You are on page 1of 3

Inspection Report

DIRECT ASSESSMENT
JALUR PIPA YANG MENGALAMI
UNDERPROTEKSI KATODIK

Area : Bekasi Pipe Dia. : 4 in


Line : Jl. Pulo Gadung – I Gusti Ngurah Rai Pipe Sch. : 40
KP : 1695 Depth : 100 cm
Pipe Mat. : API 5L Grade B Tahun Konstruksi : 1986
Lokasi : Dekat Bak Telkom

THICKNESS MEASUREMENT
Remark
Point of Measurement 0o 90o 180o 270o Minimum
Thikness actual (mm) 3.23 3.24 3.25 3.25 3.23

SPOT POTENTIAL MEASUREMENT


(-mV vs CSE) Remarks
Pipe to soil
1148 Protected

SOIL RESISTIVITY
Soil Resistivity
Pin Distance (a) R 2∏a
(2 ∏ a R) Remarks
(cm) (ohm) (cm) (Ohm-cm)
100 3.41 628 2141 Moderatly Corrosive
200 1.73 1256 2173 Moderatly Corrosive

pH
Remarks
pH 6.5
Acidic

WATER LEVEL (cm)


Result Remarks
Water Level
+50 Legend: Bottom pipe / 180°

PT GIS INVISITAMA PT PGN Solution

Awab Nabawi ...........................................


NDT Level II Client's Rep.
Inspection Report
DIRECT ASSESSMENT
JALUR PIPA YANG MENGALAMI
UNDERPROTEKSI KATODIK

Area : Bekasi Pipe Dia. : 6 in


Line : Jl. Pulo Lentut - Rawa Sumur Pipe Sch. : 40
KP : 2660 Depth : 70 cm
Pipe Mat. : API 5L Grade B Tahun Konstruksi : 1988
Lokasi : pinggir jalan raya

THICKNESS MEASUREMENT
Remark
Point of Measurement 0o 90o 180o 270o Minimum
Thikness actual (mm) BV

SPOT POTENTIAL MEASUREMENT


(-mV vs CSE) Remarks
Pipe to soil

SOIL RESISTIVITY
Soil Resistivity
Pin Distance (a) R 2∏a
(2 ∏ a R) Remarks
(cm) (ohm) (cm) (Ohm-cm)
100 1.89 628 1187 Corrosive
200 0.44 1256 553 Very Corrosive

pH
Remarks
pH 6.1
Acidic

WATER LEVEL (cm)


Result Remarks
Water Level
+70 Legend: Bottom pipe / 180°

PT GIS INVISITAMA PT PGN Solution

Awab Nabawi ...........................................


NDT Level II Client's Rep.
Pull Off Test Report
PROJECT PEMASANGAN SPM KAPASITAS 50.000 DWT
BERIKUT JALUR PIPA KE TBBM PENGAMPON

Owner : PT Pertamina (Persero)


Contractor : PT Wijaya Karya (Tbk)
Lokasi : Cilacap & Semarang
Lokasi Test : Jakarta
Date of install dollies : March 4, 2021
Date of pull off test : March 4, 2021
Painting System : 2 Layer (Primary & Top Coat)
Pull tester type : Elcometer
Adhesive type : Cyanoacrylate Fast Dry Glue – Krisbow Dolly size: 10 mm
Pull test standard : ASTM D4541 – Minimum Pull Off Test Value: 3 Mpa

Test No. / DFT Value Description


Result Remark
Dollies No. (µm) (Mpa) (Nature of Failure)
290
40% Cohesion Primary coat
#1 306 8.0 60% Glue Failure ACC
282

299
40% Cohesion Primary coat
#2 300 9.0 60% Glue Failure ACC
302

293
60% Cohesion Primary coat
#3 297 10.0 40% Glue Failure ACC
303

175
60% Cohesion Primary coat
#4 180 5.0 40% Glue Failure ACC
160

PT GIS INVISITAMA PT WIJAYA KARYA (Persero), Tbk

Yusronnul Arifien
(NACE CIP 1) Reviewer