User Manual of Drilling Fluid Circulating Manifold
Contents
I
User Manual of Drilling Fluid Circulating Manifold
1. Safety warnings
Only trained and qualified persons can install, operate and maintain equipment with
qualification certificates.
Operators must read related operation manuals before operation, and can operate or
maintain equipment after the familiarity with its functions and operation.
There shall be a chief principal designated for installation and maintenance, the
persons participating in work shall be assigned with clear work, and detailed and
reliable safety measures shall be available.
In the operation process, strictly execute its operation specifications and follow
technical safety rules.
Do not run equipment in the dark except that there are proper lighting facilities.
The used lifter and handling equipment must adapt to related weight to be operated.
Make sure to release pressure to zero in disconnection of any high pressure pipelines
or hoses. Follow similar procedures in wiring of electric appliances and make sure to
cut off power supply before trying repair.
3. Standards
SY/T5244 Drilling Fluid Circulating Manifold
1
User Manual of Drilling Fluid Circulating Manifold
th
API 7K, 5 edition, Specification for Drilling and Well Service Equipment
4. Technical parameters
Nominal diameter: 4″
Maximum working pressure: 35MPa
Water pressure test for strength: 53MPa
Temperature grade: PU
Height of gooseneck: 17.5m; 21.5m
Length of rotary hose: 19m; 23m
Weight: 11866 kg
Working medium: clear water, drilling fluid, fracturing fluid and crude oil
2
User Manual of Drilling Fluid Circulating Manifold
3
User Manual of Drilling Fluid Circulating Manifold
4
User Manual of Drilling Fluid Circulating Manifold
circulation, its operation procedure is as follows (Fig. II):
(1) In the drilling circulation operation with 1# drilling pump, open gate valves 3, 5,
11,12, or 3, 5, 11, 10, 9, close other gate valves. In the drilling circulation operation with 2, 3#
drilling pump, do it similarly.
(2) In the drilling circulation operation with 1#, 2# and 3# drilling pumps, open gate
valves 1, 2, 3, 4, 6, 7, 8, 9, or 1, 2, 3, 5, 6, 7, 11 and 12, close other gate valves.
8.2 It is simple and convenient to use ZG127-35S drilling fluid circulating manifold.
During repair, remove all unions of connecting parts, and check union threads, O-ring and all
components; if O-ring is damaged, replace with a new one, then grease connecting union
threads and tighten the unions. Replace O-ring after each removal. Ensure that there is no
leakage during use. Perform antiseptic treatment on manifolds which is used for some time.
5
User Manual of Drilling Fluid Circulating Manifold
Thus, the service life of the manifolds is prolonged.
9. Lubrication
9.1 The lubrication of mud gate valve shall be carried out as per the instruction of its
valve.
9.2 The lubrication of union connection surface: 2# lithium base grease.
10. Maintenance
10.1 After each well is drilled, check split pins for damage, if any, replace them;
10.2 Check corrosion of all pipes half a year, if the corrosion is obvious, measure
thickness with ultrasonic wave, and then replace the pipes the measured thickness of which is
less than 15.2mm with new ones.
10.3 Recoat whole manifolds every 2 years.
10.4 In the movement and installation, pay attention to prevent all union trapezoidal
threads and sealing surface from damage, and prevent foreign matters entering pipes.
10.5 The maintenance of mud gate valve shall be carried out as per the instruction of
valve.
6
User Manual of Drilling Fluid Circulating Manifold
Attached list 2 Complimentary spare parts
Attached drawing 1 Installation diagram GH290.00 II
Attached drawing 2 Manifold GH290.01.00 I
7
User Manual of Drilling Fluid Circulating Manifold
Attached list 2 Complimentary spare parts
No. Description Spec. (drawing No.) Qty. Remarks
8
9