You are on page 1of 6
Chapter 6 Maintenance and inspection 000 WARNING | VOR operation failure | The RCU can't 1) Check the cable. communicate the OPU. | 2) Reboot the RCU. 001 WARNING | Recording stop The data recording is | When the data recording stopped to stopping prevent overwriting data, this message is displayed. Follow the directions of the relevant authorities as to whether to restart the data recording. About restarting the data recording, see “4.8.4 Stopping the recording or restarting the recording’. 002 CAUTION | Blackout The AC input power is | 1) Check the switchboard not supplied to the 2) Check the POWER switch. Turn Rou. ‘on the POWER switch, 3) Cheok the AC line fuse in the RCU. If the AC line fuse blown, replace the fuse 003 CAUTION | Battery low voltage | The valtage af RL" | Chack the RCI hull-in battery built-in battery is lower | Turn on the POWER switch and than the rated value. _| charge the battery. 004 | WARNING | Fan* failure in RCU | The RCU’s builtin fan_ | It is necessary to replace the fan. 005 ate is stopping Please contact our head office, or a nearby branch of local office to request servicing. 008 WARNING | Battery failure The RCU's builtin itis necessary to replace the battery. battery is deteriorating. | Ploase contact our head office, or a nearby branch or local office to request servicing 007 CAUTION | Battery high The temperature of | 1) Check the temperature of place temperature RCU's built-in battery is | _ where the RCU installed. higher than the rated | 2) Reboot the RCU and check it value. ‘works normally If there is still a problem, please contact our head bffize, ut a neaiby branch or local office to request servicing. 000 WARNING | Battery high charging | The charge voltage of | Reboot the RCU and check it works voltage RCU’s builtin battery io higher than the rated normally. If there ie etil a problem, ploase contact our he: office, or a rnearhy branch ar local office to request servicing. 95 Chapter 6 Maintenance and Inspection 034 CAUTION | Time synchronization | The RCU can't receive | Check the GPS. If the GPS is failure the ZDA sentence trom | working normally, please contact our the GPS. head office, or a nearby branch or local office to request servicing 044 CAUTION | OPU* communication | The RCU can't 1) Check the cable. oa, failure communicate the OPU. | 2) Reboot the RCU. nA 059) INFO Battery expiration date | The expiration date of | It is necessary to replace the RCU’s built-in battery is | underwater acoustic beacon. Please under 1 year. contact our head office, or a nearby branch or local office to request servicing. 060) INFO| Fixed capsule beacon | The expiration date of | itis necessary to replace the expiration date FPC's underwater underwater acoustic beacon, Please acoustic beacon is contact our head office, or a nearby under 1 year. branch or local office to request servicing. 061 INFO. Float-free capsule ‘The expiration date of | It is necessary to replace the battery, battery expiration date | FFC’e built-in battery ie | Pleage contact our head office, or a under 1 year. nearby branch or local office to request servicing 082 INFO RCU fan expiration | The expiration date of | itis necessary to replace the fan. date RCU's built-in fanis | Please contact our head office, or a under 1 year. nearby branch or local office to request servicing 063t0 | INFO FGU* fan expiration | The expiration date of | itis necessary to replace the fan. 065 date FGU's built-in fanis | Please contact our head office, or a 1103 under 1 year. nearby branch or local oftice to request servicing (086 INFO Float-free capsule HRU | The expiration date of | itis necessary to replace the expiration date FFC'S hydrostatic hydrostatic release unit. Please release unit is under 1 | contact our head office, or a nearby year. branch or local office to request servicing. 101 CAUTION | Fixed capsule short | The FPC’s data The image size may be too large store period recording possible time | temporarily by radar echo. Check the has decreased, gain of the radar and watch the state for a few days. 102 WARNING | Fixed capsule The RCU can't 1) Check the cable. connection failure ‘communicate with the FPG. 2) Reboot the RCU. 96 Chapter 6 Maintenance and Inspection 103 CAUTION | Fixed capsule The FPC can't record | Reboot the RCU. recording failure data, 104 CAUTION | Float-free capsule ‘The FFC's data The image size may be too large short store period recording possible time | temporarily by radar echo. Check the has decreased. gain of the radar and watch the state for a few days. 105 WARNING | Float-free capsule The RCU can't 1) Check the cable. connection failure communicate the FEC | 2) Reboot the RCL 106 CAUTION. | Float-free capsule The FFC can't record | Reboot the RCU. recordina failure data. 107 CAUTION | Internal storage short | The data recording __| The image size may be too large store period possible time of temporarily by radar echo. Check the internal storage has _| gain of the radar and watch the state decreased. for a few weeks. 108 WARNING | Internal storage (No.") | The RCU's internal | Reboot the RCU and check it works 109 access failure storage can't access. | normally. If there is still a problem, 24,2 please contact our head office, or a nearby branch or local office to request servicing 110 CAUTION | Internal storage (No.*) |The RCU's internal | Reboot the RCU and check it works am recording failure etorage can't rocord | normally. If there ie etill a problom, in ata. please contact our head office, or a nearby branch or local office to request servicing 201 to | CAUTION. | Microphone (CH") The result of 1) Check the wiring between the 212 failure self-diagnosis test has | RCU and the microphone. "11012 a problem, 2) In environment without a loud noise, retry the self-diagnosis test. See “4.5.4 Checking the audio data” 22 WARNING | ARB initialization Reboot the RCU and check it works « normally. If thoro ie til a problom, please contact our head office, or a nearby branch or local office to request servicing. 222 WARNING | ARB control failure | There is no response of | Reboot the RCU and check it works the ARB, normally. If there is still a problem, please contact our head office, or a nearby branch or local office to request servicing 97 Chapter 6 Maintenance and Inspection 23 WARNING | ARB internal tailure | Ine internal error of the | Reboot the RCU and check it works ARB is occurring, normally. If there is still a problem, please contact our head office, or a nearby branch or local office to request servicing, 30110 | CAUTION | Sensor reception The sensor data could | 1) Check the cable. 324 failuro (Serial CH*) _| not receive. 2) Chook the equipment that io 1 to 24 displayed. 325to | WARNING | Serial port (CH') The initialization of Reboot the RCU and check it works 4A initialization failure sensor port failed normally. If there is stil a problem, 1 to 24 please contact our head office, or a nearby branch or local office to request servicing, 349) WARNING | Serial port function | The initialization of Reboot the RCU and check it works inmtanzation faiture sensor port runction _| normally. It there 1s still a problem, failed. please contact our head office, or a rearby biatich ur local vfs to request servicing, - 360t0 | CAUTION | Sensor reception The sensor data of the | 1) Check the cable. 373, failure (LAN CH*) LAN can't receive. 2) Check the equipment that ie 1 to 16 displayed 37410 | WARNING | LAN port initialization | The initialization of the | Reboot the RCU 389 failure (No.*) LAN port failed. 111016 39010 | CAUTION | Sensor reception The sensor data cant | 1) Check the wiring between the 399 failure (DAU1-CH") _| receive from the DAU, RCU and the DAU. +110 10 2) Check the witiny between the DAU and the sensor. 3) Cheok the equipment that io dieplayed. 400 CAUTION | Sensor reception The DAU output data | 1) Check the wiring between the failure (DAU1-DAU) —_| can't receive RCU and the DAU 2) Check the DAU. 401 CAUTION | Sensor reception ‘The output data of 1) Check the wirina between the tailure (VAUT-AUG) —_| AU's built-in analog RU and the DAU. interface can't receive. | 2) Check the DAU. 402, CAUTION | Sensor reception ‘The output data of 1) Check the wiring between the failure (DAU1-GYRO) | DAU's built-in gyro ROU and the DAU. interface can't receive. | 2) Check the DAU. ‘Chapter 6 Maintenance and Inspection 403 to | CAUTION. | Sensor reception ‘The sensor data can't | 1) Check the wiring between the 412 failure (DAU2-CH*) _| receive fromthe DAU. | RCU and the DAU. *1t0 10 2) Check the wiring between the DAU and the sensor. 3) Check the equipment that is displayed 413 CAUTION | Sensor reception ‘The DAU output data 1) Check the wiring between the failure (DAU2-DAU) —_| can't receive, RCU and the DAU, 2) Check the DAU, 414 CAUTION | Sensor reception The output data of 1) Check the wiring between the failure (DAU2-ADC) —_| DAU’s built-in analog RCU and the DAU, intertace can't receive. | 2) Check the DAU. 415 CAUTION. | Sensor reception The output data of 1) Check the wiring between the fallure (DAU2-GYRO) | DAU's built-in gyro RCU and the DAU, interface can't receive._| 2) Check the DAU. 41010 | CAUTION | Sensor reception The sensor data can't | 1) Check the wiring between the 425 failure (DAUS-Cl*) | receive fromthe DAU. | RCU and the DAU. +1 t0 10 2) Check the wiring betwoen the DAU and the concer. 3) Check the equipment that is displayed an CAUTION | Sensor reception Tha MALI output data | 1) Check the wiring between the failure (DAU3-DAU) _ can't receive. RCU and the DAU. 2) Check the DAU. 427 CAUTION | Sensor reception ‘The output data of 1) Check the wiring between the failure (DAU3-ADC) —_| DAU’s built-in analog RCU and the DAU. interface can't receive._| 2) Check the DAU. 428 CAUTION | Sensor reception ‘The output data of 1) Check the wiring between the failure (DAU3-GYRO) | DAU's built-in gyro ROU and the DAU. interface can't receive. | 2) Check the DAU. 42910 | CAUTION | Sensor reception ‘The sensor data can't | 1) Check the wiring between the 438 failure (DAU4-CH") _| receive from the DAU. RCU and the DAU 1 to 10 2) Check the wiring between the DAU and the sensor. 3) Check the equipment that is displayed, 439 CAUIION. | Sensor reception The DAU output data | 1) Check the winng between the allure (DAU4-DAU) —_| can't receive. RGU and the DAU. 2) Check the DAU. 440 CAUTION | Sensur reveption The vulpul data of 1) Check the witiny between the failure (OAU4-ADC) | DAU's built-in analog | RCU and the DAU. interface cant receive. | 2) Check the DAU, 99 ‘Chapter 6 Maintenance and Inspection 4at CAUTION. | Sensor reception The output data of 41) Check the wiring between the failure (DAU4-GYRO) | DAU's builtin gyro RCU and the DAU, interface can't receive. | 2) Check the DAU. 461 CAUTION. | Gyro IF uninitialization | The initial heading Set the initial heading angle angle is not set. 501 CAUTION | S-band radarimage | The S-band radar 1) Cheek the cable. recording failure image could not 2) Check the S-band radar. receive, 502 CAUTION | X-band radarimage | The X-band radar 1) Check the cable. recording failure image could not 2) Check the X-band radar. receive, 503 CAUTION. | ECDIS image recordina | The ECDIS image 1) Check the cable. failure could not receive. 2) Check the ECDIS. 504 WARNING | Image LAN port The initialization of | Reboot the RCU. Intianzation failure | image LAN port failed. 91310 | INFO. Image reception failure | The display image cant | 1) Check tne cable. 920 (No.*) receive from the 2) Check the display equipment. 81108 display equipment. §57t0 | CAUTION | FCUF fan failure | The FOU's builtin fan | itis necessary to replace the fan 559 81103 is stopping Ploase contact our head office, or a nearby branch ar local affica to request servicing. 560 to | WARNING | FGU* communication | The RCU cant 1) Check the LAN cable. 962 failure communicate the FGU. | 2) Reboot the FGU. "1103 3) Reboot the RCU. '566t0 | WARNING | FGU* control failure | There is no response of | 1) Reboot the RCU. 568 21103 the FGU, 2) Reboot the FGU. 100

You might also like