AND ‘CONSERVATOR 4 Main tank materials a. Name of factory to be stated by bidder b. Design cover type ©. Grade of steel tobe stated by bidder 4. Thickness (top Wwallibase) mm tobe stated by bidder 92 | — Theminimum withstand-pressure of main tank : 2. Positive intemal pressure kgimm? normal pressure + 36 kPa b. Vacuum gin? Full vacuum 93 | Conservator tank design (main & oite ol separated) a. Name of factory to be stated by bidder ». eylindricalbox type cylindrical c. Grade of steel to be stated by bidder 4. Thickness (top/wallibase) mm to be stated by bidder @. Oil level indicator type magnetic type 9.4 | Conservator tank mounting a attached above main tank yes b. For delivery : separated yes 5 | Air-sealed conservator with yes dehydrated breather eee STANDARDISASI SPESIFIKAS! TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 50 NO. DESCRIPTION ONT SPECIFIED 96 Type & number of construction of to be stated by bidder oildran assembly {for of sampling, online DGA, filtering, vaccuum) 97 ‘Type and number of construction to be stated by bidder of slide valves: 98 | Type ct sealings and gaskets a. asbestos fibre to be stated by bidder ». ol-proof rubber yes 99 ‘Tank rust protection a. rust proofing yes ». marine coated painting yes c. name & type of paint to be stated by bidder 6. colour RAL 7032 9.10 Bottom base design ‘skid 10 ‘CONTROL AND INDICATION 10.1 | Marshaling box degree of iP 55 protection 402 | Control and Indication local & remote : manual & | electrical 10.3 DC Supply for control and Vde 110 indication 10.4 ‘Supply voltage for motor of fan, Vac 230/400 and pump 10.5 | Temperature monitor | a. Oil temperature oT b. Winging temperature i wn |. Hot spot temperature | fiver optic for type test unit only ee ae ‘STANDARDISASI SPESIFIKASI TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 5. "SPECIFIED NO. DESCRIPTION UNIT 10.6 Fiber optic temperature sensor for {ype test unit a. Sensor manufacturer Neoptix /Luxtron b. Sensor type / designation tobe stated by bidder ©. Completed with temperature yes monitor »b, Number of sensors Minimum 3 at each HV and LV (8 total) 11 | PROTECTION 11.4 | Buchholz relay ‘2, manufacturer & Type EMB / COMEM / Quatiro! b. waterproof contacts and yes microswitches , Maintenance Valves at both Required sides 4. Protection functions ,g88 accumulation, insulation liquid loss insulation liquid flow surge ©. Gas collector for buchhotz relay Required 11.3} Provision for fre prevention NA system 114 | Pressure Relief Device a. Type MESSKO / Qualito! », Completed with cover yes 11.5 | Ingress protection rating of relays Pee and terminals box 12 | WEIGHT AND DIMENSION 42.4 | Weight of tank and fitting ton to be stated by bidder 12.2 | Weight of active part ton tobe stated by bidder 12.3 | Maximum total weight ton tobe stated by bidder ee ‘STANDARDISAS! SPESIFIKAS| TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT 52, No. DESCRIPTION UNIT ‘SPECIFIED 12.4 | Height of the top point m to be stated by bidder 125 | Total length m to be stated by bidder 126 | Total width m to be stated by bidder 12.7 | Maximum height of iting during m tobe stated by bidder assembly or maintenance 128| Largest package - Weight ton to be stated by bidder = Dimensions (H x Lx W) mxm xm to be stated by bidder 129) Heaviest package = Weight ton to be stated by bidder = Dimensions (H x L x W) mxmxm tobe stated by bidder STANDARDISASI SPESIFIKAS! TEKNIS TRANSFORMATOR STEP UP PEMBANGKIT. 83

You might also like