You are on page 1of 10

25605B 20 OT6031 OT6031 25605B

(i)
2019(Odd) Old Syllabus

Time : 3Hrs. Sem - VI Mech


R & AC
Full Marks : 80
Pass Marks : 26
Answer all 20 questions from Group A, each question
***
carries 1 marks.

Answer all Five questions from Group B, each question


carries 4 marks.

Answer all Five questions from Group C, each question


carries 8 marks.

All parts of a question must be answered at one place in


sequence, otherwise they may not be evaluated.

The figure in right hand margin indicate marks.

P.T.O
25605B 2 OT6031 OT6031 19 25605B
GROUP - A
1. Choose the most suitable answer from the following
options : 1x20=20
(i)
11.
Air refrigeration cycle is used in ........
sketch.
(a) Commercial refrigerators 8
(b) Domestic refrigerators
(c) Air-conditioning
(d) Gas liquefaction
OR
(i)
reading dry bulb temperature =350C,
Wet bulb temperature =250C. Find:
(i) Specific humidity
(ii) Relative humidity
(ii) The ratio of high temperature to low (iii) Partial pressure of vapour
temperature for reversed carnot refrigeration (iv) Enthalpy of air take atmospheric pressure
is 5/4, the COP will be: =1.0132 bar
(a) 2
(b) 3
(c) 4
(d) 5
25605B 18 OT6031 OT6031 3 25605B

OR (ii)

The air supplied to a room of a building in winter


is to be at 170C and have a relative humidity of
60% if the barometric pressure is 1.01325 bar. Find
(i) Specific humidity
(ii) Dew point temperature

(iii)
heat pump is :
(a) 5
(b) 4
(c) 3
(d) 2

10. (iii) COP


which affect human comfort.
8

OR
(iv)
In an ideal vapour compression refrigeration cycle (a) (C.O.P.) R = (C.O.P.)H P. +1
the refrigeration effect is 80 Kl/Kg of refrigerant (b) (C.O.P.) R = (C.O.P.)H P. +2
flow. The COP is 4. If the flow of the refrigerant is (c) (C.O.P.)H P. = (C.O.P.) R +1
2Kg/sec. Find the heat rejected in the condensor. (d) None of these

P.T.O
25605B 4 OT6031 OT6031 17 25605B
(iv) OR
The capacity of a refrigerator is 600 tons when
working between -50C and 200C. Find the Ice
produced within 24 hours water is supplied at 100C.
Also find the minimum KW required to run the
system. Latent heat of Ice =336 Kl/kg.
(v) The tubes at the back of domestic
refrigerator are:
(a) Condenser -50C 200C
(b) Evaporator
(c) Capillary tubes
(d) All of the above
(v)
9.
(i) Tonne of refrigeration
(ii) Specific humidity
(iii) C.O.P. refrigeration
(iv) Dew point temperature
(vi) 8
compressor is called...........
(a) Vapour absorption refrigerator
(b) Vapour compressor refrigerator
(c) Electrolux refrigerator
(d) Carnot refrigerator
P.T.O
25605B 16 OT6031 OT6031 5 25605B

GROUP - C (vi)
Answer all Five Questions .
8 x 5 = 40

7. Find the expression of ideal C.O.P for vapour


absorption refrigeration system.
8
C.O.P (vii) In vapour absorption refrigeration system,
the compressor is replaced by:
(a) Liquid pump
OR (b) Generator
(c) Absorber and generator
(d) Absorber, generator and liquid pump

(vii)

8. A bell- coleman air refrigeration, air enters at -50C


at 1 bar and compressed 1sentropically to 5 bar and
cooled to 270C at upper pressure then expanded
1 sentropically to initial pressure. Find C.O.P of cycle.
8
-5 C (viii)
pressure is know as...........
(a) R-11
(b) R-12
(c) R-22
C.O.P (d) Amonia

P.T.O
25605B 6 OT6031 OT6031 15 25605B
(viii)
6.
(ix) For large ton (more than 200 TR) cooling.
air -conditioning application, the compressor 4
recommended is:
(a) Reciprocating
(b) Rotating
(c) Centrifugal
(d) Screw OR
(ix) 200 TR
Enthalpy at compressor inlet = 1200 Kl/kg
Enthalpy at compressor outlet = 1400 Kl/kg
Enthalpy at condenser outlet = 200 Kl/kg.
Find C.O.P or cycle.
(x)
(a) Less boiling point
(b) High critical temperature
(c) High latent heat of vaporization
(d) All of these
P.T.O
25605B 14 OT6031 OT6031 7 25605B

(x)

OR

between temperature limit in 300K and 400K. Find (xi) Specific humidity is also called:
the C.O.P. of machine.
(a) Relative humidity
(b) Humidity ratio
(c) Absolute humidity
(d) None of these

(xi)
5. What is relative humidity? How is it defined as the
ratio of two mole fractions.
4

(xii)
OR
indicates :
(a) Dry bulb temperature
cooling and refrigeration take place at the (b) Wet bulb temperature
temperature 1000C, 200C and -100C. Find the (c) Dew point temperature
theoretical C.O.P. of system. (d) Relative humidity

P.T.O
25605B 8 OT6031 OT6031 13 25605B
(xii) OR
What are the essential properties of good refrigerant.
3.
(xiii) Which of the following is suitable for 100%
4
relative humidity?
P-v T-S
(a) WBT > DBT > DPT
(b) WBT < DBT <DPT
(c) WBT= DBT = DPT OR
(d) WBT < DBT
A reversed Carnot engine remove 50 KW from a
(xiii)
heat sink. The temperature of the heat sink is 250K
and the temperature of the heat reservoir is 300K.
Find the power required of the engine.
50 KW
(xiv)
(a) Wet bulb temperature
(b) Relative humidity
(c) Dry bulb temperature 4.
(d) Specific humidity refrigeration system. 4
P.T.O
25605B 12 OT6031 OT6031 9 25605B

(xx) (xiv)
30 Kl/sec 20 Kl/sec

(xv) During dehumdification process ................


remains constant.
(a) Wet bulb temperature
(b) Relative humidity
(c) Dry bulb temperature
(d) Specific humidity

(xv)

Answer all Five Questions.


4 x 5 = 20

2. Explain the principle of evaporative refrigeration (xvi)


system. (a) Cooling
4
(b) Heating
(c) Dehumidifying
(d) All of these

P.T.O
25605B 10 OT6031 OT6031 11 25605B
(xvi) (xviii)
(xvii) The human body feels comfortable when
(xix) During sensible cooling of air, specific
heat stored in the body is:
humidity:
(a) Positive
(a) Remain constant
(b) Negative (b) Increases
(c) Zero (c) Decreases
(d) None of these (d) Any one of the aboe
(xvii) (xix)
(xx)
(xviii)
added 30 Kl/sec and latent heat added is
humidification process: 20 K1/sec. The sensible heat factor will be:
(a) Remain constant (a) 0.3
(b) Increases (b) 0.6
(c) Decreases (c) 0.67
(d) Any of the above (d) 1.5
P.T.O