TRANSDUCER ISOLATION MEASUREMENT: OF CABLE CORES) Electronics Unit SAL R1 with RIP @ Note sv | Femme from label* transducer cable; unscrew fuse(-s)—4 to power down; | <—G@) onm-measure the transducer 3 isolation using a normal or unplug I 3 DMM (no Megger!) with a minimum power sockel~ gq Yorange 20 Mohm, as follows: Snfirste) 2 ee al gee C55 32 S st °. o g g infinite = open 3 x Across 1 - 4 circuit. : 5 wom 1 ~ 4 7 o " 23 Should read ca. 2.5-3-0 ohm. any isolation values less than 20 Mohm indicates a suspected faulty transducer and should be exchanged, The above measureaents should also be repeated with reversed polarity of the DM! Also keep fingers away from measuring points! Use proper measuring probes! Obtained values should be noted and submitted to us for information/conment If values are extrenely poor Consilium Navigation AB and the speed log system is Phone: +46-(0)8-563 051 00 inoperative there is no use Fax: +46-(0)8-563 05199 to retain functions until a E-mail: navigation@consilium.se new transducer is installed. - Xxxx_Transi 7white | 3 S/ko. 2003 -05- 15