Department Name : Quality Department / QC Code No.: MOA 014/1
1. Revision:
First Issue
2. Introduction:
These test method cover the determination of the various stages and rates of film formation
in the drying or curing of organic normally used under conditions of ambient room
temperature.
3. Panel Preparation :
3.1 Clean and dry glass panel well by suitable solvent >
3.2 Clean and dry the used applicator .
3.3 Put the applicator on the glass panel in horizontal position using 3 mils site>
3.4 Fill the gap of the applicator by paint material to be tested.
3.5 Draw down the paint film.
3.6 Keep the paint film to dry at room temperature in suitable open box.
3.7 Observe the drying along tome y touch the paint film and record the time when complete
drying.
Method Of Analysis
Page 4 of 4
Department Name : Quality Department / QC Code No.: MOA 014/1
A film is considered dry for recoating when second coat can be applied without the
development of any film irregularities
10 .Result :
Pass or Fail
11 .References: