You are on page 1of 34

Product data sheet 17044

Characteristics Domae MCB - miniature circuit-breaker - 1P -


6A - C Curve - 6000A

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range Domae
Product or component type Miniature circuit-breaker
Device short name Domae MCB
Device application Distribution
Poles description 1P
Number of protected poles 1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
[In] rated current 6 A

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity Icn 6000 A

Complementary
Network frequency 50/60 Hz
[Ue] rated operational voltage 230 V AC 50/60 Hz
Magnetic tripping limit 5...10 x In
[Ics] rated service breaking capacity 6000 KA 100 % x Icn conforming to EN/IEC 60898-1
Contact position indicator Yes
Control type Toggle
Local signalling Fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility YES
9 mm pitches 2
Height 81 Mm
Width 18 Mm
Depth 78.5 Mm
Net weight 0.095 Kg
Colour White
Mechanical durability 20000 Cycles
Connections - terminals Tunnel type terminals (top or bottom) - 1...25 mm² - rigid
Tunnel type terminals (top or bottom) - 1...16 mm² - flexible
Wire stripping length 14 Mm for top or bottom connection
Tightening torque 2 N.M top or bottom
Earth-leakage protection Without

Mar 10, 2021


1
Environment
Standards IEC 60898-1
IEC 60529
IEC 60068-1
IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -40…70 °C

Packing Units
Package 1 Weight 0.096 Kg
Package 1 Height 0.750 Dm
Package 1 width 0.180 Dm
Package 1 Length 0.850 Dm

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Compliant EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Product Life Status : Commercialised

2
BCG0524
AUTOMATIC BATTERY CHARGER, SWITCHING BCG SERIES, FOR SEALED AND NOT
SEALED LEAD-ACID BATTERIES, 1 CHARGING LEVEL. 24VDC OUTPUT, 5A

Automatic battery
Product designation
chargers
Product type designation BCG
Single phase
automatic battery
charger 1
Type charging level for
sealed and non-
sealed lead-acid
batteries
Power supply
Rated voltage Us
min VAC 110
Max VAC 240 ±10%
Operational frequency
min Hz 50 ±10%
max Hz 60 ±10%
Power consumption
Max VA 364
Max W 158
Internal fuse A 6.3
Charging cycle
Reference standards IEC62368-1
non-sealed and
Battery type sealed lead-acid
batteries
Battery voltage VDC 24
in pos. V1:27.6;
Charging voltage (Uc)
V2:27.0
Boost % Uc +4.4
Charging current (Ic) 5
Charging current adjustment % Ic 20 to 100
Main supply fuse;
charging
inhibition due to:
1. Short circuit at
battery terminals;
Protections
2. Reverse
battery polarity; 3.
Low voltage at
battery poles; 4.
Output overload.
Indications
LED indicator for operating status Yes
LED reverse battery polarity Yes
Alarm output circuit
Output type 1 relay

The characteristics described in this document are subject to updates or modifications at any time. The descriptions, technical and
BCG0524 1/3
functional information, illustrations and instructions in this brochure are purely illustrative, and are consequently not contractually binding
BCG0524
AUTOMATIC BATTERY CHARGER, SWITCHING BCG SERIES, FOR SEALED AND NOT
SEALED LEAD-ACID BATTERIES, 1 CHARGING LEVEL. 24VDC OUTPUT, 5A

Rated capacity 5A 30VDC


Mechanical features
Internal panel
Housing type
mount
Terminals type Fixed
35mm DIN rail or
Fixing
Screw fixing
Weight g 532
Ambient conditions
Temperature
Operating temperature
min °C -30
max °C +55
Storage temperature
min °C -30
max °C +80
Protection degree IP20
Dimensions

Wiring diagrams

The characteristics described in this document are subject to updates or modifications at any time. The descriptions, technical and
BCG0524 2/3
functional information, illustrations and instructions in this brochure are purely illustrative, and are consequently not contractually binding
BCG0524
AUTOMATIC BATTERY CHARGER, SWITCHING BCG SERIES, FOR SEALED AND NOT
SEALED LEAD-ACID BATTERIES, 1 CHARGING LEVEL. 24VDC OUTPUT, 5A

Certifications and compliance


Compliance
CSA C22.2 n°60950-1
IEC/EN 60950-1
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 60950-1
Certificates
cURus
EAC

The characteristics described in this document are subject to updates or modifications at any time. The descriptions, technical and
BCG0524 3/3
functional information, illustrations and instructions in this brochure are purely illustrative, and are consequently not contractually binding
Product data sheet LV847130
Characteristics Circuit breaker Masterpact MTZ1 10H1, 1000
A, 3P fixed, without Micrologic

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range Masterpact
Product name Masterpact MTZ1
Device short name MTZ1 10 H1
Product or component type Circuit breaker
Device application Protection
Poles description 3P

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Network type AC

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Network frequency 50/60 Hz
Breaking capacity code H1
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B

Complementary
Control type Push-button
Mounting mode Fixed
Mounting support Rails
Base plate
[In] rated current 1000 A at 40 °C
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 12 KV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity 88 KA 220/415 V AC at 50/60 Hz
88 KA 440 V AC at 50/60 Hz
88 KA 500/525 V AC at 50/60 Hz
88 KA 660/690 V AC at 50/60 Hz
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating 630 A
400 A
800 A
1000 A
Breaking capacity 42 KA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 42 KA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 12500 Cycles with periodic preventive maintenance conforming to IEC 60947-2

Mar 10, 2021


1
Electrical durability 3000 Cycles 690 V AC 50/60 Hz conforming to IEC 60947-2
6000 Cycles 440 V AC 50/60 Hz conforming to IEC 60947-2
AC-23A: 3000 cycles 690 V AC 50/60 Hz conforming to IEC 60947-3
AC-23A: 6000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-3
AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-3
Connection pitch 70 Mm
[Icw] rated short-time withstand current 42 KA 0.5 s conforming to IEC 60947-2
42 KA 1 s conforming to IEC 60947-2
24 KA 3 s conforming to IEC 60947-2
Maximum breaking time 25 Ms
Maximum closing response time 50 Ms
Height 301 Mm
Width 276 Mm
Depth 209.5 Mm

Environment
Standards IEC 60364-8-1
IEC 60947-2
Product certifications LCIE
ASEFA
Pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information

Product Life Status : Commercialised

2
Product data sheet METSECT5DB100
Characteristics current transformer tropicalised 1000 5 double
output for bars 38x127

Main

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Range PowerLogic
Product name CT
Product or component type Current transformer
Secondary current 5 A
Accuracy class Class 0.5 at 6 VA
Class 1 at 10 VA
[In] rated current 1000 A

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Complementary
Current transformer type Tropicalised for busbar
Current transformer ratio 1000/5
[Ith] conventional free air thermal current 60 KA
Dynamic withstand current 2.5 Ith
Maximum safety factor 5
[Ue] rated operational voltage < 720 V AC 50/60 Hz
[Ui] rated insulation voltage 3 KV
Mounting mode Insulated locking screw
Mounting support Busbar
Width 38 Mm inner:
99 Mm outside:
Height 127 Mm inner:
160 Mm outside:
Depth 40 Mm frame:
78.4 Mm total:
Net weight 0.682 Kg
[Uimp] rated impulse withstand voltage 3 KV
Electrical insulation class Class B
Opening of bars 127 x 38
Sealing With

Environment
Standards VDE 0414
IEC 61869-2
Product certifications CE
IP degree of protection IP20
Relative humidity 0…95 %
Ambient air temperature for operation -25…60 °C

Mar 10, 2021


1
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 721 G
Package 1 Height 10 Cm
Package 1 width 13.5 Cm
Package 1 Length 17 Cm
Unit Type of Package 2 S03
Number of Units in Package 2 10
Package 2 Weight 7.617 Kg
Package 2 Height 30 Cm
Package 2 width 30 Cm
Package 2 Length 40 Cm

Offer Sustainability
EU RoHS Directive
Compliant EU RoHS Declaration
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Product Life Status : Commercialised

2
InteliATS NT

AUTO TRANSFER SWITCH CONTROLLER

Description
The InteliATSNT controllers are designed
to monitor the incoming AC mains
supply (1 or 3 phases) for under voltage,
over voltage, under frequency, over
frequency and voltage unbalance. In the
case of any mains supply disproportion
it will send a remote start command to
the generating set and make change
over for both generator and mains
contactors. The gen-set requires a
remote start type control unit (e.g. the
ComAp InteliLiteNT MRS 10 controller).

The products belong to the new


family of controllers that fulfills every
requirement from simple to complex
applications – with specific models
providing modem and Internet control,
user configuration and complete gen-
set monitoring and protection.

Both InteliATSNT controllers are easy to


use with an intuitive user interface and
graphic display. The PWR model also
features a built-in event and performance
log with backed-up real time clock
making troubleshooting even simpler.
WebSupervisor
The WebSupervisor system, a secure cloud-based remote monitoring system which allows
equipment fitted with various types ComAp units to be monitored via the Internet from
a remote PC or other web enabled device such as smartphone, webbook, etc. It operates
in any Internet browser and needs no special software to be installed. User can view
recorded data from their equipment, receive email alerts on alarms and control the remote
Benefits
units. Dedicated applications for iPhone and Android provide a truly mobile constant
connection with the monitored equipment.
 Transfer between mains
and generator power
LOCATE  Open delayed transition
ComAp’s LOCATE system uses the power of mobile communications technology to provide
users and peace of mind that the monitored asset is where it should be. LOCATE provides  Open in phase transition
location data to the WebSupervisor system without the need for costly GPS positioning
equipment and works anywhere there is a mobile phone signal, even indoors. Not only will
(passive synchronization)
WebSupervisor show the position of the monitored equipment, it will also maintain a track  Closed transition (short time
history and show route of the movement on a map.
LOCATE – Simply Here! parallel, passive synchronization)
 On-site controller configuration
AirGate  Less wiring and components
Modern communications made simple. ComAp’s powerful AirGate technology is provided  Less engineering and programming
in a range of our controllers and makes remote Internet connection to the ComAp
controller easy. Just register the AirGate enabled controller on our website and from then  Remote monitoring reduced call-out
on let ComAp’s unique system locate and maintain contact with the controller, no need to
worry about VPNs, static IP addresses or corporate firewalls, simple! costs of service engineers
“AirGate – Simply connected.”  Active SMS / emails
 Perfect price / performance ratio
 History log – easy troubleshooting
and warranty claim handling
ComAp is a member of ComAp products meet the highest
AMPS (The Association of standards, with every stage of production
Manufacturers of Power undertaken in accordance with the ISO
MEMBER generating Systems). certification obtained in 1998.
Features
 3 phase ATS function  Event and performance log + RTC 1)  Mechanical and operation parameters
• Over/Under frequency • Event based history (119 records) • Unit dimension 120 × 180 mm
• Over/Under voltage • Reason, date and time + all • Sealed front face rated for IP65
• Voltage asymmetry important values are stored • Hard plexiglass LCD cover
• Battery backed-up RTC • Operation temperature:
 3 phase generator protections • Test Run scheduler • -20°C to +70°C
• Over / Under frequency • Power supply voltage 8–36 V
• Over / Under voltage  User interface • Voltage drops shorter than
• Current 1) /Voltage asymmetry • Graphic 128 × 64 pixels display 50 ms do not affect operation
• Overcurrent 1) / Overload 1) • 2 languages, user changeable from
PC (default English + Chinese) Accessories
 True RMS Voltage measurement • Setpoints adjustable via
• 3 phase generator and controller buttons or PC  IL-NT RS232 – RS232 extension board
mains voltages • Buttons with mechanical feedback  IL-NT RS232-485 – Dual
• Voltage range 277 V p-n, 480 V p-p port extension board
• Maximal measured  Inputs and outputs  IL-NT S-USB – Service USB module
voltage 300 V p-n • 4 or 7 1) binary inputs  IB-Lite – Internet/Ethernet
• PT ratio range 0.1–500 • 4 or 7 1) binary outputs module including Web server
 IL-NT GPRS – GSM modem/
 True RMS current measurements 1)  Active SMS/emails 1) wireless Internet module
• 3 generator phase currents • 2 channels  IL-NT BIO8 – Binary input/
• Current range 5 A • SMS or emails output module
• Maximal measured current 10 A  IL-NT AOUT8 – Analog outputs
• CT ratio range 1–5000  Communication interfaces for PWM gauges module
• CT location: generator, load • Optional RS232 (including  IL-NT RD (SW) – Remote display
Modem support), RS485 or software for the master controller
 Power measurements 1) USB plug-in interface
• Active / Reactive Power and • Modbus RTU / TCP (requires
Power Factor per phase RS485 interface / IB-Lite)
PC tools
• Active and Reactive Energy counter • Optional Internet connection  LiteEdit – PC configuration
• Apparent power with Ethernet via IB-Lite and monitoring tool
• Active and Reactive • Online control and monitoring  WebSupervisor – Cloud-based
Generator Energy counter over web pages via IB-Lite system for monitoring and
• Active and Reactive Mains (embedded Web server) controlling of ComAp controllers
Energy counter • Optional GSM modem/wireless  WinScope – Special graphical
Internet via IL-NT GPRS controllers’ monitoring software
KEY  InteliMonitor – PC monitoring tool
1) Only for InteliATSNT PWR model

Available models

STD PWR
AUTOMATIC TRANSFER AUTOMATIC TRANSFER
SWITCH CONTROLLER SWITCH CONTROLLER
WITH POWER MEASURING

 4 binary inputs  7 binary inputs  Passive synchronisation


 4 binary outputs  7 binary outputs  High tariff avoidance
 Gen-set remote start  Gen-set remote start  Generator connection types
 ATS, MCB and GCB control  ATS, MCB and GCB control
 High tariff avoidance  Power measuring
 Generator connection types  Event and performance log

Order codes
Product Order code Product Order code

InteliATSNT STD IA-NT STD InteliATSNT PWR IA-NT PWR

InteliATSNT
Schematic diagram

or
-USB
IL-NT S
+24V or
5
S232-48
IL-NT R
S232
IL-NT R
or
PRS
PLY IL-NT G
R SUP B

ALA
POWE VDC
8 to 36 ION IB-Lite
- UNICAT LE

RM
+ COMM MODU

STO
PLUG-IN
UTS
Y OUTP

P
)
BINAR OLLECTOR
C
(OPEN
TS STD
Y INPU 1×
BINAR 4× PWR
3× STD
SION
EXTEN MODULE 6x PWR
NT
TS
N
PLUG-I

InteliA MAINS

MEA
ATOR
GENER

VOL

SUR
MEA

TAG
IO8

EME
IL-NT B LER
NTROL

VOL
CUR

SUR
Y
ET CO BINAR

E
GEN-S

NT
TAG
INPUT

REN

EME
or Y
BINAR
T
OUTPU

E
T

NT
(OPEN TOR)
LL E C
O model

GEN
C
r PWR

MAIN
A Only fo

ERA
nnect: ),

SC
e to co D (SW
Possibl EM, IL-NT R T

TOR
B

.B. C
O D ERNE
Gen

T8 M

3ph
C ,
IL-NT AOU P
A /P LC, INT
Gen

SCA D

C.B

ONT
Rea

MAINS

3ph

. CO
3ph
Star

dy T

ROL
t/Sto

NTR
o Lo
p

OL
ad

LOAD

GAS ENGINE
DIESEL/
ER
NTROLL 10) )
ET CO NTMMRRSS10
GEN-S T
teliLite
(e.g. In

ATOR
GENER

Typical application

OPEN / DELAYED TRANSITION


AUTO/MANUAL TRANSFER Transfer
demand

Description:
d
to loa
Ready

 Stand-by gen-set. InteliATSNT continuously TS


NT
Start
/ Stop

InteliA 10
monitors mains supply for under voltage, ENGINE
InteliLit
eNT MRS

ROOM
over voltage, under frequency, over GEN-S
ET

frequency and voltage unbalance. In the


case of mains failure it sends a remote
start command to the standby gen-set.
 InteliATSNT waits for “Ready To Load” signal
or standby gen-set voltage – configurable - OFF
ICE

and switches load to the standby generator.


 After the mains returns the InteliATSNT
T
RKE
switches load back to mains and sends remote MA

stop command to the standby gen-set.


 Different delay intervals can be set
for individual changeover phases.
 The changeover can take place also on
explicit demand, not only after mains failure. MA
INS

 ATS function works with backup battery or


in reduced mode without backup battery.

Scope of supply:

 1× InteliATSNT STD
 1× arbitrary gen-set controller (e.g. InteliLiteNT MRS 10) or key start box

InteliATSNT
Functions chart

Product InteliATSNT STD InteliATSNT PWR InteliLite NT MRS 10


Order code IA-NT STD IA-NT PWR IL-NT MRS10

Binary inputs/outputs 4/4 7/7 6/6

Analog inputs – – 3

Magnetic pick-up – – 

AMF function   –

Input configuration   

Output configuration   

Voltage measurement Gen. / Mains 3 ph / 3 ph 3 ph / 3 ph 3 ph / –

Current measurement – 3 ph 3 ph

kW/kWh/kVA measurement –/–/– //  // 

Generator protections –  

History file –  –

RTC with battery –  –

ATS/GCB/MCB control with feedback  1)/  1) / –2)/ –

D+ battery charging alternator circuit – – 

Engine hours –  

Internet support with Web server with IB-Lite with IB-Lite with IB-Lite

Internet support over GPRS with IL-NT GPRS with IL-NT GPRS with IL-NT GPRS

Remote communication interface O O O

Modem interface O O O

Modbus interface – O O

Remote display O O O

Active SMS/emails – O O

KEY  included Legend: ATS: Automatic transfer switch


– excluded GCB: Generator circuit breaker
O Optional – plug-in module required MCB: Mains circuit breaker
1) Manual/automatic ATS, MCB and GCB control, but without feedback
2) Automatic GCB control without feedback

References United Kingdom


Silverwood Business Park

This project is equipped with two gen-sets and one incoming mains supply. The site uses the
ComAp InteliLiteNT AJP3200 controllers and the ComAp InteliATSNT, there are 2 × IL-NT AJP3200
remote display panels and an InteliATSNT PWR on the switchboard. The 2 gen-sets also have
2 × IL-NT AJP3200 panels fitted on them. The InteliATSNT has an IB-Lite fitted allow it to be
connected into MITIE’s local network via an Ethernet connection, and provides the facility to
monitor and test the system via PC monitoring and control software.

MANUFACTURER: LOCAL DISTRIBUTOR / PARTNER:

ComAp a.s.

Czech Republic
Phone: + 420 246 012 111
Fax: + 420 266 316 647
E-mail: info@comap.cz
Internet: www.comap.cz

Customer satisfaction is our mission. We continuously develop our people to be the best to succeed in our mission.

© ComAp. Features and specification are subject to change without prior notice. 2015-01/CPLEIANT
Product data sheet RXM4AB1B7
Characteristics Miniature plug-in relay, 6 A, 4 CO, 24 V AC

Main

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Range of product Harmony Relay
Series name Miniature
Product or component type Plug-in relay
Device short name RXM
Contacts type and composition 4 C/O
[Uc] control circuit voltage 24 V AC 50/60 Hz
[Ithe] conventional enclosed thermal current 6 A at -40…55 °C

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Status LED Without

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Control type Lockable test button
Utilisation coefficient 20 %

Complementary
Shape of pin Flat
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 2.5 KV during 1.2/50 µs
Contacts material AgNi
[Ie] rated operational current 3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL
Maximum switching voltage 250 V conforming to IEC
Load current 6 A at 250 V AC
6 A at 28 V DC
Maximum switching capacity 1500 VA/168 W
Minimum switching capacity 170 mW at 10 mA, 17 V
Operating rate <= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability 10000000 Cycles
Electrical durability 100000 Cycles for resistive load
Average coil consumption in VA 1.2 at 60 Hz
Average consumption 1.2 VA at 60 Hz
Drop-out voltage threshold >= 0.15 Uc
Operating time 20 ms
Reset time 20 Ms
Average resistance 180 Ohm at 20 °C +/- 15 %

Mar 10, 2021


1
Rated operational voltage limits 19.2...26.4 V AC
Safety reliability data B10d = 100000
Protection category RT I
Test levels Level A group mounting
Operating position Any position
CAD overall height 79 Mm
CAD overall depth 78.45 Mm
Net weight 0.037 Kg
Device presentation Complete product

Environment
Dielectric strength 1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact
2000 V AC between poles
Product certifications CSA
Lloyd's
CE
UL
GOST
Standards CSA C22.2 No 14
UL 508
EN/IEC 61810-1
Ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -40…55 °C
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection IP40 conforming to EN/IEC 60529
Shock resistance 10 gn for in operation
30 gn for not operating
Pollution degree 2

Packing Units
Package 1 Weight 0.036 Kg
Package 1 Height 0.410 Dm
Package 1 width 0.210 Dm
Package 1 Length 0.280 Dm

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

2
Product data sheet RXM4AB2P7
Characteristics Miniature plug-in relay, 6 A, 4 CO, LED, 230 V
AC

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range of product Harmony Relay
Series name Miniature
Product or component type Plug-in relay
Device short name RXM
Contacts type and composition 4 C/O
[Uc] control circuit voltage 230 V AC 50/60 Hz

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
[Ithe] conventional enclosed thermal current 6 A at -40…55 °C

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Status LED With
Control type Lockable test button
Utilisation coefficient 20 %

Complementary
Shape of pin Flat
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 2.5 KV during 1.2/50 µs
Contacts material AgNi
[Ie] rated operational current 3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL
Maximum switching voltage 250 V conforming to IEC
Load current 6 A at 250 V AC
6 A at 28 V DC
Maximum switching capacity 1500 VA/168 W
Minimum switching capacity 170 mW at 10 mA, 17 V
Operating rate <= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability 10000000 Cycles
Electrical durability 100000 Cycles for resistive load
Average coil consumption in VA 1.2 at 60 Hz
Average consumption 1.2 VA at 60 Hz
Drop-out voltage threshold >= 0.15 Uc
Operating time 20 ms
Reset time 20 Ms

Mar 10, 2021


1
Average resistance 15000 Ohm at 20 °C +/- 15 %
Rated operational voltage limits 184...253 V AC
Safety reliability data B10d = 100000
Protection category RT I
Test levels Level A group mounting
Operating position Any position
CAD overall height 82.8 Mm
CAD overall depth 80.35 Mm
Net weight 0.037 Kg
Device presentation Complete product

Environment
Dielectric strength 1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact
2000 V AC between poles
Product certifications CE
CSA
GOST
UL
Lloyd's
Standards CSA C22.2 No 14
EN/IEC 61810-1
UL 508
Ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -40…55 °C
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection IP40 conforming to EN/IEC 60529
Shock resistance 10 gn for in operation
30 gn for not operating
Pollution degree 2

Packing Units
Package 1 Weight 39.000 G
Package 1 Height 41.000 Mm
Package 1 width 28.000 Mm
Package 1 Length 21.000 Mm

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

You might also like