3 System Accessories
Products Description
Issue Draft A
Date 2014-10-08
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Email: support@huawei.com
Change History
Date Version CR ID Modified Description Prepared By
Chapter
2014-05 AFI 3.0 X2 version
2014-09 Pre-IUS 3.0 X4 version
1. Updated information about cabinets for
base stations.
2. Updated information about cabinets for
the core network.
3. Added power unit.
4. Added DC power cabinets.
Contents
1 Cabinet....................................................................................................................................... 1
1.1 Cabinet Overview .................................................................................................................................................. 1
1.2 Cabinets for the Core Network ............................................................................................................................... 2
1.2.1 2.2 m N610E-22 Cabinet .................................................................................................................................... 2
1.2.2 1.2 m FR24611 Cabinet ...................................................................................................................................... 2
1.3 N610E-22 AC Cabinet ........................................................................................................................................... 2
1.3.1 Functions............................................................................................................................................................ 2
1.3.2 Appearance......................................................................................................................................................... 3
1.3.3 Technical Specifications...................................................................................................................................... 3
1.3.4 Certifications ...................................................................................................................................................... 4
1.3.5 AC Power Distribution Box ................................................................................................................................ 4
1.3.6 Cabinet Configuration–for eSCN230................................................................................................................... 6
1.3.7 Cabinet Configuration–for eCNS210................................................................................................................... 8
1.3.8 Cabinet Configuration–for eSCN230 and eBBU3900 .........................................................................................10
1.3.9 Cabinet Configuration–for Two eSCN230s and One eBBU3900 .........................................................................13
1.3.10 Cabinet Configuration–for eSCN231................................................................................................................15
1.4 N610E-22 DC Cabinet ..........................................................................................................................................17
1.4.1 Functions...........................................................................................................................................................17
1.4.2 Appearance........................................................................................................................................................17
1.4.3 Technical Specifications.....................................................................................................................................18
1.4.4 Certifications .....................................................................................................................................................18
1.4.5 DC Power Distribution Box ...............................................................................................................................18
1.4.6 Inverter..............................................................................................................................................................20
1.4.7 Cabinet Configuration–for eSCN230..................................................................................................................21
1.4.8 Cabinet Configuration–for eCNS210..................................................................................................................23
1.5 FR24611 AC Cabinet ............................................................................................................................................25
1.5.1 Functions...........................................................................................................................................................25
1.5.2 Appearance........................................................................................................................................................25
1.5.3 Technical Specifications.....................................................................................................................................25
1.5.4 Certifications .....................................................................................................................................................26
1.5.5 AC Power Distribution Frame ............................................................................................................................26
1.5.6 Cabinet Configuration–for eSCN230..................................................................................................................28
1.5.7 Cabinet Configuration–for eSCN230 and eBBU3900 .........................................................................................28
1.5.8 Cabinet Configuration–for eSCN231..................................................................................................................29
1.6 FR24611 DC Cabinet............................................................................................................................................30
1.6.1 Functions...........................................................................................................................................................30
1.6.2 Appearance........................................................................................................................................................30
1.6.3 Technical Specifications.....................................................................................................................................31
1.6.4 Certifications .....................................................................................................................................................32
1.6.5 DC Power Distribution Box ...............................................................................................................................32
1.6.6 Inverter..............................................................................................................................................................33
1.6.7 Cabinet Configurations ......................................................................................................................................34
1.7 ETP4830 ..............................................................................................................................................................35
1.7.1 Functions...........................................................................................................................................................35
1.7.2 Appearance........................................................................................................................................................35
1.7.3 Technical Specifications.....................................................................................................................................36
1.8 ETP48300 ............................................................................................................................................................36
1.8.1 Functions...........................................................................................................................................................36
1.8.2 Appearance........................................................................................................................................................37
1.8.3 Technical Specifications.....................................................................................................................................38
1.9 DCDU-12B Power Distribution Box .....................................................................................................................39
1.9.1 Functions...........................................................................................................................................................39
1.9.2 Technical Specifications.....................................................................................................................................39
1.10 DC Power Cabinet TP48200B.............................................................................................................................39
1.10.1 Functions.........................................................................................................................................................39
1.10.2 Appearance ......................................................................................................................................................40
1.10.3 Technical Specifications...................................................................................................................................41
1.11 Outdoor Cabinet TP48200A ................................................................................................................................41
1.11.1 Overview .........................................................................................................................................................41
1.11.2 Appearance ......................................................................................................................................................42
1.11.3 Product Specifications......................................................................................................................................42
1.12 Outdoor Battery Cabinet TBC300A ....................................................................................................................43
1.12.1 Overview .........................................................................................................................................................43
1.12.2 Appearance ......................................................................................................................................................44
1.12.3 Product Specifications .....................................................................................................................................44
1.13 Power Cabinet TP48200B ...................................................................................................................................45
1.13.1 Overview .........................................................................................................................................................45
1.13.2 Appearance ......................................................................................................................................................46
1.13.3 Product Specifications .....................................................................................................................................46
1.13.4 Battery.............................................................................................................................................................48
1.14 IMB03................................................................................................................................................................48
1.14.1 Overview .........................................................................................................................................................48
1.14.2 Appearance ......................................................................................................................................................48
1.14.3 Product Specifications .....................................................................................................................................49
1.15 Wall-Mounted Power Cabinet TP4860H..............................................................................................................50
1.15.1 Overview .........................................................................................................................................................50
1.15.2 Appearance ......................................................................................................................................................50
2 Antenna ................................................................................................................................... 55
2.1 1.8G 4PATH Antenna ...........................................................................................................................................55
2.2 1.8G 2PATH Antenna ...........................................................................................................................................55
2.3 1.4G 4PATH Antenna ...........................................................................................................................................55
2.4 1.4G 8PATH Antenna ...........................................................................................................................................57
2.5 400M 2PATH Antenna ..........................................................................................................................................59
2.6 800M 2PATH Antenna ..........................................................................................................................................60
2.7 2.3G 2PATH Antenna ...........................................................................................................................................60
2.8 2.3G 4PATH Antenna ...........................................................................................................................................60
2.9 1.8G Cylindrical Antenna (Communication Vehicle) .............................................................................................60
2.10 1.8G Whip Antenna (Communication Vehicle, Rapid) .........................................................................................62
2.11 1.4G Cylindrical Antenna 1.5 m (Communication Vehicle) ..................................................................................63
2.12 1.4G Cylindrical Antenna 1 m (Communication Vehicle) .....................................................................................64
2.13 1.4G Whip Antenna (Communication Vehicle) ....................................................................................................65
2.14 380-450M Glass Fiber Reinforced Plastics Antenna (Communication Vehicle) ....................................................66
2.15 380-450M Whip Antenna (Communication Vehicle)............................................................................................68
2.16 380-400M Glass Fiber Reinforced Plastics Antenna (Communication Vehicle) ....................................................69
2.17 380-400M Whip Antenna (Communication Vehicle)............................................................................................70
2.18 1.8G Glass Fiber Reinforced Plastics Antenna (Rapid) ........................................................................................71
2.19 380-450M Glass Fiber Antenna (Rapid) ..............................................................................................................72
2.20 380-450M Whip Antenna (Rapid) .......................................................................................................................73
3 Switch ...................................................................................................................................... 76
3.1 Quidway S5700 ....................................................................................................................................................76
3.1.1 Overview...........................................................................................................................................................76
3.1.2 Product Specifications .......................................................................................................................................76
3.1.3 Interface ............................................................................................................................................................77
3.2 Quidway S7703 ....................................................................................................................................................78
3.2.1 Overview...........................................................................................................................................................78
3.2.2 Product Specifications .......................................................................................................................................78
4 Router....................................................................................................................................... 81
4.1 AR2220 ................................................................................................................................................................81
4.1.1 Overview...........................................................................................................................................................81
4.1.2 Product Specifications .......................................................................................................................................81
1 Cabinet
Supports the front-in, back-out, and bottom-to-top ventilation modes and the
front-to-back ventilation rate is 50%, which allows the cabinet to have good heat
dissipation.
Adopts electromagnetic compatibility (EMC) in cabinet design, and provides all
interfaces with electromagnetic shielding.
Provides air filters that are installed in air vents on the front and rear doors and the
bottom plate. This prevents dust from entering the cabinet.
Uses electro-galvanized steel sheets and cold-rolled steel sheets assembled by screws.
The fireproof performance of internal materials complies with the standards of the
Underwriter Laboratories (UL).
1.3.2 Appearance
Double-swing doors are adopted by the N610E-22 AC cabinet, as shown in Figure 1-1.
Item Specifications
Rated input voltage 110 V AC/220 V AC
Dimensions (H x W x D) 2200 mm x 600 mm x 1000 mm
Capacity The inner height of the cabinet is 46 U (1 U = 44.45 mm).
Weight The weight of a pre-installed cabinet is 160 kg.
1.3.4 Certifications
Table 1-2 lists the certifications that the cabinet has passed.
Certification Description
CE Products with the CE marking comply with the electromagnetic
compatibility directive (89/336/EEC) and low voltage directive
(73/23/EEC) issued by European Commission. The CE marking is a
mandatory conformity mark for products placed on the European market.
RoHS RoHS restricts the use of certain hazardous materials in the
manufacturing of electronic and electrical equipment, in consideration of
human health and environmental protection. RoHS is enforced in each
member state of the European Union.
46
45 ACDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
37 Switch/Router
36 (S5700/S7700/AR2220)
35 Guide rail
34
33 Filler panel
32
31
30 Filler panel
29
28
27 Filler panel
26
25
eSCN230 (2U)
24 Guide rail
23 Cable trough
22
eSCN230 (2U)
21 Guide rail
20 Cable trough Guide rail
19 AC/DC
18 (ETP4830-A1/ETP48300-A2) Guide rail
17 Filler panel
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10 guide rail
9 Filler panel
Non-standard
8 PSTN gateway guide rail
7 Cable trough Guide rail
Non-standard
6 Filler panel guide rail
5 Filler panel
4 Trunking gateway Guide rail
3 Filler panel Guide rail
2
Filler panel Non-standard
1 guide rail
46
45 ACDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
Switch/Router
37
(S5700/S7700/AR2220)
36
35 Guide rail
34
33
32
31
30
29
28
eCNS210 (14U)
27
26
25
24
23
22
21 Guide rail
20 Cable trough Guide rail
19 AC/DC
18 (ETP4830-A1/ETP48300-A2) Guide rail
17 Filler panel
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10 guide rail
9 Filler panel
Non-standard
8 PSTN gateway guide rail
7 Cable trough Guide rail
Non-standard
6 Filler panel guide rail
5 Filler panel
4 Trunking gateway Guide rail
3 Cable trough Guide rail
2
Filler panel Non-standard
1 guide rail
46
45 ACDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
37 Switch/Router
36 (S5700/S7700/AR2220)
35 Guide rail
34
33 Filler panel
32
31 Filler panel
30 DCDU (1U)
29 Cable trough Guide rail
28
27 Filler panel
26
25
eSCN230 (2U)
24 Guide rail
23 Cable trough
22
eBBU3900 (2U)
21 Guide rail
20 Filler panel Guide rail
19 AC/DC
18 (ETP4830-A1/ETP48300-A2) Guide rail
17 Filler panel
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10
guide rail
9 Filler panel
Non-standard
8 PSTN gateway
guide rail
7 Cable trough Guide rail
Non-standard
6 Filler panel
guide rail
5 Filler panel
4 Trunking gateway Guide rail
3 Filler panel Guide rail
2
Filler panel Non-standard
1
guide rail
Figure 1-7 Cabinet configuration diagram (two eSCN230s and one eBBU3900)
46
45 ACDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
37 Switch/Router
36 (S5700/S7700/AR2220)
35 Guide rail
34
33 Filler panel
32
31 Filler panel
30 DCDU (1U)
29 Cable trough
28
eSCN230 (2U)
27 Guide rail
26 Filler panel
25
eSCN230 (2U)
24 Guide rail
23 Cable trough
22
eBBU3900 (2U)
21 Guide rail
20 Filler panel Guide rail
19 AC/DC
18 (ETP4830-A1/ETP48300-A2) Guide rail
17 Filler panel
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10
guide rail
9 Filler panel
8 PSTN gateway Non-standard
guide rail
7 Cable trough Guide rail
6 Filler panel Non-standard
guide rail
5 Filler panel
4 Trunking gateway Guide rail
3 Filler panel Guide rail
2
Filler panel Non-standard
1
guide rail
46
45 ACDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
37 Switch/Router
36 (S5700/S7700/AR2220)
35 Guide rail
34
33 Filler panel
32
31 Filler panel
30 DCDU (1U)
29 Cable trough Guide rail
28
27 Filler panel
26
25
24 Filler panel
23
22
eSCN231 (2U)
21 Guide rail
20 Cable trough Guide rail
19 AC/DC
18 (ETP4830-A1/ETP48300-A2) Guide rail
17 Filler panel
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10 guide rail
9 Filler panel
Non-standard
8 PSTN gateway guide rail
7 Cable trough Guide rail
Non-standard
6 Filler panel guide rail
5 Filler panel
4 Trunking gateway Guide rail
3 Filler panel Guide rail
2
Filler panel Non-standard
1 guide rail
1.4.2 Appearance
Double-swing doors are adopted by the N610E-22 DC cabinet, as shown in Figure 1-9.
Item Specifications
Rated input voltage -48 V DC (-48 V DC by default)
Dimensions (H x W x D) 2200 mm x 600 mm x 1000 mm
Capacity The inner height of the cabinet is 46 U (1 U = 44.45 mm).
Weight The weight of a pre-installed cabinet is 178 kg.
1.4.4 Certifications
Table 1-5 lists the certifications that the cabinet has passed.
Certification Description
CE Products with the CE marking comply with the electromagnetic
compatibility directive (89/336/EEC) and low voltage directive
(73/23/EEC) issued by European Commission. The CE marking is a
mandatory conformity mark for products placed on the European market.
RoHS RoHS restricts the use of certain hazardous materials in the
manufacturing of electronic and electrical equipment, in consideration of
human health and environmental protection. RoHS is enforced in each
member state of the European Union.
1.4.6 Inverter
A DC/AC inverter is used to convert the DC power to AC power and provide power for AC
devices.
The DC/AC inverter is applicable to different scenarios where continuous AC power is
required. Functions of the DC/AC inverter are as follows:
Converts the -48 V DC power to 220 V AC power.
Provides overvoltage and undervoltage protections for the input power.
Provides overvoltage and undervoltage protections for the output power.
Provides overload and short circuit protections for the loads.
Provides high temperature protections.
The height of a DC/AC inverter is 1U. Figure 1-11 shows the front panel of a DC/AC inverter.
46
45 DCDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
37 Switch/Router
36 (S5700/S7700/AR2220)
35 Guide rail
34
33 Filler panel
32
31
30 Filler panel
29
28
27 Filler panel
26
25
eSCN230 (2U)
24 Guide rail
23 Cable trough
22
eSCN230 (2U)
21 Guide rail
Non-standard
20 Inverter 1 guide rail
19 Cable trough
18 Inverter 0 Guide rail
17 Cable trough Guide rail
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10 guide rail
9 Filler panel
Non-standard
8 Inverter 2 guide rail
7 Cable trough Guide rail
Non-standard
6 PSTN gateway guide rail
5 Cable trough Guide rail
Non-standard
4 Trunking gateway guide rail
3 Filler panel Guide rail
2
Filler panel Non-standard
1 guide rail
46
45 DCDU
44 Guide rail
43
42
Reserved
41
40 Guide rail
39 Cable trough Guide rail
38
37 Switch/Router
36 (S5700/S7700/AR2220)
35 Guide rail
34
33
32
31
30
29
28
eCNS210 (14U)
27
26
25
24
23
22
21 Guide rail
Non-standard
20 Inverter 1 guide rail
19 Cable trough
18 Inverter 0 Guide rail
17 Cable trough Guide rail
16 SERVER1 (DELL R620/DELL
15 R820/HW1288/HW2485)
14 SERVER2 (DELL R620/DELL
13 R820/HW1288/HW2485)
12 SERVER3 (DELL R620/HW2288)
11
Disk array (DELL MD1220) Non-standard
10 guide rail
9 Filler panel
Non-standard
8 Inverter 2 guide rail
7 Cable trough Guide rail
Non-standard
6 PSTN gateway guide rail
5 Cable trough Guide rail
Non-standard
4 Trunking gateway guide rail
3 Cable trough Guide rail
2
Filler panel Non-standard
1 guide rail
1.5.2 Appearance
The FR24611 cabinet is equipped with double-swinging doors at the back and a left swinging
door at the front. Figure 1-15 shows the appearance of the cabinet.
Item Specifications
Rated input voltage 220 V AC/110 V AC (single phase)
Dimensions (H x W x D) 1200 mm x 600 mm x 1100 mm
Capacity The inner height of the cabinet is 24 U (1 U = 44.45 mm).
Weight The weight of a pre-installed cabinet is 220 kg.
1.5.4 Certifications
Table 1-9 lists the certifications that the cabinet has passed.
Certification Description
CE Products with the CE marking comply with the electromagnetic
compatibility directive (89/336/EEC) and low voltage directive
(73/23/EEC) issued by European Commission. The CE marking is a
mandatory conformity mark for products placed on the European market.
RoHS RoHS restricts the use of certain hazardous materials in the
manufacturing of electronic and electrical equipment, in consideration of
human health and environmental protection. RoHS is enforced in each
member state of the European Union.
There are 24 switches on the front panel of the AC PDB. The switches are divided into group
A and group B, with 12 switches in each group. The switches are numbered with SW1 to
SW12 from left to right. The current of each switch is 16 A.
Table 1-10 lists the technical specifications of the AC PDB.
24U
23U ACDU
22U Guide rail
Non-standard
21U Switch/Router (S5700/AR2220) guide rail
20U Cable trough Guide rail
19U Filler panel
18U Filler panel Guide rail
17U
eSCN230 (2U)
16U Guide rail
15U Cable trough Guide rail
14U AC/DC
13U (ETP4830-A1/ETP48300-A2) Guide rail
12U SERVER1 (DELL R620/HW1288)
11U SERVER2 (DELL R620/HW1288)
10U
SERVER3 (DELL R620/HW2288)
9U
Non-standard
8U PSTN gateway guide rail
7U Cable trough Guide rail
6U Filler panel
5U Trunking gateway Guide rail
4U Filler panel Guide rail
3U Cable trough Guide rail
2U
Filler panel Non-standard
1U guide rail
In addition, the cabinet can house one eOMC server, one dispatcher, one trunking gateway,
one PSTN gateway, and one multimedia recording server. If one eSCN230 + one eBBU3900
are configured, the cabinet can house at most one switch (optional).
Figure 1-18 shows the positions of devices in the cabinet.
24U
23U ACDU
22U Guide rail
Non-standard
21U Switch/Router (S5700/AR2220)
guide rail
20U Cable trough Guide rail
19U
eBBU3900 (2U)
18U Guide rail
17U
eSCN230 (2U)
16U Guide rail
15U Cable trough Guide rail
14U AC/DC
13U (ETP4830-A1/ETP48300-A2) Guide rail
12U SERVER1 (DELL R620/HW1288)
11U SERVER2 (DELL R620/HW1288)
10U
SERVER3 (DELL R620/HW2288)
9U
Non-standard
8U PSTN gateway
guide rail
7U Cable trough Guide rail
6U Filler panel
5U Trunking gateway Guide rail
4U DCDU (1U) Guide rail
3U Cable trough Guide rail
2U
Filler panel Non-standard
1U
guide rail
24U
23U ACDU
22U Guide rail
Non-standard
21U Switch/Router (S5700/AR2220) guide rail
20U Cable trough Guide rail
19U
eSCN231 (2U)
18U Guide rail
17U Filler panel
16U Filler panel Guide rail
15U Cable trough Guide rail
14U AC/DC
13U (ETP4830-A1/ETP48300-A2) Guide rail
12U SERVER1 (DELL R620/HW1288)
11U SERVER2 (DELL R620/HW1288)
10U
SERVER3 (DELL R620/HW2288)
9U
Non-standard
8U PSTN gateway guide rail
7U Cable trough Guide rail
6U Filler panel
5U Trunking gateway Guide rail
4U DCDU (1U) Guide rail
3U Cable trough Guide rail
2U
Filler panel Non-standard
1U guide rail
1.6.2 Appearance
The FR24611 cabinet is equipped with double-swinging doors at the back and a left swinging
door at the front. Figure 1-20 shows the appearance of the cabinet.
Item Specifications
Rated input voltage -48 V DC
Dimensions (H x W x D) 1200 mm x 600 mm x 1100 mm
Capacity The inner height of the cabinet is 24 U (1 U = 44.45 mm).
Weight The weight of a pre-installed cabinet is 205 kg.
1.6.4 Certifications
The following table lists the certifications that the cabinet has passed.
Certification Description
CE Products with the CE marking comply with the electromagnetic
compatibility directive (89/336/EEC) and low voltage directive
(73/23/EEC) issued by European Commission. The CE marking is a
mandatory conformity mark for products placed on the European market.
RoHS RoHS restricts the use of certain hazardous materials in the
manufacturing of electronic and electrical equipment, in consideration of
human health and environmental protection. RoHS is enforced in each
member state of the European Union.
1.6.6 Inverter
A DC/AC inverter is used to convert the DC power to AC power and provide power for AC
devices.
The DC/AC inverter is applicable to different scenarios where continuous AC power is
required. Functions of the DC/AC inverter are as follows:
Converts the -48 V DC power to 220 V AC power.
Provides overvoltage and undervoltage protections for the input power.
Provides overvoltage and undervoltage protections for the output power.
Provides overload and short circuit protections for the loads.
Provides high temperature protections.
The height of a DC/AC inverter is 1U. Figure 1-22 shows the front panel of a DC/AC inverter.
24U
23U DCDU
22U Guide rail
Non-standard
21U Switch/Router (S5700/AR2220) guide rail
20U Cable trough Guide rail
19U Filler panel
18U Filler panel Guide rail
17U
eSCN230 (2U)
16U Guide rail
15U Cable trough Guide rail
Non-standard
14U Inverter 0 guide rail
13U Cable trough Guide rail
12U SERVER1 (DELL R620/HW1288)
11U SERVER2 (DELL R620/HW1288)
10U
SERVER3 (DELL R620/HW2288)
9U
Non-standard
8U PSTN gateway guide rail
7U Cable trough Guide rail
6U Filler panel
5U Trunking gateway Guide rail
Non-standard
4U Inverter 1 guide rail
3U Cable trough Guide rail
2U
Filler panel Non-standard
1U guide rail
1.7 ETP4830
1.7.1 Functions
An ETP4830 is applicable to scenarios where an eSCN230 is installed in an AC cabinet. An
AC/DC converter converts 220 V AC power into –48 V DC power, and provides power to DC
devices in an AC cabinet.
Supports one or two power supply units (PSUs) and converts AC to –48 V DC.
Supports one power monitoring unit (PMU) that monitors operating parameters in real
time, determines working status, and reports alarms.
1.7.2 Appearance
Figure 1-25 shows the appearance of an ETP4830 AC/DC converter.
1.8 ETP48300
1.8.1 Functions
An ETP48300 is applicable to scenarios where one eCNS210, one eSCN230 + one
eBBU3900, one eSCN231, or two eSCN230s + one eBBU3900 are configured. An AC/DC
converter converts 220 V AC power into –48 V DC power, and provides power to DC devices
in an AC cabinet.
1.8.2 Appearance
Figure 1-26 shows the appearance of an ETP48300 AC/DC converter.
Parameter Specifications
Function A DCDU-12B is supplied with one -48 V DC power input, provides
seven -48 V DC power outputs for supplying power to eBBUs, RRUs,
and eSCN230s.
Input current > 100 A
DC output Supplies three channels of DC outputs to eRRUs.
Supplies four channels of DC outputs to eBBUs and eSCN230s.
Huawei AC/DC power cabinet TP48200B supports single-phase 100 V to 240 V AC and
dual-live-wire 110 V AC power inputs.
A TP48200B is used in indoor scenarios and uses a 48 V/50 A PSU. A TP48200B supplies
stable and reliable DC power to –48 V communication devices, and provides a comprehensive
battery management function. The TP48200B applies to various indoor scenarios based on the
number of PSUs.
1.10.2 Appearance
The TP48200B consists of the cabinet, PSU, monitoring unit, power distribution unit, user
space, and battery. The dimension of a TP48200B is 600 mm x 600 mm x 2000 mm, as shown
in Figure 1-28.
The protection level of the TP48200B is IP20. It can be mounted on the ground and operated
in front of it.
Parameter Specifications
Cabinet dimensions (H x W x D) 2000 mm x 600 mm x 600 mm
Number of modules 2 to 4
Cable layout Cables are routed into and out of the cabinet top.
Protection level IP20
Parameter Specifications
Operating temperature -20ºC to +50ºC (short-term operating temperature:
50ºC to 55ºC)
Cooling Forced air cooling
Operating humidity 5% to 95%
Transport temperature -40ºC to +70ºC
Storage temperature -40ºC to +70ºC
Storage humidity 5% to 95%
Altitude 0-4000 m (In the range of 2000 m to 4000 m, the
operating temperature decreases by 1ºC when the
altitude increases by 200 m.)
1.11.2 Appearance
The following figure shows the appearance of a TP48200A.
Name TP48200A-HX09A5
Input mode Three-phase four-wire 220/380 V AC input, compatible with
single-phase 220 V AC
Input voltage 85 V AC to 300 V AC
Input frequency Frequency range: 45 to 66 Hz; nominal frequency: 50/60 Hz
AC distribution AC input circuit breaker: 1 x 63 A/3P
AC output circuit breaker: 1 x 16 A/1P, 1 x SOU (16 A protection
circuit breaker)
Temperature The heat exchange or direct ventilation mode is selected according to
control unit the site survey.
Output voltage -42 V DC to -58 V DC; default value: -53.5 V DC
Name TP48200A-HX09A5
DC distribution BLVD: 2 x 16 A/1P, 1 x 10 A/1P (The 10 A switch supplies power to
the TCUC in the battery cabinet.)
LLVD: 2 x 63 A/1P, 2 x 32 A/1P
Battery tributary: 2 x 125 A/1P
Surge protector AC surge protection: The nominal discharge current is 20 kA; the
maximum discharge current is 40k A, 8/20 μs.
DC surge protection: 10 kA in differential mode, 20 kA in common
mode, 8/20 μs
PSU A maximum of four R4850G6s or R4850N2s
Applicable Type C (heat exchange) or type B (direct ventilation)
environment
Cabinet 900 mm x 650 mm x 650 mm (excluding the base and the protruding
dimensions (H x part)
W x D)
Space 11 U
Operating Heat exchange type: -40ºC to +45ºC + solar radiation 1120 W/m2
temperature Direct ventilation type: -10ºC to +45ºC + solar radiation 1120 W/m2
Operating 5% to 95% (RH), without condensation
humidity
Altitude 0-4000 m (In the range of 2000 m to 4000 m, the operating
temperature decreases by 1ºC when the altitude increases by 200 m.)
Type B environment: refers to uncontrolled environments, that is, indoor environments where
the temperature and humidity cannot be controlled, or common outdoor environments,
including those with only simple veils, such as an awning, and environments whose humidity
may reach 100% occasionally.
Type C environment: refers to the sea environment, terrestrial environment beside a pollution
source, or environment that has only simple veils, such as an awning. The environment beside
a pollution source refers to areas within the following radius: 3.7 km to salt water such as
oceans and salt lakes; 3 km to heavy pollution sources such as metallurgical refineries, coal
mines, and power plants; 2 km to medium pollution sources such as chemical plants, rubber
plants, and electroplating workshops; 1 km to light pollution sources such as food-processing
factories, fur and leather processing factories, and heating boilers.
1.12.2 Appearance
A TBC300A is compact, lightweight, and easy to transport. The following figure shows the
appearance of a TBC300A.
Name TBC300A
Cabinet dimensions (H 900 mm x 650 mm x 650 mm (excluding the base and the
x W x D) protruding part)
Operating temperature Varies based on the cabinet model: -10ºC to +45ºC + solar
radiation 1120 W/m2
Or -40ºC to +45ºC + solar radiation 1120 W/m2
Type B environment: refers to uncontrolled environments, that is, indoor environments where
the temperature and humidity cannot be controlled, or common outdoor environments,
including those with only simple veils, such as an awning, and environments whose humidity
may reach 100% occasionally.
Type C environment: refers to the sea environment, terrestrial environment beside a pollution
source, or environment that has only simple veils, such as an awning. The environment beside
a pollution source refers to areas within the following radius: 3.7 km to salt water such as
oceans and salt lakes; 3 km to heavy pollution sources such as metallurgical refineries, coal
mines, and power plants; 2 km to medium pollution sources such as chemical plants, rubber
plants, and electroplating workshops; 1 km to light pollution sources such as food-processing
factories, fur and leather processing factories, and heating boilers.
The TP48200B consists of the cabinet, PSU, monitoring unit, power distribution unit, user
space, and battery.
1.13.2 Appearance
The dimensions (H x W x D) of a TP48200B are 2000 mm x 600 mm x 600 mm, as shown in
the following figure.
The protection level of the TP48200B is IP20. It can be mounted on the ground and operated
in front of it.
Name TP48200-N20B2
Cable layout Cables are routed into and out of the cabinet top.
Maintenance Operated and maintained from the front (distance from a wall ≥ 100 mm)
Altitude 0 to 4000 m
1.13.4 Battery
A TP48200B supports a maximum of two 150 Ah valve regulated lead acid batteries for
power backup, as shown in the following figure.
1.14 IMB03
1.14.1 Overview
The indoor mini box 03 (IMB03) is used indoors. It provides a 3 U space for installing
equipment such as eBBU, ETP48100-B1, or DCDU-12B. An ETP48100-B1 or a DCDU-12B
can be configured for an IMB03 to support -48 V DC or 220 V AC input.
1.14.2 Appearance
The IMB03 is characterized by its flexible installation, satisfactory heat dissipation, and easy
cabling. It can be supplied with DC or AC power. Figure 1-31 shows the interior of an
IMB03.
Parameter Specifications
Weight ≤ 12 kg
Dimensions (H x W x D) 560 mm x 180 mm x 425 mm
Space 3U
Operating temperature -20ºC to 50ºC
Protection level IP20
Input feature Single-phase 220 V AC: 176 V to 290 V
-48 V DC: -38.4 V to -57 V
Heat dissipation 650 W heat dissipation capability
Installation mode Wall mounting
220 V AC input: If the space in the equipment room is insufficient, the IMB03 can be
mounted on a wall. If no backup power is required, the IMB03 implements AC/DC
conversion using a built-in ETP48100-B1 and an eBBU, to supply power to the eBBU. An
ETP48100-B1 can connect to at most three RRUs. When the BBU has two UPEU power
boards, it can connect to only two RRUs).
-48 V DC input: If the space in the equipment room is insufficient, the IMB03 can be
mounted on a wall. The IMB03 works with a built-in DCDU-12B and an eBBU. The
DCDU-12B supplies power to the eBBU and a maximum of six RRUs. Currently, IMBs use
16 mm2 power cables, so support only six RRUs.
1.15.2 Appearance
Figure 1-32 shows the dimensions of a TP4860H.
1.16 OMB
The outdoor mini box (OMB) is also called the outdoor eBBU subrack. The OMB cabinet can
house and supply power to an eBBU on a distributed base station DBS3900, and provides
power to a DC RRU, without backup power. The OMB is classified into the DC type and AC
type, and can house an eBBU3900, AC/DC power devices, DCDU, and transmission devices.
The OMB is characterized by its easy cabling, protection against water, dust, and sunlight,
and proper grounding.
1.16.1 AC OMB
An AC OMB is an outdoor heat exchange cabinet, and provides 2U space for installing an
indoor case-shaped BBU3900. The built-in AC/DC converter converts 220 V AC power to
–48 V DC power, and supplies DC power to one BBU3900 and a maximum of three RRUs.
Figure 1-33 shows the appearance of an OMB.
Parameter Specifications
Function An AC OMB provides 2U space for installing indoor case-shaped
devices. The built-in AC/DC converter converts 220 V AC power to
–48 V DC power, and supplies DC power to one BBU3900 and a
maximum of three RRUs.
Input current One 220 V AC input is available. The input power cable is 4 mm2, and
20 A (one PSU) or 32 A (two PSUs) AC circuit breakers are used.
Currently, only one PSU is configured.
Parameter Specifications
Power Has a built-in AC/DC power supply ETP48100-A1, providing 10 x 30
distribution A outputs. LOAD 0-5: connect to RRUs, and support a maximum of 16
specification mm2 cable diameter; LOAD 6-8: connect to the BBU and fan module,
and support a maximum of 4 mm2 cable diameter.
Weight The weight of a fully configured OMB is less than 30 kg.
Dimensions (H x 600 mm x 240 mm x 430 mm
W x D)
Operating -33ºC to 50ºC
temperature
Space 2U
Surge protection AC input: rated value: 20 kA; maximum value: 40 kA; 8/20 us
capability DC output: differential mode: 10 kA; common mode: 20 kA; 8/20 us
Typical The protection class is IP55. An AC OMB is typically used outdoors to
application house a BBU and supply power to the BBU and a maximum of three
scenario RRUs. It can also be used in AC input scenarios with limited indoor
installation space and stringent installation conditions, such as
weak-current wells.
Installation mode An OMB can be installed on a wall or pole. In the OMB, a BBU is
installed using mounting ears.
1.16.2 DC OMB
A DC OMB is an outdoor heat exchange cabinet, and provides 3U space for installing indoor
case-shaped devices. The built-in DCDU supplies DC power to one BBU, one transmission
device, and a maximum of six RRUs.
Figure 1-34 shows the appearance of a DC OMB.
The total heat consumption of the built-in BBU in a DC OMB must not exceed 450 W. The
following table lists the specifications of an OMB.
Parameter Specifications
Function A DC OMB provides 3U space for installing indoor case-shaped
devices. The built-in DCDU supplies DC power to one BBU, one
transmission device, and a maximum of six RRUs.
Input voltage 1 x -48 V DC input
Power distribution Provides 10 x 30 A outputs. LOAD 0-5: connect to RRUs, and
support a maximum of 16 mm2 cable diameter; LOAD 6-8: connect
to the BBU, fan module, and transmission device, and support a
maximum of 4 mm2 cable diameter.
Weight The weight of a fully configured OMB is less than 30 kg (excluding
the weight of the transmission device).
Dimensions (H x W 600 mm x 240 mm x 430 mm
x D)
Operating -33ºC to 50ºC
temperature
Space 3U
Maximum device 450 W
power consumption
Parameter Specifications
Surge protection DC output: differential mode: 10 kA; common mode: 20 kA; 8/20
capability us
Typical application The protection class is IP55. A DC OMB is typically used outdoors
scenario to house a BBU and supply power to the BBU and a maximum of
six RRUs. It can also be used in AC input scenarios with limited
indoor installation space and stringent installation conditions, such
as weak-current wells.
Installation mode An OMB can be installed on a wall or pole. In the OMB, a BBU is
installed using mounting ears.
2 Antenna
Appearance
Appearance
Type TQC-1800A
Frequency (MHz) 1710 to 1990
Gain (dBi) 7
Standing wave ratio ≤ 1.5
Input impedance (Ω) 50
Type TQC-1500A
Frequency (MHz) 1400 to 1550
Operating width (MHz)
40
Polarization Vertical
Maximum input power (W) 100
Connector type SL16-J
Antenna length (mm) 405 (Maybe change slightly along with the
central frequency)
Antenna weight (g) 60 (Maybe change slightly along with the
central frequency)
Appearance
3 Switch
3.1.3 Interface
S5700-28C-EI supports a maximum of 28 interfaces, including twenty-four 10/100/1000
BASE-T Ethernet interfaces and four front subcard slots.
S5700-28C-EI supports a maximum of 28 interfaces, including twenty-four
100/1000BASE-X Ethernet optical interfaces and four GE combo interfaces
(10/100/1000BASET+100/1000BASEX, used together with the last four Ethernet interfaces)
Component Description
MCU The MCUs are installed in slot 4 and slot 5 and work in 1:1 backup
mode. The interval between slot 4 and slot 5 is 0.8 inches.
LPU The LPUs are installed in slots 1-3. The interval between each two
slots is 1.4 inches.
Fan module The fan modules are installed at the rear of the equipment. The
equipment must be equipped with one fan module.
PWR The power supplies are installed in slots PWR1 and PWR2. The S7703
can use DC or AC power supplies.
Cable tray The cable distribution posts are located on the right side of the board
cage of the S7703.
Cable The cables of the S7703 include internal cables (such as power cables
and signal cables), optical fibers, and external cables.
4 Router
4.1 AR2220
4.1.1 Overview
Developed by Huawei, AR 2220 is the next-generation routing and gateway device, which
provides the routing, switching, wireless, voice, and security functions.
Currently, the configurations only map KDC server NEs (not involving the KDC or KDC
agent), and support the interconnection with software on other NEs. Mapping information
about the corresponding cabinets and power distribution is not provided. Detailed site
mapping information is provided in specific projects.