Professional Documents
Culture Documents
Jedrus
A breakthrough
in long life,
energy efficient lighting
Energy Advantage Long Life 25W T8 System
Optanium™ Ballasts from Advance and Philips
Energy Advantage Long Life 25W T8 Lamps
The industry’s lowest energy-consuming 4-foot T8 system available. For example, two Energy Advantage Long Life
25W T8 lamps driven by a 2-lamp Optanium™ electronic ballast consumes only 43 total watts, as much as 27%
lower than a standard 32W T8 system (which draws 58–59 watts), reflecting a consumption range of only
21.5–22 watts per lamp for one, two, three or four lamp models.
2
Long lamp life
equates to lower
maintenance costs,
thereby reducing
cost-of-ownership
even further.
Photo © Z. Jedrus
Optimal System Design Delivers 36,000 Hour Rated Average Lamp Life1
Poor maintenance can result in lower light levels, “dark” fixtures, inconsistent lamping, poor color, and
employee complaints. Using the Energy Advantage Long Life 25 Watt lamp in conjunction with the
Advance High Performance Optanium Programmed start ballast extends the service cycle, which lowers
labor and material cost, and avoids work interruptions. When operated on 12-hour cycles, this system
delivers an industry leading rated average life1 of 36,000 hours, 50% longer than standard T8 lamps.
1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
3
Optimized System Warranty
Only from Philips Lighting and Advance
Energy Advantage Long Life 25W T8 lamps Energy Advantage Long Life 25W T8 lamps with
with Optanium Instant Start Electronic Ballasts
™
Optanium™ Program Start Electronic Ballasts
• Delivers long lamp life (30,000 hours rated • Delivers long lamp life (36,000 hours rated
average life at 12 hours per start)
1
average life1 at 12 hours per start)
• 2400 approximate initial lumens2 with • 2400 approximate initial lumens2 with
95% lumen maintenance 95% lumen maintenance
• Superior color rendering (85 CRI) • Superior color rendering (85 CRI)
• 30 month lamp warranty • 36 month lamp warranty
• 60 month ballast warranty3 • 60 month ballast warranty3
1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference
ballast under standard laboratory conditions.
3) Together the system further qualifies for Advance’s exclusive PLUS 90 Protection®, which adds 90 days of additional warranty protection—on both the lamps and ballasts.
For details, visit www.advancetransformer.com/support and click on “Warranty”.
4) The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure.
4
Optanium™
Ballasts,
Optimized for Instant
Start Operation
• IntelliVolt® multiple-voltage technology enables
the ballasts’ operation at any input voltage from
120 to 277 volts, 50/60Hz
• Anti-striation circuitry† eliminates flicker and
improves visual comfort
• Independent lamp operation (ILO)
• Lamp auto-restrike capability eliminates the need to
reset power mains after failed lamps are replaced
• 20-foot remote mounting/tandem wiring capability for maximum application flexibility
• UL Type CC Anti-Arc rating† protects system components in the event
of damaged sockets or poorly-seated lamps
Standard F32T8 System vs. Energy Advantage Long Life 25W T8 System
Operating on an Instant Start Ballast—3-lamp System @ .10 Per KWH
Standard F32 T8 Energy Advantage Long Life 25W T8
Standard Instant Start Ballast High-efficiency Optanium
.87 Ballast Factor (BF)1 Instant Start Electronic Ballast—.87 Ballast Factor1
CRI 78 85
Maintained 2800 x .87 2400 x .87
Lumens BF1 x .95 LM x 3 = 6943 BF1 x .95 LM x 3 = 5951
System Wattage 88 65
5
Optanium™ Ballasts,
Optimized for Programmed Start Operation
Advance’s Optanium™ Programmed Start electronic
ballasts, together with Philips Energy Advantage Long
Life 25W T8 lamps represent the industry's lowest
energy-consuming Programmed Start system as well
as the only one suitable for applications involving
frequent on/off switching or occupancy sensors.
Standard F32T8 System vs. Energy Advantage Long Life 25W T8 System
Operating on a Programmed Start Ballast—3-lamp System @ .10 Per KWH
Standard F32 T8 Energy Advantage Long Life 25W T8
Standard Instant Start Ballast High-efficiency Optanium Programmed
.87 Ballast Factor (BF)1 Start Electronic Ballast—.88 Ballast Factor1
CRI 78 85
Maintained 2800 x .87 2400 x .88
Lumens BF1 x .95 LM x 3 = 6943 BF1 x .95 LM x 3 = 6019
System Wattage 88 67
6
Outperform
T12 Systems
Replacement of existing F34T12 magnetic systems with Energy Advantage
Long Life 25W T8 lamps and High Efficiency Optanium™ Programmed
Start Ballast can deliver an energy savings of up to 60 Watts per fixture,
or over 40%! The Energy Advantage Long Life 25W T8 is ideal for office
environments that are currently
overlit with antiquated T12 lamps
and need more energy efficiency
without sacrificing light quality.
Photo © Z. Jedrus
Standard F34T12 System vs. Energy Advantage Long Life 25W T8 System
Operating on a Programmed Start Ballast—3-lamp System @ .10 Per KWH
Standard F34 T12 Energy Advantage Long Life 25W T8
Standard Instant Start Ballast High-efficiency Optanium Programmed
.88 Ballast Factor (BF)1 Start Electronic Ballast—.88 Ballast Factor1
CRI 62 85
Maintained 2650 x .88 2400 x .88
Lumens BF1 x .87 LM x 3 = 6087 BF1 x .95 LM x 3 = 6019
System Wattage 115 67
1) Ballast Factor (BF): Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast.
2) Based on 4,380 annual operating hours, 12 hours per day/7 days per week at .10¢ per KWH. Hours x KWH Rate x Watts Saved ÷ 1000.
3) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
7
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Advance
10275 West Higgins Road
Rosemont, IL 60018-5603
1-800-322-2086
A Division of Philips Electronics North America Corporation
www.philips.com
www.advancetransformer.com