UTAdvanced
Digital Indicating Controller UT75A / UT55A / UT52A / UT35A / UT32A
Program Controller UP55A / UP35A / UP32A
Digital Indicator with Alarms UM33A
Bulletin 05P01A02-01EN
Reliable and secure lineup
Welcome new members: 2-loop and DIN rail models,
and the UP32A UP55A
A variety Helpful
UT52A
UT32A/MDL
UT32A-D UT35A/MDL 172608
Easily edit settings from a PC while the unit is mounted on the controller board.
Settings are accessed through a dedicated adapter on the front panel. • Set up parameters
Maintenance of Ethernet-equipped controllers can be handled remotely. • Controller data read/write/compare
Control board (Powered) • Data management
• Print parameters and data, and create reports
• Configure user defaults
Set up right out of the box
To USB port
No power cable
required
LL50A Parameter
Setting Software
Optical Dedicated cable
communication LL50A contents: Light-loader adapter, Dedicated cable
adapter and
dedicated cable With DIN rail mountable controllers (/MDL option), used to perform
(Light loaderTM) maintenance when powered.
To USB port Free software now available on the web for converting GREEN series
parameters to UTAdvanced.
Can be supported with a single spare unit Gets you back home. Fast.
Universal Input and Output Shorter recovery time User defaults function
Supports different sensors, heaters, The LL50A lets you configure
and actuators user default values. Easily
TC
restored by
mV 4 to 20 mA current
Ever get lost in a maze of key operation
V configuration changes? Now you
mA
Voltage pulse can restore user-personalized
RTD default parameters. Recover
Relay contact quickly without disturbing
2-wire
Motor operated valve* operations.
transmitter
*Select a position proportional model
for motorized valve control output.
UT32A/MDL
UT52A/MDL
UT32A-D/MDL
5
digit
display
14
segment
display
• Alarms
Normal According to… Alarm • Deviation values
• Measured values
Display color changes! • Contact input
• Choice of fixed white or red
Navigation guides and keys make it easy to operate Fast one-touch operations
Controller will guide the key you press. Programmable Function Keys
Navigation Guide
You can assign frequently used operations
(start/stop, remote/local, etc.) and
parameter entry screens (PID value, etc.)
to function keys for one-touch availability.
Navigation Keys
Modbus/TCP
Modbus
RTU/ASCII
Ladder communication UTAdvanced with RS-485 communication
Modbus/TCP
FA-M3V
Modbus TCP, a protocol that allows the controller to
connect to Ethernet network and have the ability to
SMARTDAC+ exchange data with the computers or devices on that
PLC GX10/GX20
network.
Ethernet
Example: A UT in which an input error occurs sends a signal to another UT • Finely adjust the temperature setting of the slave
to enable that UT switch to MAN operation, thus shifting the whole system with the bias and ratio
into a safe mode. In such a case, the safety mechanism can be built into • Upstream PLC or other device not needed for tuning
the UTAdvanced and is not required in the host system.
• No programming means fewer engineering manhours
* Create ladder sequence programs by the LL50A Parameter Setting software (sold separately).
Continuous
RS485
furnace
RS-485
1 2 4 15 32
Zone 3 Zone 2 Zone 1
Up to 4 master units, total 32 units SP is zone 1 SP is zone 1 SP is programmed
SP minus 5 °C SP plus 10 °C
Using the UTAdvanced ladder sequence control function offers a low-cost alternative for applications
typically dependent on compact units such as PLCs, timers, and relays. Plus, it saves wiring labor and
space. The ladder sequence control function supports the customized specifications of your customers.
* Requires parameter setting software (sold separately).
Less wiring
PLC
Relay
Timer
Highly customizable
GS 05P01C31-01EN GS 05P01D31-01EN
GS (General Specifications) GS 05P01B41-01EN
GS 05P01C81-01EN GS 05P01D81-01EN
1 2 1
172608
GS 05P01D31-01EN GS 05P08D31-01EN
GS 05P02C41-01EN GS 05P02D41-01EN GS 05P03D21-01EN
GS 05P01D81-01EN GS 05P08D81-01EN
96
code
Digital Indicating Controller (Power supply 100-240 V AC)(provided with
UT52A retransmission output or 15 V DC loop power supply , 3 DIs, and 3 DOs)
-0 Standard type
Type 1:
-1 Position proportional type
Basic control
-2 Heating/cooling type
0 None
Remote (1 additional aux. analog) input, 1 additional DI,
11 Type 2: 1
and RS-485 commuication (Max. 38.4 kbps, 2-wire )
65 Functions
Bracket 2 Remote (1 additional aux. analog) input and 1 additional DI
Terminal cover 3 2 additional DIs, and 2 additional DOs
20
Type 3: 0 None
Open networks 3 CC-Link communication (with Modbus master function) (*1)
-1 English (Default. Can be switched to other language by the setting.)
-2 German (Default. Can be switched to other language by the setting.)
Display language(*2)
-3 French (Default. Can be switched to other language by the setting.)
105.2
91.6
94.6
Application examples
0 None
96
Application examples
Heating
(4 to 20 mA DC)
Thermocouple Cooling water
SCR
4 to 20 mA DC
Thyristor
Heating unit
SCR Thermocouple
Electric furnace
Thyristor
60
DIN rail
TH35-75A
94.6
100
114
91.6
96 20 100 4.3
Main Features
4
• DIN rail mounting
UT52A/UT32A (with option /MDL)
• Tidy appearance 60
• Up to 4 analog inputs available DIN rail
TH35-75A
• 3 alarm relays with independent common terminals
• 500 steps of ladder logic control
94.6
91.6
• Comes with a wealth of functions
100
114
48.2 20 100 4.3
4
UT55A/UT52A: terminal cover comes standard
UT35A/UT32A: terminal cover sold separately
Optional Optional
Model Suffix code suffix Description Model Suffix code suffix Description
code code
Digital Indicating Controller (Power supply 100-240 V AC) Digital Indicating Controller (Power supply: 100-240 V AC)
UT55A /MDL (provided with retransmission output or 15 V DC loop power supply , UT35A /MDL (provided with retransmission output or 15 V DC loop power supply, 2 DIs,
(Required) (Required)
3 DIs, and 3 DOs) (without the display parts and keys) and 3 DOs)(without the display parts and keys)
Type 1: -0 Standard type Type 1: -0 Standard type
Basic control -2 Heating/cooling type Basic control -2 Heating/cooling type
0 None Type 2: 0 None
Remote (1 additional aux. analog) input, 1 additional DI, and RS-485 Functions 2 5 additional DIs, 5 additional DOs
2
communication (Max.19.2 kpbs, 2-wire or 2-wire/4-wire) (*1) 1 RS-485 communication (Max.38.4 kbps, 2-wire/4-wire)
Type 2:
3 5 additional DIs and 5 additional DOs 2 Ethernet communication (with serial gateway function)
Functions Type 3:
4 Remote (1 additional aux. analog) input and 1 additional DI 3 CC-Link communication (with Modbus master function)
Open networks
5 Remote (1 additional aux. analog) input, 6 additional Dls, and 5 additional DOs 4 PROFIBUS-DP communication (with Modbus master function)
7 3 additional aux. analog inputs and 3 additional DIs 5 DeviceNet communication (with Modbus master function)
1 RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire) Fixed code -1 Temperature unit: deg C & deg F
2 Ethernet communication (with serial gateway function) Case color 1 Black (Light charcoal gray)
Type 3:
3 CC-Link communication (with Modbus master function) Fixed code -00 Always "-00"
Open networks
4 PROFIBUS-DP communication (with Modbus master function) /MDL Mount on DIN rail (without the display parts and keys) (*1)
5 DeviceNet communication (with Modbus master function) (Required)
Fixed code -1 Temperature unit: deg C & deg F /LP 24 V DC loop power supply (*1)
Optional suffix codes
Case color 1 Black (Light charcoal gray) /DC Power supply 24 V AC/DC
Fixed code -00 Always “-00” /CT Coating (*2)
/MDL Mount on DIN rail (without the display parts and keys) (*2) /CV Terminal cover
(Required)
*1: The /MDL option and /LP option can be specified in the combination of Type 2 code “0” and Type 3 code “1”.
Optional suffix codes /DC Power supply 24 V AC/DC *2: When the /CT option is specified, the UT35A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT
/LP 24 V DC loop power supply (*2) option are not intended for EEA-market).
/CT Coating (*3)
*1: When the /LP option is specified, the RS-485 communication of the Type 2 code “2” is 2-wire system. Optional
Model Suffix code suffix Description
*2: The /MDL option and /LP option can be specified in the combination of Type 2 code (any of “0”, “2”, “3”, or “4”) and Type 3 code “1”. code
*3: When the /CT option is specified, the UT55A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT Digital Indicating Controller (Power supply: 100-240 V AC)
option are not intended for EEA-market). /MDL (provided with retransmission output or 15 V DC loop power supply, 2 DIs,
UT32A (Required)
and 3 DOs) (without the display parts and keys)
Optional Type 1: -0 Standard type
Model Suffix code suffix Description
code Basic control -2 Heating/cooling type
Digital Indicating Controller (Power supply 100-240 V AC) Type 2: 0 None
UT52A /MDL (provided with retransmission output or 15 V DC loop power supply , Functions 1 RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire) (*1)
(Required)
3 DIs, and 3 DOs) (without the display parts and keys) Type 3: 0 None
Type 1: Open networks 3 CC-Link communication (with Modbus master function)
-0 Standard type
Basic control Fixed code -1 Temperature unit: deg C & deg F
0 None Case color 1 Black (Light charcoal gray)
Type 2:
Remote (1 additional aux. analog) input, 1 additional DI, Fixed code -00 Always "-00"
Functions 1
and RS-485 commuication (Max. 38.4 kbps, 2-wire ) /MDL
None Mount on DIN rail (without the display parts and keys) (*2) (*3)
Type 3: 0 (Required)
Open networks 3 CC-Link communication (with Modbus master function) /LP 24 V DC loop power supply (*3)
Fixed code -1 Temperature unit: deg C & deg F Optional suffix codes /HA Heater break alarm (*4)
Case color 1 Black (Light charcoal gray) /DC Power supply 24 V AC/DC
Fixed code -00 Always “-00” /CT Coating (*5)
/MDL Mount on DIN rail (without the display parts and keys) (*1) /CV Terminal cover
(Required)
Optional suffix codes *1: When /LP option is specified, the RS-485 communication of the type 2 code “1” is 2-wire system.
/DC Power supply 24 V AC/DC *2: The /MDL option is specified, the model and suffix codes are follows:
/CT Coating (*2) UT32A-010-11-00/x/MDL
*1: When the /MDL option is specified, the model and the suffix codes are as follows: UT32A-003-11-00/x/MDL
UT52A-010-11-00/x/MDL UT32A-210-11-00/x/MDL
UT52A-003-11-00/x/MDL *3: When /MDL option and /LP option is combined, “3” can not be specified for Type 3 code.
*2: When the /CT option is specified, the UT52A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT *4: The /HA option can be specified only in the combination of Type2 code "1" and Type 3 code “0.”
option are not intended for EEA-market). *5: When the /CT option is specified, the UT32A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT
option are not intended for EEA-market).
105.2
91.6
94.6
96
Bracket
Main Features 1 to 10 mm (panel thickness)
• Dual-loop control
UT32A-D (with option /MDL)
• Space-saving 60
• Simple operation DIN rail
TH35-75A
• Ladder sequence programs can be built
• 3 alarms available as standard
94.6
91.6
100
114
48.2 20 100 4.3
4
Panel mounting DIN rail mounting
Optional Optional
Model Suffix code suffix Description Model Suffix code suffix Description
code code
Digital Indicating Controller (Power supply: 100-240 V AC) /MDL Digital Indicating Controller (Power supply: 100-240 V AC)
UT32A (provided with 3 DIs and 3 DOs) UT32A (Required) (provided with 3 DIs, and 3 DOs) (without the display parts and keys)
Type 1: Type 1:
-D Dual-loop type -D Dual-loop type
Basic control Basic control
0 None Type 2:Functions 1 RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire)
Type 2:Functions
1 RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire) Type 3:Fixed code 0 None
Type 3:Fixed code 0 None Fixed code -1 Temperature unit: deg C & deg F
-1 English (Default. Can be switched to other language by the setting.) Case color 1 Black (Light charcoal gray)
-2 German (Default. Can be switched to other language by the setting.) Fixed code -00 Always "-00"
Display language (*1)
-3 French (Default. Can be switched to other language by the setting.) /MDL Mount on DIN rail (without the display parts and keys)
-4 Spanish (Default. Can be switched to other language by the setting.) (Required)
0 White (Light gray) Optional suffix codes /DC Power supply 24 V AC/DC
Case color
1 Black (Light charcoal gray) /CT Coating (*1)
Fixed code -00 Always "-00" /CV Terminal cover
/HA Heater break alarm (*2)
/DC Power supply 24 V AC/DC *1: When the /CT option is specified, the UT32A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT
Optional suffix codes option are not intended for EEA-market).
/CT Coating (*3)
/CV Terminal cover
*1: English, German, French, and Spanish are available for the guide display.
*2: The /HA option can be specified when the Type 2 code is "0."
*3: When the /CT option is specified, the UT32A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT
option are not intended for EEA-market).
Application examples
Remote SP
RS485
UT32A-D UT32A-D
Hatch eggs right on schedule FA-M3
by using overall heating control
Always “-00”
96
Application examples
2-loop control with a single controller A variety of arithmetic instructions and large capacity ladder programs
■ 2-loop synchronous and independent operation ■ 15 basic instructions and 111 application ■ Square root, exponential, and logarithmic
is available instructions calculations are available
• The start and stop instructions can be run synchronously ■ Ladder program capacity up to 1,000 steps ■ Temperature/humidity and CP calculations
or independently. are available
■ Program pattern operation and constant value
operation are available for 2-loop control CP control
• A sequence can be run by combining the program pattern CP control
operation and fixed-point operation.
Accomplished by UT75A
a ladder program Temperature Temperature
Temperature/humidity control 4-20mA
relay O2 %C
Dry-bulb Furnace voltage pulse
temperature CP
temperature CP value PID
Wet-bulb (TC) Atmosphere Reference GX20
temperature calculation control air recorder
(O2 sensor) (CpCalc)
O2 sensor
Positioner Control valve
Thermocouple
Partial Enriched gas
Partial pressure 4-20mA
SCR pressure of CO CP value Proportional valve
of O2 (mV) Constant (analog transmission)
Steam Dilution air
value Carrier gas Control valve
Requires arithmetic instruction of ladder programs. Furnace
O2 sensor wall
91.6
94.6
*1: When the Type 2 code is “3”, only “0” can be specified for the Type 3 code.
*2: English, German, French, and Spanish are available for the guide display.
*3: The /DR option can be specified only when the Type 2 code is “1” or “4.”
*4: The /HA option can be specified only when the Type 1 code is “-0.”
*5: When the /CT option is specified, the UP55A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT
Bracket option are not intended for EEA-market).
1 to 10 mm(panel thickness)
Basic control
-2 Heating/cooling type
0 None
Type 2:Functions 1 RS-485 communication (Max.38.4 kbps, 2-wire/4-wire)
2 2 additional DIs, 2 additional DOs
Type 3: 0 None
Bracket CC-Link communication (with Modbus master function) (*1)
Open networks 3
1 to 10 mm (panel thickness) -1 English (Default. Can be switched to other language by the setting.)
-2 German (Default. Can be switched to other language by the setting.)
Display language(*2)
-3 French (Default. Can be switched to other language by the setting.)
*1: English, German, French, and Spanish are available for the guide display. -4 Spanish (Default. Can be switched to other language by the setting.)
UP35A *2: The /HA option can be specified only when the Type 1 code is "-0" or "-2." Case color
0 White (Light gray)
*3: When the /CT option is specified, the UP35A does not conform to the safety standards (UL and CSA) and CE marking 1 Black (Light charcoal gray)
(Products with /CT option are not intended for EEA-market). Fixed code -00 Always “-00”
/AP 2 additional patterns/20 additional segments
UP32A *1: Type 3 code “3” can be specified only when both Type 1 and Type 2 code are “0”.
*2: English, German, French, and Spanish are available for the guide display.
/HA Heater break alarm (*3)
Optional suffix codes /DC Power supply 24 V AC/DC
*3: The /HA option can be specified only when the Type 1 code is “-0” or “-2” and Type 3 code is “0”.
/CT Coating (*4)
*4: When the /CT option is specified, the UP32A does not conform to the safety standards (UL and CSA) and CE marking
(Products with /CT option are not intended for EEA-market). /CV Terminal Cover
96
Bracket
Bracket
65
48
1 to 10
(panel thickness)
11
Normal Alarm
LL50A -00 Parameter Setting Software with Ladder Program Building Function
Tuning display
Temperature
Temperature
Temperature
fine control and suppress overshoot. SUPER: on SUPER:on SUPER:on
Effect 1 : Material change or load change with the same PID. Effect 2 : Setpoint (SP) change with the same PID.
When SUPER2 function is not used When SUPER2 function is used When SUPER2 function is not used When SUPER2 function is used
PV PV PV PV
SP PV
Autotuning is a function that evaluates process character- Using the message function and turning the contact input
istics to automatically set optimal values relative to a on/off, the message registered beforehand can be
target value that determines a PID constant. To implement displayed on PV display by interrupt. The message is
autotuning, you can configure the following conditions. registered using LL50A Parameter Setting Software. The
messages are limited to 20 alphanumeric characters. A
• Two types of algorithms to calculate PID constants are
available for selection. maximum of four messages can be registered.
Normal: Fast-rising PID constant
Stable: Slow-rising PID constant Operation Display
• High and low output limits can be set individually for control
output values during AT runtime.
PV
Deviation
Normal PV zone:
300˚C Green color SP
figures displayed
250˚C
Under normal PV
zone: Amber color
figures displayed
Time
Application
Heating and cooling (two outputs model) Alarm detection with active display Monitoring and setting from external device
Cooling control output TC10
PV SMARTDAC+
Recorder PLC
350˚C
250˚C
or
Chambers
Heating Time
control Annunciator
output Buzzer RS485
Cooling water
Modbus RTU communication (Option)
Sensor
SSR
Heater Solid state Relay
GA10
Ethernet, serial
GM MX GX µR DX UT WT Modbus Software
MW GP DR MV PR/UPM Devices
DA CX JUXTA
DAQLOGGER
DAQ32Plus
MXLOGGER
Specifications (Overview)
• Max. connectable units: 100 • Max connectable clients: Unlimited (verified with 32)
• Max. recording tags (channels): 2000 • Scan interval: 100 ms or higher (using PC time),
• Max. recording MATH tags (channels): 200 or scan interval of instruments (using instrument time)
General Specifications: GS 04L65B01-01E
RS-485
UTAdvanced Search
www.UTAdvanced.com
NOTICE
Co-innovating tomorrow, OpreX, and Synaptic Business Automation are trademarks or registered trademarks ● Before operating the product, read the user's manual thoroughly for proper
of Yokogawa Electric Corporation. All brand or product names of Yokogawa Electric Corporation in this bulletin and safe operation.
are trademarks or registered trademarks of Yokogawa Electric Corporation. ● If this product is for use with a system requiring safeguards that directly
All other company brand or product names in this bulletin are trademarks or registered trademarks of their involve personnel safety, please contact the Yokogawa sales offices.
respective holders.