You are on page 1of 3

1

Mechanical Engineering Hinglish


Applications of Thermodynamics
DPP-01
Refrigerants
1. [MSQ] (b) In the Domestic Refrigerator refrigerant is R12,
A good refrigerant should have which of the following CCl2F2 (dicholoro - difluoro methane)
properties. (c) Freons are responsible for the depletion of the
(a) High latent heat of vaporization ozone layer by chlorine atoms in the upper
(b) Lower specific heat atmosphere (stratosphere).
(c) High critical temperature (d) All of these
(d) Low specific volume 7. [MCQ]
The chemical name of Freon 22 is
2. [MSQ] (a) CCl3F (b) CH3Cl
Which of the following is/are true disadvantage(s) of (c) CHClF2 (d) CCl2F2
Bell-Coleman cycle
(a) Low COP 8. [MCQ]
(b) High running cost Match List-I (Refrigerant) with List-2 (Uses) and
(c) Small system size select the correct answer using the code given below
(d) More chances of frosting at expander the list- II
List – I List – II
3. [MCQ] (i) R-22 (A) Direct contact freezing of
The chemical formula of R-134 is foods
(a) CHClF2 (b) C2Cl3F3 (ii) R – 134a (B) Cold storage plants
(c) C2Cl2F4 (d) C2H2F4 (iii) NH3 (C) Windows AC
(iv) Brine (D) Domestic Refrigerator
4. [NAT] (v) CO2 (E) Milk chilling plants
A Bell Coleman cycle works under pressure ratio of 10. (a) i-D, ii-C, iii-B, iv-E, v-A
The refrigerating effect when air enters compressor at (b) i-C, ii-A, iii-D, iv-E, v-B
300K and air is cooled by 40 degrees in condenser is (c) i-C, ii-D, iii-B, iv-E, v-A
_______ kJ/kg. (d) i-D, ii-C, iii-A, iv-E, v-B

5. [NAT] 9. [MSQ]
A Bell Coleman cycle works under pressure ratio of 10. Which of the following statements is/are true:
Air enters compressor at 300 K and air is cooled by 40 (A) An automatic expansion valve maintains a
degrees in condenser. The change in COP if air is constant pressure in the condenser.
superheated in the evaporator by 10 degrees (B) An automatic expansion valve maintains a
________%. constant pressure in evaporator.
(C) In an automatic expansion valve the mass flow
6. [MCQ] rate of refrigerant increases as refrigeration load
Which of the following is true for Refrigerants. increases.
(a) In Room Air-Conditioner refrigerant is CHCIF2 (D) Automatic expansion valve-based systems are
critically charged.
(mono-chloro - difluoro methane), also called
Freon 22 or R22.
2

10. [MCQ]
The subcooling in a vapour compression refrigeration
system can be achieved by which of the following
methods.
(a) Circulating more quantity of cooling water
through condenser.
(b) Using water colder than the main circulating
water.
(c) Employing a heat exchanger
(d) Any one of the above.

❑❑❑
3

Answer Key
1. (a, b, c, d) 6. (d)
2. (a, b) 7. (c)
3. (d) 8. (c)
4. 20.8 (20.5 to 21.0) 9. (b, c)
5. 0 (0 to 0) 10. (d)

Any issue with DPP, please report by clicking here:- https://forms.gle/t2SzQVvQcs638c4r5


For more questions, kindly visit the library section: Link for web: https://smart.link/sdfez8ejd80if

PW Mobile APP: https://smart.link/7wwosivoicgd4