EPA Office of Research and Development

Homeland Security Research

COVID-19: UVC Devices and Methods for Surface


Disinfection
HSRP Webinar Series
January 21, 2021
Lukas Oudejans, Ph.D. SEM image of SARS-CoV-2;
credit NIAID-RML
Katherine Ratliff, Ph.D.
ORD’s Center for Environmental Solutions and Emergency Response
Outline
• Background and Objectives
• Definition of UV and UVC
• Light sources and measurements
• Viruses used in study
• Experiments
• Field study with MS2 virus
• MS2 and Phi6 results
• SARS-CoV-2 results
• Conclusions
• Practical Applications/Challanges
• Next Steps

2
UVC and COVID-19
• Growing interest in UVC for surface
disinfection as a result of pandemic
• Emerging UVC products are being
widely marketed
• EPA does not register pesticide (UV)
devices
• Increasing technical support
requests for evaluating UVC
technologies (e.g., from public
transportation agencies) New York Metropolitan Transport Authority
invested $1 million on devices from Puro Lighting
for their trains and buses
3
Project Objective / Goal
Assessment of methods to disinfect challenging materials (e.g., porous
surfaces) and application methods suitable for large or complex areas
• Supplemental methods to regular surface disinfection approaches
Initial selection:
1. UV light – topic of this webinar
2. Ozone
3. Steam
Disinfection Performance Goal:
• Three (3)-log reduction* (99.9%) in viable/infective virus post-
treatment
*: Virucidal Claim: A product should demonstrate a ≥3 log10 reduction on every surface in the presence or absence of cytotoxicity. 4
- EPA 810.2200 Disinfectants for Use on Environmental Services
UV Terminology
UV spectrum UVC Action Spectrum: MS2

https://www.cleanairoptima.com/information/193/UV-Clight
Relative spectral sensitivity of MS2 Coliphage to UV light;
Beck et al. Water Research 70 (2015) 27-37

UV radiation is classified as a human carcinogen by US Department Action spectrum for SARS-CoV-2


of Health and Human Services and the World Health Organization
has not been measured (Jan 2021) 5
UVC Disinfection Research
• At start of this study, very limited data existed
on UVC disinfection against SARS-CoV-2
• Laboratory studies using various sources of UV
are now being published
• Includes some dose-response data
• Need more information for realistic field
conditions (e.g., on different materials,
inoculum type, realistic exposure conditions) 3D print of a SARS-CoV-2. Credit NIAID

• Large variability in reported efficacies due to


different test conditions

6
UVC Light Sources
Pulsed Xenon Light LED Traditional Hg Lamp

Vendors: Vendors: Vendors:


• Puro Lighting / Violet Defense • Transport Design Group • Standard UVC in Bio
• Xenex Robotic Units (TDG) and Helios Safety cabinet
• ...and many others • ...and many others Expected Use:
Expected Use: Expected Use: • Addition to regular
• Addition to regular cleaning • Addition to regular cleaning cleaning
• Build into infrastructure
• Short (<30 min) exposure • Build into metro car / office
• Long exposures (hours)
• Roll in / roll out approach • Long exposures (4-8 hrs) • Concern of containing Hg
7
Emitted Wavelengths
Characteristics: Emitted wavelengths, normalized to equal irradiance 220-300 nm
0.35

• Xenon light 0.30

• Broad wavelength spectrum,

Intensity (arb. units)


0.25

• Pulsed (msec); 1 pulse/6 sec 0.20


Hg lamp
LED
Pulsed Xenon
• LED 0.15

• 270 nm and 400 nm wavelength 0.10

• Continuous (110 mW) 0.05

• Hg
0.00
200 250 300 350 400 450 500

• 254 nm wavelength UVC


Wavelength (nm)

• Continuous Puro Light Spectrum, Courtesy of Brian Buckley, Environmental and Occupational
Health Sciences Institute, Rutgers University (September 2020)
8
Light Measurements
• UVC dose measurements are required to establish Dose measurements:
dose-response curves for the inactivation of SARS- • Dosimeter paper
CoV-2 or other viruses:
• Dose [mJ/cm2] =
Intensity [mW/cm2] x Exposure Time [s]
• Inverse Square Law:
Intensity ~ 1/r2 with • UVC Light Measurement
r the distance from
the light to the International Light
Technologies
contaminated ITL2500 meter with
SED270C or SED270
surface sensor

https://en.wikipedia.org/wiki/Inverse- 9
square_law#/media/File:Inverse_square_law.svg SED270C: 220-280 nm range
Targeted Viruses
• EPA studies have focused on:
• MS2, bacteriophage and potential surrogate for SARS-CoV-2
• Phi6, bacteriophage and potential surrogate for SARS-CoV-2
• SARS-CoV-2

• Since SARS-CoV-2 research must be conducted in a Bio


Safety Level (BSL) 3 (or higher) laboratory, research
with this virus is expensive and limited to dose
response data

• Objectives of the surrogate virus research is to assess


additional impacts of other materials and inoculum
conditions on disinfection efficacy 10
Virus Testing: Comparison*

Increasing Resistance to Inactivation


MS2 Phi6 MHV 229E SARS-CoV-2
Enveloped? No Yes Yes Yes Yes
Host Bacteria Bacteria Mice Humans Humans
(E. coli) (P. syringae)
Genus Levivirus Cystovirus Betacoronavirus Alphacoronoavirus Betacoronavirus
BSL 1 1 2 2 3
Advantage High resistance Moderate Same genus as Same Family as Actual agent of
and resistance SARS-CoV-2, non- SARS-CoV-2 COVID-19
persistence, and human pathogen
fast and easy persistence,
analysis fast and easy
analysis
11
* Credit: Dr. Worth Calfee, US EPA 11
Test Matrix
MS2 / Phi6 SARS-CoV-2

UV Light Sources Pulsed xenon, LED, Hg Pulsed xenon, LED


Materials 304 Stainless Steel 301 Stainless Steel
Glass ABS Plastic
301 Stainless Steel Bus Seat Fabric (pile;
ABS Plastic 85% wool, 15% nylon) 304 SS, glass, 301 SS, ABS plastic; 2 cm x 4 cm

Inoculum 10 µL Droplet & Spread 10 x 10 µL Droplets


Application 10 µL Droplet
Inoculum Matrix Phosphate-Buffered Tissue Culture (TC) Media
Saline (PBS) with 5% + 5% FBS &
Fetal Bovine Serum (FBS) Simulated Saliva
Inoculum Wet / Dry Droplets Wet / Dry Droplets
Presence Wet / Dry Spread
Dose Multiple (n > 10) 3 Doses / Light Source Spread vs droplet inoculum (MS2)
12
Material Inoculation

• MS2 and Phi6: Materials were A B

inoculated with viruses contained in


PBS + 5% FBS by application of
droplet(s) followed by spreading
(applies to most of MS2 and Phi6
virus research)

• SARS-CoV-2: Materials were


inoculated with virus in either TC
media or simulated saliva liquids by
application of 10 x 10 µL droplets
13 13
Experimental Setup
MS2 / Phi6 Research

SARS-CoV-2 Setup (Light source not shown)

Power/Energy
Detector Tripod with xenon light Vertical support stand

(Left) Top-Bottom: Seat fabric – ABS plastic – stainless steel

Horizontal layout 14
Virus Recovery
• Aseptic retrieval of material coupon followed by placement
into sterile conical tubes with extraction buffer
• Vortexing (2 min)
• Dilution series prepared
• MS2: Plaque assay, E. coli C-300 (ATCC 15597)
• Phi6: Plaque assay, P. syringae LM2489
• Overnight incubation (35 / 21 °C for MS2 / Phi6)
• Plaque forming unit (PFU) enumeration

• For SARS-CoV-2, samples were split with one part stored for
RV-PCR analysis (in progress)
• SARS-CoV-2 Eluents were tested for viable virus by cell culture
(Median Tissue Culture Infectious Dose, TCID50 assay)
Efficacy:
Log Reduction (LR) = Mean log10 recovery (Positive Controls) - Mean log10 recovery (Test Coupons)
15
Realistic Test Conditions
Use of UVC light to augment disinfection
practices in a metro car

16
LA Metro Field Study
• Los Angeles County Metropolitan Transport 18
Authority (LA Metro) conducted a field 16
Round 1
Round 2

study to evaluate practicality of pulsed 14

Dose (mJ/cm2)
12
xenon UVC units (ease of use, setup time, 10

durability, electrical load, functionality, etc.) 8

for two lamp configurations and achievable 4

UV dose in a metro car 2

0
A_30 A_15 B_15 B_10 B_5

• EPA supplied MS2-inoculated material Configuration_time

coupons to incorporate in this field test A_30: Config A (11 lights/car), 30 min
A_15: Config A (11 lights/car), 15 min
• LA Metro measured UV dose* for each B_15: Config B (19 lights/car), 15 min
coupon location / exposure time B_10: Config B (19 lights/car), 10 min
B_5: Config B (19 lights/car), 5 min
17
* Dose as measured with ILT SED270 light sensor in metro car (which includes UVC + UVB + UVA)
5 17
16
July 30 15 July 30 25 July 30
August 5 14 August 5 August 5
4
13
12 20

Dose (mJ/cm2)

Dose (mJ/cm2)

Dose (mJ/cm2)
11
3 10
9 15
8
2 7
6 10
5
4
1
3 5
2
1
0 0 0
A_30 A_15 B_15 B_10 B_5 A_30 A_15 B_15 B_10 B_5 A_30 A_15 B_15 B_10 B_5
Configuration_time Configuration_time Configuration_time

24
18
22
16 20
July 30 July 30
14 18
August 5 August 5
16
Dose (mJ/cm2)

Dose (mJ/cm2)

12
14
10
12
8 10

6 8
6
4
4
2
2
0
A_30 A_15 B_15 B_10
Configuration_time
B_5
0
A_30 A_15 B_15 B_10
Configuration_time
B_5
High reproducibility of doses except for Location 518
LA Metro Field Study-Results
• Measured range of doses* in LA Metro
tests: 1-22 mJ/cm2
• Lowest doses at locations outside of
direct line of sight or at large distances
• Highest dose for location at ~60” directly
in front of light, 30 min exposure time
• High reproducibility in doses between
two tests run on different days
• No significant reduction in MS2 on
coupons exposed to UVC in LA Metro test
• Additional lab tests needed to understand
this lack of virus inactivation
19
* Dose as measured with LA light sensor (ILT SED270) in metro car (which includes UVC + UVB + UVA)
Laboratory Research
MS2 and Phi6 Disinfection via UVC light

20
Initial Dose-Response Results
Puro Lighting / Violet Defense pulsed xenon light source • Positive control recoveries were >105
3.5
MS2 on Stainless Steel PFU/sample
Phi6 on Stainless Steel
Log Reduction (PFU/sample)

3.0
2.5 • UVC light inactivates MS2 and Phi6 virus
2.0
• Did not achieve 3-log reduction (“disinfection”)
1.5
1.0 • Observed non-linear relationship between
0.5 dose and log reduction for stainless steel
0.0
• Highest dose from LA Metro study:
-0.5
• ILT SED270C detector: 3.5 mJ/cm2
-1.0 • ILT SED270 detector: 22 mJ/cm2
0 10 20 30 40 50
UVC Dose (mJ/cm2) • Agreement (MS2 results) between lab study
and LA Metro field test
LA Metro dose (at ~60”, 30 min)
21
Other UVC Light Sources
Light source dependence (same stainless-steel material, 3.0
Collimated Hg Lamp
same spread inoculum with MS2 bacteriophage) 2.5

Log Reduction
PFU/sample
2.0
Pulsed Xe Light (Violet Defense / Puro) 1.5
3.0
1.0
Log Reduction (PFU/sample)

2.5 0.5
0.0
2.0 0 10 20 30 40 50 60 70 80
UVC Dose (mJ/cm2)
1.5

1.0
TDG/Helios LED Light
3.0

0.5 2.5

Log Reduction
(PFU/sample)
2.0
0.0
1.5
0 10 20 30 40 50
1.0
UVC Dose (mJ/cm2)
0.5
0.0
Nonlinear behavior appears for all three light sources 0 10 20 30 40 50 60 70 22
UVC Dose (mJ/cm2)
Other Materials
Material Dependency (same spread inoculum with MS2 bacteriophage)

Pulsed Xe Light (Violet Defense / Puro) TDG/Helios LED Light


6.0
6.0
Log Reduction (PFU/sample)

Log Reduction (PFU/sample)


5.0 5.0 dry - SS
wet - SS
4.0 4.0
wet - Glass
3.0 3.0
MS2 - SS
2.0 MS2 - Glass 2.0

1.0 1.0

0.0
0.0
0 20 40 60 80 100 120 140 0 20 40 60 80 100
UVC Dose (mJ/cm2) UVC Dose (mJ/cm2)
SS: 304 Stainless Steel
Nonlinear relation also appears for glass.
LRs for glass are noticeably higher than for stainless steel (both light sources) 23
A closeup... literally
Milled 304 Stainless Steel (MS2/Phi6 study) 301 Stainless Steel (SARS-CoV-2) Glass Coupon (MS2/Phi6 study)

24
Inoculum Start Conditions
Relevancy of dry droplet, wet droplet, or dried spread inoculum

15" Distance, 30 min exposure on Stainless Steel


Puro Light (~47 mJ/cm2 UVC)
4.0
Average Log Reduction

3.5
3.0
2.5 MS2
2.0
1.5
Phi6
1.0
0.5
0.0
*
dry dry wet
spread droplet droplet
Inoculum Condition

* To be verified in future tests


LRs are higher for wet droplet over dried droplet at start of UV light exposure; 25
Minimum impact on log reduction of the inoculum spreading
Summary MS2 and Phi6 Research
6.0
MS2 Inactivation by Pulsed Xenon Light ➢ Nonlinear dose-response behavior
Efficacy (Log10 Reduction)

5.0
304-SS appears for all three light sources and
Glass (two) materials
4.0
3.0 ➢ Relying on reported “90%” efficacy
2.0 data to get to (linear extrapolation)
1.0 99.9% “disinfection” values is
0.0 inaccurate for these test conditions
1 10 100 1000
UVC Dose (mJ/cm2)
➢ Log reductions are higher for wet droplet
4.5
Phi6 Inactivation by Pulsed Xenon Light over dried droplet; minimum impact from
the inoculum spreading
Efficacy (Log10 Reduction)

304-SS
3.5
Glass
2.5
➢ Log reductions on glass were noticeably
1.5 higher than on stainless steel (for both
0.5 UVC light sources)
-0.5
1 10 100 26
UVC Dose (mJ/cm2)
Laboratory Research
SARS-CoV-2 Disinfection via UVC light

27
Method Development

Prior to the UVC inactivation testing, we demonstrated that:


• Sufficient SARS-CoV-2 high recoveries (mid 104 PFU/coupon)
can be obtained from all materials (after drying + 1 hr)
• Lower recoveries for SARS-CoV-2 in simulated saliva (mid 103
PFU/coupon)
• No cytotoxicity of materials observed
• Based on TCID50 procedures, a detection limit of 6.3
virons/coupon was established

28
Pulsed Xenon Light Recoveries

• Positive Controls (non-exposed):


• High recoveries in TC media
• Lower recoveries in simulated saliva
• Minimal material dependence

• Test Coupons (exposed):


• Non-detects (less than 6.3 virons) in
three occasions
• Significant high recoveries for bus
seat fabric
• Higher recoveries in simulated saliva
than in TC media

29
Pulsed Xenon Light Efficacy
• Minimal reduction in viable virus for
bus seat material
• Non-smooth, porous material

• Higher (> 3 LR) efficacy on ABS plastic


and stainless steel when SARS-CoV-2
is applied in TC media

• Lower (< 3 LR) efficacy on ABS plastic


and stainless steel when SARS-CoV-2
is applied in simulated saliva
• Some of the UVC gets absorbed
in saliva (mucus and salts)

• Virus in dried inoculum is more


difficult to inactivate
30
Pulsed Xenon Light Efficacy
Puro Lighting (Pulsed Xenon) Disinfection against SARS-CoV-2 • High log reductions for smooth materials
Distance of light to surface: 30"
5
TC Media
5
Simulated Saliva
(ABS plastic and stainless steel)
Wet Droplets Wet Droplets
4 4

3
Bus Seat Fabric
3
• Low log reductions for rough, porous
ABS Plastic
Stainless Steel surface (bus seat fabric)
• Virus shielded from UVC light within
2 2

1 1
material fibers
Log Reduction

0 0
0 5 10 15 20 25 0 5 10 15 20 25
5
TC Media
5
Simulated Saliva
• SARS-CoV-2 in a dried saliva is most
4
Dry Droplets
4
Dry Droplets
difficult to inactivate.
Exposure time (min)
3 3 • Absorption of UVC in saliva may
30 60
2 2
explain this difference
7.5
1 1
• LA Metro’s highest UVC dose recorded for
0
0 5 10 15 20
0
25 0 5 10 15 20 25 a surface at 60” distance from a light and
a 30 min exposure time was 3.5 mJ/cm2
UVC Dose (mJ/cm2) 31
UVC Efficacy (First) Comparison

➢ Efficacy for bus seat fabric is low (independent of UV light source)


➢ Both UV light sources show similar efficacy in inactivating SARS-CoV-2
➢ Log reduction of dried inoculum is generally higher with pulsed xenon than LED
➢ Less than 3-log reduction for most challenging (dried saliva) condition
➢ Higher dose measurements with LED light are in progress 32
SARS-CoV-2 vs MS2
• MS2 appears to be a good
surrogate for SARS-CoV-2 for UVC
disinfection studies, with higher
efficacy observed for SARS-CoV-2
vs. MS2 under nearly same
conditions

• Difference in test conditions:


• Stainless steel surfaces are not
identical between studies
• Inoculum composition
• Droplet inoculum (SARS-CoV-2)
vs spread inoculum (MS2)

• Comparison against Phi6 in


progress (less stable virus) 33
Conclusions
➢ UVC light emitted by pulsed xenon light or LED inactivates SARS-CoV-2
and bacteriophages MS2 and Phi6
➢ Efficacy/log reductions are dependent on
• Material/substrate,
• Inoculum matrix, and
• Wet or dry droplets vs. spreading of inoculum
➢ Microscopic surface features of materials may lead to shielding and
subsequent lower efficacy of UVC inactivation
➢ MS2 appears to be a good surrogate for SARS-CoV-2 for UVC testing,
as it is slightly more difficult to inactivate
➢ The large number of variables that have an impact on efficacy makes
side by side comparisons with other disinfection studies difficult
➢ A standardized method for UVC disinfection would allow for better
evaluation and comparison of UVC light emitting devices 34
Practical Applications/Challenges
• The estimated UVC dose needed to achieve a 3-Log reduction of SARS-CoV-
2 in the conditions presented here ranges from ~ 6 mJ/cm2 to >22 mJ/cm2,
depending on multiple variables
• Such doses can only be obtained with the tested UVC light sources at
relatively short (30” or shorter) distances for operationally feasible
exposure times (<60 min)
• Longer exposure times (> 1 hr) could improve efficacy
• Additional lights at different locations may reduce shading

• UVC light is only effective where there is a direct line of sight between the
light source and the contaminated surface
• Porous materials will shield some of the virus from light, leading to only
partial inactivation
35
Next Steps

• Continue to investigate UVC to inform and improve on its application


• Address impact of other variables and
• Comparison to published log-reduction values
• Continuation of BSL-3 research with SARS-CoV-2
• UVC
• Ozone and Steam research will follow
• Additional UVC research:
• Characterization of UVC sources and UVC reflectivity with different materials
• Material compatibility tests

36
Acknowledgements
• MS2 and Phi6 studies:
• Ahmed Abdel-Hady, Mariela Monge, Denise Aslett, Dahman Touati
Jacobs Technology Inc.
• Jason Musante,
EPA Region 10

• SARS-CoV-2 studies:
• William Richter, Michelle Sunderman, Megan Howard
Battelle

• Los Angeles Metro


• Members of EPA project team
37
Points of Contact

Lukas Oudejans, Oudejans.lukas@epa.gov


Katherine Ratliff, Ratliff.Katherine@epa.gov
ORD/CESER/HSMMD

https://www.epa.gov/healthresearch/research-covid-19-environment

DISCLAIMER: The United States Environmental Protection Agency (EPA), through its Office of Research and Development, funded
and managed the research described. This presentation was peer and administratively reviewed and has been approved for
presentation as an Environmental Protection Agency document. It does not necessarily reflect the views of the Environmental
Protection Agency. No official endorsement should be inferred. This presentation includes photographs of commercially-available
products. The photographs are included for purposes of illustration only and are not intended to imply that EPA approves or endorses
the product or its manufacturer. EPA does not endorse the purchase or sale of any commercial products or services.

Data presented herein did not undergo a formal quality assurance review as outlined in “U.S. EPA Office of Research and
Development’s Quality Management Plan for Scientific Research”. If these data are included in future EPA reports or other
publications, they will be subjected to this review.
38
Backup Slides

39
Far UVC

Far UVC

https://www.cleanairoptima.com/information/193/UV-Clight

While UVC is damaging to skin and eyes, far UVC has been proposed for use in occupied
spaces as its wavelength (200-220 nm) does not appear to cause damage to skin or eyes.
However, such studies have been limited to relative short-term exposure studies.
40