You are on page 1of 32

© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Overview ■ Configuration
Installation

4
Keep unit out of path of falling material, or protect probe from
Pointek CLS200 (standard version) is a versatile inverse fre- falling material.
quency shift capacitance level and material detection switch
with optional rod/cable choices and configurable output.
CLS200 is ideal for detection of liquids, solids, slurries, foam,
and interfaces and has the ability to tune out buildup on the
probe.

■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity, and/or condensation
• High chemical resistance
Avoid areas where material build up occurs.
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency
oscillation
• 3 LED indicators for sensor status, output status, and power
• Suitable for API 2350

■ Application
Pointek CLS200 standard version has 3 LED indicators with
basic relay and solid-state switch alarms. Universal switch for
M
solids/liquids and interface. in
.5
0
The power supply is galvanically isolated and accepts a wide (2
)
range of voltages (12 to 250 V AC/DC). When used with thermal
isolator, the stainless steel and PPS (PVDF optional) materials
used in the probe construction provide a temperature rating up
to 125 °C (257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency, and
it can be set to detect before contact or on contact with the Install probe at least 50 (2) from tank wall.
probe. The CLS200 operates independently of the tank wall or
pipe so it does not require an external reference electrode for Pointek CLS200 installation, dimensions in mm (inch)
level detection in a non-conductive vessel such as concrete or
plastic (EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas

Siemens FI 01 · 2021 4/17


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Technical specifications
Mode of operation Design
Measuring principle Inverse frequency shift capacitive Material
level detection • Enclosure Epoxy-coated aluminum with gasket
Input • Optional thermal isolator 316L stainless steel
Measured variable Change in picoFarad (pF) Connection Removable terminal block,
max. 2.5mm²
Output
Degree of protection IP65/Type 4/NEMA 4 (optional IP68)
Output signal
• Relay output 1 SPDT Form C relay Cable inlet 2 x M20 x 1.5 thread
(option: 2 x ½" NPT conduit entry
- Max. contact voltage • 30 V DC including 1 plugged entry)
• 250 V AC
- Max. contact current • 5 A DC Power supply 12 ... 250 V AC/DC,
• 8 A AC 0 ... 60 Hz max. 2 W
- Max. switching capacity 150 W DC Certificates and approvals
2 000 VA AC General Purpose CSA, FM, CE, RCM
- Time delay (ON and/or OFF) 1 ... 60 s

4 • Solid-state output
- Output Galvanically isolated
Dust Ignition Proof
Flameproof Enclosure With IS Probe
ATEX II ½ D T100 °C
ATEX II 1 G EEx d[ia] IIC T6 ... T4
- Protection Against reversed polarity (bipolar) ATEX II ½ D T100 °C
- Max. switching voltage • 30 V DC Dust Ignition Proof with IS Probe CSA/FM Class II, Div. 1,
• 30 V peak AC Groups E, F, G
- Max. load current 82 mA CSA/FM Class III T4
- Voltage drop < 1 V, typical at 50 mA Explosion Proof Enclosure CSA/FM Class I, Div. 1,
- Time delay (pre or post switching) 1 ... 60 s With IS Probe Groups A, B, C, D
CSA/FM Class II, Div. 1,
Rated operating conditions1)
Groups E, F, G
Installation conditions CSA/FM Class III T4
• Location Indoor/outdoor Marine Lloyds Register of Shipping,
Ambient conditions Categories ENV1, ENV2, and ENV5
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) Overfill Protection WHG (Germany)
• Storage temperature -40 ... +85 °C (-40 ... +185 °F) VLAREM II
• Installation category II Others Pattern Approval (China), SIL
• Pollution degree 4
1)
When operation is in areas classified as hazardous, observe restrictions
Medium conditions Liquids, bulk solids, slurries and according to relevant certificate. See also Pressure/Temperature curves on
interfaces page 5/34.
• Relative dielectric constant εr Min. 1.5 2)
Thermal isolator is used if process connection temperature exceeds 85 °C
• Process temperature (185 °F)
2)
- Without thermal isolator -40 ... +85 °C (-40 ... +185 °F) 3)
Pressure rating of process seal is temperature dependent.
- With thermal isolator -40 ... +125 °C (-40 ... +257 °F) See Pressure/Temperature curves on page 5/34.
• Process pressure (rod version) -1 ... +25 bar g (-14.6 ... +365 psi g)
(nominal)
• Process pressure (cable version)3) -1 ... +10 bar g (-14.6 ... +150 psi g)
(nominal)
• Process pressure (sliding coupling -1 ... +10 bar g (-14.6 ... +150 psi g)
version) (nominal)
Electromagnetic compatibility To comply with CE EMC regulations
(where applicable); the CLS200
should be installed per the instruction
manual.

4/18 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Technical specifications (continued)


Design: Probe
Rod version Sanitary version Cable version Sliding Coupling version
Max. length 5 500 mm (216.53 inch) 5 500 mm (216.53 inch) • 30 000 mm (1 181.1 inch) 5 500 mm (216.53 inch)
liquids and slurries
• 5 000 mm (196.85 inch)
solids (under loads)
Process connection R ¾", 1", 1¼", 1½" 1½", 2" sanitary fitting clamp R ¾", 1", 1¼", 1½" R ¾", 1", 1¼", 1½"
[(BSPT), EN 10226/PT 316L stainless steel [(BSPT), EN 10226/PT (JIS-T), [(BSPT), EN 10226/PT (JIS-T),
(JIS-T), JIS B 0203] JIS B 0203] JIS B 0203]

¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" G ¾", 1", 1½" G ¾", 1", 1½"
[(BSPP), EN ISO 228-1/PF [(BSPP), EN ISO 228-1/PF [(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202] (JIS-P), JIS B 0202] (JIS-P), JIS B 0202]
316L stainless 316L stainless steel

4
steelASME/EN flange ASME/EN flange
Extension material 316L stainless steel 316L stainless steel Fluoroethylene propylene (FEP) 316L stainless steel
optional PFA coated1) cable with stainless steel core
Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF)
O-ring seal material FKM (optional FFKM)2) FKM (optional FFKM)2) FKM (optional FFKM)2) FKM (optional FFKM)2)
Thermal isolator3) Optional Optional Optional Optional
Extension User selected length User selected length Cable extension User selected length
1) PFA coating (7ML5634 and 7ML5644) has 120 micron thickness
2) For caustic materials, consult a local sales person for alternative O-rings. For more information, please visit http://www.automation.siemens.com/aspa_app.
3) Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F)

Siemens FI 01 · 2021 4/19


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5630- Pointek CLS200 RF Capacitance point level 7ML5630-
switch, rod design switch, rod design
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, slurries, Detects level and interface in liquids, solids, slurries,
and foam. Adjustable, 5.5 m (18.04 ft), insertion, and foam. Adjustable, 5.5 m (18.04 ft), insertion,
adaptable sensitivity, with the ability to tune out adaptable sensitivity, with the ability to tune out
build-up on probe. build-up on probe.
Click on the Article No. for the online Add Order code Y01 and plain text:
configuration in the PIA Life Cycle Portal. "Insertion length ... mm"
Extended rod, 210 ... 1 000 mm (8.27 ... 39.37 inch) M
Process connection
Extended rod, 1 001 ... 2 000 mm N
Threaded, 316L stainless steel (39.41 ... 78.74 inch)
¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A Extended rod, 2 001 ... 3 000 mm P
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B (78.78 ... 118.11 inch)
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C Extended rod, 3 001 ... 4 000 mm Q
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D (118.15 ... 157.48 inch)
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A Extended rod, 4 001 ... 5 000 mm R
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B (157.52 ... 196.85 inch)

4 R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D Extended rod, 5 001 ... 5 500 mm S
G ¾" [(BSPP), EN SO 228-1/PF (JIS-P), JIS B 0202] 3 A (196.89 ... 216.53 inch)
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B Thermal isolator
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D Without thermal isolator 0
JIS B 0202] With thermal isolator [for process connection 1
Welded flange, 316L stainless steel, raised face temperatures over 85 °C (185 °F)]
1" ASME, 150 lb 5 A Remote mount electronics and mounting bracket
1" ASME, 300 lb 5 B With 2 m (79 inch) of cable1)2) 2
1" ASME, 600 lb 5 C With 5 m (197 inch) of cable1)2) 3
1½" ASME, 150 lb 5 D Wetted seals
1½" ASME, 300 lb 5 E FKM 0
1½" ASME, 600 lb 5 F FFKM [for process temperatures above 1
2" ASME, 150 lb 5 G -20 °C (-4 °F)]
2" ASME, 300 lb 5 H
Probe material
2" ASME, 600 lb 5 J
316L stainless steel with PPS probe body 0
3" ASME, 150 lb 5 K
316L stainless steel with PVDF probe body 1
3" ASME, 300 lb 5 L
3" ASME, 600 lb 5 M Approvals
4" ASME, 150 lb 5 N Dust Ignition Proof:CE, RCM, ATEX II 1/2 D T100 °C C
4" ASME, 300 lb 5 P Flameproof Enclosure with IS Probe: D
4" ASME, 600 lb 5 Q CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Welded flange, 316L stainless steel, Type A Flameproof Enclosure with IS Probe, E
flat faced with WHG approval:
DN 25, PN 16 6 A CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
DN 25, PN 40 6 B ATEX II 1/2 D T100 °C
DN 40, PN 16 6 C Dust Ignition Proof with IS Probe: F
DN 40, PN 40 6 D CSA/FM Class II, Div. 1, Groups E, F, G,
CSA/FM Class III T4
DN 50, PN 16 6 E
DN 50, PN 40 6 F Explosion Proof Enclosure with G
IS Probe:CSA/FM Class I, Div. 1, Groups A, B, C, D,
DN 80, PN 16 6 G CSA/FM Class II, Div. 1, Groups E, F, G,
DN 80, PN 40 6 H CSA/FM Class III T4
DN 100, PN 16 6 J General Purpose (CSA, FM) H
DN 100, PN 40 6 K General Purpose (CE, RCM) J
(Note: Flange bolting patterns and facings General Purpose (CSA, FM, CE, RCM) K
dimensionally correspond to the applicable with WHG approval
ASME B16.5 or EN 1092-1 standard.)
Enclosure and lid
Probe length
Aluminum epoxy coated
(length from flange face) 2 x ½" NPT via adapter - cable inlet, IP65 A
(threaded lengths include process thread)
2 x M20 x 1.5 cable inlet, IP65 B
Note: No Y01 needed in Order code for 2 x ½" NPT via adapter - cable inlet, IP68 C
standard lengths 2 x M20 x 1.5 cable inlet IP68 D
Compact [threaded 120 mm (4.72 inch), A
Flanged 98 mm (3.86 inch)] 1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
Extended rod, 250 mm (9.84 inch) B protection.
Extended rod, 350 mm (13.78 inch) C 2)
Available with Approval options F, G, and H.
Extended rod, 500 mm (19.69 inch) D
Extended rod, 750 mm (29.53 inch) E
Extended rod, 1 000 mm (39.37 inch) F
Extended rod, 1 250 mm (49.21 inch) G
Extended rod, 1 350 mm (53.15 inch) H
Extended rod, 1 500 mm (59.06 inch) J
Extended rod, 1 750 mm (68.90 inch) K
Extended rod, 2 000 mm (78.74 inch) L

4/20 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Selection and ordering data Order code Article No.

Further designs Pointek CLS200 RF Capacitance point level 7ML5631-


switch, cable design
Please add "-Z" to Article No. 77777 - 7770
and specify Order code(s). Detects level and interface in liquids, solids, slurries,
and foam. Cable extension options to 30 m (98.43 ft),
Total insertion length: enter the total insertion length Y01 adaptable sensitivity, with the ability to tune out
in plain text description build-up on probe.
Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15 Click on the Article No. for the online
Measuring-point number/identification configuration in the PIA Life Cycle Portal.
(max. 27 characters) specify in plain text
Process connection
Manufacturer's test certificate: M to DIN 55350, C11
Part 18 and ISO 9000 Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A
Material inspection Certificate Type 3.1 per C12 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B
EN 10204
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C
SIL/IEC 61508 Declaration of Conformity C20 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D
[SIL 2 (overspill)] R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A
INMETRO1) E34 R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B
Operating Instructions
All literature is available to download for free,
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
1
3
D
A 4
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B
in a range of languages, at G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D
http://www.siemens.com/processinstrumentation/documentation JIS B 0202]

Accessories See page 4/41 Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb 5 A
1) Available only with Approvals options C, D, E. 1" ASME, 300 lb 5 B
1" ASME, 600 lb 5 C
1½" ASME, 150 lb 5 D
1½" ASME, 300 lb 5 E
1½" ASME, 600 lb 5 F
2" ASME, 150 lb 5 G
2" ASME, 300 lb 5 H
2" ASME, 600 lb 5 J
3" ASME, 150 lb 5 K
3" ASME, 300 lb 5 L
3" ASME, 600 lb 5 M
4" ASME, 150 lb 5 N
4" ASME, 300 lb 5 P
4" ASME, 600 lb 5 Q
Welded flange, 316L stainless steel, Type A
flat faced
DN 25, PN 16 6 A
DN 25, PN 40 6 B
DN 40, PN 16 6 C
DN 40, PN 40 6 D
DN 50, PN 16 6 E
DN 50, PN 40 6 F
DN 80, PN 16 6 G
DN 80, PN 40 6 H
DN 100, PN 16 6 J
DN 100, PN 40 6 K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)

Siemens FI 01 · 2021 4/21


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Selection and ordering data Article No. Order code

Pointek CLS200 RF Capacitance point level 7ML5631- Further designs


switch, cable design
77777 - 7770 Please add "-Z" to Article No.
Detects level and interface in liquids, solids, slurries, and specify Order code(s).
and foam. Cable extension options to 30 m (98.43 ft),
adaptable sensitivity, with the ability to tune out Total insertion length: enter the total insertion length Y01
build-up on probe. in plain text description
Probe length Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15
Measuring-point number/identification
(length from flange face)
(max. 27 characters) specify in plain text
(threaded lengths include process thread)
Note: No Y01 needed in Order code for Manufacturer's test certificate: M to DIN 55350, C11
standard lengths Part 18 and ISO 9000
Extended cable, 3 000 mm (118.11 inch), length A Material inspection Certificate Type 3.1 per C12
can be determined by customer on assembly1) EN 10204
Extended cable, 6 000 mm (236.22 inch), length B
can be determined by customer on assembly1) SIL/IEC 61508 Declaration of Conformity C20
[SIL 2 (overspill)]
Add Order code Y01 and plain text:
"Insertion length ... mm" INMETRO1) E34

4 Extended cable, 500 ... 5 000 mm


(19.69 ... 196.85 inch)
C
Operating Instructions
All literature is available to download for free, in a
Extended cable, 5 001 ... 10 00 mm D
(196.89 ... 393.70 inch) range of languages, at
Extended cable, 10 001 ... 15 000 mm E http://www.siemens.com/processinstrumentation/documentation
(393.74 ... 590.55 inch)
Extended cable, 15 001 ... 20 000 mm F Accessories See page 4/41
(590.59 ... 787.4 inch) 1)
Extended cable, 20 001 ... 25 000 mm G Available only with Approvals options C, D, E.
(787.44 ... 984.25 inch)
Extended cable, 25 001 ... 30 000 mm H
(984.29 ... 1 181.1 inch)
Thermal isolator
Without thermal isolator 0
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]
Remote mount electronics and mounting bracket
With 2 m (79 inch) of cable2) 2
With 5 m (197 inch) of cable2) 3
Wetted seals
FKM and PTFE 0
FFKM and PTFE [for process temperatures above 1
-20 °C ) (-4 °F)]
Probe material
FEP jacketed cable with PPS probe body 0
FEP jacketed cable with PVDF probe body 1
Approvals
Dust Ignition Proof: C
CE, RCM, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe: D
CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, E
with WHG approval:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe: F
CSA/FM Class II, Div. 1, Groups E, F, G,
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe: G
CSA/FM Class I, Div. 1, Groups A, B, C, D,
CSA/FM Class II, Div. 1, Groups E, F, G,
CSA/FM Class III T4
General Purpose (CSA, FM) H
General Purpose (CE, RCM) J
General Purpose (CSA, FM, CE, RCM) with K
WHG approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65 A
2 x M20 x 1.5 cable inlet, IP65 B
2 x ½" NPT via adapter - cable inlet, IP68 C
2 x M20 x 1.5 cable inlet, IP68 D
1)
Sensor detached to allow customer to set desired cable length.
2)
Available with Approvals options F ... H.

4/22 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5632- Pointek CLS200 RF Capacitance point level 7ML5632-
switch, sanitary rod design switch, sanitary rod design
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, Detects level and interface in liquids, solids,
slurries, and foam. Adjustable, 5.5 m (18.04 ft), slurries, and foam. Adjustable, 5.5 m (18.04 ft),
insertion, adaptable sensitivity, with the ability to insertion, adaptable sensitivity, with the ability to
tune out build-up on probe. tune out build-up on probe.
Click on the Article No. for the online Approvals
configuration in the PIA Life Cycle Portal. Dust Ignition Proof: C
CE, RCM, ATEX II ½ D T100 °C
Process connection
Flameproof Enclosure with IS Probe: D
Sanitary 316L stainless steel CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
1" sanitary fitting clamp 8 A ATEX II ½ D T100 °C
1½" sanitary fitting clamp 8 B Flameproof Enclosure with IS Probe: E
2" sanitary fitting clamp 8 C CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
2½" sanitary fitting clamp 8 D ATEX II ½ D T100 °C
3" sanitary fitting clamp 8 E Flameproof Enclosure with IS Probe, F
(Note: Sanitary connection dimensionally with WHG approval:
CE, RCM, ATEX II ½ G EEx d[ia] IIC T6 ... T4,
4
corresponds to the applicable ISO 2852 standard)
ATEX II ½ D T100 °C
Probe length Dust Ignition Proof with IS Probe: G
(length from process connection face) CSA/FM Class II, Div. 1, Groups E, F, G,
CSA/FM Class III T4
Note: No Y01 needed in Order code for
standard lengths General Purpose (CSA, FM) H
Compact, 98 mm (3.86 inch) A General Purpose (CE, RCM) J
Extended rod, 250 mm (9.84 inch) B General Purpose (CSA, FM, CE, RCM) K
with WHG approval
Extended rod, 350 mm (13.78 inch) C
Extended rod, 500 mm (19.69 inch) D Enclosure and lid
Extended rod, 750 mm (29.53 inch) E Aluminum epoxy coated
Extended rod, 1 000 mm (39.37 inch) F 2 x ½" NPT via adapter - cable inlet, IP65 A
Extended rod, 1 250 mm (49.21 inch) G 2 x M20 x 1.5 cable inlet, IP65 B
Extended rod, 1 350 mm (53.15 inch) H 2 x ½" NPT via adapter - cable inlet, IP68 C
Extended rod, 1 500 mm (59.06 inch) J 2 x M20 x 1.5 cable inlet, IP68 D
Extended rod, 1 750 mm (68.90 inch) K
Extended rod, 2 000 mm (78.74 inch) L
Add Order code Y01 and plain text: Further designs Order code
"Insertion length ... mm"
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch) M Please add "-Z" to Article No.
Extended rod, 351 ... 1 000 mm N and specify Order code(s).
(13.78 ... 39.37 inch) Total insertion length: enter the total insertion length Y01
Extended rod, 1 001 ... 2 000 mm P in plain text description
(39.41 ... 78.74 inch)
Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15
Extended rod, 2 001 ... 3 000 mm Q Measuring-point number/identification
(78.78 ... 118.11 inch) (max. 27 characters) specify in plain text
Extended rod, 3 001 ... 4 000 mm R
(118.15 ... 157.48 inch) Manufacturer's test certificate: M to DIN 55350, C11
Extended rod, 4 001 ... 5 000 mm S Part 18 and ISO 9000
(157.52 ... 196.85 inch) Material inspection Certificate Type 3.1 per C12
Extended rod, 5 001 ... 5 500 mm T EN 10204
(196.89 ... 216.53 inch)
SIL/IEC 61508 Declaration of Conformity C20
Thermal isolator [SIL 2 (overspill)]
Thermal isolator 0
INMETRO1) E34
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)] Operating Instructions
Remote mount electronics and mounting bracket All literature is available to download for free, in a
Remote mount electronics and mounting bracket 2 range of languages, at
Remote mount electronics with 5 m (197 inch) 3 http://www.siemens.com/processinstrumentation/documentation
of cable
Accessories See page 4/41
Wetted seals
1) Available only with Approvals options C, D, E.
FKM 0
FFKM 1
[for process temperatures above -20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body 0
316L stainless steel with PVDF probe body 1

Siemens FI 01 · 2021 4/23


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5633- Pointek CLS200 RF Capacitance point level 7ML5633-
switch, sliding coupling design switch, sliding coupling design
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, slurries, Detects level and interface in liquids, solids, slurries,
and foam. Adjustable, 5.5 m (18.04 ft), insertion, and foam. Adjustable, 5.5 m (18.04 ft), insertion,
adaptable sensitivity, with the ability to tune out adaptable sensitivity, with the ability to tune out
build-up on probe. build-up on probe.
Click on the Article No. for the online Approvals
configuration in the PIA Life Cycle Portal. Dust Ignition Proof: C
CE, RCM, ATEX II 1/2 D T100 °C
Process connection
Flameproof Enclosure with IS Probe: D
Threaded, 316L stainless steel CE, RCM, ATEX II 1 G EEx d[ia] IIC T6 ... T4,
¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A ATEX II 1/2 D T100 °C
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B Flameproof Enclosure with IS Probe, E
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C with WHG approval:
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A
Dust Ignition Proof with IS Probe: F
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B

4
CSA/FM Class II, Div. 1, Groups E, F, G
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D CSA/FM Class III T4
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A Explosion Proof Enclosure with IS Probe: G
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B CSA/FM Class I, Div. 1, Groups A, B, C, D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D CSA/FM Class II, Div. 1, Groups E, F, G
JIS B 0202] CSA/FM Class III T4
General Purpose (CSA, FM) H
Probe length
General Purpose (CE, RCM) J
(length from flange face) General Purpose (CSA, FM, CE, RCM) K
(threaded lengths include process thread) with WHG approval
Note: No Y01 needed in Order code for
standard lengths Enclosure and lid
Extended rod, 350 mm (13.78 inch) C Aluminum epoxy coated
Extended rod, 500 mm (19.69 inch) D 2 x ½" NPT via adapter - cable inlet, IP65 A
Extended rod, 750 mm (29.53 inch) E 2 x M20 x 1.5 cable inlet, IP65 B
Extended rod, 1 000 mm (39.37 inch) F 2 x ½" NPT via adapter - cable inlet, IP68 C
Extended rod, 1 250 mm (49.21 inch) G 2 x M20 x 1.5 cable inlet, IP68 D
Extended rod, 1 350 mm (53.15 inch) H 1) Available with Approvals options F ... H.
Extended rod, 1 500 mm (59.06 inch) J
Extended rod, 1 750 mm (68.90 inch) K
Extended rod, 2 000 mm (78.74 inch) L Further designs Order code
Add Order code Y01 and plain text: Please add "-Z" to Article No.
"Insertion length ... mm" and specify Order code(s).
Extended rod, 350 ... 1 000 mm M
(13.78 ... 39.37 inch) Total insertion length: enter the total insertion length Y01
Extended rod, 1 001 ... 2 000 mm N in plain text description
(39.41 ... 78.74 inch) Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15
Extended rod, 2 001 ... 3 000 mm P Measuring-point number/identification
(78.78 ... 118.11 inch) (max. 27 characters) specify in plain text
Extended rod, 3 001 ... 4 000 mm Q Manufacturer's test certificate: M to DIN 55350, C11
(118.15 ... 157.48 inch) Part 18 and ISO 9000
Extended rod, 4 001 ... 5 000 mm R
(157.52 ... 196.85 inch) Material inspection Certificate Type 3.1 per C12
Extended rod, 5 001 ... 5 500 mm S EN 10204
(196.89 ... 216.53 inch) SIL/IEC 61508 Declaration of Conformity C20
Thermal isolator [SIL 2 (overspill)]
Without thermal isolator 0 INMETRO1) E34
With thermal isolator [for process connection 1 Operating Instructions
temperatures over 85 °C (185 °F)]
All literature is available to download for free, in a
Remote mount electronics and mounting bracket range of languages, at
With 2 m (79 inch) of cable1) 2
With 5 m (197 inch) of cable1) 3 http://www.siemens.com/processinstrumentation/documentation

Wetted seals Accessories See page 4/41


FKM and PTFE 0 1)
Available only with Approval options C, D, E.
FFKM and PTFE [for process temperatures above 1
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body 0
316L stainless steel with PVDF probe body 1

4/24 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Options
Optional SensGuard
Internal thread ¾" NPT
(1.26)

(1.26)
32

32
Process
Process connection
connection R 1" (BSPT)
¾" NPT
91 (3.6)

91 (3.6)
70 (2.75)

70 (2.75)

Optional SensGuard, dimensions in mm (inch) 4


■ Characteristic curves
Pressure/temperature curve
CLS200 sliding coupling
threaded process connections
(7ML5633 and 7ML5643)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C

Pointek CLS200 process pressure/temperature derating curves (7ML5633 and 7ML5643)

Siemens FI 01 · 2021 4/25


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Characteristic curves (continued)


Pressure/temperature curve
CLS200 cable
Threaded process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
4 -40 ºF 14 ºF
(-40 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 process pressure/temperature derating curves (7ML5631 and 7ML5641)

Pressure/temperature curve
CLS200 compact and extended rod
Threaded process connections
(7ML5630 and 7ML5640)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

Atmospheric 10 bar (145 psi)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 process pressure/temperature derating curves (7ML5630 or 7ML5640)

4/26 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Characteristic curves (continued)


Pressure/temperature curve
CLS200 compact and extended sanitary type
Sanitary process connections
(7ML5632 and 7ML5642)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC) 4
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 process pressure/temperature derating curves (7ML5632 and 7ML5642)

Pressure/temperature curve
CLS200, cable
ASME flanged process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5631 and 7ML5641)

Siemens FI 01 · 2021 4/27


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Characteristic curves (continued)


Pressure/temperature curve
CLS200 compact and extended rod
ASME flanged process connections
(7ML5630 and 7ML5640)

Permitted operating pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)
4
20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5630 and 7ML5640)

Pressure/temperature curve
CLS200 cable
EN flanged process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


PN 161)
Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5631 and 7ML5641)

4/28 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Characteristic curves (continued)


Pressure/Temperature Curve
CLS200 Compact and Extended Rod
EN Flanged Process Connections
(7ML5630 and 7ML5640)

Permitted Operating Pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

PN 401) 4
20 bar (290 psi)

Atmospheric 10 bar (145 psi) PN 161)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted Operating Temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5630 and 7ML5640)

Siemens FI 01 · 2021 4/29


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Dimensional drawings

Compact version Extended rod version Extended cable version


Threaded Threaded Threaded
(7ML5630 and 7ML5640) (7ML5630 and 7ML5640) (7ML5631 and 7ML5641)

Electronics/
enclosure

Y01 (insertion length)


(4.7)
120

22
(0.87)

PPS or optional 316L stainless


PVDF probe steel extension

Y01 (insertion length)


Ø20 (0.79) FEP insulated

4 cable Ø6 (0.3)

(3.3)
84
PPS or optional
Sanitary compact version
PVDF probe
Sanitary fitting 316L stainless steel
(7ML5632 and 7ML5642) sensor weight
Min. insertion length = 200 (7.87)
Max. insertion length = 5 500 (216)
Ø20 (0.79)

(3.3)
84
316L stainless steel PPS or optional
sanitary process PVDF probe
connection
Min. insertion length = 500 (19.69)
(3.8)
98

Max. insertion length = 30 000 (1 181)


PPS or optional
Applicable for liquids and solids
PVDF probe
applications. Cable can be shortened
on site.

2 cable entries Sanitary extended version Sliding coupling version


½" NPT or Sanitary fitting Threaded
M20 x 1.5 (7ML5632 and 7ML5642) (7ML5633 and 7ML5643)

M20: 135 (5.32)


½" NPT: 150 (5.91)

Lid with window 316L stainless steel


sanitary process
connection
Y01 (insertion length)

316L stainless
GP, DIP lid,
without window 316L stainless steel sliding
steel extension coupling
Y01 (insertion length)
139 (5.47)

Ø24 (0.95)
XP, lid without window
132 (5.20)

(3.8)
226 (8.90)

98

PPS or optional
219 (8.62)

PVDF probe
(4.96)

Min. 215
126

(8.46)
213 (8.39)

Min. insertion length = 110 (4.3) Ø20 (0.79)


Max. insertion length = 5 500 (216)
Thermal
(3.3)
84

isolator PPS or optional


PVDF probe

Min. insertion length = 350 (13.82)


Max. insertion length = 5 500 (216)

Pointek CLS200 threaded/sanitary process connection, dimensions in mm (inch)

4/30 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Dimensional drawings (continued)


Compact version Extended rod version Extended cable version
Welded Flange (7ML5630 and 7ML5640) Welded Flange (7ML5630 and 7ML5640) Welded Flange
Welded Flange, PFA coated Welded Flange, PFA coated (7ML5631 and 7ML5641)
(7ML5634 and 7ML5644) (7ML5634 and 7ML5644)

Electronics/
enclosure

Y01 (insertion length)


(3.8)

316L stainless
98

PPS or optional steel extension


PVDF probe (or PFA coated

Y01 (insertion length)


Ø20 (0.79) FEP insulated
2 cable entries
½" NPT or cable Ø6 (0.3)
4
(3.3)
84
M20 x 1.5 PPS or optional
PVDF probe
M20: 135 (5.32) 316L stainless steel
½" NPT: 150 (5.91) sensor weight
Min. insertion length = 200 (7.87)
Lid with window Max. insertion length = 5 500 (216)
Ø20 (0.79)

(3.3)
84
GP, DIP lid, PPS or optional
without window PVDF probe

Min. insertion length = 500 (19.69)


Max. insertion length = 30 000 (1 181)
Applicable for liquids and solids applica-
161 (6.34)

XP, lid without window tions. Cable can be shortened on site.


154 (6.06)

249 (9.80)
242 (9.53)
(5.83)

Flange Facing (raised face)


148

236 (9.29)

Flange Class Facing thickness


Thermal ASME 150/300 2 (0.08)
isolator
ASME 600/900 7 (0.28)
PN16/40 2 (0.08)

Insertion length does not include any raised face/gasket face dimension
(see Flange Facing Table above)

Pointek CLS200 flanged process connections, dimensions in mm (inch)

Siemens FI 01 · 2021 4/31


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Standard

■ Circuit diagrams

Wiring: Pointek CLS200 standard


White
Black
Red P2
Trip
point
(+)

(f )

Switch bank
P1 S1 K1
OFF
GND

- + 3 2 1 K4
Delay Sensor
L1 L3
Sensor Power 1 2 3
L2 status on
Output Power

4
status supply
12 to 250 V AC/DC

NC NO NO
K2 K3
Solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
Relay contact:
8 A at 250 V AC, 2 000 VA
5 A at 30 V DC, 150 W
Notes:
- Identification label is on underside of lid. Switch and potentiometer settings
are for illustration purposes only (refer to operation/setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction Manual or contact Siemens representative for detailed
wiring information.

Wiring: Pointek CLS200 Digital

White
Reed
Test input contact*
White

Red (+)

Sensor Black (-)


Alarm output
solid-state switch Orange (f)

24 V DC/PROFIBUS PA

Power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the instruction manual or contact a Siemens representative
for detailed wiring information.

*Magnet activated sensor Test


A magnet can be used to test the sensor without opening the lid of the
Pointek CLS200 Digital version. Bring the magnet close to the test
area indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.

Pointek CLS200 connections

4/32 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Overview ■ Configuration
Installation

4
Keep unit out of path of falling material, or protect probe from
Pointek CLS200 (digital version) is a versatile inverse frequency falling material.
shift capacitance level and material detection switch with
optional rod/cable choices and configurable output. CLS200 is
ideal for detection of liquids, solids, slurries, foam, and inter-
faces and has the ability to tune out buildup on the probe.
The digital version includes PROFIBUS PA, an LCD display, and
advanced diagnostic features.

■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity, and/or condensation
• High chemical resistance Avoid areas where material build up occurs.

• Level detection independent of tank or pipe earth reference


• Insensitive to product buildup due to high frequency
oscillation
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)

■ Application M
in
.5
Pointek CLS200 digital version provides an integral LCD display 0
(2
for stand-alone use, and also provides PROFIBUS PA communi- )
cation (Profile version 3.0, Class B) for connection to a network.
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 30 V DC). When used with thermal
isolator, the stainless steel and PPS (PVDF optional) materials
used in the probe construction provide a temperature rating up Install probe at least 50 (2) from tank wall.
to 125 °C (257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency, and Pointek CLS200 installation, dimensions in mm (inch)
it can be set to detect before contact or on contact with the
probe. The menu-driven setup allows precise control of the
switch point signal damping and alarm functions.
When connected to the PROFIBUS network, advanced diagnos-
tics and set up using SIMATIC PDM are possible.
The CLS200 operates independently of the tank wall or pipe so
it does not require an external reference electrode for level
detection in a non-conductive vessel such as concrete or plastic
(EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas

Siemens FI 01 · 2021 4/33


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Technical specifications
Mode of operation Power supply
Measuring principle Inverse frequency shift capacitive Bus voltage Standard: 12 ... 30 V DC
level detection Intrinsically Safe: 12 ... 24 V DC
Input Current consumption 12.5 mA
Measured variable Change in picoFarad (pF) Certificates and approvals
Output General Purpose CSA, FM, CE, RCM
Output signal Dust Ignition Proof ATEX II 1/2 D T100 °C
• Solid-state output
Dust Ignition Proof with IS Probe CSA/FM Class II, Div. 1,
- Output Galvanically isolated Groups E, F, G
- Protection Against reversed polarity (bipolar) CSA/FM Class III T4
- Max. switching voltage • 30 V (DC) Flameproof Enclosure with IS Probe ATEX II 1/2 G EEx d[ia] IIC T6 ... T4
• 30 V peak (AC) ATEX II ½ D T100 °C
- Max. load current 82 mA
Explosion Proof with IS Probe CSA/FM Class I, Div. 1,
- Voltage drop < 1 V, typical at 50 mA
Groups A, B, C, D

4
- Time delay (ON and/or OFF) Programmable by user (0 ... 100 s) CSA/FM Class II, Div. 1,
• Fail-safe mode Min. or max. Groups E, F, G
• Connection Removable terminal block CSA/FM Class III T4
Rated operating conditions1) Intrinsically Safe4) ATEX II 1 G EEx ia IIC T6 ... T4
ATEX II ½ D IP6X T100 °C
Installation conditions CSA/FM Class I, Div. 1,
• Location Indoor/outdoor Groups A, B, C, D
CSA/FM Class II, Div. 1,
Ambient conditions Groups E, F, G
• Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) CSA/FM Class III T4
• Storage temperature -40 ... +85 °C (-40 ... +185 °F)
Non-incendive CSA/FM Class I, Div. 2,
• Installation category II Groups A, B, C, D
• Pollution degree 4 CSA/FM Class II, Div. 2,
Medium conditions Liquids, bulk solids, slurries, and Groups F, G
interfaces CSA/FM Class III T4 or T6
• Relative dielectric constant εr Min. 1.5 Non-Sparking ATEX II 3 G Ex nA II T6 ... T4
• Process temperature ATEX II 2 D IP6X T100 °C

- Without thermal isolator -40 ... +85 °C (-40 ... +185 °F)2) Marine Lloyds Register of Shipping,
Categories ENV1, ENV2, and ENV5
- With thermal isolator -40 ... +125 °C (-40 ... +257 °F)
• Process pressure (rod version) -1 ... +25 bar g (-14.6 ... +365 psi g) Others Pattern Approval (China)
(nominal)
Communication PROFIBUS PA
• Process pressure (cable version)3) -1 ... +10 bar g (-14.6 ... +150 psi g) (IEC 61158 CPF3 CP3/2)
(nominal) Bus physical layer:
• Process pressure -1 ... +10 bar g (-14.6 ... +150 psi g) IEC 61158-2 MBP (IS)
(sliding coupling version) (nominal) Device profile: PROFIBUS PA profile
for Process Control Devices
Design Version 3.0, Class B FISCO field
Material device
• Enclosure Epoxy-coated aluminum with gasket 1)
When operation is in areas classified as hazardous, observe restrictions
• Optional thermal isolator 316L stainless steel according to relevant certificate. See also Pressure/Temperature curves on
Connection Removable terminal block, page 5/36.
max. 2.5 mm² 2)
Thermal isolator is used if process connection temperature exceeds 85 °C
(185 °F)
Degree of protection IP65/Type 4/NEMA 4 (optional IP68)
3)
Pressure rating of process seal is temperature dependent.
Cable inlet 2 x M20 x 1.5 thread (option: See Pressure/Temperature curves on page 5/34.
2 x ½" NPT conduit entry including 4)
1 plugged entry) Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
Electromagnetic compatibility To comply with CE EMC regulations
(where applicable); the CLS200
should be installed per the instruction
manual.

4/34 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Technical specifications (continued)


Design: Probe
Rod version Sanitary version Cable version Sliding Coupling version
Max. length 5 500 mm (216.53 inch) 5 500 mm (216.53 inch) • 30 000 mm (1 181.1 inch) 5 500 mm (216.53 inch)
liquids and slurries
• 5 000 mm (196.85 inch)
solids (under loads)
Process connection R ¾", 1", 1¼", 1½" 1½", 2" sanitary fitting clamp R ¾", ", 1¼", 1½" R ¾", 1", 1¼", 1½"
[(BSPT), EN 10226/PT (JIS-T), 316L stainless steel [(BSPT), EN 10226/PT (JIS-T), [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203] JIS B 0203] JIS B 0203]
¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT ¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1] [(Taper), ANSI/ASME B1.20.1]
G ¾", 1", 1½" G ¾", 1", 1½" G ¾", 1", 1½"
[(BSPP), EN ISO 228-1/PF [(BSPP), EN ISO 228-1/PF [(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202] (JIS-P), JIS B 0202] (JIS-P), JIS B 0202]
316L stainless steel 316L stainless steel
ASME/EN flange ASME/EN flange
Extension material 316L stainless steel
optional PFA coated1)
316L stainless steel Fluoroethylene
propylene (FEP) cable with
stainless steel core
316L stainless steel
4
Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF)
O-ring seal material FKM (optional FFKM)2) FKM (optional FFKM)2) FKM (optional FFKM)2) FKM (optional FFKM)2)
Thermal isolator3) Optional Optional Optional Optional
Extension User selected length User selected length Cable extension User selected length
1) 1
PFA coating (7ML5634 and 7ML5644) has 120 micron thickness
2)
For caustic materials, consult a local sales person for alternative O-rings. For more information, please visit http://www.automation.siemens.com/aspa_app.
3)
Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F).

Siemens FI 01 · 2021 4/35


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5640- Pointek CLS200 RF Capacitance point level 7ML5640-
switch, digital, rod design switch, digital, rod design
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, slurries, Detects level and interface in liquids, solids, slurries,
and foam. Adjustable, 5.5 m (18.04 ft), insertion, and foam. Adjustable, 5.5 m (18.04 ft), insertion,
adaptable sensitivity, with the ability to tune out adaptable sensitivity, with the ability to tune out
build-up on probe. With display and digital build-up on probe. With display and digital
communications. communications.
Click on the Article No. for the online Add Order code Y01 and plain text:
configuration in the PIA Life Cycle Portal. "Insertion length ... mm"
Extended rod, 210 ... 1 000 mm M
Process connection
(8.27 ... 39.37 inch)
Threaded, 316L stainless steel Extended rod, 1 001 ... 2 000 mm N
¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A (39.41 ... 78.74 inch)
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B Extended rod, 2 001 ... 3 000 mm P
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C (78.78 ... 118.11 inch)
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D Extended rod, 3 001 ... 4 000 mm Q
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A (118.15 ... 157.48 inch)
Extended rod, 4 001 ... 5 000 mm R
4
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D (157.52 ... 196.85 inch)
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A Extended rod, 5 001 ... 5 500 mm S
(196.89 ... 216.53 inch)
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D Thermal isolator
JIS B 0202] Without thermal isolator 0
Welded flange, 316L stainless steel, raised face With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)]
1" ASME, 150 lb 5 A
1" ASME, 300 lb 5 B Remote mount electronics and mounting bracket
1" ASME, 600 lb 5 C With 2 m (79 inch) of cable2) 2
1½" ASME, 150 lb 5 D With 5 m (197 inch) of cable2) 3
1½" ASME, 300 lb 5 E Wetted seals
1½" ASME, 600 lb 5 F FKM 0
2" ASME, 150 lb 5 G FFKM [for process temperatures above 1
2" ASME, 300 lb 5 H -20 °C (-4 °F)]
2" ASME, 600 lb 5 J Probe material
3" ASME, 150 lb 5 K 316L stainless steel with PPS probe body 0
3" ASME, 300 lb 5 L 316L stainless steel with PVDF probe body 1
3" ASME, 600 lb 5 M
4" ASME, 150 lb 5 N Approvals
4" ASME, 300 lb 5 P Non-Sparking: B
CE, RCM, ATEX II 3 G Ex nA II T6 ... T4,
4" ASME, 600 lb 5 Q ATEX II 2 D IP6X T100 °C
Welded flange, 316L stainless steel, Dust Ignition Proof: C
Type A flat faced CE, RCM, ATEX II ½ D T100 °C
DN 25, PN 16 6 A Intrinsically Safe:1) D
DN 25, PN 40 6 B CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
DN 40, PN 16 6 C ATEX II ½ D IP6X T100 °C
DN 40, PN 40 6 D Flameproof Enclosure with IS Probe: E
CE, RCM, ATEX II ½ G EEx d[ia] IIC T6 ... T4,
DN 50, PN 16 6 E
ATEX II ½ D T100 °C
DN 50, PN 40 6 F
Non-incendive: F
DN 80, PN 16 6 G CSA/FM Class I, Div. 2, Groups A, B, C, D
DN 80, PN 40 6 H CSA/FM Class II, Div. 2, Groups F, G
DN 100, PN 16 6 J CSA/FM Class III T4 or T6
DN 100, PN 40 6 K Dust Ignition Proof with IS Probe: G
(Note: flange bolting patterns and facings CSA/FM Class II, Div. 1, Groups E, F, G
dimensionally correspond to the applicable CSA/FM Class III T4
ASME B16.5 or EN 1092-1 standard.) Intrinsically Safe:1) H
Probe length CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
(length from flange face) CSA/FM Class III T4
(threaded lengths include process thread) Explosion Proof with IS Probe: J
Note: No Y01 needed in Order code for CSA/FM Class I, Div. 1, Groups A, B, C, D
standard lengths CSA/FM Class II, Div. 1, Groups E, F, G
Compact [threaded 120 mm (4.72 inch), Flanged A CSA/FM Class III T4
98 mm (3.86 inch)] General Purpose (CSA, FM) K
Extended rod, 250 mm (9.84 inch) B General Purpose (CE, RCM) L
Extended rod, 350 mm (13.78 inch) C Enclosure and lid
Extended rod, 500 mm (19.69 inch) D
Extended rod, 750 mm (29.53 inch) E Aluminum epoxy coated
Extended rod, 1 000 mm (39.37 inch) F 2 x ½" NPT via adapter - cable inlet, IP65 A
Extended rod, 1 250 mm (49.21 inch) G 2 x M20 x 1.5 cable inlet, IP65 B
Extended rod, 1 350 mm (53.15 inch) H 2 x ½" NPT via adapter - cable inlet, IP68 C
Extended rod, 1 500 mm (59.06 inch) J 2 x M20 x 1.5 cable inlet, IP68 D
Extended rod, 1 750 mm (68.90 inch) K 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe
Extended rod, 2 000 mm (78.74 inch) L protection.
2) Available with Approvals options F, G, H, J, and K.

4/36 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Selection and ordering data Order code Article No.

Further designs Pointek CLS200 RF Capacitance point level 7ML5641-


switch, digital, cable design
Please add "-Z" to Article No. 77777 - 7770
and specify Order code(s). Detects level and interface in liquids, solids, slurries,
and foam. Cable extension options to 30 m
Total insertion length: enter the total insertion length Y01 (98.43 ft), adaptable sensitivity, with the ability to
in plain text description tune out build-up on probe. With display and
Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15 digital communications.
Measuring-point number/identification Click on the Article No. for the online
(max. 27 characters) specify in plain text configuration in the PIA Life Cycle Portal.
Manufacturer's test certificate: M to DIN 55350, C11 Process connection
Part 18 and ISO 9000
Threaded, 316L stainless steel
Material inspection certificate Type 3.1 per C12 ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A
EN 10204
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B
1)
INMETRO E34 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C
Operating Instructions 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A

4
All literature is available to download for free, in a
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B
range of languages, at
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D
http://www.siemens.com/processinstrumentation/documentation G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A
Accessories See page 4/41 G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B
1) G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 D
Available only with Approvals options C and E.
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb 5 A
1" ASME, 300 lb 5 B
1" ASME, 600 lb 5 C
1½" ASME, 150 lb 5 D
1½" ASME, 300 lb 5 E
1½" ASME, 600 lb 5 F
2" ASME, 150 lb 5 G
2" ASME, 300 lb 5 H
2" ASME, 600 lb 5 J
3" ASME, 150 lb 5 K
3" ASME, 300 lb 5 L
3" ASME, 600 lb 5 M
4" ASME, 150 lb 5 N
4" ASME, 300 lb 5 P
4" ASME, 600 lb 5 Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16 6 A
DN 25, PN 40 6 B
DN 40, PN 16 6 C
DN 40, PN 40 6 D
DN 50, PN 16 6 E
DN 50, PN 40 6 F
DN 80, PN 16 6 G
DN 80, PN 40 6 H
DN 100, PN 16 6 J
DN 100, PN 40 6 K
(Note: flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)

Siemens FI 01 · 2021 4/37


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5641- Pointek CLS200 RF Capacitance point level 7ML5641-
switch, digital, cable design switch, digital, cable design
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, slurries, Detects level and interface in liquids, solids, slurries,
and foam. Cable extension options to 30 m and foam. Cable extension options to 30 m
(98.43 ft), adaptable sensitivity, with the ability to (98.43 ft), adaptable sensitivity, with the ability to
tune out build-up on probe. With display and tune out build-up on probe. With display and
digital communications. digital communications.
Probe length Enclosure and lid
(length from flange face) Aluminum epoxy coated
(threaded lengths include process thread) 2 x ½" NPT via adapter - cable inlet, IP65 A
Note: No Y01 needed in Order code for standard 2 x M20 x 1.5 cable inlet, IP65 B
lengths
2 x ½" NPT via adapter - cable inlet, IP68 C
Extended cable, 3 000 mm (118.11 inch), length A
2 x M20 x 1.5 cable inlet, IP68 D
can be determined by customer on assembly
Extended cable, 6 000 mm (236.22 inch), length B 1)
Barrier or Intrinsically Safe power supply required for Intrinsically
can be determined by customer on assembly Safe protection.
2)
Available with Approvals options F, G, H, J, and K.
4
Add Order code Y01 and plain text: "Insertion
length ... mm"
Extended cable, 500 ... 5 000 mm C
(19.69 ... 196.85 inch) Further designs Order code
Extended cable, 5 001 ... 10 000 mm D
Please add "-Z" to Article No.
(196.89 ... 393.70 inch)
and specify Order code(s).
Extended cable, 10 001 ... 15 000 mm E
(393.74 ... 590.55 inch) Total insertion length: enter the total insertion length Y01
Extended cable, 15 001 ... 20 000 mm F in plain text description
(590.59 ... 787.40 inch) Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15
Extended cable, 20 001 ... 25 000 mm G Measuring-point number/identification
(787.44 ... 984.25 inch) (max. 27 characters) specify in plain text
Extended cable, 25 001 ... 30 000 mm H
Manufacturer's test certificate: M to DIN 55350, C11
(984.29 ... 1 181.10 inch)
Part 18 and ISO 9000
Thermal isolator
Material inspection Certificate Type 3.1 per C12
Without thermal isolator 0 EN 10204
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)] INMETRO1) E34

Remote mount electronics and mounting bracket Operating Instructions


With 2 m (79 inch) of cable2) 2 All literature is available to download for free, in a
With 5 m (197 inch) of cable2) 3 range of languages, at
Wetted seals http://www.siemens.com/processinstrumentation/documentation
FKM and PTFE 0 Accessories See page 4/41
FFKM and PTFE [for process temperatures above 1
1)
-20 °C (-4 °F)] Available only with Approvals options C and E.
Probe material
FEP jacketed cable with PPS probe body 0
FEP jacketed cable with PVDF probe body 1
Approvals
Non-Sparking: B
CE, RCM, ATEX II 3 G Ex nA II T6 ... T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof: C
CE, RCM, ATEX II ½ D T100 °C
Intrinsically Safe:1) D
CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
ATEX II ½ D IP6X T100 °C
Flameproof Enclosure with IS Probe: E
CE, RCM, ATEX II ½ G EEx d[ia] IIC T6 ... T4,
ATEX II ½ D T100 °C
Non-incendive: F
CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe: G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Intrinsically Safe:1) H
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe: J
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM) K
General Purpose (CE, RCM) L

4/38 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5642- Pointek CLS200 RF Capacitance point level 7ML5642-
switch, digital, sanitary rod design. switch, digital, sanitary rod design.
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, slurries, Detects level and interface in liquids, solids, slurries,
and foam. Adjustable, 5.5 m (18.04 ft), insertion, and foam. Adjustable, 5.5 m (18.04 ft), insertion,
adaptable sensitivity, with the ability to tune out adaptable sensitivity, with the ability to tune out
build-up on probe. With display and digital build-up on probe. With display and digital
communications. communications.
Click on the Article No. for the online Non-incendive: F
configuration in the PIA Life Cycle Portal. CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
Process connection CSA/FM Class III T4 or T6
Sanitary 316L stainless steel Dust Ignition Proof with IS Probe: G
1" sanitary fitting clamp 8 A CSA/FM Class II, Div. 1, Groups E, F, G
1½" sanitary fitting clamp 8 B CSA/FM Class III T4
2" sanitary fitting clamp 8 C Intrinsically Safe:1) H
2½" sanitary fitting clamp 8 D CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
3" sanitary fitting clamp 8 E
CSA/FM Class III T4
(Note: Sanitary connection dimensionally
corresponds to the applicable ISO 2852 standard.)
Probe length
Explosion Proof with IS Probe:
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
J
4
(length from process connection face) CSA/FM Class III T4
General Purpose (CSA, FM) K
Note: No Y01 needed in Order code for
standard lengths General Purpose (CE, RCM) L
Compact, 98 mm (3.86 inch) A Enclosure and lid
Extended rod, 250 mm (9.84 inch) B Aluminum epoxy coated
Extended rod, 350 mm (13.78 inch) C 2 x ½" NPT via adapter - cable inlet, IP65 A
Extended rod, 500 mm (19.69 inch) D 2 x M20 x 1.5 cable inlet, IP65 B
Extended rod, 750 mm (29.53 inch) E 2 x ½" NPT via adapter - cable inlet, IP68 C
Extended rod, 1 000 mm (39.37 inch) F 2 x M20 x 1.5 cable inlet, IP68 D
Extended rod, 1 250 mm (49.21 inch) G
1)
Extended rod, 1 350 mm (53.15 inch) H Barrier or Intrinsically Safe power supply required for Intrinsically
Extended rod, 1 500 mm (59.06 inch) J Safe protection.
2)
Extended rod, 1 750 mm (68.90 inch) K Available with Approvals options F, G, H, J, and K.
Extended rod, 2 000 mm (78.74 inch) L
Add Order code Y01 and plain text:
"Insertion length ... mm" Further designs Order code
Extended rod, 110 ... 350 mm M Please add "-Z" to Article No.
(4.3 ... 13.78 inch) and specify Order code(s).
Extended rod, 351 ... 1 000 mm N
(13.82 ... 39.37 inch) Total insertion length: enter the total insertion length Y01
in plain text description
Extended rod, 1 001 ... 2 000 mm P
(39.41 ... 78.74 inch) Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15
Extended rod, 2 001 ... 3 000 mm Q Measuring-point number/identification
(78.78 ... 118.11 inch) (max. 27 characters) specify in plain text
Extended rod, 3 001 ... 4 000 mm R Manufacturer's test certificate: M to DIN 55350, C11
(118.15 ... 157.48 inch) Part 18 and ISO 9000
Extended rod, 4 001 ... 5 000 mm S
(157.52 ... 196.85 inch) Material inspection Certificate Type 3.1 per C12
Extended rod, 5 001 ... 5 500 mm T EN 10204
(196.89 ... 216.53 inch) INMETRO1) E34
Thermal isolator
Operating Instructions
Without thermal isolator 0
With thermal isolator [for process connection 1 All literature is available to download for free, in a
temperatures over 85 °C (185 °F)] range of languages, at
Remote mount electronics and mounting bracket http://www.siemens.com/processinstrumentation/documentation
With 2 m (79 inch) of cable2) 2 Accessories See page 4/41
With 5 m (197 inch) of cable2) 3
1)
Wetted seals Available only with Approvals options C and E.
FKM 0
FFKM [for process temperatures above 1
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body 0
316L stainless steel with PVDF probe body 1
Approvals
Non-Sparking: B
CE, RCM, ATEX II 3 G Ex nA II T6 ... T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof: C
CE, RCM, ATEX II ½ D T100 °C
Intrinsically Safe:1) D
CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
ATEX II ½ D IP6X T100 °C
Flameproof Enclosure with IS Probe: E
CE, RCM, ATEX II ½ G EEx d[ia] IIC T6 ... T4,
ATEX II ½ D T100 °C

Siemens FI 01 · 2021 4/39


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Selection and ordering data Article No. Article No.

Pointek CLS200 RF Capacitance point level 7ML5643- Pointek CLS200 RF Capacitance point level 7ML5643-
switch, digital, sliding coupling design. switch, digital, sliding coupling design.
77777 - 7770 77777 - 7770
Detects level and interface in liquids, solids, slurries, Detects level and interface in liquids, solids, slurries,
and, foam. Adjustable, 5.5 m (18.04 ft), insertion, and, foam. Adjustable, 5.5 m (18.04 ft), insertion,
adaptable sensitivity, with the ability to tune out adaptable sensitivity, with the ability to tune out
build-up on probe. With display and digital build-up on probe. With display and digital
communications. communications.
Click on the Article No. for the online Flameproof Enclosure with IS Probe: E
configuration in the PIA Life Cycle Portal. CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
ATEX II 1/2 D T100 °C
Process connection
Non-incendive: F
Threaded, 316L stainless steel CSA/FM Class I, Div. 2, Groups A, B, C, D
¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A CSA/FM Class II, Div. 2, Groups F, G
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B CSA/FM Class III T4 or T6
1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C Dust Ignition Proof with IS Probe: G
1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A
Intrinsically Safe:1) H

4
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B CSA/FM Class I, Div. 1, Groups A, B, C, D
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D CSA/FM Class II, Div. 1, Groups E, F, G
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A CSA/FM Class III T4
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B Explosion Proof with IS Probe: J
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 D CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
Probe length CSA/FM Class III T4
(length from flange face) General Purpose (CSA, FM) K
(threaded lengths include process thread) General Purpose (CE, RCM) L
Note: No Y01 needed in Order code for Enclosure and lid
standard lengths
Extended rod, 350 mm (13.78 inch) C Aluminum epoxy coated
Extended rod, 500 mm (19.69 inch) D 2 x ½" NPT via adapter - cable inlet, IP65 A
Extended rod, 750 mm (29.53 inch) E 2 x M20 x 1.5 cable inlet, IP65 B
Extended rod, 1 000 mm (39.37 inch) F 2 x ½" NPT via adapter - cable inlet, IP68 C
Extended rod, 1 250 mm (49.21 inch) G 2 x M20 x 1.5 cable inlet, IP68 D
Extended rod, 1 350 mm (53.15 inch) H 1)
Barrier or Intrinsically Safe power supply required for Intrinsically
Extended rod, 1 500 mm (59.06 inch) J Safe protection.
Extended rod, 1 750 mm (68.90 inch) K 2)
Available with Approvals options F, G, H, J, and K.
Extended rod, 2 000 mm (78.74 inch) L
Add Order code Y01 and plain text:
"Insertion length ... mm" Further designs Order code
Extended rod, 350 ... 1 000 mm M
(13.82 ... 39.37 inch) Please add "-Z" to Article No.
and specify Order code(s).
Extended rod, 1 001 ... 2 000 mm N
(39.41 ... 78.74 inch) Total insertion length: enter the total insertion length Y01
Extended rod, 2 001 ... 3 000 mm P in plain text description
(78.78 ... 118.11 inch)
Stainless steel tag [70 x 13 mm (2.75 x 0.5 inch)]: Y15
Extended rod, 3 001 ... 4 000 mm Q Measuring-point number/identification
(118.15 ... 157.48 inch) (max. 27 characters) specify in plain text
Extended rod, 4 001 ... 5 000 mm R
(157.52 ... 196.85 inch) Manufacturer's test certificate: M to DIN 55350, C11
Extended rod, 5 001 ... 5 500 mm S Part 18 and ISO 9000
(196.89 ... 216.53 inch) Material inspection Certificate Type 3.1 per C12
Thermal isolator EN 10204
Without thermal isolator 0 INMETRO1) E34
With thermal isolator [for process connection 1
temperatures over 85 °C (185 °F)] Operating Instructions

Remote mount electronics and All literature is available to download for free, in a
mounting bracket range of languages, at
With 2 m (79 inch) of cable2) 2 http://www.siemens.com/processinstrumentation/documentation
With 5 m (197 inch) of cable2) 3
Accessories See page 4/41
Wetted seals 1)
FKM and PTFE 0 Available only with Approvals options C and E.
FFKM and PTFE [for process temperatures above 1
-20 °C (-4 °F)]
Probe material
316L stainless steel with PPS probe body 0
316L stainless steel with PVDF probe body 1
Approvals
Non-Sparking: B
CE, RCM, ATEX II 3 G Ex nA II T6 ... T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof: C
CE, RCM, ATEX II 1/2 D T100 °C
Intrinsically Safe:1) D
CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
ATEX II 1/2 D IP6X T100 °C

4/40 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Selection and ordering data Article No. ■ Options


Accessories
Optional SensGuard
SensGuard, ¾" NPT (PPS). 7ML1830-1DL
Only available for CLS200 with ¾" NPT thread. Internal thread ¾" NPT

SensGuard, R 1" (BSPT) (PPS). 7ML1830-1DM


Only available for CLS200 with ¾" NPT thread.

(1.26)

(1.26)
32

32
One metallic cable gland M20 x 1.5, -40 ... +80 °C 7ML1930-1AQ Process
Process connection
(-40 ... +176 °F), Dust Ignition Proof, with integrated connection R 1" (BSPT)
shield connection (available for PROFIBUS PA) ¾" NPT
General Purpose

91 (3.6)

91 (3.6)
½" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA

70 (2.75)

70 (2.75)
NEMA 6, -40 ... +80 °C (-40 ... +176 °F),
Dust Ignition Proof, cable size 6 ... 12 mm
(0.236 ... 0.472 inch)
M20 x 1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC
NEMA 6, -40 ... +80 °C (-40 ... +176 °F),
Dust Ignition Proof, cable size 7 ... 12 mm
(0.275 ... 0.472 inch)
Hazardous Locations
Optional SensGuard, dimensions in mm (inch) 4
1/2" NPT EMC rated Cable Gland: Dust Ignition 7ML1830-1JB
Proof, Flameproof Exd, and Increased Safety
ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21,
Zone 22, and in Gas Groups IIA, IIB and IIC)
60 ... +80 °C IP66, IP67, IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD
Flameproof Exd, and Increased Safety ATEX II 2
GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22
and in Gas Groups IIA, IIB and IIC)
60 ... +80 °C IP66, IP67, IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
Blind threaded flanges are available.
Customers interested in a custom designed device
should consult a local sales person.
For more information, please visit
http://www.automation.siemens.com/aspa_app.
Pointek Specials See page 4/70

Siemens FI 01 · 2021 4/41


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Characteristic curves
Pressure/temperature curve
CLS200 sliding coupling
threaded process connections
(7ML5633 and 7ML5643)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
4 -40 ºF 14 ºF
(-40 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C

Pointek CLS200 process pressure/temperature derating curves (7ML5633 and 7ML5643)

Pressure/temperature curve
CLS200 cable
Threaded process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 process pressure/temperature derating curves (7ML5631 and 7ML5641)

4/42 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Characteristic curves (continued)


Pressure/temperature curve
CLS200 compact and extended rod
Threaded process connections
(7ML5630 and 7ML5640)

Permitted operating pressures P

40 bar (580 psi)

30 bar (435 psi)

20 bar (290 psi)

4
Atmospheric 10 bar (145 psi)
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 process pressure/temperature derating curves (7ML5630 or 7ML5640)

Pressure/temperature curve
CLS200 compact and extended sanitary type
Sanitary process connections
(7ML5632 and 7ML5642)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

Pointek CLS200 process pressure/temperature derating curves (7ML5632 and 7ML5642)

Siemens FI 01 · 2021 4/43


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Characteristic curves (continued)


Pressure/temperature curve
CLS200, cable
ASME flanged process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric

4 -40 ºF 14 ºF
(-40 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC)
500 ºF
(260 ºC)
600 ºF
(315 ºC)
700 ºF
(371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5631 and 7ML5641)

Pressure/temperature curve
CLS200 compact and extended rod
ASME flanged process connections
(7ML5630 and 7ML5640)

Permitted operating pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)


ASME 300 lb1)

20 bar (290 psi)

10 bar (145 psi) ASME 150 lb1)


Atmospheric
-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5630 and 7ML5640)

4/44 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Characteristic curves (continued)


Pressure/temperature curve
CLS200 cable
EN flanged process connections
(7ML5631 and 7ML5641)

Permitted operating pressures P

30 bar (435 psi)

20 bar (290 psi)

10 bar (145 psi)


PN 161)
Atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
100 ºF
(38 ºC)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
400 ºF
(204 ºC)
500 ºF
(260 ºC)
600 ºF
(315 ºC)
700 ºF
(371 ºC) 4
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted operating temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5631 and 7ML5641)

Pressure/Temperature Curve
CLS200 Compact and Extended Rod
EN Flanged Process Connections
(7ML5630 and 7ML5640)

Permitted Operating Pressures P

50 bar (725 psi)

40 bar (580 psi)

30 bar (435 psi)

PN 401)
20 bar (290 psi)

Atmospheric 10 bar (145 psi) PN 161)


-40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 500 ºF 600 ºF 700 ºF
(-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (315 ºC) (371 ºC)
-1 bar (-14.5 psi)
-150 ºC -100 ºC -50 ºC 0 ºC RT 50 ºC 100 ºC 150 ºC 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC
(-238 ºF) (-148 ºF) (-58 ºF) (32 ºF) (122 ºF) (212 ºF) (302 ºF) (392 ºF) (482 ºF) (572 ºF) (662 ºF) (752 ºF)
-29 ºC
Permitted Operating Temperature T
(-20 ºF)

1) The curve denotes the minimum allowable flange class for the shaded area below.

Pointek CLS200 process pressure/temperature derating curves (7ML5630 and 7ML5640)

Siemens FI 01 · 2021 4/45


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Dimensional drawings

Compact version Extended rod version Extended cable version


Threaded Threaded Threaded
(7ML5630 and 7ML5640) (7ML5630 and 7ML5640) (7ML5631 and 7ML5641)

Electronics/
enclosure

Y01 (insertion length)


(4.7)
120

22
(0.87)

PPS or optional 316L stainless


PVDF probe steel extension

Y01 (insertion length)


Ø20 (0.79) FEP insulated

4 cable Ø6 (0.3)

(3.3)
84
PPS or optional
Sanitary compact version
PVDF probe
Sanitary fitting 316L stainless steel
(7ML5632 and 7ML5642) sensor weight
Min. insertion length = 200 (7.87)
Max. insertion length = 5 500 (216)
Ø20 (0.79)

(3.3)
84
316L stainless steel PPS or optional
sanitary process PVDF probe
connection
Min. insertion length = 500 (19.69)
(3.8)
98

Max. insertion length = 30 000 (1 181)


PPS or optional
Applicable for liquids and solids
PVDF probe
applications. Cable can be shortened
on site.

2 cable entries Sanitary extended version Sliding coupling version


½" NPT or Sanitary fitting Threaded
M20 x 1.5 (7ML5632 and 7ML5642) (7ML5633 and 7ML5643)

M20: 135 (5.32)


½" NPT: 150 (5.91)

Lid with window 316L stainless steel


sanitary process
connection
Y01 (insertion length)

316L stainless
GP, DIP lid,
without window 316L stainless steel sliding
steel extension coupling
Y01 (insertion length)
139 (5.47)

Ø24 (0.95)
XP, lid without window
132 (5.20)

(3.8)
226 (8.90)

98

PPS or optional
219 (8.62)

PVDF probe
(4.96)

Min. 215
126

(8.46)
213 (8.39)

Min. insertion length = 110 (4.3) Ø20 (0.79)


Max. insertion length = 5 500 (216)
Thermal
(3.3)
84

isolator PPS or optional


PVDF probe

Min. insertion length = 350 (13.82)


Max. insertion length = 5 500 (216)

Pointek CLS200 threaded/sanitary process connections, dimensions in mm (inch)

4/46 Siemens FI 01 · 2021


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Dimensional drawings (continued)


Compact version Extended rod version Extended cable version
Welded Flange (7ML5630 and 7ML5640) Welded Flange (7ML5630 and 7ML5640) Welded Flange
Welded Flange, PFA coated Welded Flange, PFA coated (7ML5631 and 7ML5641)
(7ML5634 and 7ML5644) (7ML5634 and 7ML5644)

Electronics/
enclosure

Y01 (insertion length)


(3.8)

316L stainless
98

PPS or optional steel extension


PVDF probe (or PFA coated

Y01 (insertion length)


Ø20 (0.79) FEP insulated
2 cable entries
½" NPT or cable Ø6 (0.3)
4
(3.3)
84
M20 x 1.5 PPS or optional
PVDF probe
M20: 135 (5.32) 316L stainless steel
½" NPT: 150 (5.91) sensor weight
Min. insertion length = 200 (7.87)
Lid with window Max. insertion length = 5 500 (216)
Ø20 (0.79)

(3.3)
84
GP, DIP lid, PPS or optional
without window PVDF probe

Min. insertion length = 500 (19.69)


Max. insertion length = 30 000 (1 181)
Applicable for liquids and solids applica-
161 (6.34)

XP, lid without window tions. Cable can be shortened on site.


154 (6.06)

249 (9.80)
242 (9.53)
(5.83)

Flange Facing (raised face)


148

236 (9.29)

Flange Class Facing thickness


Thermal ASME 150/300 2 (0.08)
isolator
ASME 600/900 7 (0.28)
PN16/40 2 (0.08)

Insertion length does not include any raised face/gasket face dimension
(see Flange Facing Table above)

Pointek CLS200 flanged process connections, dimensions in mm (inch)

Siemens FI 01 · 2021 4/47


© Siemens 2020

Level measurement
Point level measurement
RF Capacitance switches
Pointek CLS200 - Digital

■ Circuit diagrams

Wiring: Pointek CLS200 standard


White
Black
Red P2
Trip
point
(+)

(f )

Switch bank
P1 S1 K1
OFF
GND

- + 3 2 1 K4
Delay Sensor
L1 L3
Sensor Power 1 2 3
L2 status on
Output Power

4
status supply
12 to 250 V AC/DC

NC NO NO
K2 K3
Solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
Relay contact:
8 A at 250 V AC, 2 000 VA
5 A at 30 V DC, 150 W
Notes:
- Identification label is on underside of lid. Switch and potentiometer settings
are for illustration purposes only (refer to operation/setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction Manual or contact Siemens representative for detailed
wiring information.

Wiring: Pointek CLS200 Digital

White
Reed
Test input contact*
White

Red (+)

Sensor Black (-)


Alarm output
solid-state switch Orange (f)

24 V DC/PROFIBUS PA

Power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the instruction manual or contact a Siemens representative
for detailed wiring information.

*Magnet activated sensor Test


A magnet can be used to test the sensor without opening the lid of the
Pointek CLS200 Digital version. Bring the magnet close to the test
area indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.

Pointek CLS200 connections

4/48 Siemens FI 01 · 2021

You might also like