Chapter 6 Maintenance and inspection
000 WARNING | VOR operation failure | The RCU can't 1) Check the cable.
communicate the OPU. | 2) Reboot the RCU.
001 WARNING | Recording stop The data recording is | When the data recording stopped to
stopping prevent overwriting data, this
message is displayed. Follow the
directions of the relevant
authorities as to whether to
restart the data recording.
About restarting the data
recording, see “4.8.4 Stopping
the recording or restarting the
recording’.
002 CAUTION | Blackout The AC input power is | 1) Check the switchboard
not supplied to the 2) Check the POWER switch. Turn
Rou. ‘on the POWER switch,
3) Cheok the AC line fuse in the
RCU. If the AC line fuse blown,
replace the fuse
003 CAUTION | Battery low voltage | The valtage af RL" | Chack the RCI hull-in battery
built-in battery is lower | Turn on the POWER switch and
than the rated value. _| charge the battery.
004 | WARNING | Fan* failure in RCU | The RCU’s builtin fan_ | It is necessary to replace the fan.
005 ate is stopping Please contact our head office, or a
nearby branch of local office to
request servicing.
008 WARNING | Battery failure The RCU's builtin itis necessary to replace the battery.
battery is deteriorating. | Ploase contact our head office, or a
nearby branch or local office to
request servicing
007 CAUTION | Battery high The temperature of | 1) Check the temperature of place
temperature RCU's built-in battery is | _ where the RCU installed.
higher than the rated | 2) Reboot the RCU and check it
value. ‘works normally If there is still a
problem, please contact our head
bffize, ut a neaiby branch or local
office to request servicing.
000 WARNING | Battery high charging | The charge voltage of | Reboot the RCU and check it works
voltage
RCU’s builtin battery io
higher than the rated
normally. If there ie etil a problem,
ploase contact our he:
office, or a
rnearhy branch ar local office to
request servicing.
95Chapter 6 Maintenance and Inspection
034 CAUTION | Time synchronization | The RCU can't receive | Check the GPS. If the GPS is
failure the ZDA sentence trom | working normally, please contact our
the GPS. head office, or a nearby branch or
local office to request servicing
044 CAUTION | OPU* communication | The RCU can't 1) Check the cable.
oa, failure communicate the OPU. | 2) Reboot the RCU.
nA
059) INFO Battery expiration date | The expiration date of | It is necessary to replace the
RCU’s built-in battery is | underwater acoustic beacon. Please
under 1 year. contact our head office, or a nearby
branch or local office to request
servicing.
060) INFO| Fixed capsule beacon | The expiration date of | itis necessary to replace the
expiration date FPC's underwater underwater acoustic beacon, Please
acoustic beacon is contact our head office, or a nearby
under 1 year. branch or local office to request
servicing.
061 INFO. Float-free capsule ‘The expiration date of | It is necessary to replace the battery,
battery expiration date | FFC’e built-in battery ie | Pleage contact our head office, or a
under 1 year. nearby branch or local office to
request servicing
082 INFO RCU fan expiration | The expiration date of | itis necessary to replace the fan.
date RCU's built-in fanis | Please contact our head office, or a
under 1 year. nearby branch or local office to
request servicing
063t0 | INFO FGU* fan expiration | The expiration date of | itis necessary to replace the fan.
065 date FGU's built-in fanis | Please contact our head office, or a
1103 under 1 year. nearby branch or local oftice to
request servicing
(086 INFO Float-free capsule HRU | The expiration date of | itis necessary to replace the
expiration date FFC'S hydrostatic hydrostatic release unit. Please
release unit is under 1 | contact our head office, or a nearby
year. branch or local office to request
servicing.
101 CAUTION | Fixed capsule short | The FPC’s data The image size may be too large
store period recording possible time | temporarily by radar echo. Check the
has decreased, gain of the radar and watch the state
for a few days.
102 WARNING | Fixed capsule The RCU can't 1) Check the cable.
connection failure
‘communicate with the
FPG.
2) Reboot the RCU.
96Chapter 6 Maintenance and Inspection
103 CAUTION | Fixed capsule The FPC can't record | Reboot the RCU.
recording failure data,
104 CAUTION | Float-free capsule ‘The FFC's data The image size may be too large
short store period recording possible time | temporarily by radar echo. Check the
has decreased. gain of the radar and watch the state
for a few days.
105 WARNING | Float-free capsule The RCU can't 1) Check the cable.
connection failure communicate the FEC | 2) Reboot the RCL
106 CAUTION. | Float-free capsule The FFC can't record | Reboot the RCU.
recordina failure data.
107 CAUTION | Internal storage short | The data recording __| The image size may be too large
store period possible time of temporarily by radar echo. Check the
internal storage has _| gain of the radar and watch the state
decreased. for a few weeks.
108 WARNING | Internal storage (No.") | The RCU's internal | Reboot the RCU and check it works
109 access failure storage can't access. | normally. If there is still a problem,
24,2 please contact our head office, or a
nearby branch or local office to
request servicing
110 CAUTION | Internal storage (No.*) |The RCU's internal | Reboot the RCU and check it works
am recording failure etorage can't rocord | normally. If there ie etill a problom,
in ata. please contact our head office, or a
nearby branch or local office to
request servicing
201 to | CAUTION. | Microphone (CH") The result of 1) Check the wiring between the
212 failure self-diagnosis test has | RCU and the microphone.
"11012 a problem, 2) In environment without a loud
noise, retry the self-diagnosis test.
See “4.5.4 Checking the audio
data”
22 WARNING | ARB initialization Reboot the RCU and check it works
« normally. If thoro ie til a problom,
please contact our head office, or a
nearby branch or local office to
request servicing.
222 WARNING | ARB control failure | There is no response of | Reboot the RCU and check it works
the ARB, normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing
97Chapter 6 Maintenance and Inspection
23 WARNING | ARB internal tailure | Ine internal error of the | Reboot the RCU and check it works
ARB is occurring, normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing,
30110 | CAUTION | Sensor reception The sensor data could | 1) Check the cable.
324 failuro (Serial CH*) _| not receive. 2) Chook the equipment that io
1 to 24 displayed.
325to | WARNING | Serial port (CH') The initialization of Reboot the RCU and check it works
4A initialization failure sensor port failed normally. If there is stil a problem,
1 to 24 please contact our head office, or a
nearby branch or local office to
request servicing,
349) WARNING | Serial port function | The initialization of Reboot the RCU and check it works
inmtanzation faiture sensor port runction _| normally. It there 1s still a problem,
failed. please contact our head office, or a
rearby biatich ur local vfs to
request servicing, -
360t0 | CAUTION | Sensor reception The sensor data of the | 1) Check the cable.
373, failure (LAN CH*) LAN can't receive. 2) Check the equipment that ie
1 to 16 displayed
37410 | WARNING | LAN port initialization | The initialization of the | Reboot the RCU
389 failure (No.*) LAN port failed.
111016
39010 | CAUTION | Sensor reception The sensor data cant | 1) Check the wiring between the
399 failure (DAU1-CH") _| receive from the DAU, RCU and the DAU.
+110 10 2) Check the witiny between the
DAU and the sensor.
3) Cheok the equipment that io
dieplayed.
400 CAUTION | Sensor reception The DAU output data | 1) Check the wiring between the
failure (DAU1-DAU) —_| can't receive RCU and the DAU
2) Check the DAU.
401 CAUTION | Sensor reception ‘The output data of 1) Check the wirina between the
tailure (VAUT-AUG) —_| AU's built-in analog RU and the DAU.
interface can't receive. | 2) Check the DAU.
402, CAUTION | Sensor reception ‘The output data of 1) Check the wiring between the
failure (DAU1-GYRO) | DAU's built-in gyro ROU and the DAU.
interface can't receive. | 2) Check the DAU.‘Chapter 6 Maintenance and Inspection
403 to | CAUTION. | Sensor reception ‘The sensor data can't | 1) Check the wiring between the
412 failure (DAU2-CH*) _| receive fromthe DAU. | RCU and the DAU.
*1t0 10 2) Check the wiring between the
DAU and the sensor.
3) Check the equipment that is
displayed
413 CAUTION | Sensor reception ‘The DAU output data 1) Check the wiring between the
failure (DAU2-DAU) —_| can't receive, RCU and the DAU,
2) Check the DAU,
414 CAUTION | Sensor reception The output data of 1) Check the wiring between the
failure (DAU2-ADC) —_| DAU’s built-in analog RCU and the DAU,
intertace can't receive. | 2) Check the DAU.
415 CAUTION. | Sensor reception The output data of 1) Check the wiring between the
fallure (DAU2-GYRO) | DAU's built-in gyro RCU and the DAU,
interface can't receive._| 2) Check the DAU.
41010 | CAUTION | Sensor reception The sensor data can't | 1) Check the wiring between the
425 failure (DAUS-Cl*) | receive fromthe DAU. | RCU and the DAU.
+1 t0 10 2) Check the wiring betwoen the
DAU and the concer.
3) Check the equipment that is
displayed
an CAUTION | Sensor reception Tha MALI output data | 1) Check the wiring between the
failure (DAU3-DAU) _ can't receive. RCU and the DAU.
2) Check the DAU.
427 CAUTION | Sensor reception ‘The output data of 1) Check the wiring between the
failure (DAU3-ADC) —_| DAU’s built-in analog RCU and the DAU.
interface can't receive._| 2) Check the DAU.
428 CAUTION | Sensor reception ‘The output data of 1) Check the wiring between the
failure (DAU3-GYRO) | DAU's built-in gyro ROU and the DAU.
interface can't receive. | 2) Check the DAU.
42910 | CAUTION | Sensor reception ‘The sensor data can't | 1) Check the wiring between the
438 failure (DAU4-CH") _| receive from the DAU. RCU and the DAU
1 to 10 2) Check the wiring between the
DAU and the sensor.
3) Check the equipment that is
displayed,
439 CAUIION. | Sensor reception The DAU output data | 1) Check the winng between the
allure (DAU4-DAU) —_| can't receive. RGU and the DAU.
2) Check the DAU.
440 CAUTION | Sensur reveption The vulpul data of 1) Check the witiny between the
failure (OAU4-ADC) | DAU's built-in analog | RCU and the DAU.
interface cant receive. | 2) Check the DAU,
99‘Chapter 6 Maintenance and Inspection
4at CAUTION. | Sensor reception The output data of 41) Check the wiring between the
failure (DAU4-GYRO) | DAU's builtin gyro RCU and the DAU,
interface can't receive. | 2) Check the DAU.
461 CAUTION. | Gyro IF uninitialization | The initial heading Set the initial heading angle
angle is not set.
501 CAUTION | S-band radarimage | The S-band radar 1) Cheek the cable.
recording failure image could not 2) Check the S-band radar.
receive,
502 CAUTION | X-band radarimage | The X-band radar 1) Check the cable.
recording failure image could not 2) Check the X-band radar.
receive,
503 CAUTION. | ECDIS image recordina | The ECDIS image 1) Check the cable.
failure could not receive. 2) Check the ECDIS.
504 WARNING | Image LAN port The initialization of | Reboot the RCU.
Intianzation failure | image LAN port failed.
91310 | INFO. Image reception failure | The display image cant | 1) Check tne cable.
920 (No.*) receive from the 2) Check the display equipment.
81108 display equipment.
§57t0 | CAUTION | FCUF fan failure | The FOU's builtin fan | itis necessary to replace the fan
559 81103 is stopping Ploase contact our head office, or a
nearby branch ar local affica to
request servicing.
560 to | WARNING | FGU* communication | The RCU cant 1) Check the LAN cable.
962 failure communicate the FGU. | 2) Reboot the FGU.
"1103 3) Reboot the RCU.
'566t0 | WARNING | FGU* control failure | There is no response of | 1) Reboot the RCU.
568 21103 the FGU, 2) Reboot the FGU.
100