Procedure
1. Prepare the USB disk with a LED. The requirements are as follows: when there is no
read or write operation on the USB disk, the LED on the USB disk is ON; when there is
any read or write operation on the USB disk, the LED on the USB disk is blinking.
2. Check the compatibility of the USB disk with the NodeB. Do as follows to test the
USB disk: Insert the USB disk into the USB port on the WMPT of a NodeB that runs
normally, and wait for 3 seconds. If the LED on the USB disk blinked once, it indicates
that the USB disk is functional. If the USB disk fails the preceding test, change the USB
disk.
3. Save the related files in the USB disk according to the specified path.
(2) Upgrading the NodeB Software and Downloading the Data Configuration
File (on the NodeB Side).
Procedure
1. Plug the USB disk into the USB port on the WMPT of the BBU3900, as shown in
Figure 1.
2021-4-2 华为机密,未经许可不得扩散 第 1 页, 共 10 页
文档
文档名称 密级
Figure 1 Plugging the USB disk into the USB port on the WMPT
2. The NodeB automatically downloads the software and data configuration file,
activates the software, and then resets. For details on the status of the LED on the
USB disk and the status of the RUN LED on the WMPT in this process, see Table 1.
The NodeB downloads Blinking Blinking fast (ON for About 12 minutes
the software and data
0.125s and OFF for
configuration file from
the USB disk. 0.125s)
The NodeB runs ON Blinking slowly (ON You can infer that the
software of the
normally for 1s and OFF for
NodeB is upgraded
1s) successfully if this
state lasts more than
one minute.
2021-4-2 华为机密,未经许可不得扩散 第 2 页, 共 10 页
文档
文档名称 密级
Double-click setup.exe in the LMT installation directory to start installing the LMT.
Install the LMT by using the default settings.
The default installation path is D:\HW LMT.
----End
If... Then...
4. Choose Properties from the shortcut menu. The Local Area Connection
Properties dialog box is displayed.
2021-4-2 华为机密,未经许可不得扩散 第 3 页, 共 10 页
文档
文档名称 密级
Maintenance Terminal is started, choose System > Logout, or click . The User Login
Note: If you use LMT for the first time. Please click the to add the NodeB
2021-4-2 华为机密,未经许可不得扩散 第 4 页, 共 10 页
文档
文档名称 密级
2021-4-2 华为机密,未经许可不得扩散 第 5 页, 共 10 页
文档
文档名称 密级
Procedure
1. Ensure that the USB disk with a LED is available. Requirement: When there is no
read or write operation on the USB disk, the LED on the USB disk is on; when there is
read or write operation on the USB disk, the LED on the USB disk is blinking.
2. Check the compatibility of the USB disk with the BTS. Test method: Insert the USB
disk into the USB port on the GTMU of a GBTS that runs normally, and wait 3 seconds.
If the LED on the USB disk blinked once, the USB disk is functional. If the USB disk
fails the preceding test, change the USB disk.
a. Create a .txt file, and rename the file Precfg.ini. Edit the Precfg.ini file to
add the following contents into the Precfg.ini file.
b. [PRECONFIG]
ALL=GTMU|MRRU
c. Save the preconfiguration file in ANSI characters.
(2) Upgrading the NodeB Software and Downloading the Data Configuration
File (on the NodeB Side).
Procedure
1. Connect the USB disk to the GTMU through the USB port. Figure 1 shows the USB
port on the GTMU.
2021-4-2 华为机密,未经许可不得扩散 第 6 页, 共 10 页
文档
文档名称 密级
2. The GBTS automatically downloads the software and data configuration file, and
activates the software. After the activation, the GBTS resets. Wait until the GBTS reset
is complete. For details on the status of the LED on the USB disk and the status of the
RUN LED on the GTMU in this process, see Table 1.
Procedure
1. To set the IP address of the SMT client, perform the following steps. This section
takes the Windows XP operating system as an example. Choose Start > Setting >
Control Panel.
3. Choose Properties from the shortcut menu. The Local Area Connection Properties
dialog box is displayed.
2021-4-2 华为机密,未经许可不得扩散 第 7 页, 共 10 页
文档
文档名称 密级
4. Select Internet Protocol (TCP/IP), and click Properties. The Internet Protocol
(TCP/IP) Properties dialog box is displayed.
6. Enter the correct IP address, subnet mask, and default gateway. Ensure that the IP
address of the SMT client is on the same network segment as the IP address
(192.168.0.72/255.255.255.0) of the base station, so that a local OM channel can be
established.
Start the SMT. Choose Maintenance > Communication Parameter. In the Set
Communication Port Parameter dialog box, select Network Port under Select
Communication Port and set the IP address to 192.168.0.72. Then, click OK, as shown in the
figure.
2021-4-2 华为机密,未经许可不得扩散 第 8 页, 共 10 页
文档
文档名称 密级
Start the SMT. Click Board in the navigation tree, and then double-click Board Management
in the Function pane on the right, as shown in Figure 3-2.
The Board Management window is displayed.
2021-4-2 华为机密,未经许可不得扩散 第 9 页, 共 10 页
文档
文档名称 密级
2021-4-2 华为机密,未经许可不得扩散 第 10 页, 共 10 页