Professional Documents
Culture Documents
Operating Instructions: Fan Deck Unit
Operating Instructions: Fan Deck Unit
Contents:
1. General information
2. Safety information
3. Technical data
4. Connection & start up
5. Installation
6. Putting into operation
7. Maintenance and service
1- General information
Different type and size of blowers, not ready-to-be used as products, but designed
as components, for air conditioning, to be fitted into machinery . The fans may only
be operated when they are installed as intended, and when safety is ensured by
safety equipment according to EN 60335-1 or by other protection measures.
When unpacking, take care to lift properly the unit in order to avoid
unbalancing and lift it out very gently and carefully. Shocks have to be avoided
by all means!
2
2. Safety information
Please read these operating instructions before starting to work on the device.
Observe the following warning to prevent malfunctions or physical damage to
properties and/or people.
b. This unit is not intended for use by individuals (including children) with
reduced physical, sensorial or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
e. Fans are only intended for moving air as component of a final product.
f. Fans are only to be operated within the range specified on the motor name-
plate or in the technical specification released by Technical Dept.
g. The unit complies with the applicable standard and regulation and meets the
requirements of the Low Voltage Directive 73/23/EEC and ECM guideline
89/336/EEC
i. Secure the device against accidental contact and make sure, when the device
is disconnected from the power supply, to wait until centrifugal blower is
completely stopped before working on the machine
m. Wait one minute after disconnection from the supply line before opening any
electrical part of the unit
4
3. Technical Data
5
Connection and Start up
When unpacking the unit, pay attention to take the unit only from the plate.
Check the device for transport damage, in case any damage is identified, the
unit must not be installed.
The user is the sole responsible of the correct use of the unit in the final
application.
Use only cables that meet the specified installation requirements for voltage,
current, insulation material, load, etc…
Refer to the diagram below for connection details
Before connecting the device, ensure that the power supply voltage matches
the operating voltage of the device (refer to the rated data)
When fan motor is powered up, verify the correct direction of the fan
blade/wheel and make sure it cannot touch any fixed part.
When working on the fan, the operator must switch off the machine in which
the fan is installed and secure it from being switch on again.
6
4. Installation
Check that installation and electrically connection are properly completed, safety equipment is in place
and motor protection device is in function before connecting the product to the supply line.
Check that the fan blade/wheel can rotate freely once the unit is mounted and with the right sense of
rotation. Only if all potentially dangerous conditions are excluded, the fan can be put into operation!
Switch on the power supply and check direction of rotation and verify the smooth running.
7
6. Maintenance and service
Before making any maintenance or repairing operation, the unit must be securely
disconnected from any power supply source and the operator must wait until the unit is
completely stopped.
Inzago, 10/12/2012
Elco reserves the right to change any specifications or data without notice.